Professional Documents
Culture Documents
SNO-I-DS-005
LEVEL TRANSMITTER REV. 0 Page 2 of 154
SENORO GAS DEVELOPMENT PROJECT DATE. 16-Apr-14
REVISION SUMMARY
No. Tag No. EA P&ID No. No. Tag No. EA P&ID No. No. Tag No. EA P&ID No.
1 LT-6001A 1 SNO-R-PI-020 66 LT-1105I 1 SNO-R-PI-007 131 LTZ-3204C 1 SNO-R-PI-413
2 LTZ-6001B 1 SNO-R-PI-020 67 LT-1205I 1 SNO-R-PI-042 132 LT-3104A 1 SNO-R-PI-403
3 LT-6001C 1 SNO-R-PI-021 68 LTZ-1105L 1 SNO-R-PI-007 133 LT-3204A 1 SNO-R-PI-413
4 LTZ-6001D 1 SNO-R-PI-021 69 LTZ-1205L 1 SNO-R-PI-042 134 ILTZ-3110A 1 SNO-R-PI-404
5 LT-7002A 1 SNO-R-PI-031 70 LT-1105K 1 SNO-R-PI-007 135 ILTZ-3210A 1 SNO-R-PI-414
6 LTZ-7002B 1 SNO-R-PI-031 71 LT-1205K 1 SNO-R-PI-042 136 ILT-3110F 1 SNO-R-PI-404
7 LT-6010A 1 SNO-R-PI-034 72 LTZ-1105A 1 SNO-R-PI-007 137 ILT-3210F 1 SNO-R-PI-414
8 LTZ-6010B 1 SNO-R-PI-034 73 LTZ-1205A 1 SNO-R-PI-042 138 LT-3110B 1 SNO-R-PI-404
9 LT-6010C 1 SNO-R-PI-034 74 LT-1105C 1 SNO-R-PI-007 139 LT-3210B 1 SNO-R-PI-414
10 LTZ-6010D 1 SNO-R-PI-034 75 LT-1205C 1 SNO-R-PI-042 140 LTZ-3105C 1 SNO-R-PI-405
11 LT-6020A 1 SNO-R-PI-034B 76 LTZ-1105F 1 SNO-R-PI-007 141 LTZ-3205C 1 SNO-R-PI-415
12 LTZ-6020B 1 SNO-R-PI-034B 77 LTZ-1205F 1 SNO-R-PI-042 142 LT-3105B 1 SNO-R-PI-405
13 LT-6020C 1 SNO-R-PI-034B 78 LT-1105E 1 SNO-R-PI-007 143 LT-3205B 1 SNO-R-PI-415
14 LTZ-6020D 1 SNO-R-PI-034B 79 LT-1205E 1 SNO-R-PI-042 144 LTZ-4027C 1 SNO-R-PI-713
15 LT-9051A 1 SNO-R-PI-114 80 ILT-6103E 1 SNO-R-PI-013 145 LT-4027B 1 SNO-R-PI-713
16 LTZ-9051A 1 SNO-R-PI-114 81 ILT-6203E 1 SNO-R-PI-048 146 LT-6077A 1 SNO-R-PI-153
17 LTZ-8136D 1 SNO-R-PI-136 82 LTZ-6040G 1 SNO-R-PI-015 147 ILT-6112A 1 SNO-R-PI-060
18 LTZ-8236D 1 SNO-R-PI-136B 83 LTZ-6040A 1 SNO-R-PI-015 148 ILT-6212A 1 SNO-R-PI-061
19 LT-8136C 1 SNO-R-PI-136 84 LT-6040I 1 SNO-R-PI-015 149 -
20 LT-8236C 1 SNO-R-PI-136B 85 LT-6040C 1 SNO-R-PI-015 150 -
21 LTZ-6077B 1 SNO-R-PI-153 86 LTZ-6040L 1 SNO-R-PI-015
22 LT-2020B 1 SNO-R-PI-321 87 LTZ-6040F 1 SNO-R-PI-015
23 LTZ-2020A 1 SNO-R-PI-321 88 LT-6040K 1 SNO-R-PI-015
24 LT-3019B 1 SNO-R-PI-421 89 LT-6040E 1 SNO-R-PI-015
25 LTZ-3019A 1 SNO-R-PI-421 90 LT-5041C 1 SNO-R-PI-057
26 ILTZ-6101A 1 SNO-R-PI-008 91 LT-5041H 1 SNO-R-PI-057
27 ILTZ-6201A 1 SNO-R-PI-043 92 LTZ-5041L 1 SNO-R-PI-057
28 ILT-6101B 1 SNO-R-PI-008 93 LTZ-5041M 1 SNO-R-PI-057
29 ILT-6201B 1 SNO-R-PI-043 94 LT-5041F 1 SNO-R-PI-057
30 LTZ-6074A 1 SNO-R-PI-010D 95 LT-5041K 1 SNO-R-PI-057
31 LT-6074B 1 SNO-R-PI-010D 96 LTZ-5040E 1 SNO-R-PI-057
32 ILT-6107F 1 SNO-R-PI-014 97 LT-5040D 1 SNO-R-PI-057
33 ILT-6207F 1 SNO-R-PI-049 98 LT-8063H 1 SNO-R-PI-102
34 ILTZ-6107G 1 SNO-R-PI-014 99 LT-8063D 1 SNO-R-PI-102
35 ILTZ-6207G 1 SNO-R-PI-049 100 LT-8063F 1 SNO-R-PI-102
36 LTZ-6031A
LTZ 6031A 1 SNO-R-PI-037
SNO R PI 037 101 LT-8063B
LT 8063B 1 SNO-R-PI-102
SNO R PI 102
37 LT-6031B 1 SNO-R-PI-037 102 LT-8070B 1 SNO-R-PI-132
38 LTZ-8049C 1 SNO-R-PI-106B 103 LT-8070H 1 SNO-R-PI-132
39 LT-8049B 1 SNO-R-PI-106B 104 LT-8070D 1 SNO-R-PI-132
40 LT-9022A 1 SNO-R-PI-128 105 LT-8070F 1 SNO-R-PI-132
41 LTZ-9022B 1 SNO-R-PI-128 106 LTZ-3102H 1 SNO-R-PI-401
42 LT-2124C 1 SNO-R-PI-323 107 LTZ-3202H 1 SNO-R-PI-411
43 LT-2224C 1 SNO-R-PI-324 108 LT-3102B 1 SNO-R-PI-401
44 LTZ-2124D 1 SNO-R-PI-323 109 LT-3202B 1 SNO-R-PI-411
45 LTZ-2224D 1 SNO-R-PI-324 110 LTZ-3102D 1 SNO-R-PI-401
46 LT-3121C 1 SNO-R-PI-422B 111 LTZ-3202D 1 SNO-R-PI-411
47 LT-3221C 1 SNO-R-PI-423B 112 LT-3102E 1 SNO-R-PI-401
48 LTZ-3121D 1 SNO-R-PI-422B 113 LT-3202E 1 SNO-R-PI-411
49 LTZ-3221D 1 SNO-R-PI-423B 114 LTZ-3116D 1 SNO-R-PI-402A
50 LTZ-4024C 1 SNO-R-PI-711 115 LTZ-3216D 1 SNO-R-PI-412A
51 LT-4024D 1 SNO-R-PI-711 116 LT-3116B 1 SNO-R-PI-402A
52 LT-6070B 1 SNO-R-PI-010B 117 LT-3216B 1 SNO-R-PI-412A
53 LT-6070D 1 SNO-R-PI-010B 118 LTZ-3116G 1 SNO-R-PI-402A
54 LTZ-6070A 1 SNO-R-PI-010B 119 LTZ-3216G 1 SNO-R-PI-412A
55 LTZ-6070C 1 SNO-R-PI-010B 120 LT-3116E 1 SNO-R-PI-402A
56 ILTZ-1102A 1 SNO-R-PI-005 121 LT-3216E 1 SNO-R-PI-412A
57 ILTZ-1202A 1 SNO-R-PI-040 122 LTZ-3116J 1 SNO-R-PI-402B
58 ILT-1102C 1 SNO-R-PI-005 123 LTZ-3216J 1 SNO-R-PI-412B
59 ILT-1202C 1 SNO-R-PI-040 124 LT-3116H 1 SNO-R-PI-402B
60 ILTZ-1104A 1 SNO-R-PI-006 125 LT-3216H 1 SNO-R-PI-412B
61 ILTZ-1204A 1 SNO-R-PI-041 126 LTZ-3116M 1 SNO-R-PI-402B
62 ILT-1104C 1 SNO-R-PI-006 127 LTZ-3216M 1 SNO-R-PI-412B
63 ILT-1204C 1 SNO-R-PI-041 128 LT-3116K 1 SNO-R-PI-402B
64 LTZ-1105G 1 SNO-R-PI-007 129 LT-3216K 1 SNO-R-PI-412B
65 LTZ-1205G 1 SNO-R-PI-042 130 LTZ-3104C 1 SNO-R-PI-403
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA8SPVEAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I18SPVEAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA8SPVEAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I18SPVEAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) N/A
8 Instrument Type Radar with Stilling Well
9 Equipment Height 504 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4SPVCAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) N/A
8 Instrument Type Radar with Stilling Well
