You are on page 1of 3

18 17 16 15 14 13 12 11

NEMA 3R
3D Model is the Master Document of Record
Article or Material Must Conform to REACH Procedure SI900000 Sec.14
Article or Material Must Conform to ROHS Procedure SI900000 Sec.13

Geometric Dimensioning & Tolerancing as per ASME Y14.5-2009

NEMA 4 AND 12 3.0 35.5 48.1


Part Must Conform to SI900000 Sec.4 Toxicity Procedure

SAME AS NEMA 3R EXCEPT AS SHOWN [76] [902] [1221]


15.4 LIFTING ANGLES (2)
[392]
1.500
[38,10]

FRONT DOOR
D
QUARTER
TURN
(QTY: 5)
30.4
[772]
CONTROLLER
11.6 LOCKABLE USER INTERFACE
[294] QUARTER 29.0
TURN COVER [737]
QUARTER TURN 33.3
2.4 ( 8) [845]
[61]

SIDE PANEL
LOCKABLE (SAME BOTH SIDES)
LEVER LATCH QUARTER
LOCKABLE TURN
QUARTER (8)
86.0 TURN
[2184]
REAR
PANEL
WINDOW 54
[1365]
C CONTROLLER
USER
INTERFACE
LOCKABLE
QUARTER 54
[1365]
C
TURN

43.4
[1104] X
Y

FRONT VIEW
4.0 2.0
[102]
(2) WELDED [51] Z SIDE VIEW REAR VIEW
C-CHANNELS

35.5
[902]
B .63
7.0
[178]
[16]
SEISMIC NOTES
B
MOUNTING 33.8
1. ENCLOSURE : NEMA 3R, 4 & 12 TYPE, FREE STANDING, FLOOR MOUNT.
30.5 HOLES [859]
2. MATERIAL:10 GA (.134) 1018 HRS REF.
[774] (QTY: 8) 4X .12 MINIMUN 3. FINISH : ANSI 61 GREY
[3,0] DOOR 4. CONSTRUCTION PER UL 1008 STANDARD.
1.0 CLEARANCE
[25] FOR NEMA 3R 5. ALL CABLE ENTRY FOR LUG CONNECTION IS IN REAR OF CABINET.
2.5 CABINETS ONLY
[64] 6. SUITABLE WIRE BENDING SPACE PROVIDED PER UL 1008.
(PLUGGED FOR 7. UL AND CSA RECOGNIZED/CERTIFIED MECHANICAL LUGS ARE STANDARD.
46.8 NEMA 4 &12)
[1187] 8. EQUIPMENT GROUND LUG IS PROVIDED IN ALL UNITS. SEE SHEET 3 FOR DETAILS.
TOP & BOTTOM 9. ALL DIMENSIONS ARE FOR REFERENCE ONLY AND SHOWN IN INCHES(MILLIMETERS).
49.1 29.8 CONDUIT ENTRY AREA 10. 100% RATED SOLID/SWITCHED NEUTRAL PROVIDED PER THE SWITCH CONFIGURATION.
[1248] [756] 11. SUITABLE FOR TOP AND/OR BOTTOM ATS CABLE ENTRY.
Any unauthorized use, reproduction, distribution or disclosure to third parties is strictly forbidden.

2.5 12. SIDES AND REAR PANELS ARE REMOVABLE FOR CABLE CONNECTIONS
ABB PROPRIETARY AND CONFIDENTIAL INFORMATION

3.0 13. WINDOW KIT (NEMA 4, 12) OR COVER (3R) WILL BE PROVIDED AS STANDARD
[64]
The information contained in the document has to be kept strictly confidential.

3.0 [77]
[77] SEISMIC NOTES:
ABB reserves all rights regarding intellectual Property Rights.

1. BOLT ENCLOSURE FROM C-CHANNEL BASE USING THE FOLLOWING


SEISMIC CERTIFIED MOUNTING HARDWARE PER MOUNTING HOLE:
Copyright 2021 ABB. All rights reserved

(HARDWARE PROVIDED BY INSTALLER).


7.0 *1/2-13 GRADE 5 BOLT TORQUE TO 70 FT-LBS. (95 NEWTON METERS).
[178] *1/2-13 STANDARD FLAT WASHER.
*1/2 (13) HELICAL SPRING LOCK WASHER.
2. CENTER OF GRAVITY DIMENSIONS ARE FOR REFERENCE ONLY.
1.5 2.5 3. FOR WORKING CLEARANCE REFER TO NATIONAL AND LOCAL CODES AND STANDARDS.
[38] [63]
1.0
[25]
33.5
[851]
DRAIN HOLES
(QTY:4 ) A
(PLUGGED IN NEMA 4/12)
BOTTOM VIEW
DRAWING FILE MODEL FILE
50C-1097 50C-1097
CONTROLLER CABINET CABLE WEIGHT CENTER OF GRAVITY IN(MM)
AMP POLES TYPE
DATE MODIFIED DESIGNED BY
# RANGE LB(KG) X Y Z 30-Jun-21 03:44:11 PM DV
Calculated for: CN# APPROVED BY TITLE
3 QTY 8 1435(651) C118111 AP ZTGD LAYOUT, 1600-3000A
18.5 38.0 15.0
1600-3000 OXAMI1-L3 F-2019MP #2-600 MCM
VOLUME

