Professional Documents
Culture Documents
The Modular Compact Rheometer Series: Product Name MCR Evolution
The Modular Compact Rheometer Series: Product Name MCR Evolution
Rheometer series
MCR
Product name
Evolution
MCR: Your Rheometers from the market leader
future-proof
rheometer 10,000+ installations worldwide
15 rheometer models
14 RheoCompass software
MORE THAN 30
SUBSIDIARIES PROVIDE
QUALIFIED SUPPORT ALL
OVER THE WORLD
Anton Paar started as a
one-man machine repair
APPROX. 97 % OF CRITICAL
workshop in Graz (Austria)
OVER 25 YEARS OF EC
MOTOR TECHNOLOGY
PA R T S P R O D U C E D I N - H O U S E back in 1922 and now has
A N D C U S T O M I Z AT I O N O N over 3400 employees and a
MORE THAN 10,000 OFFER
I N S TA L L AT I O N S W O R L D W I D E
worldwide service network of
Your rheological investigations more than 30 subsidiaries and
CHOOSE FROM demand the highest measuring At Anton Paar we take quality numerous responsible partners.
MCR is the most-used 15 RHEOMETER MODELS sensitivity. To achieve this, the very seriously. Our rheometers This means that an expert on
AND MORE THAN
rheometer worldwide. Highly 200 ACCESSORIES
MCR’s EC motor (Permanent are produced at the company’s your system is always close by.
satisfied with their MCR Magnet Synchronous Motor) headquarters in Austria with Anton Paar is the first choice
rheometers, thousands of users with integrated normal force more than 97 % of all critical for answering any rheological
have been with us from the very Anton Paar has the broadest sensor has exceptional mechanical parts manufactured question you may have. We
beginning and have been using portfolio on the market. low-torque capabilities down in-house, ensuring a secure are proud of our reputation for
their MCRs for decades. Around This includes 15 different to 0.0005 µNm, which can supply in case you need parts excellent service and support
the globe our instruments are at rheometers that can be be compared to the load of or accessories at a later date. and look forward to being your
work in R&D and academia as combined with over 200 a single human hair on an As our production facilities reliable partner. Call us for
well as in industrial laboratories different accessories giving you extended arm. Anton Paar was are just next door to the R&D advice on test definitions or to
measuring substances ranging endless possibilities in the field the first company to employ department, in which we invest discuss different approaches to
from paints and coatings, of rheological characterization. an EC motor in a rheometer 20 % of our turnover each solving a measuring problem.
polymers, food, automotive Each accessory extends the over 25 years ago. This motor year, we can also customize Our experts are just a phone
liquids, and petrochemicals to capabilities of the rheometer reached sensitivity values that and develop products for your call away and happy to help,
building materials, adhesives, and can easily be exchanged or were previously unthinkable and specific applications. Talk to us in your local language and free
and many more. added even years later. is still unrivaled today. about your special requirements. of charge.
www.anton-paar.com/apb-company
4 5
19 The best
95 now
A F I N E S E L E C T I O N O F F I R S T- T I M E
U N I Q U E R H E O M E T E R I N N O VAT I O N S :
1995
better
- EC motor and the modular rheometer concept
with UDS 200
- Controlled stress, shear rate, and strain in
one rheometer
- QuickConnect coupling
1996
- Normal force sensor principle
(US Pat. 6167752, 1996)
1999
- Peltier hood (US Pat. 6571610, 1999)
and cylinder temperature control
(US Pat. 6240770, 1999)
- Direct-strain oscillation (DSO, TruStrain™)
- Automatic sample changer for automated
measurement
2004
- Unique and still unrivaled features: 20
21 MCR
Toolmaster™ (US Pat. 7275419, 2004),
TruGap™ (US Pat. 6499336, 2000)
- CTD 1000 for measurements up to 1000 °C
- Setups for tribology Evolution –
- High-throughput rheometer (HTR) Easiest possible coupling and decoupling of measuring systems with one
2011
what is new? hand even at extreme temperatures (-160 °C to 1000 °C): novel quick-
connect mechanism
- T-Ready™ for detection of sample equilibrium
time (US Pat. 8904852, 2011)
Precisely measure even low-viscosity samples with our most compact
2012 rheometer model: Higher sensitivity with MCR 102e (from 7.5 nNm
- Pressure Cell for up to 1000 bar to 2 nNm)
2014
Our mission is never complete.
