Specification for the JS PureFlo™ RO-100 Reverse Osmosis System
“The revolutionary low pressure high output membrane system”
12. The membranes and carbon/sediment filters shall be housed in
1. The RO 100 system must be safe to use and fully CE filter housings that are easily accessible to facilitate marked to comply with ‘New Approach’ CE maintenance. directives.
13. The RO system must be capable of storing up to 25 litres of
2. The RO 100 system shall produce pure water by the immediately deliverable product water. This is typically process of Reverse Osmosis filtration under necessary for the purposes of filling humidifier water tanks, pressure of 2.8 – 5.5 bar gauge. The semi permeable reservoirs or pipe lines. filtration membranes shall have a recovery rate of at least 30%. 14. The RO system shall incorporate pressure gauges, with 3. The RO 100 system must be capable of typically minimum and maximum pressure markings for visual indication producing 100 litres per hour of product water. This of inlet water pressure and system pressure. figure is dependent upon incoming water pressure.
15. There shall be an option for an additional inlet water booster
4. The RO 100 system must incorporate low pressure pump set for conditions where the supply pressure is below the membranes. These new technology membranes are minimum of 2.8 bar. This shall be wall mountable and have dry capable of producing high product water output at run protection for the pump. very low cost saving water pressures.
16. There shall be an option for an additional product water
5. The system must be capable of operating on supply booster pump set for applications the inlet water pressure is water pressure alone. This pressure must be insufficient for the flow required. This pump shall boost the inlet between 2.8 bar (40psi) to 5.5 bar (80psi). Where this water pressure by up to 5 bar. supply pressure is not available the optional pressure booster pump set should be fitted. 17. The unit shall include a test point for the purposes of checking water quality and membrane performance. 6. The system shall start and stop producing product water based on water pressures within the system alone, therefore not requiring any power supply. All 18. The RO 100 shall be supplied with a drain/bleed point for operational valves shall be mechanically pressure manual draining down activated, which negates the requirements for electrically operated controls. 19. The pipe diameters shall be as follows • 15mm or 1/2”BSP connection for the water inlet 7. The RO 100 shall be supplied pre-assembled with the • 15mm or 1/2”BSP for the drain 2 minimum footprint of 0.35m . • 15mm or ½”BSP for the product water outlet.
8. The RO 100 system must have the capability to reject
at least 90 % of Total Dissolved Solids (TDS). 20. The installation of the system should be within 10 meters of the application. For further distances the integral product water booster pump option should be considered. 9. The water treatment system shall be supplied with automatic membrane preservation flush. This innovative process collects and stores pure treated 21. The supplier must be registered under the Code of water during operation and uses it to flush the Conduct for Service Providers Scheme for water membranes whenever the system stops. This will treatment products preserve the life of the membranes. The system is to be supplied by: JS Humidifiers plc, 10. The RO 100 shall be provided with the facility to Artex Ave, Rustington, connect multiple units together in order achieve Littlehampton, West Sussex. higher product water duties. BN16 3LN, UK Tel. 01903 850 200 Fax. 01903 850 345. email: sales@jshumidifiers.com 11. The system shall incorporate a sediment filter to website: www.jshumidifiers.com remove waterborne particles. The sediment filter must 16/11/05 Ver1 be a minimum of 5 micron filtration.
www.jshumidifiers.com RO 100 Specifications at a glance…..
Product Water Flow Rate
140 RO-100 Reverse Osmosis System 120 Product water output 39-122 l/h Product Flow (l/h)
Water inlet pressure (@450l/h) 2.8-5.5 bar 100
Rejection (typical) TDS 90% 80 Recovery 25-33% 5°C -37°C 60 Water inlet temperature Inlet water quality (TDS) 50-2000ppm 40 Inlet water flow <450l/h 20 Chlorine tolerance 0 - 0.1ppm Water storage 23 litres 0 Weight (dry) 27kg 2.8 3.9 4.8 5.5 Weight (operating) 55kg Supply water pressure (bar) Water inlet connection ½” BSP Drain connection ½” BSP Optional booster pump set specification Product water connection ½” BSP Power requirements 230V 50Hz 0.25kW Height 840mm Water inlet pressure 0.25 – 4 bar Width 750mm Water outlet pressure 5.3 bar Depth 445mm Water inlet connection 15mm