Technical Information

CSES-ID: TNEU1400294EN
Version 1.0
Status: 15. July 2014
Product: Zeus MLK/BK Series

New SSD Board firmware version 6.05m


TECHNICAL INFORMATION
2  TNEU1400294EN N

Background
To further improve and decrease the SSD Board failure ratio, a new USB tool has been released. The new USB
tool will update the SSD Board firmware to version 6.05m. To minimize the SSD board failure ratio, please from
now on use the new USB tool whenever you need to perform a SSD Board firmware update.

Symptom
In very rare cases even with SSD board firmware version ver. 6.03m the “continuous reboot problem”, which has
been fixed with this version, can reappear.

Cause
The cause is a new bug in the SSD board firmware version 6.03m where a process to increment a counter for
abnormal block handling is missing. Within a timeframe of 5 years the chance that data can be corrupted due to the
missing process (causing continues rebooting) is between 0.3 – 1%.

Countermeasure
1. KMI released a new USB tool which has to be used to upgrade SSD Board firmware. The tool will update
SSD Board firmware 6.01n/6.02n/6.03m to 6.05m.
Please download the USB tool from CSES
DLBT1412119EN.

2. Additionally the 4th generation firmware has implemented the capability to automatically update SSD Board
firmware version 6.03m to 6.05m, in case the firmware update will be performed via USB. If the firmware
update will be performed via ISW SSD Board firmware update process will not be done.
Please download the firmware from CSES as soon it will be released. Release is planned for end of July.
TECHNICAL INFORMATION
 TNEU1400294EN 3

Action to be performed
1. In case the SSD Board has to be exchanged and you received a SSD Board with SSD Board firmware
version 6.0.3m (Board with white dot on the chip). You can
a. Install the new SSD Board and use the new USB tool to update the SSD Board firmware to version
6.05m.
th
b. Install the new SSD Board and update the firmware to the 4 generation firmware. This is
recommended for all cases where the customer environment does not require staying on the
th
current firmware level, due to firmware customisation or application dependencies. The 4
generation firmware includes new features for Service Productivity Improvement (SPI) wherefore it
is recommended to upgrade, if possible.

If your customer situation allows the firmware update, perform the firmware update as usual with a
prepared USB Stick installed in the USB Service slot. After the machine has been switched on and
booted into the firmware update mode, then on the firmware update screen upper right corner, you
will find the current installed SSD Board firmware version.

After successful update, the Firmware update screen will show SSD Download completed like
shown below.

Remark: In cases where you update a machine which has already SSD Board firmware version 6.05m
installed the SSD Download message will not be shown in the above Firmware update screen.
In cases where you update a machine which still has SSD Board firmware 6.01n/6.02n installed
the SSD Download message will show a “NG” because the firmware can only update SSD board
firmware 6.03m. In this case please use the new USB tool to update the SSD Board firmware to
version 6.05m
TECHNICAL INFORMATION
4  TNEU1400294EN N

2. In case you have already received a SSD Board, with SSD Board firmware 6.05m installed just exchange
the SSD Board as usual.

The new SSD Boards with firmware version 6.05m can be identified with a green dot on the box as well as
by the change of the ID number from 13XXXX to 14XXXX on the Board itself. See on below SSD Board
picture the red circle to find the location of the ID.
TECHNICAL INFORMATION
 TNEU1400294EN 5

“Upgrade Procedure”
1. Open the front cover of the device

2. Make sure that the Main Power Switch is OFF

Main Power Switch

3. Open the right rear cover


TECHNICAL INFORMATION
6  TNEU1400294EN N

4. Remove [Screw A], store it in the open front cover and push up the USB Slot cover so the Service
USB slot can be accessed.
TECHNICAL INFORMATION
 TNEU1400294EN 7

5. Connect the USB stick to the Service USB Slot.

6. Take care that the power cable is firmly connected to the MFP.
TECHNICAL INFORMATION
8  TNEU1400294EN N

7. Turn the main power switch ON.

8. CHECK if “Press [START] to begin the SSD Firmware update” is shown in the display.
9. Press [START] key which is shown on the control panel (the download will begin).

Press START

DO NOT TURN OFF THE MAIN SWITCH


WHILE THE UPDATE IS RUNNING!!!
If a power failure occurs the following two symptoms may happen:
A) “Continuous rebooting”
In this case it is necessary to exchange the SSD-Board with a new one.
Start the device with MFP firmware. After successful MFP firmware update the SSD-Board
firmware need to be updated.

B) “No boot up”


In this case you do not need to exchange the SSD-Board. You have to update the MFP Firmware.
After successful update of the MFP firmware, please perform the recommended SSD-Board
firmware update procedure.
TECHNICAL INFORMATION
 TNEU1400294EN 9

Attention!
10. CHECK if “Download OK Please turn off the main SW” is shown on the control panel and the
START key is blue colored.
11. If the download is OK please turn the main switch OFF.

