You are on page 1of 17

The Modular Compact

Rheometer series
MCR
Product name
Evolution
MCR: Your Rheometers from the market leader

future-proof
rheometer 10,000+ installations worldwide

15 rheometer models

200+ accessories for the perfect


The MCR rheometer series from custom fit
the market leader Anton Paar offers
you one thing first and foremost: an
open range of possibilities. Whatever
Over 25 years of EC motor
technology
your rheological requirements
are and will be in the future –
based on its modular setup, your 97 % of critical parts produced
MCR rheometer is efficiently and in-house in Austria
comfortably adapted and extended
to meet your needs, from routine 30+ subsidiaries provide qualified
quality control to high-end R&D local support
applications. Choose from the
biggest portfolio available on the
market. CONTENTS

04 Benefits of MCR rheometers


An investment in an MCR rheometer
06 What's new: MCR Evolution series
is always a safe investment in
08 MCR portfolio overview
longstanding technology and
10 Features of the MCR Evolution series
endless possibilities.
12 Additional features of MCR 702e MultiDrive and Space

14 RheoCompass software

16 Accessories: Measuring geometries

18 Accessories: Temperature devices

20 Accessories: Structure analysis and RheoOptics


Find out more
22 Accessories: Additional parameter settings

24 Accessories: Extended material characterization

26 Special instruments and customized products

28 Service, support, and education


www.anton-paar.com/
apb-rheometers 30 Technical specifications
2 3
MCR by numbers

MORE THAN 30
SUBSIDIARIES PROVIDE
QUALIFIED SUPPORT ALL
OVER THE WORLD

Anton Paar started as a
one-man machine repair
APPROX. 97 % OF CRITICAL
workshop in Graz (Austria)
OVER 25 YEARS OF EC
MOTOR TECHNOLOGY
PA R T S P R O D U C E D I N - H O U S E back in 1922 and now has
A N D C U S T O M I Z AT I O N O N over 3400 employees and a
MORE THAN 10,000 OFFER
I N S TA L L AT I O N S W O R L D W I D E
worldwide service network of
Your rheological investigations more than 30 subsidiaries and
CHOOSE FROM demand the highest measuring At Anton Paar we take quality numerous responsible partners.
MCR is the most-used 15 RHEOMETER MODELS sensitivity. To achieve this, the very seriously. Our rheometers This means that an expert on
AND MORE THAN
rheometer worldwide. Highly 200 ACCESSORIES
MCR’s EC motor (Permanent are produced at the company’s your system is always close by.
satisfied with their MCR Magnet Synchronous Motor) headquarters in Austria with Anton Paar is the first choice
rheometers, thousands of users with integrated normal force more than 97 % of all critical for answering any rheological
have been with us from the very Anton Paar has the broadest sensor has exceptional mechanical parts manufactured question you may have. We
beginning and have been using portfolio on the market. low-torque capabilities down in-house, ensuring a secure are proud of our reputation for
their MCRs for decades. Around This includes 15 different to 0.0005 µNm, which can supply in case you need parts excellent service and support
the globe our instruments are at rheometers that can be be compared to the load of or accessories at a later date. and look forward to being your
work in R&D and academia as combined with over 200 a single human hair on an As our production facilities reliable partner. Call us for
well as in industrial laboratories different accessories giving you extended arm. Anton Paar was are just next door to the R&D advice on test definitions or to
measuring substances ranging endless possibilities in the field the first company to employ department, in which we invest discuss different approaches to
from paints and coatings, of rheological characterization. an EC motor in a rheometer 20 % of our turnover each solving a measuring problem.
polymers, food, automotive Each accessory extends the over 25 years ago. This motor year, we can also customize Our experts are just a phone
liquids, and petrochemicals to capabilities of the rheometer reached sensitivity values that and develop products for your call away and happy to help,
building materials, adhesives, and can easily be exchanged or were previously unthinkable and specific applications. Talk to us in your local language and free
and many more. added even years later. is still unrivaled today. about your special requirements. of charge.

To find out more about Anton Paar, visit:

www.anton-paar.com/apb-company
4 5
19 The best
95 now
A F I N E S E L E C T I O N O F F I R S T- T I M E
U N I Q U E R H E O M E T E R I N N O VAT I O N S :

1995
better
- EC motor and the modular rheometer concept
with UDS 200
- Controlled stress, shear rate, and strain in
one rheometer
- QuickConnect coupling

1996
- Normal force sensor principle
(US Pat. 6167752, 1996)

1999
- Peltier hood (US Pat. 6571610, 1999)
and cylinder temperature control
(US Pat. 6240770, 1999)
- Direct-strain oscillation (DSO, TruStrain™)
- Automatic sample changer for automated
measurement

2004
- Unique and still unrivaled features: 20
21 MCR
Toolmaster™ (US Pat. 7275419, 2004),
TruGap™ (US Pat. 6499336, 2000)
- CTD 1000 for measurements up to 1000 °C
- Setups for tribology Evolution –
- High-throughput rheometer (HTR) Easiest possible coupling and decoupling of measuring systems with one

2011
what is new? hand even at extreme temperatures (-160 °C to 1000 °C): novel quick-
connect mechanism
- T-Ready™ for detection of sample equilibrium
time (US Pat. 8904852, 2011)
Precisely measure even low-viscosity samples with our most compact
2012 rheometer model: Higher sensitivity with MCR 102e (from 7.5 nNm
- Pressure Cell for up to 1000 bar to 2 nNm)