Glovebox-ready: MCR 702e Space MultiDrive is the only rheometer that
- Humidity option (AT Pat. 531661, 2012) We're always pushing the can be operated in a glovebox with inert gas (nitrogen, argon)
2015 boundaries. For more than
- Powder Flow Cell (US Pat. 10031057, 2015) Stable results even for long-term measurements with low torque:
25 years we have continuously Improved thermal management within the EC motor with MCR 302e
2016 extended our portfolio in close
- The entry-level rheometers by Anton Paar,
MCR 72 and MCR 92, a completely new collaboration with our most More space for sample handling and exchange of accessories:
device category Extended working height of MCR 302e
important innovation driver, YOU,
- TruRay (EP Pat. 3220127, 2016), SafeGap
(US Pat. 10180381, 2016), and air-cooled our highly valued customers Highly reproducible results: The only device on the market with
Peltier hood a trimming mirror
and rheometer users. We are
2018
- MCR 702 MultiDrive DMA, a rheometer that
now proud to present the new Detection of any sample behavior change even at the shortest time scales:
is a dynamic mechanical analyzer at the same MCR Evolution series: rheometers Reproducible duration of each measuring point down to 1 ms
time (US Pat. 9574983, 2015)
which lead you to results that take
Full pharma compliance: You get the best pharma package for
2019
you and your scientific work one the RheoCompass software (21 CFR Part 11, full data integrity
- Powder Shear Cell
step ahead. according to ALCOA+)
7
Choose from ...rheometer portfolio
the broadest... on the market
- Torque range from 2 nNm to 200 mNm - Torque range from 0.5 nNm to 230 mNm
- Normal force measurements up to 50 N - Upgradeable with a second EC drive or linear drive
- Sample-adaptive controllers (TruStrainTM, TruRateTM) - Maximum speed of 6000 rpm for high-shear applications
available as an option - Working modes: CMT, SMT, counter-movement
MCR 302e OP-S
E
LLER MCR 702e Space MultiDrive
T
T H E E S TA B L I S H E D U N I V E R S A L A N D D E S I G N E D T O P R O V I D E A U N I Q U E M A X I M I Z E D W O R K S PA C E
OP-S
M O S T- S O L D R H E O M E T E R . R E F E R E N C E O N T H E M A R K E T B E L O W T H E R H E O M E T E R S U P P O R T P L AT E A N D O N
T
F O R A D VA N C E D Q C T E S T I N G A N D R H E O L O G I C A L LLER
E B O T H S I D E S O F T H E I N S T R U M E N T.
RESEARCH. FITS ALL YOUR CURRENT AND
FUTURE NEEDS.
- Torque range from 0.5 nNm to 230 mNm - Torque range from 0.5 nNm to 230 mNm
- Active thermal management of motor and bearing for long-term - Suitable for combination with additional instruments, e.g. a confocal
measurements even at high torques microscope
- Sample-adaptive controllers (TruStrainTM, TruRateTM) included - Glovebox-ready, even when using inert gas atmosphere (nitrogen, argon)
- More space for sample handling and exchange of accessories, full
compatibility with CTD 1000
- Maximum torque of 300 mNm - MCR 72 and MCR 92 for quick and easy rheological measurements
- Maximum normal force of 70 N - The SmartPave rheometer is designed for the asphalt industry
- Active thermal management of motor and bearing for long-term - The “furnace rheometer” FRS handles sample temperatures up to 1730 °C
measurements even at high torques - The automated rheometer HTR is operated by a robotic arm
- The rheometer head DSR can be integrated into your process or used to
build a customized rheometer system
8 9
MCR Evolution Series
Highly evolved features
TA K E S W O R K O F F Y O U R H A N D S : EXCELLENCE IN EVERY COMPONENT AND EVERY WORK STEP
UNIQUE MOTOR AND SAMPLE-
ADAPTIVE CONTROLLER
TECHNOLOGY
The MCR Evolution series builds on After decades in the field, Anton Paar understands what is required for
25 years of research, development, outstanding rheological analysis. With this knowledge in mind, we designed
and constant improvement. This every component and created every handling step to be part of a smooth
results in technology which pushes and intelligent whole:
the boundaries of rheometry. The
combination of the EC motor with The patented Toolmaster™ technology automatically recognizes
the high-precision air bearing, measuring systems and accessories, transfers all relevant parameters
integrated normal force sensor, and to the software without the risk of errors, and stores the zero-gap
a high-resolution optical encoder, position to save time when loading the next sample.
for example, allows rheological
measurements at the lowest torques Due to the QuickConnect coupling, measuring systems can be
ever. exchanged with one hand and within a second.