12. To verify if the update was successful turn the main switch on and enter the CE mode and check if
the MFP Firmware version is the same as before the SSD Board firmware update.
13. We like to recommend to sign the device, e.g. with a red dot on the type label. This will match to the
labeling of the devices which are modified in the warehouse.
TECHNICAL INFORMATION
10  TNEU1400294EN N

During the update process the following conditions may happen:


1. Download NG

 Attempt SSD Board FW download once again


 Reseat SSD board if failed again
2. Error Code 3300/3320
Error code [3300] is caused by the SSD backup failure similar with [3320].
Therefore, when this trouble code will occur in the field, please proceed with the following steps:
 Turn the main power Off and On
 Perform the HDD format
 Perform the SSD update tool again

Remark: If the error code still exists on the machine, please replace the SSD board with a new one.

Error Code [3320] happens when performing the SSD Board firmware update with the USB tool. During the
update all area in SSD should be dumped once. During the update process there is the possibility that while
the unused area is read an ECC error occur which causes the error code [3320].

KMI recognized that this Error Code [3320] is caused by the old type of SSDB which was mounted on Zeus
MLK machine in early stage of mass-production.
3. After replacement of the SSD Board, new SSD Board fails again.
The new SSD board may be physically damaged Please exchange once again with a new one.
4. Detected that the number of BAD Block exceed limit
 SSD Board works for now but it may happen that it need to be replaced sometime within its life time
 It is recommended to replace the SSD Board on the next visit as a preventive action.
TECHNICAL INFORMATION
 TNEU1400294EN 11

5. The upgrade tool on the USB does not match to MFP


 Use the USB with correct upgrade tool

6. SSD Board FW has been already updated


 No further action required

7. The result of pattern check is always NG


Please be aware if you do the SSD Pattern check, in self-diagnostic mode, the result of pattern check is
always NG.
As described on TNBT1400012EN, when the original SSD board will be replaced to a spare one, the Pattern
Check of SSD Check in Self-Diagnostic mode always shows "NG", although the SSD board has no defects.
Even after update of the SSD Board firmware with the update tool, the Pattern Check of SSD Check in Self-
Diagnostic mode will show "NG". This is because for technical reason the update tool needs to erase all data
in the SSD Board before updating the SSD Board firmware.
The reason why this symptom occurs is, because the key data for SSD pattern check in Self-Diagnostic mode
are entered by a different tool in factory side and this key data cannot be restored when replacing SSD Board
or performing the SSD Board firmware update with the update tool.
Therefore, if there is a need to check the SSD by the Self-Diagnostic please check its condition with the R/W
check.
TECHNICAL INFORMATION
12  TNEU1400294EN N

Appendix – KM Project names

Project name Konica Minolta


Minerva 2nd 0/1 bizhub C54e/654e
Minerva 0/1: bizhub C754/654
Donau DS: bizhub C652 DS
A3 - Color

Donau 1/2/3: bizhub C652/552/452


Mosel 1/2/3: bizhub C650/550/451
Zeus MLK X/0/1/2/3 bizhub C554e/454e/364e/284e/224e
Zeus X/0/1/2/3: bizhub C554/454/364/284/224
Amur 1/2/3: bizhub C360/280/220
Thames 1/2/2.5: bizhub C353/253/203
Rhein 1/2/2.5/3: bizhub C450 /C352 /C300 /C250

Project name Konica Minolta


Minerva BK 2nd 0/1 bizhub 754e/654e
Minerva BK 0/1 bihub 754/654
LaPlataM 1 /2 bizhub 751/601
LaPlata 1 /2 bizhub 750/600
A3 - B&W

Donau BK 1/2 bizhub 652/552


Zeus BK X/0/1/2/3 bizhub 554e/454e/364e/284e/224e
GangesM 1 /2 /3 bizhub 501/421/361
Ganges 1 /2 /3 bizhub 500/420/360
Taiga 0/1/2/3 bizhub 423/363/283/223
TigrisM 1 /2 /2.5 bizhub 362/282/222
Tigris 1 /2 /2.5 bizhub 350/250/200

Project name Konica Minolta Open Model


Venus 1/2 MFP bizhub C3850/C3350
A4 - Color

Citrine MFP/PHH/AIO bizhub C35/C35P/C25 mc4790MF/mc4750


Emerald-PH bizhub C30P mc5570CK
Sapphire-PA/PD bizhub C20/C20P mc4695MFDN/mc4650DN
Garnet-AIO MLK bizhub C10 mc2590MF
Topaz P bizhub 10P mc2550CK

Project name Konica Minolta


Kronos 1/2 MFP bizhub 4750/4050
A4 - B&W

Kronos 2/3 AIO bizhub 4020/3320


HFFV2: bizhub 43
TaigaY 0 /1: bizhub 42/36
Orion 1: bizhub 21
Turnkey AIO/SFP bizhub 20/20P
TECHNICAL INFORMATION
 TNEU1400294EN 13

Personal Notes

You might also like