Professional Documents
Culture Documents
OUR EASIEST
DEVICE YET
Diagnostic testing, and everything
that goes with it, isn’t always easy.
But the i-STAT Alinity system
can make it easier.
With-patient Testing.
Revolutionized.
FOR IN VITRO DIAGNOSTIC USE ONLY • INTENDED TO BE USED BY TRAINED MEDICAL PROFESSIONALS • NOT ALL PRODUCTS ARE AVAILABLE IN ALL REGIONS
CHALLENGES TO DELIVERING POINT-OF-CARE TESTING CAN HELP
QUALITY CARE ARE INCREASING ADDRESS THESE CHALLENGES
Healthcare organizations continue to be challenged to provide quality healthcare in the face Despite the many changes to the healthcare landscape, goals for healthcare providers remain
of increased demand for care, escalating costs and funding constraints. To meet these the same:
demands while providing quality care, many healthcare organizations have decentralized
care delivery to peripheral settings to drive more appropriate use of resources and to serve
the broadest patient population possible.
URGENT CARE
EASY-GRIP HANDLING
•E
rgonomic design makes use balanced,
comfortable and secure
DURABLE CONSTRUCTION
• Robust construction for fast-paced
environments
• Built with materials that can resist
damage
HIGH-RESOLUTION
CAMERA
•C
aptures 2-D barcodes with picture ID
EASY-TO-REPLACE,
RECHARGEABLE BATTERY
•A
lways ready to use
ENABLE GREATER
QUALITY CONTROL & COMPLIANCE
RELIABLE FEATURES DRIVE GLOBAL COMPLIANCE AND REINFORCE OVERSIGHT AND CONTROL
eGFR – Estimated Glomerular Filtration Rate eVAS – Electronic Value Assignment Sheets; PPID – Positive Patient Identification; QC – Quality Control
SOPHISTICATED CONNECTIVITY
TECHNOLOGY
CONNECTIVITY TO ABBOTT CYBER SECURITY
MANAGED SERVER
• No protected health information,
• Lowers the administrative burden by operator information or device logs can
seamlessly transferring eVAS from the be transmitted to the Abbott Managed
Abbott Managed Server to the instrument Server
• Avoids unplanned downtime of the • Access to software download and
instrument by allowing the operator to installation is limited to approved and
download updated software from the authenticated operators
Abbott Managed Server at their discretion
SECURED APPLICATIONS
WIRELESS AND/OR WIRED
CONNECTIVITY OPTIONS • AlinIQ NCi is used to configure network
settings and runs as a local application SUPPORTING IMPLEMENTATION
• Allows efficient management of patient
data through wireless or wired
behind a secured firewall. AND ONGOING USE
transmission of data to EMR or data • AlinIQ CWi manages customization
manager profiles. Abbott Point of Care offers a variety of resources to support the use of the i-STAT Alinity
system at your facility, including the assurance of expert assistance whenever needed.
SENT TO
INSTRUMENTS: TO LEARN MORE ABOUT AVAILABLE SUPPORT RESOURCES FO YOU AND YOUR
- OPERATOR LISTS
- PATIENT LISTS
- CARTRIDGE LISTS STAFF, VISIT OUR WEBSITE AT WWW.POINTOFCARE.ABBOTT OR CONTACT
YOUR ABBOTT REPRESENTATIVE.
ADMINISTRATOR HOSPITAL NETWORK
INSTRUMENT FLEET
*Functions with other supported data management software. *Available in multiple languages
EXTENSIVE CARTRIDGE MENU FOR i-STAT TEST CARTRIDGES:
DIFFERENT CLINICAL SETTINGS QUALITY BY DESIGN
The i-STAT Alinity system provides a comprehensive menu of tests on a single platform. THE DIFFERENCE OF SINGLE-USE Thousands of cartridges are tested daily
TECHNOLOGY to be sure they meet performance
The i-STAT Alinity system is built on the same tried and tested technology found in the standards for accuracy, precision, and
i-STAT 1, which is used in more than 10,000 healthcare facilities around the world. The i-STAT Alinity single-use cartridge
reliability before they leave the factory.
design means that each cartridge is used
just once, then discarded. QUALITY AT THE CARE FACILITY
CARTRIDGES
Analyte concentrations are determined An onboard quality system within the
EC8+ CG8+ EG7+ CHEM8+ EG6+ CG4+ 6+ G3+ EC4+ E3+ G Crea ACTk directly in a single whole-blood sample i-STAT Alinity instrument automatically
without dilution. monitor nearly 150 sensor characteristics
CHEMISTRIES/ that may impact the accuracy of results.
ELECTROLYTES Because of the single-use design, the drift
Sodium (Na) or degradation associated with multi-use If any characteristic falls outside of the
Potassium (K)
systems is eliminated. expected range, the results are rejected
by the instrument.
Chloride (Cl)
QUALITY EMBEDDED IN THE
Anion Gap‡ MANUFACTURING PROCESS Because the system uses automated
Ionised Calcium (iCa) quality controls and requires minimal
Biosensors in i-STAT cartridges are operator interaction, the risk of user error
Glucose (Glu)
fabricated with production and process is also reduced.
Urea Nitrogen (BUN) controls embedded throughout the
Creatinine (Crea) manufacturing process.
Lactate
HEMATOLOGY
SENSORS
Hematocrit (Hct)
CONTACT PADS
Hemoglobin (Hgb)‡ BLADDER
SENSOR CHANNEL
BLOOD GASES
CLOSURE
pH
PO2
TCO2†
SAMPLE CHAMBER
HCO3‡
COAGULATION
ACT Kaolin
‡ calculated
†calculated (except for Chem8+)
EASY
User-friendly design and advanced features
that make the i-STAT Alinity system easy
to use and manage
ACCURATE
Lab-quality results with broad menu
availability
CONNECTED
Built-in secure cloud technology for
remote connectivity
For in vitro diagnostic use only. Not all products are available in all regions. Intended for audiences outside of the U.S.
i-STAT and Alinity are trademarks of the Abbott Group of Companies in various jurisdictions.
© Abbott Point of Care Inc. www.pointofcare.abbott i-STAT Alinity Brochure 2736.1 02/20