10 11
MCR 702e MultiDrive and MCR 702e MultiDrive and MCR 702e Space MultiDrive give you access to two
drive units in a single instrument. Both cover all test modes, measuring systems,
MCR 702e Space MultiDrive accessories, and temperature devices without any limitation on measurement
The features beyond precision.
Including all features known from the MCR series these devices allow for the most
sophisticated research with rheology, dynamic mechanical analysis, and other
characterization methods.
MEASURING
DRIVING
12 13
RheoCompass
software
T H E M O S T- C O M P R E H E N S I V E R H E O M E T E R S O F T W A R E O N T H E M A R K E T
Whatever you want to investigate with your rheometer, the Meets all challenges – from routine QC testing up to scientific analysis
RheoCompass software provides appropriate templates to use
More than 100 predefined and customizable measurement templates (apps)
or adapt and helps you analyze the results.
This powerful software can fully automate the entire process Available in 8 languages
from sample preparation to printout of results (using the Test-, (English, German, Chinese, Japanese, French, Portuguese, Spanish, Polish)
Read more Complete pharma package including audit trail, electronic signature, and retrieval
www.anton-paar.com/
apb-rheocompass
14 15
Measuring
geometries
Tribology systems
Parallel plate (PP)
Double gap (DG)
Powder systems
Cone-plate (CP)
Your MCR rheometer has a setup to suit all your applications, from
DMA fixtures
investigations on liquids, solids, powders, and polymers, to adhesives and
Stirrers
slurries. Choose from hundreds of measuring geometries and combine them
with a wide range of temperature devices and application-specific accessories
to get outstanding analysis results. Low-viscosity liquids
Viscoelastic liquids
Melts
Read more
Paste-like materials
Gel-like materials
Soft solids
Reactive systems
www.anton-paar.com/
apb-geometries
Powder
Solids
More grip: Diverse surface treatments Made for you: Customized solutions
Geometries with sandblasted or profiled surfaces Take advantage of our highly specialized production
will prevent wall slip and guarantee the grip that is engineering "Made in Austria": we are happy to
necessary for precise material characterization. adapt each type of measuring geometry to fit your
specific needs.
16 17
Temperature devices WITH THESE ACCESSORIES YOU ARE ABLE TO CONTROL THE GREATEST RHEOLOGICAL INFLUENCE OF ALL:
TEMPERATURE. CHOOSE FROM A VAST RANGE OF MORE THAN 40 TEMPERATURE DEVICES AND RELY ON THE
HIGH-PRECISION TEMPERATURE CONTROL REQUIRED FOR TRULY ACCURATE RHEOLOGICAL RESULTS.
ADDITIONAL ACCESSORIES
L I Q U I D T E M P E R AT U R E C O N T R O L P E LT I E R T E M P E R A T U R E C O N T R O L E L E C T R I C A L T E M P E R AT U R E C O N T R O L C O N V E C T I O N T E M P E R AT U R E C O N T R O L
F A S T T E M P E R AT U R E D E V I C E B A S E D O N
C O S T- E F F E C T I V E T E M P E R A T U R E C O N T R O L C O M P A C T A N D E A S I LY I N S T A L L A B L E
E L E C T R I C A L H E AT I N G A N D C O O L I N G O F T H E M O S T F L E X I B L E T E M P E R AT U R E D E V I C E
S O L U T I O N S B A S E D O N H E AT I N G A N D C O O L I N G T E M P E R AT U R E D E V I C E S B A S E D O N H E AT I N G
P R E S S U R I Z E D A I R O R W AT E R F O R P R O P E R BASED ON FORCED CONVECTION OF AIR OR
W I T H C I R C U L AT I N G L I Q U I D ; C O V E R S T H E R A N G E A N D C O O L I N G U S I N G P E LT I E R E L E M E N T S
T E M P E R AT U R E C O N T R O L E V E N AT H I G H G A S A N D R A D I AT I O N .
