Application
Customer specific.
Standards
Cern IS23
Flame Resistance
IEC 60332-1, IEC 60332-3-24, IEC 60754-2, IEC 61034
Construction
Conductor bare copper wire, 6.66 ± 0.02
Insulation PE, 23.1 ± 0.2 mm,
Outer Conductor Bare copper braid, optical coverage approx. 95%, 24.2 ± 0.4 mm
Fire barrier wrapping copper foil, 24.4 mm
Wrapping PET – foil, 24.6 mm
Sheath LSFRZH, 31.0 ± 0.5 mm
Marking tbd
Mechanical properties
Bending radius operation ≤ 400 mm
installation ≤ 600 mm
Temperature range
Transport and storage - 25°C to + 60°C
Installation and operation +10°C to + 50°C
Radiation resistance 106 Gy (= 108 rad)
RG220_50_Ohm_e
LINKING THE FUTURE www.prysmiangroup.com Version 1.1 | 16.08.2017
Page 1 of 2
HV-Pulse Cable RG220/U 50 Ohm FRNC-C
Electrical data at 20°C
Frequency Max. Attenuation
(MHz) (dB/km)
0.1 0.5
1 MHz 1.7
10 MHz 5.7
30 MHz 10.0
Technical data
Part Design Type Product Outer Linear Max. delivery Drum Copper Tensile
number name diameter Weight Length Size content force
mm kg/km m *OWD N
6.66/ RG220/U 50 1700/1050
60021908 2YC(St)H 31.0 1430 500 655 2550
23.1 Ohm FRNC-C /1100
*OWD (One Way Drum)
RG220_50_Ohm_e
LINKING THE FUTURE www.prysmiangroup.com Version 1.1 | 16.08.2017
Page 2 of 2