9 Equipment Height 504 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14NPVCAM1T1C1Q4Q8N2QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 600 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA8SPVEAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 600 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I18SPVEAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 600 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA8SPVEAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 600 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I18SPVEAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA8SPVEAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model VTA
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I18SPVEAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 576 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I18SPVEAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1M -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 360 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4SPVCAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : 316SS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B8M CL.2 / A194 8M
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1M -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 360 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : 316SS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B8M CL.2 / A194 8M
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 72 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14NPVCAM1T1C1Q4Q8N2QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : 316SS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B8M CL.2 / A194 8M
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 72 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14NPVCAM1T1C1Q4Q8N2QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : 316SS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B8M CL.2 / A194 8M
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 72 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4NPVCAM1C1Q4Q8N2P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : 316SS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B8M CL.2 / A194 8M
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 72 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4NPVCAM1C1Q4Q8N2P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : 316SS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B8M CL.2 / A194 8M
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 480 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7 / A194 2H
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1B -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 360 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4NPVCAM1C1Q4Q8N2P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1B -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 360 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14NPVCAM1T1C1Q4Q8N2QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 100 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4SPVCAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 752
- Signal Type : Foundation Fieldbus
- Surge Protector : Yes
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 100 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1N 2 inch 1N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302HA1S1E4AM00203BAI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1N 2 inch 1N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302HA1S1E4AM00203BAI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1N 2 inch 1N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302FA1S1E4AM00122BAIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1N 2 inch 1N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302FA1S1E4AM00122BAIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1B 4 inch 1B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1V4AM00280CAI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1B -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00280CAIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302FA1S1E4AM00149BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302FA1S1E4AM00149BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5302HA1S1E4AM00149BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1E4AM00280CAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1H1N4AM00274CAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1H1N4AM00274CAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 165 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4SPVCAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 165 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
44 FISCO Certificate No
45 Material Tagging Plate 316 SS
46 Calibration Report / Certificate Yes
47 Explosion Proof Ex i
48 SIL Yes
49 Manufacturer Rosemount
PURCHASE
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301FA1S1V4BM00380CAIAM1P1C1Q4Q8Q66N2
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301FA1S1V4BM00380CAIAM1P1C1Q4Q8Q66N2
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar with stilling well
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301HA1S1V4BM00380CAI1M1P1C1Q4Q8Q66QSN2T1
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1N -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar with stilling well
