You are on page 1of 3

PRODUCT

DATASHEET
LTCD NTK #61305 rev 1.0

LTCD NTK: Lambda to CAN


Part Number #61305

Basic Specifications
Inputs / Outputs
• 2 x NTK Lambda sensors (MoTeC #57007)
• Power supply voltage 11 V – 16 V
• Power supply current 110 mA typical plus
the sensor heater current (heater current is
typically 0.5 A – 1 A and up to 2 A on start-
up) MoTeC’s LTCD NTK (Lambda To CAN) is
the twin version of the LTC NTK (#61304). It
Communications monitors, controls and diagnoses two NTK
• 1 x CAN Lambda sensors, and transmits Lambda
readings on a CAN bus. When using dual LTCs
Physical
or a mix of singular and dual LTCs, up to 32
• Dimensions 38 x 26 x 23.5 mm excluding
Lambda sensors can be configured on a single
wiring looms and connectors
CAN bus to simultaneously monitor multiple
• Weight 100 grams Lambda sensors.
• 1 x 4 pin male DTM connector (Power/CAN)
• 2 x mating connectors for NTK Lambda Features
Sensors • Provides accurate Lambda measurement
• Maximum ambient temperature 100 °C even when exhaust gas temperature is
changing rapidly (heating or cooling)
Additional Information • Calibrated by the user for a particular
sensor using either the initial sensor factory
Compatibility
calibration or a free air calibration
• MoTeC ECU models: M84 M400, M600,
• Pre-configured to suit a single LTCD NTK
M800, M880, M1 Series
unit installation (see page 3 for more
• Data Loggers: CDL3, SDL, SDL3, ADL,
details)
ADL2, ADL3, ACL

PC Requirements
Software
• For multiple LTC NTK installations, LTC
• Windows XP or later
Manager software allows all LTC NTK units
• USB port
to be simultaneously managed and
Accessories diagnosed
• MoTeC UTC #61059 (Note: UTC is required, • The software is used to:
not compatible with MoTeC CAN cable) − configure and calibrate all LTC NTKs on
the CAN bus
User Manual and Software
− display readings and diagnostics
• The latest versions are available from
− configure CAN transmission addresses
www.motec.com/downloads

MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia
www.motec.com, Ph 61 3 9761 5050, Fax 61 3 9761 5051, support@motec.com.au
Product specifications are subject to change
PRODUCT
DATASHEET
LTCD NTK #61305 rev 1.0

Dimensions Connectors and Pinout


All dimensions in [mm]
Connector A and B
NTK sensor connectors
Mating connector: supplied on sensor
Pin No Wire Colour Description
1 Blue Heater +
2 Yellow Heater -
3 Orange Rc
4 Black Sensor 0V
5 N/C
6 Grey VS
7 White IP
8 Black Sensor 0V

Power/CAN Connector
DTM 4pin (M) (#68055)
Mating connector: DTM 4pin (F) #68054
Pin No Wire Colour Description
1 Black Battery –
2 Green CAN Lo
3 White CAN Hi
4 Red Battery +

MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia
www.motec.com, Ph 61 3 9761 5050, Fax 61 3 9761 5051, support@motec.com.au
PRODUCT
DATASHEET
LTCD NTK #61305 rev 1.0

Configuration
MoTeC LTCD NTKs come pre-configured to suit a single LTCD NTK unit installation. By default,
the initial factory sensor calibration is used and the following CAN addresses:

Sensor  CAN Address 
1  460 
2  461 

It is only necessary to use LTC Manager if installing multiple LTC NTK modules or if changes to
the default settings are required.
Wiring
To connect a single LTC NTK unit, the Power/CAN connector should be wired according to the
following table:
LTC NTK Pin  Battery ‐  CAN Lo  CAN Hi  Battery + 
1  2  3  4 
SDL & SDL3 (CAN 0)  35  36 
SDL3 (CAN 1)  29  30 
ADL2   73,75  74,76 
ADL3 (CAN 0)  73  74 
ADL3 (CAN 1)  75  76 
Ground  Power 12 V (see tip) 
ACL (CAN 0)  5  6 
ACL (CAN 1)  7  8 
M84  B24  B23 
M400/M600/M800  B24  B23 
M880  47  48 
Tip: To wire the LTC NTK to power connect either to the ignition switch for fast sensor start up
or connect to the fuel pump relay to prevent accidental battery drainage
CAN bus wiring
For information on wiring a CAN bus with several LTC NTKs and any number of other CAN
devices as in the example below, refer to the relevant device manual.
PC connection
The LTC NTK connects to the USB port on the PC via a MoTeC UTC (USB to CAN). The UTC is
plugged into a CAN connector wired into the CAN bus. More information in the LTC manual.

MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia
www.motec.com, Ph 61 3 9761 5050, Fax 61 3 9761 5051, support@motec.com.au

You might also like