2014
Our mission is never complete.
Glovebox-ready: MCR 702e Space MultiDrive is the only rheometer that
- Humidity option (AT Pat. 531661, 2012) We're always pushing the can be operated in a glovebox with inert gas (nitrogen, argon)
2015 boundaries. For more than
- Powder Flow Cell (US Pat. 10031057, 2015) Stable results even for long-term measurements with low torque:
25 years we have continuously Improved thermal management within the EC motor with MCR 302e
2016 extended our portfolio in close
- The entry-level rheometers by Anton Paar,
MCR 72 and MCR 92, a completely new collaboration with our most More space for sample handling and exchange of accessories:
device category Extended working height of MCR 302e
important innovation driver, YOU,
- TruRay (EP Pat. 3220127, 2016), SafeGap
(US  Pat. 10180381, 2016), and air-cooled our highly valued customers Highly reproducible results: The only device on the market with
Peltier hood a trimming mirror
and rheometer users. We are
2018
- MCR 702 MultiDrive DMA, a rheometer that
now proud to present the new Detection of any sample behavior change even at the shortest time scales:
is a dynamic mechanical analyzer at the same MCR Evolution series: rheometers Reproducible duration of each measuring point down to 1 ms
time (US Pat. 9574983, 2015)
which lead you to results that take
Full pharma compliance: You get the best pharma package for
2019
you and your scientific work one the RheoCompass software (21 CFR Part 11, full data integrity
- Powder Shear Cell
step ahead. according to ALCOA+)

7
Choose from ...rheometer portfolio
the broadest... on the market

MCR 102e MCR 702e MultiDrive


T H E M O S T C O M PA C T E V O L U T I O N R H E O M E T E R M O D E L : THE HIGH-END RHEOMETER AND SCIENTIFIC REFERENCE
YOUR ENTRY TICKET INTO THE WORLD OF QC TESTING AND F O R S O P H I S T I C AT E D R H E O L O G I C A L R E S E A R C H
R H E O L O G I C A L P R O D U C T D E V E L O P M E N T. U P G R A D E A B L E T O AND DMA: ONE RHEOMETER, TWO DRIVE UNITS,
FIT ALL YOUR FUTURE REQUIREMENTS. ALL WORKING MODES.

- Torque range from 2 nNm to 200 mNm - Torque range from 0.5 nNm to 230 mNm
- Normal force measurements up to 50 N - Upgradeable with a second EC drive or linear drive
- Sample-adaptive controllers (TruStrainTM, TruRateTM) - Maximum speed of 6000 rpm for high-shear applications
available as an option - Working modes: CMT, SMT, counter-movement

MCR 302e OP-S
E
LLER  MCR 702e Space MultiDrive

 T
T H E E S TA B L I S H E D U N I V E R S A L A N D D E S I G N E D T O P R O V I D E A U N I Q U E M A X I M I Z E D W O R K S PA C E

OP-S
M O S T- S O L D R H E O M E T E R . R E F E R E N C E O N T H E M A R K E T B E L O W T H E R H E O M E T E R S U P P O R T P L AT E A N D O N
 T

F O R A D VA N C E D Q C T E S T I N G A N D R H E O L O G I C A L LLER 
E B O T H S I D E S O F T H E I N S T R U M E N T.
RESEARCH. FITS ALL YOUR CURRENT AND
FUTURE NEEDS.

- Torque range from 0.5 nNm to 230 mNm - Torque range from 0.5 nNm to 230 mNm
- Active thermal management of motor and bearing for long-term - Suitable for combination with additional instruments, e.g. a confocal
measurements even at high torques microscope
- Sample-adaptive controllers (TruStrainTM, TruRateTM) included - Glovebox-ready, even when using inert gas atmosphere (nitrogen, argon)
- More space for sample handling and exchange of accessories, full
compatibility with CTD 1000

FRS FURNACE RHEOMETER

MCR 502e Power Additional MCR devices


THE MOST POWERFUL RHEOMETER MODEL WITH THE WORLD OF RHEOLOGY IS EXTENSIVE AND OFTEN
U N I Q U E S P E C I F I C AT I O N S F O R S P E C I A L A P P L I C AT I O N S , REQUIRES SPECIAL INSTRUMENT SOLUTIONS FOR
E . G . F A T I G U E T E S T S O N A S P H A LT M I X T U R E S . C H A L L E N G I N G M E A S U R E M E N T TA S K S .

- Maximum torque of 300 mNm - MCR 72 and MCR 92 for quick and easy rheological measurements
- Maximum normal force of 70 N - The SmartPave rheometer is designed for the asphalt industry
- Active thermal management of motor and bearing for long-term - The “furnace rheometer” FRS handles sample temperatures up to 1730 °C
measurements even at high torques - The automated rheometer HTR is operated by a robotic arm
- The rheometer head DSR can be integrated into your process or used to
build a customized rheometer system

8 9
MCR Evolution Series
Highly evolved features
TA K E S W O R K O F F Y O U R H A N D S : EXCELLENCE IN EVERY COMPONENT AND EVERY WORK STEP
UNIQUE MOTOR AND SAMPLE-
ADAPTIVE CONTROLLER
TECHNOLOGY

The MCR Evolution series builds on After decades in the field, Anton Paar understands what is required for
25 years of research, development, outstanding rheological analysis. With this knowledge in mind, we designed
and constant improvement. This every component and created every handling step to be part of a smooth
results in technology which pushes and intelligent whole:
the boundaries of rheometry. The
combination of the EC motor with The patented Toolmaster™ technology automatically recognizes
the high-precision air bearing, measuring systems and accessories, transfers all relevant parameters
integrated normal force sensor, and to the software without the risk of errors, and stores the zero-gap
a high-resolution optical encoder, position to save time when loading the next sample.
for example, allows rheological
measurements at the lowest torques Due to the QuickConnect coupling, measuring systems can be
ever. exchanged with one hand and within a second.

The unique sample-adaptive


controllers for measurement in T-Ready™ increases your sample throughput and avoids measuring
rotation (TruRate™) and oscillation errors by detecting sample temperature equilibration in real-time.
(TruStrain™) work for 99 % of all
samples and measurements “out of The TruGap™ feature detects the real measuring gap and ensures
the box” with the perfect combination accurate gap settings in real-time, even when the room- and sample
of speed and accuracy – save time temperatures change.
and nerves and get even better data
at the same time! The trimming mirror gives you a 360° view of the sample with no
blind spots, avoids sample preparation errors, and thus supports high
measurement repeatability.
CUSTOMIZE YOUR MCR WITH
OVER 200 ACCESSORIES The steel frame is optimized for mechanical and thermal stiffness and
Whatever your rheological minimizes torsional and axial compliance which allows measurement
of even the stiffest samples like ceramics and metal.
applications are and will be in the
future – Anton Paar rheometers are
quickly and easily adapted to meet The lift motor in the stand provides precise gap setting and
your needs. Their flexibility makes automatically compensates gap changes related to temperature and
them the most cited instruments in normal force.
scientific publications on rheological
investigations. A wide range of The device display provides remote control of the software to
temperature accessories allows you minimize sample preparation time.
to apply and control temperatures
from -160 °C to 1000 °C. An
extensive range of application-specific The open design enables easy and fast sample loading and trimming.
accessories is available to extend the
rheometer’s capabilities.

