B&R X67 system - Integrated automation

Mount, connect and you‘re Global presence X67 I/O


ready to go Solid partnership System overview

Remote I/O with IP67 protection The shortest commissioning times


With a credit card design and IP67 rating provi- Pre-assembled standard cables make it possible
ding protection in the harshest industrial environ- for the mechanic to make the necessary connec-
ments, this new dimension in remote I/O techno- tions himself, relegating wiring errors to history
logy can be installed directly in the machine room, where they belong. Commissioning can begin im-
freeing up valuable space in the control cabinet mediately when machine construction is started,
and working just as fast as a centralized soluti- with time-consuming inspection of the wiring no
on. Experience ultimate freedom in your choice of longer necessary.
communication fieldbus with the advanced X67
I/O system. Minimized service costs
Correcting errors is easy since individual sensors
Traditional I/O systems are located centrally in the and actuators can be quickly replaced using plug
control cabinet, with extensive wiring required for connections. Extensive diagnostic functions al-
sensors and actuators. In addition, modular machi- low errors to be detected immediately.
ne designs often require intermediate connections
with multi-pin connectors. Remote I/O modules can One system for all machine designs
only reach their full potential, however, if additional Whether a compact machine or an extensive system,
distribution boxes can be eliminated completely. this I/O system can be adapted to the machine‘s ar-
This is why the optimal solution has to include I/O chitecture to meet every possible demand.
modules with robust IP67 protection that can be

© 11/2013 by B&R. All rights reserved worldwide.


placed directly in harsh industrial environments.
Highlights
Reduced wiring
Instead of having to extensively wire each indi- < Compact and ergonomic
vidual sensor or actuator to the control cabinet < IP67 protection
over long distances, the X67 system reduces the < Excellent EMC properties

MM-E01343.084
amount of work down to a single bus cable and < Open for all fieldbus systems B&R Corporate Headquarters
a 24 VDC power supply. This applies to the entire < Seamless integration of IP20-rated I/O Bernecker + Rainer B&R Strasse 1 t +43 7748 6586-0 office@br-automation.com Your local contact
machine and cuts costs considerably. Industrie-Elektronik Ges.m.b.H. 5142 Eggelsberg, Austria f +43 7748 6586-26 www.br-automation.com www.br-automation.com/contact
X67

Digital M8 standard M8 high-density Digital M12 M12 high-density Analog M12 standard Miscellaneous M12 standard Bus controllers M8 standard M8 high-density M12 high-density
inputs/outputs inputs/outputs inputs/outputs