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301HA1S1V4BM00380CAI1M1P1C1Q4Q8Q66QSN2T1
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar with stilling well
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301FA1S1V4AM00200CAIAM1P1C1Q4Q8Q66
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar with stilling well
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301FA1S1V4AM00200CAIAM1P1C1Q4Q8Q66
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar with stilling well
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301HA1S1V4AM00200CAI1M1P1C1Q4Q8Q66QST1
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar with stilling well
9
10 Upper Liquid State Dielectric Constant - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301HA1S1V4AM00200CAI1M1P1C1Q4Q8Q66QST1
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3A 2 inch 3A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301HA1H1N4AM00107BCI1M1P1C1Q4Q8Q66QST1
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3A 2 inch 3A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5300
56 Serial Number 5301FA1H1N4AM00107BCIAM1P1C1Q4Q8Q66
57 Requisition Number SNO-I-RQ-024
58 Purchase Order Number 4500136690
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permenantly attached with SS Screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrument Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1B -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 504 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4SPVCAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1B -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 504 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
50 Model 5401AF1IA4SPVCAM1C1Q4Q8P1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1B -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 504 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
44 FISCO Certificate No
45 Material Tagging Plate 316 SS
46 Calibration Report / Certificate Yes
47 Explosion Proof Ex i
48 SIL SIL2
49 Manufacturer Rosemount
PURCHASE
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 8 inch 1B -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) Yes
8 Instrument Type Radar with Stilling Well
9 Equipment Height 504 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
44 FISCO Certificate No
45 Material Tagging Plate 316 SS
46 Calibration Report / Certificate Yes
47 Explosion Proof Ex i
48 SIL SIL2
49 Manufacturer Rosemount
PURCHASE
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00127BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00127BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00127BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00127BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) NACE
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00127BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) NACE
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00127BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00127BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00127BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00097BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00097BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00097BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00097BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00102BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00102BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175)
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175)
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00097BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00097BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00097BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00097BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00102BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00102BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 9N 2 inch 9N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3R 2 inch 3R
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1HDN4BM00143BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3R 2 inch 3R
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1HDN4BM00143BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1E4AM00097BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1E4AM00097BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1E4AM00097BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1E4AM00097BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1E4AM00097BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1E4AM00097BBI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1E4AM00097BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3N 2 inch 3N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1E4AM00097BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BCIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BCIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00102BCI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00102BCI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BCIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00102BCIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00112BCI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00112BCIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3B 