10 11
MCR 702e MultiDrive and MCR 702e MultiDrive and MCR 702e Space MultiDrive give you access to two
drive units in a single instrument. Both cover all test modes, measuring systems,
MCR 702e Space MultiDrive accessories, and temperature devices without any limitation on measurement
The features beyond precision.

Including all features known from the MCR series these devices allow for the most
sophisticated research with rheology, dynamic mechanical analysis, and other
characterization methods.

MEASURING

DRIVING

ONE RHEOMETER, ALL


RHEOLOGICAL WORKING
MODES

MCR 702e MultiDrive enables


you to work with one EC motor
in Combined Motor Transducer
(CMT) mode or two EC motors
in Separate Motor Transducer
(SMT) mode.
THE DEVICE FOR
A P P L I C AT I O N S T H AT W E R E
In SMT mode one motor is P R E V I O U S LY U N T H I N K A B L E
operated solely as a torque
transducer, while the other
PUSH BACK THE READY FOR DYNAMIC
motor is used as a drive unit L I M I T S O F M AT E R I A L The maximized workspace
M E C H A N I C A L A N A LY S I S
only. This delivers the purest C H A R A C T E R I Z AT I O N W I T H of MCR 702e Space
THE COUNTER-MOVEMENT
rheological results even in MODE
MultiDrive allows easy
the transient regime of the Due to the modular concept installation of accessories
measurement (e.g. stress of the MCR an additional and easy combination with
relaxation, start-up shear) and In counter-movement mode the lower linear drive can easily additional external setups
over a broad range of amplitude two EC motors can rotate or be inserted to perform DMA (e.g. a confocal microscope)
and frequency in oscillatory oscillate in opposite directions. in tension, bending, or suitable for advanced material
measurements. This creates a fixed stagnation compression mode, creep characterization. In addition,
plane which can be used for and creep recovery tests, the rheometer's separate
Using CMT mode, you can advanced optical analysis of relaxation tests, and even electronics box allows you
use the motor’s real-time structures within a sheared thermomechanical analysis. to set up the rheometer
position control (TruStrain™) sample using a microscope. where space is limited or in
or perform ‘classic’ stress- This mode simply doubles the In combination with the a laboratory glovebox, even
controlled tests in combination maximum achievable rotational capability of the upper rotational when using inert gas (nitrogen,
with the extensive range of speed of the rheometer up drive for DMA in torsion, the argon) atmosphere, e.g. for
accessories. With this setup you to 6000 rpm, which helps to setup enables a complete high-temperature measurements
can cover the broadest range of broaden the shear rate range for characterization of viscoelastic on samples with a certain
rheological applications. high-shear applications. solids. hazard level.

12 13
RheoCompass
software
T H E M O S T- C O M P R E H E N S I V E R H E O M E T E R S O F T W A R E O N T H E M A R K E T

Whatever you want to investigate with your rheometer, the Meets all challenges – from routine QC testing up to scientific analysis
RheoCompass software provides appropriate templates to use
More than 100 predefined and customizable measurement templates (apps)
or adapt and helps you analyze the results.
This powerful software can fully automate the entire process Available in 8 languages
from sample preparation to printout of results (using the Test-, (English, German, Chinese, Japanese, French, Portuguese, Spanish, Polish)

Analysis-, and Report Designers). The software can even be


Central database handles all relevant data, guarantees data security, and enables
remote-controlled from the rheometer display to minimize the time server/client functionality
you spend on sample preparation.
Countless analysis methods available for routine and advanced data analysis

Automatic data exchange with a lab information management system (LIMS)

Read more Complete pharma package including audit trail, electronic signature, and retrieval

Fully complies with QM regulations like GLP/GMP, 21 CFR Part 11,


and ALCOA+ with full data integrity.
Read more: https://www.anton-paar.com/apb-pharma

www.anton-paar.com/
apb-rheocompass

14 15
Measuring
geometries

Concentric cylinder (CC)

Tribology systems
Parallel plate (PP)
Double gap (DG)

Powder systems
Cone-plate (CP)
Your MCR rheometer has a setup to suit all your applications, from

DMA fixtures
investigations on liquids, solids, powders, and polymers, to adhesives and

Stirrers
slurries. Choose from hundreds of measuring geometries and combine them
with a wide range of temperature devices and application-specific accessories
to get outstanding analysis results. Low-viscosity liquids

Viscoelastic liquids

Melts

Read more
Paste-like materials

Gel-like materials

Soft solids

Reactive systems
www.anton-paar.com/
apb-geometries
Powder

Solids

YOU CAN RELY ON THESE EVOLUTIONARY FEATURES

Error-free: Toolmaster™ technology Disposable and resistant: Special geometries


Toolmaster (US Pat. 7275419) automatically If the substances you investigate make it difficult
recognizes measuring geometries and accessories, to reuse or clean the measuring geometry (e.g.
transfers all relevant parameters to the software because of an irreversible hardening process)
without the risk of errors, and stores the zero-gap use our disposable geometries. We also have
position to save time when loading the next geometries resistant to harsh chemicals and
sample. temperatures up to 1800 °C.

Convenient: QuickConnect coupling Sensitive: Integrated temperature sensor


Measuring geometries can be exchanged with Integrated temperature sensors enable the
one hand and within a second. The reduced time determination of even the smallest deviations in
and effort required for changing, cleaning, and sample temperature without affecting the torque
reinstalling the geometry help you work even more sensitivity of the rheometer.
efficiently in the laboratory.

More grip: Diverse surface treatments Made for you: Customized solutions
Geometries with sandblasted or profiled surfaces Take advantage of our highly specialized production
will prevent wall slip and guarantee the grip that is engineering "Made in Austria": we are happy to
necessary for precise material characterization. adapt each type of measuring geometry to fit your
specific needs.

