01-06-2022 Yb22032 Er - JK Karur STR G+1 St01-Column Details
01-06-2022 Yb22032 Er - JK Karur STR G+1 St01-Column Details
4'-1012"
F
C4 C4 C4 C4 412" 6" 712" N 4. THIS DRAWING SHOULD BE READ ALONG WITH THE RELEVANT F
ARCHITECTURAL DRAWING.
13 412" 412" 412" 5. IF THERE IS ANY REVISION IN DRAWING, FURTHER CONSTRUCTION
C5 C4 C5 SHALL BE EXECUTED AS PER THE LATEST REVISED DRAWING, ON THE
ISSUE OF LATEST REVISION.
6. GRADE OF CONCRETE SHALL BE M20.GRADE OF STEEL SHALL BE Fe500
16'-9"
10'-9"
7. CLEAR COVER FOR
FOOTING :2"(50mm)
GROUND BEAM :1 1/2"(40mm)
412" 6" 712" COLUMN :1 1/2"(40mm)
BEAM :1"(25mm)
412" 712" 412" 412" 12 412" 412" 412" SLAB :3/4"(20mm)
C4 C4 C4
712" 412" 412" 712"
8. LAP LENGTH OF BARS : 50Ø, AT COLUMN LAPPING PROVIDE 4"
5
27'-6"
SPACING OF TIES, NO LAPPING ALLOWED AT BEAM-COLUMN JOINT.
C3 C3 C3 C4 9. DEVELOPMENT LENGTH (Ld) FOR REINFORCEMENT BARS
5'-6"
IN COMPRESSION : 40Ø
6" 6" IN TENSION : 50Ø
E 4 412" 412" 10. IN CASE OF BEAM REINFORCEMENT, NO LAPPING SHALL BE ALLOWED E
16'-9"
C1 C1 IN FOLLOWING PLACES
(a) TOP ROD NEAR COLUMN, L/4 ON EITHER SIDES OF COLUMN
(b) TOP ROD OF CANTILEVER BEAM ALONG THE LENGTH AND
ALSO DEVELOPMENT LENGTH, BEYOND COLUMN
55'-412"
11'
412" 1'-412"
(c) BOTTOM ROD AT MID SPAN OF BEAM
11. REMOVAL OF SHUTTERING / FORM WORK
412" 6" 6" 412" 11 412" 412" (a) COLUMN : 24 HOURS
C2 C2 (b) BEAM SIDES : 24 HOURS
3 712" 712" 712" 712" (c) BEAM BOTTOM : LESS THAN 20' SPAN : 14 DAYS
C4 C1 C1 C5 : MORE THAN 20' SPAN : 28 DAYS
A1 B1 C1 (d) SLAB : LESS THAN 20'SPAN : 14 DAYS
: MORE THAN 20'SPAN : 28 DAYS
HOWEVER 7 DAYS STRENGTH OF CONCRETE SHOULD BE 65% OF THE
CENTRE LINE AND COLUMN LAYOUT
11'-3"
TARGET STRENGTH, TO REMOVE FORM WORK.
12. THIS BUILDING IS DESIGNED FOR GROUND + 1 FLOORS.
412" 412" 412" 412"
D D
2 712" 712" 412" 712"
C4 C4 C4 C5
LEGENDS :
10'-1012"
STIRRUPS @ 4" C/C
STIRRUPS @ 6" C/C
412" 712" 412" 712"
FLOOR LV.
1 6" 6" 6" 6"
C1 C1 C1 C1
A B C D
2'-0"
C C
LAPPING ZONE
L
NOTE: PROJECT
CONSULTANT
- Larger dia bar
1'
1'
2'-0"
SCHEDULE OF COLUMNS
FOUNDATION TO HEADROOM FLOOR LVL Er.Y.BOOPATHI M.E(Struct), M.I.S.T.E,
9" COLUMN LICENSED STRUCTURAL ENGINEER-GRADE-1
REMARKS STRUCTURAL
TYPE PYRAMID STRUCTURAL CONSULTANT
SIZE REINFORCEMENT DETAILS RINGS CONSULTANT
Contact No : +91 9597691155
Mail id :pyramidstrconsultant@gmail.com
C1 12" DIA 3Y16+3Y12 A Y8@7" -
1'-9"
1 2 3 4 5 6 7 8 9 10