2 inch 3B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00097BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3B 2 inch 3B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00097BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3B 2 inch 3B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00092BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 3B 2 inch 3B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00092BBIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1B 2 inch 1B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1V4AM00097BAI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1B 2 inch 1B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1V4AM00097BAI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1B 2 inch 1B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00097BAIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1B 2 inch 1B
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00097BAIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00127BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00127BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) No
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00127BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) No
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00127BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) No
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00137BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) No
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00137BJI1M1P1C1Q4Q8Q66QSN2T1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) No
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00137BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) No
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00137BJIAM1P1C1Q4Q8Q66N2
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00099BJI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00099BJI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00099BJIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00099BJIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00099BJI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00099BJI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00099BJIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00099BJIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00099BJIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1P1N4AM00099BJIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00099BJI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 6A 2 inch 6A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1P1N4AM00099BJI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1H1N4AM00186BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1H1N4AM00186BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1H1N4AM00127BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1H1N4AM00127BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1V4AM00169BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1V4AM00169BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00132BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant HC Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00132BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00097BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00097BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1H1N4AM00289BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1H1N4AM00289BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1H1N4AM00177BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1H1N4AM00177BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301HA1S1V4AM00267BAI1M1P1C1Q4Q8Q66QST1
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1A 2 inch 1A
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) N/A
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant - - -
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model 5301FA1S1V4AM00192BAIAM1P1C1Q4Q8Q66
56 Requisition Number SNO-I-RQ-024
57 Purchase Order Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equipment Nozzle and Piping Spec. Upper Lower 4 inch 1A -
5 Hazadous Area Classification Zone-2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement(MR0175) No
8 Instrument Type Radar with Stilling Well
9 Equipment Height 480 inch
10 Upper Liquid State Dielectric Constant - - -
PROCESS CONDITION
44 FISCO Certificate No
45 Material Tagging Plate 316 SS
46 Calibration Report / Certificate Yes
47 Explosion Proof Ex i
48 SIL SIL2
49 Manufacturer Rosemount
PURCHASE
50 Model 5401AH1I14SPVCAM1T1C1Q4Q8QSP1
51 Requisition Number SNO-I-RQ-024
52 Purchase Order Number 4500136690
53
54
Notes :
1. Above mentioned measuring range is a dimension from the flange face.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation systems
4. Spool shall be supplied by Vendor. Material shall refer to SNO-P-GS-001 Specification for Piping Material Class
- Spool Material : CS with NACE (150#)
- Gasket : Spiral wound gasket with inner & center ring, composed of 316SS hoop with F.Graphite filler and 316SS inner ¢er ring.