16 17
Temperature devices WITH THESE ACCESSORIES YOU ARE ABLE TO CONTROL THE GREATEST RHEOLOGICAL INFLUENCE OF ALL:
TEMPERATURE. CHOOSE FROM A VAST RANGE OF MORE THAN 40 TEMPERATURE DEVICES AND RELY ON THE
HIGH-PRECISION TEMPERATURE CONTROL REQUIRED FOR TRULY ACCURATE RHEOLOGICAL RESULTS.

ADDITIONAL ACCESSORIES

Low temperature options


- Evaporation Unit for cooling
P-PTD 200 WITH H-PTD 200 with liquid nitrogen down to
Peltier-temperature-controlled C-PTD 200 AND CTD 600 MDR PTD 180 MD -160 °C
device (PTD) with active heating C-PTD 180/AIR Convection temperature device Peltier-temperature-controlled - Customized Gas Chiller
and cooling Peltier-temperature-controlled (CTD oven) device (PTD) for MultiDrive options for cooling down to
- From -40 °C to 200 °C device (PTD) with active heating - From -160 °C to 600 °C configurations -90 °C without liquid nitrogen
- Suitable for parallel-plate and cooling - Suitable for all kinds of - From -20 °C to 180 °C
and cone-plate measuring - From -30 °C to 200 °C P-ETD 400 WITH H-PTD 400 measuring geometries - Suitable for parallel-plate, Solvent traps and covers
geometries - Suitable for concentric Electrically heated temperature - Typical applications: polymer cone-plate, concentric - Minimize solvent evaporation
- Typical applications: food, cylinders, double-gap device (ETD) melts and solids, epoxy resins, cylinders, and double-gap - Reproducible measurements
paints, cosmetics, adhesives, geometries, and stirrers - From -150 °C to 400 °C reinforced materials, films and measuring geometries of volatile samples
bitumen - Typical applications: liquids, - Suitable for parallel-plate fibers - Typical applications: food, - Purge gas options
solvents, solutions, bitumen and cone-plate measuring paints, pharmaceuticals,
- Active temperature-controlled geometries - Chamber made by innovative cosmetics Disposable options
hood guarantees lowest - Minimized vertical sample - Typical applications: polymer 3D metal printing to ensure - Suitable when cleaning is
sample temperature gradients temperature gradients due melts, epoxy resigns accurate and homogeneous - Thermally coupled hood for difficult
down to 0.1 °C to optimized thermal transfer sample temperature reduced temperature gradients - Available for upper and lower
- Gas flushing (air or inert gas) system - Active temperature-controlled - Low (inert) gas consumption - No forced gas convection – geometries
prevents ice formation at low - C-PTD 180/Air with counter- hood minimizes sample for reduced operating costs optimized for low-viscosity
temperatures and sample cooling by air to avoid the use temperature gradients and precise measurements and viscoelastic fluids Immersion options
degradation of an additional fluid circulator - Gas flushing (air or inert gas) even at low torques - Determination of the true - For characterization of
- Exchangeable lower plates for (0 °C to 180 °C) prevents ice formation at low - Integrated LED sample sample temperature with sample properties which are
flexible adaption to your needs - Changing the measuring cup temperatures and sample illumination and digital eye optoelectronic sensor strongly influenced by fluid
takes only a few seconds degradation camera option technology environments

L I Q U I D T E M P E R AT U R E C O N T R O L P E LT I E R T E M P E R A T U R E C O N T R O L E L E C T R I C A L T E M P E R AT U R E C O N T R O L C O N V E C T I O N T E M P E R AT U R E C O N T R O L

F A S T T E M P E R AT U R E D E V I C E B A S E D O N
C O S T- E F F E C T I V E T E M P E R A T U R E C O N T R O L C O M P A C T A N D E A S I LY I N S T A L L A B L E
E L E C T R I C A L H E AT I N G A N D C O O L I N G O F T H E M O S T F L E X I B L E T E M P E R AT U R E D E V I C E
S O L U T I O N S B A S E D O N H E AT I N G A N D C O O L I N G T E M P E R AT U R E D E V I C E S B A S E D O N H E AT I N G
P R E S S U R I Z E D A I R O R W AT E R F O R P R O P E R BASED ON FORCED CONVECTION OF AIR OR
W I T H C I R C U L AT I N G L I Q U I D ; C O V E R S T H E R A N G E A N D C O O L I N G U S I N G P E LT I E R E L E M E N T S
T E M P E R AT U R E C O N T R O L E V E N AT H I G H G A S A N D R A D I AT I O N .
A R O U N D R O O M T E M P E R AT U R E . UP TO 200 °C.
T E M P E R AT U R E S .

- Temperature range from -40 °C to 180 °C - Temperature range from -40 °C to 200 °C - Temperature range from -160 °C to 1000 °C
- Temperature devices for parallel-plate, cone-plate, concentric- - Devices for all measuring systems available - Temperature range from -150 °C to 400 °C - Modular configuration suitable for all measuring systems
cylinder, double-gap measuring geometries, and stirrers - Active cooling without the need of additional low - Temperature devices for parallel-plate, cone-plate, concentric- - Lowest gas flow rates to avoid air vortexes or drying samples
- XL version available for the measurement of liquids with very temperature options cylinder, double-gap measuring geometries, and stirrers - Unique Peltier-temperature-controlled oven available
low viscosities - Air-cooled Peltier systems available (no fluid circulator needed) - Additional heated hoods for minimized temperature gradients (CTD 180 HR)
Read more: www.anton-paar.com/apb-tc-fluid Read more: www.anton-paar.com/apb-tc-peltier Read more: www.anton-paar.com/apb-tc-electrical Read more: www.anton-paar.com/apb-tc-convection
18 19
Accessories for THE COMBINATION OF RHEOMETRY AND STRUCTURE ANALYSIS PROVIDES YOU WITH THE MACROSCOPIC
“BIG PICTURE” AS WELL AS INFORMATION ON THE SMALLEST MICROSTRUCTURE CHANGES ALL AT ONCE –
TAKING YOU A BIG STEP TOWARDS COMPLETELY UNDERSTANDING THE BEHAVIOR OF YOUR SAMPLE.
structure analysis and RheoOptics

