Pune Techtrol

Private Limited

TECHTROL LEVEL CONTROLLER


“TLC”
TLC is used for remote level indication & control

It is available in three types TLC-F or TLC-M or TLC-N. The controller TLC-F is used with the
float switches and TLC-M with magnetic switches of Magnetic Level Gauges, having reed type
switching contacts. It amplifies the power ratings of reed switches to 5A @250 VAC through its
relay output. The controller TLC-N is used alongwith the probe in conductivity switch.

Dimensions and Mounting Details

7272 68 68
N N
TLC-TLC-
LEVEL
LEVEL CONTROLLER
CONTROLLER L N EL CN 1E 2C 3 1 4 2 3 4

To probeTo probe
Supply Supply

7272 68 68
SUPPLY
SUPPLY R1 R1
R2 R2
R3 R3
R4 R4
RL1 RL1
RL2 RL2
RL3 RL3
RL4 RL4
NO
NO P NC P PNCNC
NO NONO
P PNC
NCNO
NOP PNCNC
NO P NC

www.punetechtrol.com
www.punetechtrol.com

FRONT
FRONT VIEW
VIEW REAR
REARVIEW
VIEW (CUTOUT)
(CUTOUT)
Panel Mounted Front view Rear view (Cutout)

CC 164
132

TLC- F
LEVEL CONTROLLER

www.punetechtrol.com 25
147

Ø7x2 nos
Mtg. Hole

PG11 Gland

Wall Mounted (W.proof) Front view Rear view

150 CC 135
150 CC 135

FLAMEPROOF ENCLOSURE
CC 135
150

FLAMEPROOF ENCLOSURE
CC 135
150
215

215

Ø9.5 X 4 NOS
Ø9.5 X 4 NOS
Mtg holes
1/2" NPT Mtg holes
1/2" NPT
DC Gland
DC Gland
FRONT VIEW REAR VIEW
Wall Mounted (Ex-proof) Front viewVIEW
FRONT Rear view
REAR VIEW

WE MEASURE THE BEST FOR YOU! 01


Pune Techtrol
Private Limited
SPECIFICATIONS

Model TLC-F or TLC-M TLC-N


Potential free contacts of FGS, MFGS, MFPS
Input (Product Series) CNS probe
or Magnetic Switch of MLG
Input Signal Voltage 24 VDC 6 VAC, 20 mA
Power Supply 90 – 270 VAC or 24 VDC, ± 10 %
No. of Set Points Two or Four

Relay Outputs 2 x SPDT or 4 x SPDT or 2 x DPDT (Potential free relay contacts rated for 5A, 250 VAC )
4 x DPDT with two controller units
Relay Latching Field settable through DIP switch between L1 & L2 ; L3 & L4
Fail Safe Operation NA FSH or FSL through DIP switch setting
LED Indications Green‐ Supply, Red– Alarm (Relay On status)
Delay Time 2 sec
Power Consumption < 3 VA (90 - 270 VAC), 8 VA (24 VDC) < 10 VA
Terminals Suitable for 1.5 mm2 conductor size

1. ABS Panel Mounted IP41 (Size 72 x 72 x 130 D mm)


Enclosure x
Cable Entry 2. Cast Al. powder ctd. IP66, wall mtd. (Size 147 x 132 x 80 H mm) x PG11 Cable Gland, Polyamide
3. Cast Al. powder ctd. Exd. Gr. IIB, wall mtd. (Size 150 x 150 x 122 H mm) 1/2" NPT DC Cable Gland, Brass

Ambient Temperature 0 to 55 0 C
Humidity 90 % Rh (Non condensing)

CE Certification For Panel Mounted TLC-F and TLC-M

Note : Control Panels with Customized Logic for Pump Automation with Auto/ Manual Facility and Hooter with Reset
Function are available on demand.

TERMINATION
Potential Free Relay O/P Contacts

RL1 RL2 RL3 RL4

L N E C 1 2 3 4 NO P NC NO P NC NO P NC NO P NC
Supply Lamp

To switch or Hooter
Conductivity Probe
L

Contactor (Motor)

Terminal Configuration for 4 Set Points

WE MEASURE THE BEST FOR YOU! 02


Pune Techtrol
Private Limited
MODEL IDENTIFICATION

TLC -
1. Product Series
FGS/MFGS/MFPS F
MLG M
CNS N
2. Enclosure x Cable Entry
ABS Panel Mtd. IP41 P

Cast Al. IP66 Wall Mtd. x PG11 Cable Gland J

Cast Al. Exd Gr. IIB, Wall Mtd. x 1/2" NPT DC Cable Gland E

Others O
3. Power Supply
90 to 270 VAC 1
24 VDC 2
4. No. of Set Point x Relay Output
Two x SPDT 2
Four x SPDT 4
Two x DPDT 6
Four x DPDT (with 2 controller unit) 8
Other O
5. Relay Latching
No N
Yes Y

PUNE TECHTROL PRIVATE LIMITED


CIN: U31909PN1997PTC063403

Regd. & Sales: S-18, MIDC Bhosari, Pune - 411026, India Works: J-52/7, MIDC Bhosari, Pune - 411026, India
+91-20-66342900 | ho@punetechtrol.com +91-20-67313600 | www.punetechtrol.com

WE MEASURE THE BEST FOR YOU! CAT/0047/REV 05/12-2021 03

You might also like