- Bolt / Nut : A193 B7M / A194 2HM
- Valve : N/A
5. Remote Indicator at ground : Yes
- Model No. : Rosemount 751
- Signal Type : 4~20mA with HART
- Surge Protector : Yes
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1N 2 inch 1N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant Hydrocarbon Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower 2 inch 1N 2 inch 1N
5 Hazadous Area Classification Zone 2, Gr.IIB, T3
6 Ingress Protection IP 65
7 NACE Requirement (MR0175) Yes
8 Instrument Type Guided Wave Radar
9
10 Upper Liquid State Dielectric Constant Hydrocarbon Liquid 2.1
CONDITION
38 Mounting Direct
39 Power Supply 24 VDC Loop Powered
TRANSM
55 Model VTA
56 Requisition Number SNO-I-RQ-024
57 Purchase Number 4500136690
58
59
Notes :
1. Vent and Drain Valve with nipple & blind flange shall be provided as per Piping Specification.
2. Tagging Plate shall be permanently attached with SS screws or wired.
3. This data sheet shall refer to SNO-I-ES-001, Standard Specification for Engineering & Design of Instrumentation Systems
4. Remote Indicator at ground : N/A
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower
5 Hazadous Area Classification
6 Ingress Protection
7 NACE Requirement (MR0175)
8 Instrument Type
9
10 Upper Liquid State Dielectric Constant
CONDITION
31 Insertion Length
32 Inactive Length Lower Upper
33
34
35 Function
36 Range
37 Output Action @ Level Rise
MITTER
38 Mounting
39 Power Supply
TRANSM
40 Output Signal
41 Dielectric Range
42 Electric Connection
43 Accuracy
44 Display
45
46 Local Indicator
47 Self-Test
48 Lightning Protection
OPTION
49 FISCO Certificate
50 Material Tagging Plate
51 Calibration Report / Certificate
52 Explosion proof
53 SIL Certificate
54 Manufacturer
PURCHASE
55 Model
56 Serial Number
57 Requisition No.
58
59
Notes :
1. LT-6078A is changed to DP (Capillary Type) because SNO-V-6078 is changed from horizontal to vertical type.
GENERAL
4 Equip. Nozzle Size and Piping Spec. Upper Lower
5 Hazadous Area Classification
6 Ingress Protection
7 NACE Requirement (MR0175)
8 Instrument Type
9
10 Upper Liquid State Dielectric Constant
CONDITION
31 Insertion Length
32 Inactive Length Lower Upper
33
34
35 Function
36 Range
37 Output Action @ Level Rise
MITTER
38 Mounting
39 Power Supply
TRANSM
40 Output Signal
41 Dielectric Range
42 Electric Connection
43 Accuracy
44 Display
45
46 Local Indicator
47 Self-Test
48 Lightning Protection
OPTION
49 FISCO Certificate
50 Material Tagging Plate
51 Calibration Report / Certificate
52 Explosion proof
53 SIL Certificate
54 Manufacturer
PURCHASE
55 Model
56 Serial Number
57 Requisition No.
58
59
Notes :
1. LTZ-6078B is changed to DP (Capillary Type) because SNO-V-6078 is changed from horizontal to vertical type.