RAMAN- AND IR
SPECTROSCOPY

- Combines two powerful


measurement principles:
rheology as a mechanical
and Raman or infrared as FURTHER ACCESSORIES

a molecular spectroscopy Polarized Light Imaging Option


method - For visualization of shear
- Understand the relationship stress
between macromolecular and - For parallel-plate and
structural parameters cone-plate measuring systems
S TA G N AT I O N P L A N E - Can additionally be combined Read more:
www.anton-paar.com/apb-rheooptics-pi
RHEOOPTICS TOOLBOX MICROSCOPY with UV radiation
- Allows you to use the same RHEO-MICROSCOPY - Visualize structures of interest
universal temperature devices - Delivers insights into the inner at the stagnation plane Rheometer-Raman Setup Particle Imaging Velocimetry
for rheo-microscopy, confocal structure of the sample during - Shifts the limits of - Can be combined with an DIELECTRIC-RHEOLOGICAL (PIV)
microscopy, Raman- and rheological measurements rheo-microscopy to larger Anton Paar Cora spectrometer DEVICE (DRD) - Visualization of complex flow
IR spectroscopy, UV curing, - Allows the visualization of shear rates and deformations and others - Combines rheology as a fields such as shear banding,
Polarized Light Imaging, SALS, the influence of shear and as structures do not move out - From -20 °C to 300 °C mechanical spectroscopy turbulence, or flow instabilities
and customized systems deformation forces on the of the field of view - Typical applications: method and dielectric Read more:
www.anton-paar.com/apb-piv
- Modular and cost-saving sample structure - Typical applications: crystallization, chemical spectroscopy
upgrade of the measurement - Typical applications: observation of shear-induced reactions, morphology of - The interpretation of the
possibilities depending on your crystallization processes, deformation and orientation polymers, biological samples obtained dielectric spectrum Small-angle Light Scattering
present and future needs food products, cosmetics, of individual structures or Read more: provides information on the (SALS)
www.anton-paar.com/apb-cora-5001
- Switching to other optical observation of low-shear droplets in polymer solutions, internal structure - For investigating shear-
accessories only requires a orientation effects emulsions, and dispersions - Typical applications: filled dependent shape and
minimal setup time Rheometer-IR Setup polymers (e.g. an epoxy resin orientation of microstructure
- Modules for polarizers and - Measuring systems made - Use near-IR (NIR) and mid-IR filled with carbon nanotubes) Read more:
www.anton-paar.com/apb-sals
- From -20 °C to 300 °C (higher fluorescence of glass enable observation (MIR) in transmission mode and polar materials (like PVA,
temperatures available on - From -20 °C to 300 °C as from below and from the and MIR spectroscopy also PVC, PMMA)
request) standard (higher temperatures side to visualize alignment of in attenuated total reflection Small-angle X-ray/Neutron
- Both temperature devices are available on request) structures in shear gradient (ATR) mode - From -160 °C to 600 °C Scattering (SAXS/WAXS/SANS)
with glass bottom plates - Direct assignment of images and shear flow direction - Many IR spectrometers and - Contact options for rotational - For nanostructure analysis
- Combination with an active and videos to rheological data - A speed balance allows you to probes can be connected and oscillatory tests are - Modular, radiolucent CTD
temperature-controlled - Combination with confocal change the speed distribution - From -20 °C to 300 °C available oven from -50 °C to 300 °C
hood for minimized sample microscopy possible based on without changing the shear - Typical applications: - Various LCR meters can be - Ready for shear and
temperature gradients customized solutions rate applied to the sample monitoring of chemical combined extensional rheology and DMA
Read more about this in the respective Read more: Read more: reactions Read more: Read more:
sections on this page www.anton-paar.com/apb-rheooptics-rm www.anton-paar.com/apb-microscopy www.anton-paar.com/apb-drd www.anton-paar.com/apb-sans-saxs

20 21
Accessories for THE ACCESSORIES FOR “ADDITIONAL PARAMETER SETTING” ENABLE YOU TO PERFORM TEMPERATURE-
CONTROLLED RHEOLOGICAL TESTS WHILE APPLYING AN ADDITIONAL WELL-DEFINED EXTERNAL INFLUENCING
FACTOR. BUILD ON YOUR RHEOMETER TO INVESTIGATE HOW ADDITIONAL PARAMETERS SUCH AS PRESSURE
additional parameter setting OR AN ELECTRIC FIELD CHANGE THE FLOW AND DEFORMATION BEHAVIOR OF YOUR SAMPLE.

PRESSURE CELLS MAGNETO-RHEOLOGICAL


- Pressure can significantly influence a material’s rheological behavior DEVICE (MRD)