(470) (965) (381) 0.000 in^3 Critical to Quality Characteristic NEMA 3R, 4 & 12
4 (33-304 MM2) 1540(699) MASS MATERIAL SPECIFICATION FINISH SPECIFICATION UNITS LOCAL TITLE
1.0 0.000 lbm --- --- in ---
[26] UNLESS OTHERWISE SPECIFIED
BOTTOM VIEW
MATERIAL DESCRIPTION SIZE ROOT NUMBER REV RELEASE STATE

Third Angle Projection TOLERANCE ON:


1 PL DECIMALS # 0.1
--- D 50C-1097 1 Released
DOOR OPEN 2 PL DECIMALS
3 PL DECIMALS
ANGLES
# 0.02
# 0.005
# 1.0
FINISH DESCRIPTION
---
SCALE
1/10
PRODUCT LINE
ZENITH T-SERIES
SHEET
1 of 3

us_3rd_d.frm
18 17 16 15 14 13 12 11
28 27 26 25 24 23 22 21
3.5 1
[89] [23]
GUTTER GUTTER SPACE 4.3
SPACE [109]

PH-N

D PH-C
PH-C D
35.1
[892]
PH-B PH-B

PH-A PH-A

8.3 TOP VIEW 6.0


[153]
TOP VIEW
[211] PANEL REMOVED PANEL REMOVED
GUTTER (3 POLE UNIT) GUTTER SPACE (4 POLE UNIT)
SPACE AUXILIARY PANEL
'(FOR OPTIONS) AUXILIARY PANEL
'(FOR OPTIONS)
C
C

NEUTRAL BAR ASM


(PER VOLTAGE CONFIGURATION)

CONTROLLER
CONTROLLER

44.5
[1131]
WIRE BENDING
SPACE
(TOP)

19.0
B ATS [483]

SOURCE (S1)
POWER
PANEL
ATS
POWER PANEL B
SOURCE (S1)

LOAD (L)
10.1 LOAD (L)
[257]

19.0
Any unauthorized use, reproduction, distribution or disclosure to third parties is strictly forbidden.

SOURCE 2 (S2) [483]


ABB PROPRIETARY AND CONFIDENTIAL INFORMATION

SOURCE 2 (S2)
The information contained in the document has to be kept strictly confidential.

ABB reserves all rights regarding intellectual Property Rights.


Copyright 2021 ABB. All rights reserved

20.8
[529]
WIRE BENDING
SPACE
(BOTTOM)
NOTES:
1. SEE SHEET 1 FOR COMPLETE NOTES
2. MECHANICAL LUG SHOWN IN ABOVE VIEWS ARE FOR REFERENCE
A

GROUND BAR ASM


(REFERENCE ONLY)
LEFT SIDE VIEW GROUND BAR ASM
(REFERENCE ONLY)
PANEL REMOVED
AVAILABLE AS OPTION (3 POLE UNIT) AVAILABLE AS OPTION LEFT SIDE VIEW
EQUIPMENT EQUIPMENT PANEL REMOVED
GROUND LUG GROUND LUG (4 POLE UNIT) SIZE NUMBER REV
QTY-1 QTY-1 D 50C-1097 1
Third Angle Projection
(#2-600 MCM) (#2-600 MCM) SCALE PRODUCT LINE SHEET
1/8 ZENITH T-SERIES 2 of 3

28 27 26 25 24 23 22 21
38 37 36 35 34 33 32 31
48.1
[1221]

7.3
[185] .79
D [20,0]

D
4.9
[125]
35.5
[902]

12.3
[313]
A3/A4
TERMINAL BLOCK
FOR CUSTOMER
CONNECTION
31.3
[794] CONTROLLER
AUX PANEL LOCATION
FOR OPTIONS
TOP VIEW
PANEL REMOVED
C (4 POLE UNIT) 1.18

.69
[30,0]
C
[17,5]
.51
[13,0]
.98
[25,0] HEATER (OPTION)

3.15
[80,0]
ATS
POWER
PANEL
1.18
[30,0]

42.1
[1069]
47.6 DETAIL A OPERATING
[1210] SCALE 1/4 HANDLE
SEE DETAIL A

B
B
5.5 93.0
[140] [2362]

DOCUMENT
HOLDER
DOOR LOCKING MECHANISM
TO KEEP DOOR OPEN
5.5 25.3
Any unauthorized use, reproduction, distribution or disclosure to third parties is strictly forbidden.

[140] [642]
GROUND STUD
ABB PROPRIETARY AND CONFIDENTIAL INFORMATION

(IN DOOR)
The information contained in the document has to be kept strictly confidential.

GROUND LUG
OPERATING (REAR FACING)
HANDLE
ABB reserves all rights regarding intellectual Property Rights.

LOCATION
Copyright 2021 ABB. All rights reserved

ATS
POWER PANEL

24.1
[612]

NOTES:

1. REFER TO SHEET(1) FOR MORE DETIALS.


2. VIEW SHOWN ON THIS SHEET ARE WITHOUT LUGS.
LEFT SIDE VIEW 3. THIS CONFIGURATION CAN BE USED FOR BUS CONNECTION.
PANEL REMOVED SIZE NUMBER REV

Third Angle Projection (4 POLE UNIT) D 50C-1097 1


SCALE PRODUCT LINE SHEET
1/8 ZENITH T-SERIES 3 of 3

38 37 36 35 34 33 32 31