You are on page 1of 4

SMA LARGE SCALE SOLUTIONS

SMA
HYBRID
$0/530--&3

SMA plant management solutions


for seamless power integration

Optimal control of large scale PV projects


SMA plant control
0QUJNVNQFSGPSNBODFXJUIUIF4.")ZCSJE$POUSPMMFS

The SMA Hybrid Controller intelligently controls energy flows and enables seamless integration of renewable energies into power
grids. With the new diesel-off function, it operates micro grids based entirely on renewable energies and keeps the utility grid stable
even if strong fluctuations occur. The device automatically regulates all generators and storage systems according to the required load
profile, and takes on comprehensive grid management functions up to the provision of control reserve in large utility grids. Thanks to its
intuitive user interface, the SMA Hybrid Controller offers clearly structured configuration wizards and full transparency on energy flows.

Benefit from clean solar power:

• Meet grid operator requirements including primary control


reserve and frequency response
• Stable utility grid operation without generators or electricity
• Microgrid frequency and voltage control
• High-precision frequency and voltage measurement
ER
L A R POW • Control utility grid storage systems and generators
% SO DE
E W : 100 EL-OFF MO • Support for cloud cameras
N IES
FOR D

Cost-effective Scalable Flexible Robust

• Increases yields • Modular design for customiza- • The right configuration for every • Designed for harsh environ-
• Easy installation tion and system expansion system size ments
• Fast commissioning • A wealth of functions for • Storage systems can be • Fully tested industrial grade
• Remote monitoring and system various penetration levels integrated components
setting with SCADA
More flexibility for new opportunities
8FPGGFSWBSJPVTDVTUPNJ[FEDPOGJHVSBUJPOBOETZTUFNFYQBOTJPOQPTTJCJMJUJFT4.")ZCSJE
$POUSPMMFSNBOBHFTCPUIUIFTUPSBHFBOEQIPUPWPMUBJDTZTUFNTUPBDIJFWFUIFOFFEFE
GVODUJPOTGPSCPUIPOHSJEBOEPGGHSJEBQQMJDBUJPOT

• Feed-in management
• Grid services

• Renewable ramp rate control


• Frequency control
• Energy shifting

• Frequency & voltage control


• Genset spinning reserve
• Diesel off mode
• Optimized genset operation

• Dispatch of PV power to
match load demands • Peak load shaving
• Increase in self-consumption • Energy shifting
• Active & reactive power control • Time of use management
SMA Hybrid Controller
TECHNICAL DATA
Hybrid Controller Hybrid Controller Hybrid Controller Hybrid Controller
Small Medium Large X-Large

General System Design


System size (PV system size) up to 750 kW up to 2000 kW unlimited unlimited
Maximum number of devices1) total max. 40 max. 1208) max. 1208) max. 1608)
PV inverters max. 32 max. 120 max. 120 max. 120
Gensets max. 8 max. 16 max. 16 max. 16
Battery inverter − max. 32 max. 32 max. 64
External measurement (DAQ / Janitza / more upon request) − max. 10 max. 10 max. 20
Irradiation sensors max. 2 max. 2 max. 2 max. 2
General Data
Dimensions (W x H x D) in mm (approx.) 760 x 760 x 210 760 x 760 x 210 760 x 760 x 210 upon request
Weight (approx.) 48 kg
Degree of protection in accordance with DIN EN 60529 IP 65
Ambient Conditions
Operating temperature range –20°C to +50°C
Maximum operating altitude 2000 m above mean sea level2)
Humidity 5% to 95% (non-condensing)
Power supply
Voltage supply (nominal value) 110 Vac to 240 Vac, 50 Hz / 60 Hz
Power consumption (max. / average) 200 W / 120 W
Communication
System communication for system monitoring, SCADA and remote Modbus / TCP, HTTP, FTP over Ethernet
monitoring 10 BASE-T and 100 BASE-T(X)
Communication between the devices Ethernet 100BASE-FX and TX2)
Supported communication protocols IEC 60870-5-104; IEC 60870-5-1017); IEC 60870-5-1037); IEC 618507); IEEE1815 (DNP3)7)
Communication to inverters / maximum cable length Sunny Central: Ethernet 100BASE-TX or 100BASE-FX (optional) /
Sunny Tripower: 100BASE-TX
Communication protocol to genset controllers Modbus / TCP Master via Ethernet 100BASE-FX and TX or CAN / CANOpen3)
Communication devices Unmanaged switch Routing switch, supporting a remote access and VPN
Other Interfaces
Multi-functional digital inputs for potential-free contacts 10 10 10 upon request
Power measurement
Integrated current measurements: 1 A4) at the sensor input5) 4 4 6 upon request
Integrated voltage measurement: 480 V voltage input 2 2 3 upon request
SMA FSC-11-DAQ, UMG 604 JANITZA6),
Compatible external power measurement No upon request
ION PowerLogic 7650/7750/8600/8800
Visualization & data recording
Visualization and configuration interface Web interface for local and remote monitoring
Data / event recording 10 second values for 30 days (changeable) / by events
Compatible inverters
Inverters Sunny Tripower (STP TL-30, STP US-10, STP Sunny Tripower (STP TL-30, STP US-10, STP
60-10, STP50-40), Sunny Tripower Storage7), 60-10, STP50-40), Sunny Tripower Storage,
Sunny Highpower Peak1 Sunny Highpower Peak1,
Sunny Central CP-XT, Sunny Central,
Sunny Central Storage
1)
Different distribution via customer-specific software is an option
2)
Individual altitude, cable length upon request
3)
Protocol implementation upon request
4)
5A sensor available upon request
5)
Up to 100 m cable length
6)
Not included in the scope of delivery of SMA
7)
Upon request
8)
Die maximale Anzahl der Geräte ist von den projektspezifischen Anforderungen an die
Regelungsfunktionen und den erwarteten Zykluszeiten abhängig.
Type designation HYBRID CONTROLLER