due to the influence on intermolecular forces HUMIDITY OPTION FOR - Magneto-rheological (MR)
- Pressure cells can be used to simulate process conditions, measure CTD 180 HR
ELECTRO-RHEOLOGICAL fluids react almost instantly to
the sample’s pressure dependence, and prevent sample evaporation UV CURING SYSTEM - The relative humidity can DEVICE (ERD) an applied magnetic field with
above the boiling point - When UV curing materials influence the moisture content - Electro-rheological (ER) fluids a change in their rheological
- Typical applications: polymers, petrochemicals, oil recovery, and food are exposed to UV light, a of various materials and are suspensions of electrically properties
processing chemical cross-linking reaction affect their rheological and active particles dispersed in an - Typical applications: clutches,
occurs and causes changes mechanical properties electrically insulating fluid sealings, brakes, shock
in the rheological properties, - Study the impact on drying or - ER fluids change their absorbers, seismic dampers,
typically within seconds or a plasticizing but also on curing rheological properties human prostheses
few minutes reactions dramatically when an electric - Flux density: max. 1.4 Tesla
PRESSURE CELLS PRESSURE CELLS
UP TO 400 BAR UP TO 1000 BAR
- Typical applications: epoxy - Typical applications: polymers, field is applied - From -10 °C to 170 °C (lower
resins, adhesives, glues, adhesives, sealants, - Typical applications: clutches, temperatures on request)
- From -30 °C to 300 °C - From ambient to 300 °C printing inks, coatings coatings and paints, food, brakes, pumps, dampers, - Patented TwinGap™ geometry
- Gas- and self-pressurization - Low temperature option pharmaceuticals shock absorbers, printing inks, (US Pat. 8132445) enables
are used to control the available on request - From -40 °C to 300 °C haptic devices the highest homogeneous
pressure - Gas-, liquid-, or - Different mercury and LED - Humidity range from 5 % to magnetic fields and high shear
- Low- and high-volume cells self-pressurization can be light sources as well as filters 95 % RH - Voltage range: 0 kV to rate measurements
available used to control the pressure for the emission of discrete - From 5 °C to 120 °C 12.5 kV DC (AC on request) Read more:
www.anton-paar.com/apb-mrd
- Low-friction ball bearings - Low-friction and highly wavelengths are available - Can be used with standard - From -50 °C to 300 °C
for precise rheological resistant jewel bearings enable - Usable with Peltier, electrical, and specialized measuring - For parallel-plate and I M M O B I L I Z AT I O N C E L L ( I M C )
measurements characterization even of and convection temperature systems for rheology and concentric-cylinder geometries
- Choose between versions in rod-climbing viscoelastic fluids devices (part of the DMA in torsion, tension, - Suitable for rotational and - Investigate the immobilization
stainless steel, titanium, or - Internal construction of RheoOptics toolbox) bending, and compression oscillatory tests as well as kinetics and water retention
Hastelloy if you investigate titanium or Hastelloy for - Combinable with Raman or - Combinable with UV light, squeeze flow of paints, coatings, and
aggressive media improved resistance to IR spectroscopy to determine powder rheology, and - Customized solutions for slurries by simulating process
- Flow-through option available aggressive materials changes on the molecular tribology combination with polarized conditions
- Flow-through options available level simultaneously - AT Pat. 513661 imaging or microscopy - US Pat. 6098450, 1998
Read more: Read more: Read more: Read more: Read more:
www.anton-paar.com/apb-pressure-cell www.anton-paar.com/apb-uvlcs www.anton-paar.com/apb-hmo www.anton-paar.com/apb-erd www.anton-paar.com/apb-imc

22 23
Accessories for THE OPEN RANGE OF POSSIBILITIES WITH AN MCR RHEOMETER DOES NOT STOP AT SHEAR RHEOLOGY.
A COMPREHENSIVE SELECTION OF EASILY INTEGRATED ACCESSORIES TRANSFERS THE CAPABILITIES OF
THE INTRINSICALLY MODULAR MCR SERIES INTO OTHER MATERIAL.
extended material characterization

FURTHER ACCESSORIES

SmartPave rheometer and


Asphalt Setup
- Designed for quality control
and routine measurements
of asphalt and bitumen
according to international
standards
Read more:
www.anton-paar.com/apb-smartpave

Tribology Cells
- Allow the tribological
characterization of a broad
range of applications from
lubricants, biomaterials, and
polymers to food
- For extended Stribeck curves,
static friction, limiting friction
(including break-away torque)
- US Pat. 9702809,
AT Pat. 505938
EXTENSIONAL RHEOLOGY Read more:
www.anton-paar.com/apb-mcr-tribometer
DYNAMIC MECHANICAL - Extensional flow happens L A R G E - PA R T I C L E R H E O L O G Y
A N A LY S I S ( D M A ) in many applications - Measure the flow properties
- DMA is an analytical method and processes, often in I N T E R FA C I A L R H E O L O G Y of samples with large particles Powder rheology
for determining the viscoelastic combination with shear flow SYSTEM (IRS) (typical particle size range of - Perform true powder rheology
properties of materials under - Gain information about - Precise studies of the flow 1 mm to 10 mm) to analyze bulk solids in
sinusoidal load molecular structure, properties of interfacial layers - Typical applications: building any state, from fluidized to
- The temperature of the sample branching, temperature - Study the flow properties of S TA R C H C E L L materials (e.g. cement, consolidated powders
and the frequency of the load stability, shrinkage, relaxations, two-dimensional liquid-liquid - Starch pasting cell for analysis concrete, plaster), food - Powder Shear Cell: ideal for
are often varied to determine and brittleness as well as the and liquid-air interfaces of starch gelatinization or products, slurries, and sludges determining the flow behavior
transitions within the material adhesion and peel strength of - Comprehensive rheological pasting behavior of consolidated powders and
behavior (e.g. glass transition materials investigations of emulsion and - Simulate the temperature and Ball Measuring System (BMS) their time-dependent behavior
temperature) - Typical applications: polymer foam stability pressure conditions of food - From -10 °C to 70 °C - Powder Flow Cell: an
- Typical applications: polymers films and fibers, melts, - Typical applications: emulsion production processes - Measuring principle is an innovative and scientific
and composites, foams, gels, adhesives and foam stability, food - Typical applications: food, eccentrically rotating ball in a approach towards powder
food systems, elastomers products, detergents, life confectionery products, cup which avoids undesired characterization offering a
- The Universal Extensional science paper and packaging, slipping, gliding, and wide range of test methods
- MCR is the world’s most Fixture for a configuration pharmaceuticals, adhesives disturbing edges (US Pat. 10031057)
versatile platform for both with two EC drives (UXF-TD) - From 5 °C to 70 °C Read more:
www.anton-paar.com/apb-powder
dynamic mechanical analysis enables measurements - Bi-cone measuring geometry - Max. heating rate: 60 °C/min; Building Material Cell (BMC)
and rheological investigations, with unprecedented torque or a Du Noüy ring, positioned max. cooling rate: 45 °C/min - From 0 °C to 90 °C Find more details about these devices
allowing you to perform and strain resolution on directly in the interface - Robust and easy-to-clean cup - Changeable, robust, and and accessories in separate brochures.