A R O U N D R O O M T E M P E R AT U R E . UP TO 200 °C.
T E M P E R AT U R E S .
- Temperature range from -40 °C to 180 °C - Temperature range from -40 °C to 200 °C - Temperature range from -160 °C to 1000 °C
- Temperature devices for parallel-plate, cone-plate, concentric- - Devices for all measuring systems available - Temperature range from -150 °C to 400 °C - Modular configuration suitable for all measuring systems
cylinder, double-gap measuring geometries, and stirrers - Active cooling without the need of additional low - Temperature devices for parallel-plate, cone-plate, concentric- - Lowest gas flow rates to avoid air vortexes or drying samples
- XL version available for the measurement of liquids with very temperature options cylinder, double-gap measuring geometries, and stirrers - Unique Peltier-temperature-controlled oven available
low viscosities - Air-cooled Peltier systems available (no fluid circulator needed) - Additional heated hoods for minimized temperature gradients (CTD 180 HR)
Read more: www.anton-paar.com/apb-tc-fluid Read more: www.anton-paar.com/apb-tc-peltier Read more: www.anton-paar.com/apb-tc-electrical Read more: www.anton-paar.com/apb-tc-convection
18 19
Accessories for THE COMBINATION OF RHEOMETRY AND STRUCTURE ANALYSIS PROVIDES YOU WITH THE MACROSCOPIC
“BIG PICTURE” AS WELL AS INFORMATION ON THE SMALLEST MICROSTRUCTURE CHANGES ALL AT ONCE –
TAKING YOU A BIG STEP TOWARDS COMPLETELY UNDERSTANDING THE BEHAVIOR OF YOUR SAMPLE.
structure analysis and RheoOptics
RAMAN- AND IR
SPECTROSCOPY
20 21
Accessories for THE ACCESSORIES FOR “ADDITIONAL PARAMETER SETTING” ENABLE YOU TO PERFORM TEMPERATURE-
CONTROLLED RHEOLOGICAL TESTS WHILE APPLYING AN ADDITIONAL WELL-DEFINED EXTERNAL INFLUENCING
FACTOR. BUILD ON YOUR RHEOMETER TO INVESTIGATE HOW ADDITIONAL PARAMETERS SUCH AS PRESSURE
additional parameter setting OR AN ELECTRIC FIELD CHANGE THE FLOW AND DEFORMATION BEHAVIOR OF YOUR SAMPLE.
due to the influence on intermolecular forces HUMIDITY OPTION FOR - Magneto-rheological (MR)
- Pressure cells can be used to simulate process conditions, measure CTD 180 HR
ELECTRO-RHEOLOGICAL fluids react almost instantly to
the sample’s pressure dependence, and prevent sample evaporation UV CURING SYSTEM - The relative humidity can DEVICE (ERD) an applied magnetic field with
above the boiling point - When UV curing materials influence the moisture content - Electro-rheological (ER) fluids a change in their rheological
- Typical applications: polymers, petrochemicals, oil recovery, and food are exposed to UV light, a of various materials and are suspensions of electrically properties
processing chemical cross-linking reaction affect their rheological and active particles dispersed in an - Typical applications: clutches,
occurs and causes changes mechanical properties electrically insulating fluid sealings, brakes, shock
in the rheological properties, - Study the impact on drying or - ER fluids change their absorbers, seismic dampers,
typically within seconds or a plasticizing but also on curing rheological properties human prostheses
few minutes reactions dramatically when an electric - Flux density: max. 1.4 Tesla
PRESSURE CELLS PRESSURE CELLS
UP TO 400 BAR UP TO 1000 BAR
- Typical applications: epoxy - Typical applications: polymers, field is applied - From -10 °C to 170 °C (lower
resins, adhesives, glues, adhesives, sealants, - Typical applications: clutches, temperatures on request)
- From -30 °C to 300 °C - From ambient to 300 °C printing inks, coatings coatings and paints, food, brakes, pumps, dampers, - Patented TwinGap™ geometry
- Gas- and self-pressurization - Low temperature option pharmaceuticals shock absorbers, printing inks, (US Pat. 8132445) enables
are used to control the available on request - From -40 °C to 300 °C haptic devices the highest homogeneous
pressure - Gas-, liquid-, or - Different mercury and LED - Humidity range from 5 % to magnetic fields and high shear
- Low- and high-volume cells self-pressurization can be light sources as well as filters 95 % RH - Voltage range: 0 kV to rate measurements
available used to control the pressure for the emission of discrete - From 5 °C to 120 °C 12.5 kV DC (AC on request) Read more:
www.anton-paar.com/apb-mrd
- Low-friction ball bearings - Low-friction and highly wavelengths are available - Can be used with standard - From -50 °C to 300 °C
for precise rheological resistant jewel bearings enable - Usable with Peltier, electrical, and specialized measuring - For parallel-plate and I M M O B I L I Z AT I O N C E L L ( I M C )
measurements characterization even of and convection temperature systems for rheology and concentric-cylinder geometries
