You are on page 1of 5

Cleaning

ROOM
3 m2

SECURITY
ROOM
17 m2
U
P

STAIRCASE-B-

seating
seating
arm rest arm rest

seating

seating

seating
seating
arm rest arm rest
arm rest arm rest

seating
seating

seating

seating
arm rest arm rest

seating
seating
arm rest
seating seating

arm rest
seating seating

PARTITIONS&WALL FINISH'S LAYOUT


C

Cleaning
ROOM 3000 3000 3000
3200 3200 3200

3 m2
3200

A A
3100 3000 3100 3100
3000
3200 3200 3200
3000 3000 3000 3000
FOR KEY NOTE CODES REFER TO
SECURITY DRAWING NUMBER 1706/A/002
ROOM 3000
FOR SECTION-AA&BB REFER TO
DRAWING NUMBER 1706/A/007
3000

17 m2 FOR SECTION-CC & DD REFER TO


DRAWING NUMBER 1706/A/008
U

3000 2900
P

3000
FOR SECTION-EE & FF REFER TO
DRAWING NUMBER 1706/A/009
B B
STAIRCASE-B-
3200
3200
3000
3000 2900 3100 3000

3000 3000 3200


3000

C
3000

F E
3000
3000

3000

3000

3200

3000
3000
D 3000 3200 D 3000
BRANCH 20 KVA UPS ELECTRICAL REQUIRMENTS 3000
3000

2600

F E

CEILING LAYOUT
BRANCH 3 KVA UPS ELECTRICAL REQUIRMENTS
Cleaning
ROOM
3 m2
T T T T T T

T T

T
SECURITY
ROOM T

17 m2
U
P

STAIRCASE-B-

seating
seating
T
arm rest arm rest T T

seating

seating

seating
seating
VJA
arm rest arm rest
arm rest arm rest

seating
seating
T T

seating

seating
T
arm rest arm rest

seating
seating
T
T

arm rest
seating seating

arm rest
seating seating T

VJA VJA

T T T
VJA VJA VJA

T T T

T
T

VJA

T
T

T
T
WH

T
VJA
DB REQUIRED SECURED
COVERING WITH KEY

T
T
T
VJA

WH

TV
T

T
Cleaning
ROOM
3 m2

SECURITY
ROOM
17 m2
U
P

DCS
STAIRCASE-B-

seating
seating
arm rest arm rest

seating

seating

seating
seating
arm rest arm rest
arm rest arm rest

seating
seating

seating

seating
DCS arm rest arm rest

seating
seating
arm rest
seating seating

arm rest
seating seating

DCS

DVR

DCS

CC TV AND SECURITY LAYOUT


Cleaning
ROOM EXIT
E
3 m2
DS DS DS DS DS

E DS

Co2
E E E
SECURITY
ROOM E

AFFF Co2
17 m2 Co2 AFFF E
U
P

E
DS
STAIRCASE-B- E
DS
DS
DS DS

E
DS E

EXIT
E EXIT
EXIT

AFFF
DS

Co2
E
E

EXIT
E DS
E E E

AFFF
DS

Co2
Co2
DS DS DS

FB
E Co2 Co2
DH

AFFF

Co2

Notes
Landing valve fire hydrant outlet DR
for dry system 2.5
Fire Extinguishers vaporising H
liquid type (BCF)

Manual Fire Alarm Call Point

Audible Warning Devices

"Fire Exit" Signs E

Automatic Fire Detection "Smoke" DS

Automatic Fire Detection "Heat" DH

Emergency LIghting Point E

Hose Reel

Fire Alarm Indicator Panel IP

The Period of Fire Resistance


is shown in Minute 60

Fire Blanket (S) FB

Exit Light Box

Fire Alarm Control & Indication


Panel
One Inlet Fire Hydrant - Male
type for dry System 1.5
Fire Extinguishers foam type
AFFF
AFFF
Fire Extinguishers Carbon Co2
dioxide type - Co2
Fire Extinguishers WT
Water

FIRE ALARM AND FIRE FIGHTING LAYOUT


Sprinkler Head