DMA in all working modes low-viscosity films and fibers - Even the weakest interfacial and stirrer made of stainless easy-to-clean inset cage and
(torsion, tension, bending, (US Pat. 9766172) structures can be measured steel special stirrer
compression) - The Sentmanat Extensional with the MCR low-torque - Unique small sample amounts - Resistant to abrasive
- From -160 °C to 1000 °C Rheometer (SER) system capabilities and the of around 18 mL materials, prevents sample
- Touch-control for fast and is perfectly suitable for TruStrain™ feature - RVA stirrer design available slippage, and provides
easy positioning of the extensional tests at high - Flow-through option available - Optional Starch Pressure Cell improved mix-up effects to
geometries torques on request up to 30 bar and 160 °C avoid separation
Read more: Read more: Read more: Read more: Read more:
www.anton-paar.com/apb-dma-mcr-702 www.anton-paar.com/apb-uxf-ser www.anton-paar.com/apb-irs www.anton-paar.com/apb-sc www.anton-paar.com/apb-bms-bmc

24 25
Special AS WELL AS BEING THE MOST CITED RHEOMETER SERIES, THE MCR IS THE MOST POPULAR RHEOMETER IN
THE WORLD WITH MORE MODELS SOLD THAN ANY OTHER RHEOMETER ON THE MARKET. THE SECRET TO THIS
SUCCESS: LISTENING TO CUSTOMER FEEDBACK AND CREATING OUTSTANDING TECHNOLOGY IN RESPONSE.
instruments AS WELL AS CREATING AND CONSTANTLY IMPROVING OUR “CLASSIC” BENCHTOP RHEOMETERS, OUR TEAM HAS
PRODUCED A NUMBER OF SPECIAL SOLUTIONS.

and customized
solutions

CUSTOMIZED SOLUTIONS FOR HIGH-THROUGHPUT


DEVICES AND ACCESSORIES RHEOMETER (HTR)

H I G H - T E M P E R AT U R E HTR rheometer automation for high


RHEOMETER
Based on decades of experience in FRS 1600 / FRS 1800
sample throughput and complex
rheometry and rheology, Anton Paar sample handling
can make nearly everything possible. - The only device on the market - The world’s first fully automated
With our in-house production in which allows rotational and high-throughput rheometer
Austria and a dedicated R&D team oscillatory rheometry at - High-throughput operation with
just next door, we develop and temperatures above 1000 °C 96 samples in the standard rack
DSR 502 RHEOMETER HEAD
supply customized products for all - Measure samples at - Different types of racks for
kinds of specific applications. Don’t - Modular rheometer measuring temperatures up to 1730 °C pipettes, syringes, and trim
hesitate to contact us in order to head with separate control unit in air or also under inert gas blades, and temperature-
discuss your requirements and to - Full flexibility for integration into atmosphere controlled sample storage (down
find a customized solution for your tailor-made setups - Ideal for research and process to 4 °C) are available
measurement task. - Customized solution on your optimization of slags, metals, - Built-in flexibility makes it the
request: Support from different ceramics, and glass melts ideal choice for sophisticated
departments including CAD - Combines a high-precision and high-throughput R&D or QC
THINK BEYOND “CLASSIC” designers and engineers to MCR rheometer head and an air work
RHEOLOGY create your product bearing with a lab furnace in a
- For implementation into process safety cage HTR compact – Automated MCR
Based on the air-bearing rotational environments, for online - The normal force measurement rheometer platform in benchtop
and linear drives MCR rheometers and inline measurements, enables the characterization of design
offer unique accurate and sensitive and combination with a fully the melting behavior - High-throughput operation
technologies to control torque, force, automated system - Additional options like a gas-tight with 36 samples in two trays of
deflection, displacement, and speed. - Ideal for rheological option for measurement in a 18 cups each
The additional combination with the investigations in formulation and defined gas atmosphere are - Additional modules for growing
extensive customization possibilities material handling areas or in available on request automation needs (e.g. bar code
makes the MCR rheometers valuable high-temperature vessels - Customized measuring reader for sample identification,
tools for all kinds of precision - High accuracy in a vast viscosity geometries and materials wide range of measuring
mechanics measurements, e.g. for range and oscillatory mode available to avoid interactions geometries, and ventilation
the most sensitive mechanical testing - Quick integration and exchange between sample and measuring for volatile and solvent-based
of different types of bearings and of measuring geometries geometry material samples)
mechanical counters. Read more: www.anton-paar.com/apb-dsr Read more: www.anton-paar.com/apb-frs Read more: www.anton-paar.com/apb-htr

26 27
Academy
and education
Successful work in the field of rheology is not only determined by the technology
We are confident in the high quality
you use, but also by the partner that helps you solve your rheological challenges. of our instruments. That’s why we provide
Anton Paar is here to give you support. full warranty for three years.

SIGN IN FOR OUR RHEOLOGY ENJOY ACCESS TO AN GET IN TOUCH WITH


COURSES AND WEBINARS E X T E N S I V E D ATA B A S E OUR EXPERTS
A L L O V E R T H E W O R L D AT T H E OF KNOWLEDGE All new instruments* include repair for 3 years.
I N T E R N AT I O N A L A C A D E M Y
Anton Paar provides excellent
You avoid unforeseen costs and can always rely on your instrument.
OF RHEOLOGY As a customer of Anton Paar you service and support. With more
Alongside the warranty we offer a wide range of additional services and maintenance options.
We regularly offer courses in our enjoy access to a large database than 30 Anton Paar subsidiaries
subsidiaries worldwide and also of useful application reports, and numerous responsible partners * Due to the technology they use, some instruments require maintenance according to a maintenance schedule.
organize online courses or exclusive product documentation, and tutorial worldwide a rheological expert is Complying with the maintenance schedule is a prerequisite for the 3-year warranty.
group courses for customers on videos, as well as benefitting from close to you and happy to help, in
request. The program covers our comprehensive background your language and free of charge.
classes for you to learn the basics of knowledge on the theory (e.g. from Call us for advice on test definitions Service and support directly from the manufacturer
rheology, optimize your work with the our wiki and the book “Applied or to discuss the rheological Our comprehensive service provides you with the best individual coverage for your
RheoCompass software, and also Rheology” by the renowned rheology challenges you are facing. investment so that maximum uptime is ensured.
gain application-specific knowledge, expert Thomas Mezger): keeping your investment healthy

e.g. for investigations on food,


Application reports and product documentation:
polymers, asphalt, pharmaceuticals, www.anton-paar.com/apb-documents SAFEGUARDING YOUR INVESTMENT
and many more. You can also learn Background knowledge: Regardless of how intensively you use your instrument, we help you keep
more about specialist subjects and www.anton-paar.com/apb-basics
your device in good shape and safeguard your investment – including
meet our experts for discussions Order the book: a 3-year warranty.
www.anton-paar.com/apb-applied
online by taking part in one of our
free-of-charge webinars.