- Choose between versions in rod-climbing viscoelastic fluids devices (part of the DMA in torsion, tension, - Suitable for rotational and - Investigate the immobilization
stainless steel, titanium, or - Internal construction of RheoOptics toolbox) bending, and compression oscillatory tests as well as kinetics and water retention
Hastelloy if you investigate titanium or Hastelloy for - Combinable with Raman or - Combinable with UV light, squeeze flow of paints, coatings, and
aggressive media improved resistance to IR spectroscopy to determine powder rheology, and - Customized solutions for slurries by simulating process
- Flow-through option available aggressive materials changes on the molecular tribology combination with polarized conditions
- Flow-through options available level simultaneously - AT Pat. 513661 imaging or microscopy - US Pat. 6098450, 1998
Read more: Read more: Read more: Read more: Read more:
www.anton-paar.com/apb-pressure-cell www.anton-paar.com/apb-uvlcs www.anton-paar.com/apb-hmo www.anton-paar.com/apb-erd www.anton-paar.com/apb-imc
22 23
Accessories for THE OPEN RANGE OF POSSIBILITIES WITH AN MCR RHEOMETER DOES NOT STOP AT SHEAR RHEOLOGY.
A COMPREHENSIVE SELECTION OF EASILY INTEGRATED ACCESSORIES TRANSFERS THE CAPABILITIES OF
THE INTRINSICALLY MODULAR MCR SERIES INTO OTHER MATERIAL.
extended material characterization
FURTHER ACCESSORIES
Tribology Cells
- Allow the tribological
characterization of a broad
range of applications from
lubricants, biomaterials, and
polymers to food
- For extended Stribeck curves,
static friction, limiting friction
(including break-away torque)
- US Pat. 9702809,
AT Pat. 505938
EXTENSIONAL RHEOLOGY Read more:
www.anton-paar.com/apb-mcr-tribometer
DYNAMIC MECHANICAL - Extensional flow happens L A R G E - PA R T I C L E R H E O L O G Y
A N A LY S I S ( D M A ) in many applications - Measure the flow properties
- DMA is an analytical method and processes, often in I N T E R FA C I A L R H E O L O G Y of samples with large particles Powder rheology
for determining the viscoelastic combination with shear flow SYSTEM (IRS) (typical particle size range of - Perform true powder rheology
properties of materials under - Gain information about - Precise studies of the flow 1 mm to 10 mm) to analyze bulk solids in
sinusoidal load molecular structure, properties of interfacial layers - Typical applications: building any state, from fluidized to
- The temperature of the sample branching, temperature - Study the flow properties of S TA R C H C E L L materials (e.g. cement, consolidated powders
and the frequency of the load stability, shrinkage, relaxations, two-dimensional liquid-liquid - Starch pasting cell for analysis concrete, plaster), food - Powder Shear Cell: ideal for
are often varied to determine and brittleness as well as the and liquid-air interfaces of starch gelatinization or products, slurries, and sludges determining the flow behavior
transitions within the material adhesion and peel strength of - Comprehensive rheological pasting behavior of consolidated powders and
behavior (e.g. glass transition materials investigations of emulsion and - Simulate the temperature and Ball Measuring System (BMS) their time-dependent behavior
temperature) - Typical applications: polymer foam stability pressure conditions of food - From -10 °C to 70 °C - Powder Flow Cell: an
- Typical applications: polymers films and fibers, melts, - Typical applications: emulsion production processes - Measuring principle is an innovative and scientific
and composites, foams, gels, adhesives and foam stability, food - Typical applications: food, eccentrically rotating ball in a approach towards powder
food systems, elastomers products, detergents, life confectionery products, cup which avoids undesired characterization offering a
- The Universal Extensional science paper and packaging, slipping, gliding, and wide range of test methods
- MCR is the world’s most Fixture for a configuration pharmaceuticals, adhesives disturbing edges (US Pat. 10031057)
versatile platform for both with two EC drives (UXF-TD) - From 5 °C to 70 °C Read more:
www.anton-paar.com/apb-powder
dynamic mechanical analysis enables measurements - Bi-cone measuring geometry - Max. heating rate: 60 °C/min; Building Material Cell (BMC)
and rheological investigations, with unprecedented torque or a Du Noüy ring, positioned max. cooling rate: 45 °C/min - From 0 °C to 90 °C Find more details about these devices
allowing you to perform and strain resolution on directly in the interface - Robust and easy-to-clean cup - Changeable, robust, and and accessories in separate brochures.