X67DI1371.L12 X67AI1223 X67BC8321-1 X67BC8321.L12


Digital inputs 4 inputs X67DC1198
8 digital channels 16 digital channels
- 16 inputs
X67DI1371 X67DI1371.L08 24 VDC 12-bit 2 SSI absolute encoders 5 VDC or
Sink configurable as inputs configurable as inputs
8 inputs 16 inputs Analog inputs 2 ABR incremental encoders 5 VDC,
or outputs or outputs
Sink Sink ±10 V 4 AB counters or
X67DO9332.L12 X67AI1233 4 up/down counters 24 VDC,
4 inputs - X67BC8513.L12
8 outputs 2x pulse width modulation,
Digital inputs Digital outputs 16-bit time measurement, X67BC8331 12 digital channels
- 2 A nominal output current
24 VDC 24 VDC Source Counting relative timestamp 8 digital channels configurable as inputs
Node number switch X67AI1323 configurable as inputs or outputs
X67DI1372 4 inputs or outputs 1 analog input, 0 to 20 mA,
8 inputs 12-bit 12-bit
X67DM1321.L12 Analog inputs
Source X67DC2322
16 inputs/outputs 0 to 20 or 4 to 20 mA X67AI1333 2 resolver inputs, X67BC7321-1
0.5 A nominal output current 4 inputs 2 digital inputs, 8 digital channels
Software filter 16-bit 2 digital outputs CAN I/O configurable as inputs
- -
Event counter
or outputs
Gate measurement Analog inputs X67AI4850
X67DO1332 Potentiometer 4 inputs
Digital outputs 8 outputs
displacement gauge 14-bit X67BC4321-1 X67BC4321.L08-1 X67BC4321.L12-10
- X67DM9321.L12 X67IF1121-1
24 VDC 2 A nominal output current
16 inputs/outputs
8 digital channels 16 digital channels 16 digital channels
Source Digital X67AI2744
1x RS232 or 1x RS485/RS422, configurable as inputs configurable as inputs configurable as inputs
inputs/outputs - 0.5 A nominal output current Analog inputs Communication 2 digital inputs, or outputs or outputs or outputs
Software filter 2 inputs 2 digital channels configurable
24 VDC Strain gauge 24-bit CANopen
Node number switch as inputs or outputs
Event counter X67BC4321-10 X67BC4321.L08-10
X67AO1223
Gate measurement Analog outputs 8 digital channels 16 digital channels
4 outputs
X67DM1321 X67DM1321.L08 ±10 V 12-bit
configurable as inputs configurable as inputs
8 inputs/outputs 16 inputs/outputs X67UM1352 or outputs or outputs
X67DM9331.L12
0.5 A nominal output current 0.5 A nominal output current X67AO1323 4 digital inputs, 24 VDC, sink
8 inputs/outputs Analog outputs
Software filter Software filter 2 A nominal output current 4 outputs Combination 2 digital outputs, 24 VDC, source
X67BC5321
Event counter Event counter Sofware filter
0 to 20 mA 12-bit 0.5/1 A nominal output current
8 digital channels
Gate measurement Gate measurement Node number switch
1 strain gauge DeviceNet configurable as inputs
- -
X67AM1223
Analog inputs/outputs or outputs
2 inputs/2 outputs
Digital 7XV108.50-51 X67DV1311.L12 ±10 V X67SM2436
12-bit
inputs/outputs 8 valves 16 inputs, sink, software filter 2 full bridges for controlling stepper motors X67BCD321.L12
24 VDC 16 outputs, source X67AM1323 2x3 inputs for ABR incremental encoder 16 digital channels
Analog inputs/outputs EtherNet/IP - -
configurable as inputs
7XV108.50-62 0.1 A nominal output current 2 inputs/2 outputs 24 to 38.5 VDC ±25%
X67DM9321 8 valves 0 to 20 mA 12-bit 3A or outputs
8 inputs/outputs (5 A peak)
0.5 A nominal output current X67BCJ321 X67BCJ321.L12
7XV116.50-51 X67AT1311
Software filter 8 digital channels 16 digital channels
16 valves 4 inputs
Node number switch X67SM4320 Modbus TCP/UDP configurable as inputs
-
configurable as inputs
Event counter 16-bit
4 full bridges for controlling stepper motors or outputs or outputs
Valve control 7XV116.50-62 Temperature PT100
Gate measurement Motor control 24 VDC ±25%
24 VDC 16 valves
resistance 1A
X67AT1322 X67BC6321 X67BC6321.L08 X67BC6321.L12
measurement (1.5 A peak)
8 digital channels 16 digital channels 16 digital channels
7XV124.50-51 4 inputs
24 valves
Profibus DP configurable as inputs configurable as inputs configurable as inputs
16-bit
X67DV1311.L08 KTY10-6, KTY84-130, X67MM2436 or outputs or outputs or outputs
16 inputs, sink, 7XV124.50-61 PT100 or PT1000 2 channels PWM output (H bridge)
Valve control 24 valves 2x3 inputs for ABR incremental encoder
- software filter X67BCE321.L12
24 VDC 16 outputs, source X67AT1402 24 to 38.5 VDC ±25% 16 digital channels
Temperature PROFINET RT - -
0.1 A nominal output current 7XV124.50-62 4 inputs 3A configurable as inputs
24 valves
thermocouple 16-bit (5 A peak) or outputs