Course program and registration:


www.anton-paar.com/apb-academy THE SHORTEST RESPONSE TIMES
We know that sometimes it’s urgent. That’s why we provide a response
Webinar overview and registration:
www.anton-paar.com/apb-webinars to your inquiry within 24 hours. We give you straightforward help from
real people, not from bots.

CERTIFIED SERVICE ENGINEERS


The seamless and thorough training of our technical experts is the
foundation of our excellent service provision. Training and certification
are carried out at our own facilities.

at your location

OUR SERVICE IS GLOBAL


Our large service network for customers spans 86 locations with a total of
350 certified service engineers. Wherever you are located, there is always
an Anton Paar service engineer nearby.

28 29
MCR 702e MultiDrive MCR 702e MultiDrive
MCR 702e Space MultiDrive MCR 702e Space MultiDrive
Configuration with Configuration with Configuration with Configuration with
MCR 102e MCR 302e MCR 502e Power 1 EC motor 2 EC motors MCR 102e MCR 302e MCR 502e Power 1 EC motor 2 EC motors

TECHNICAL SPECIFICATIONS ADDITIONAL DEVICE FEATURES


Device display with remote
Bearing design Air, fine-pored carbon
control of software
(decoupled from measuring sensor;     
Motor design Electronically Commutated (EC) - Permanent Magnet Synchronous Motor mechanical and electromagnetic
interference prevention)
Displacement transducer
design
High-resolution optical encoder
Direct strain/stress controller     
Normal force measurement
TruRate™ / TruStrain™
design 360° capacitive sensor, non-contacting, fully integrated in bearing (sample-adaptive controller)
Optional    
(US Pat. 6167752, 1996)
Raw data
Active thermal management
(LAOS, waveform)
Optional    
of bearing and normal force     
sensor Normal force profiles
(set and read)     
Separate Motor
Working modes Combined Motor Transducer (CMT) Transducer (SMT), Velocity profiles, tack, squeeze Optional    
Counter-Movement1)
Automatic gap control/setting
Minimum torque (rotation) 5 nNm 1 nNm 200 nNm 1 nNm (AGC/AGS)     

Electronic trim lock for


Minimum torque (oscillation) 5 nNm2) 0.5 nNm 100 nNm 0.5 nNm measuring geometry     

Fully automatic temperature


Maximum torque 200 mNm 230 mNm 300 mNm 230 mNm calibration     

Minimum angular deflection TruGap™


(set value)
0.5 µrad 0.05 µrad (permanent control of the
real measuring gap)
Optional Optional Optional Optional Optional
Maximum angular deflection (US Pat. 6499336, 2000)
(set value)
∞ µrad
T-Ready™8)
3) (detection of sample
Minimum angular velocity 0 rad/s 0 rad/s 0 rad/s 0 rad/s 0 rad/s temperature equilibrium time)     
(US Pat. 8904852, 2011)
Maximum angular velocity 314 rad/s 220 rad/s 314 rad/s 628 rad/s
Maximum speed 3000 1/min 2100 1/min 3000 1/min 6000 1/min Toolmaster™
(measuring geometries and
accessories, storing of zero-gap)     
Minimum angular frequency4) 10-7 rad/s
(US Pat. 7275419, 2004)

Maximum angular frequency5) 628 rad/s QuickConnect coupling for


Maximum frequency 100 Hz measuring geometries     
(one-hand operation, screwless)
Normal force range -50 N to 50 N -70 N to 70 N -50 N to 50 N Trimming mirror
(360° sample blind spot prevention)     
With exposed support plate6)
 Optional   7)
 7)
(WESP / Space) Three-point support of device
(three robust feet for tool-free one-hand     
Without support plate (WSP)  Optional    alignment)

Three-point support for


444 mm x 753 mm
444 mm x 753 mm mounting of measuring cells
x 586 mm (wobble prevention, no misalignment     
x 586 mm
444 mm x 678 mm 444 mm x 733 mm 444 mm x 753 mm after changing of cells)
Dimensions (W x H x D)
x 586 mm x 586 mm x 586 mm Space: Space:
-160 °C to +600 °C
212 mm x 767 mm x 212 mm x 767 mm Maximum temperature range -160 °C to +1000 °C
(950 °C9))
554 mm x 554 mm
48 kg 58 kg
Maximum pressure range up to 1000 bar n/a
Weight 42 kg 46 kg 47 kg
Space: 51 kg Space: 61 kg Ready for DMA in torsion and
tension     

Ready for linear drive


(DMA in tension, bending, and
RHEOCOMPASS SOFTWARE FEATURES AND SPECIFICATIONS: compression)     
(US Pat. 9574983, 2015)
Get even more out of your rheometer with the most powerful rheometer software on the market
Read more: www.anton-paar.com/apb-rheocompass Ready for tribology     
Ready for powder flow and
shear rheology     

1)
US Pat. 8453496
2)
2 nNm with activated TruStrainTM option
3)
In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode depending on measuring point duration and sampling rate
4)
Theoretical value (duration per cycle = 2 years)
5)
Higher frequencies are possible using multi-wave functionality (942 rad/s (150 Hz) or even higher, depending on measuring system and sample)
6)
Enlarged working space underneath the support plate (flange)
7)
MCR 702e Space MultiDrive: Unique maximized workspace below the rheometer support plate and on both sides of the instrument
8)
Depending on used temperature device
9)
Customized systems used in CTD 1000

30 31
© 2021 Anton Paar GmbH | All rights reserved.
Specifications subject to change without notice.
C92IP001EN-N
document Number

www.anton-paar.com

You might also like