DMA in all working modes low-viscosity films and fibers - Even the weakest interfacial and stirrer made of stainless easy-to-clean inset cage and
(torsion, tension, bending, (US Pat. 9766172) structures can be measured steel special stirrer
compression) - The Sentmanat Extensional with the MCR low-torque - Unique small sample amounts - Resistant to abrasive
- From -160 °C to 1000 °C Rheometer (SER) system capabilities and the of around 18 mL materials, prevents sample
- Touch-control for fast and is perfectly suitable for TruStrain™ feature - RVA stirrer design available slippage, and provides
easy positioning of the extensional tests at high - Flow-through option available - Optional Starch Pressure Cell improved mix-up effects to
geometries torques on request up to 30 bar and 160 °C avoid separation
Read more: Read more: Read more: Read more: Read more:
www.anton-paar.com/apb-dma-mcr-702 www.anton-paar.com/apb-uxf-ser www.anton-paar.com/apb-irs www.anton-paar.com/apb-sc www.anton-paar.com/apb-bms-bmc
24 25
Special AS WELL AS BEING THE MOST CITED RHEOMETER SERIES, THE MCR IS THE MOST POPULAR RHEOMETER IN
THE WORLD WITH MORE MODELS SOLD THAN ANY OTHER RHEOMETER ON THE MARKET. THE SECRET TO THIS
SUCCESS: LISTENING TO CUSTOMER FEEDBACK AND CREATING OUTSTANDING TECHNOLOGY IN RESPONSE.
instruments AS WELL AS CREATING AND CONSTANTLY IMPROVING OUR “CLASSIC” BENCHTOP RHEOMETERS, OUR TEAM HAS
PRODUCED A NUMBER OF SPECIAL SOLUTIONS.
and customized
solutions
26 27
Academy
and education
Successful work in the field of rheology is not only determined by the technology
We are confident in the high quality
you use, but also by the partner that helps you solve your rheological challenges. of our instruments. That’s why we provide
Anton Paar is here to give you support. full warranty for three years.
at your location
28 29
MCR 702e MultiDrive MCR 702e MultiDrive
MCR 702e Space MultiDrive MCR 702e Space MultiDrive
Configuration with Configuration with Configuration with Configuration with
MCR 102e MCR 302e MCR 502e Power 1 EC motor 2 EC motors MCR 102e MCR 302e MCR 502e Power 1 EC motor 2 EC motors
1)
US Pat. 8453496
2)
2 nNm with activated TruStrainTM option
3)
In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode depending on measuring point duration and sampling rate
4)
Theoretical value (duration per cycle = 2 years)
5)
Higher frequencies are possible using multi-wave functionality (942 rad/s (150 Hz) or even higher, depending on measuring system and sample)
6)
Enlarged working space underneath the support plate (flange)
7)
MCR 702e Space MultiDrive: Unique maximized workspace below the rheometer support plate and on both sides of the instrument
8)
Depending on used temperature device
9)
Customized systems used in CTD 1000
30 31
© 2021 Anton Paar GmbH | All rights reserved.
Specifications subject to change without notice.
C92IP001EN-N
document Number
www.anton-paar.com