DEPARTMENT QUARTERLY SAFETY AUDIT

HEALTH CLUB
Reception/ Sunbed/ Spray Tan/ Changing Room/ Pool/ Spa/ Sauna/ Steam/ Gym/ Pool Plant

Please list in this box any urgent concerns, which pose a risk to the health, safety or welfare of a person or the business, which
require immediate consideration. Escalate these to the GM with immediate effect.

Issue Identified Follow Up and Date of Rectification

Audit Completed by ______________________________ Date ________________

CP

For further guidance please refer to the following documents indicated in colour
HILTON HEALTH & SAFETY MANUAL HACCP MANUAL SECURITY MANUAL
HILTON LEISURE HEALTH & SAFETY MANUAL

N Date
General   Action Required
A Completed

SLIPS, TRIPS AND FALLS All areas in good repair


including walls, floors, ceilings and fittings.  

Wet floor signs in use whilst mopping is undertaken. Dry


mopping is a preference to avoid leaving floors wet.

Trip hazards removed, secured or highlighted with


appropriate signage.

Changes of level and staircases clearly highlighted, ✓


handrails where required and no defects.

All Team Members wearing suitable clothing and


footwear.

Cleanliness maintained in all areas and schedules


available where required.

Waste removed regularly.

All ACCIDENT INCIDENT REPORTING and near


misses documented and investigated as required.

WELFARE provision including operational toilets, ✓


stocked hand wash facilities and drinking water.

Adequate LIGHTING, ventilation and heating.

Good MANUAL HANDLING practices in place ✓

Safety and Security 2021


including storage, equipment and lifting techniques.

All Team Members trained.

WORKING AT HEIGHT tasks eliminated or


controlled where required.

Equipment in good order and checks completed (e.g.
kick stool, stepladders).

All equipment suitable for use.  DEFECT


REPORTING in place for electrical and non-electrical ✓
equipment and no defective equipment in use.

Good STORAGE practices in place including minimal


combustibles, away from ignition sources, with safe ✓
access and egress.

CHEMICALS & HAZARDOUS SUBSTANCES


Nominated and approved substances only.

Data sheets available.


Labelled and stored appropriately including flammables.

Adequate provision of FIRST AID equipment, in date


and fully stocked.

Trained Team Members available at all times.

Safety training up to date, including SAFE SYSTEMS


OF WORK (SSOW) as per training matrix.

Vulnerable Team Members assessed and relevant


controls in place e.g. YOUNG PERSONS,
PREGNANCY (including new mothers) and ✓
REDUCED CAPABILITIES (including those returning
from long term sick leave).

VISUAL DISPLAY UNITS (VDUs) users, assessed,


trained and relevant controls in place (where required).

N Date
Health Club Reception   Action Required
A Completed

CCTV operational, signed and covers all areas (If


permitted by local law).

Member information not openly displayed on computer


screens. ✓

Signing in/ out procedures completed. ✓


Appropriate signage as per local law (Health
Commitment Statement, Health Club Safety Code, ✓
PEEPs).

Health club secured from unauthorised access. ✓

Safety and Security 2021


Wet Leisure Supervision policy in place and evidence of
use (UK Only).

Team Members trained.

‘Health Club Cleaning & Maintenance Checklist’


completed including hourly club walk round, cleaning
schedules for all areas and equipment checklist.

Panic alarm for areas tested with control panel to ensure ✓


correct identification of location (note hotel response to
panic alarm activation).

No defective equipment in use.

Emergency Equipment Box available with foil blankets,


slippers, torches, fire evacuation jacket, and safety data
sheets.

Communication device to speak with hotel fire


coordinator.

PERSONAL PROTECTIVE EQUIPMENT (PPE)
available, clean and maintained, appropriate for task.
Including respiratory protective equipment (gas mask
with filters changed every 6 months).

Signage in place indicating use requirements.

Towel drop clearly signed and suitable container for


removal (consider manual handling effort). ✓

Decals on glass panels at two heights where required. ✓


ELECTRICAL equipment in good repair. No defective
equipment in use.

Date
Sunbed/ Spray Tan   NA Action Required
Completed

Sunbed user registration form completed and annual


sessions limited. No under 18 years. ✓

Sunbed serviced annually and internal daily checks


completed. ✓

Sunbed user safety signage displayed above token


machine.

Sanitising spray bottle or sanitiser wipes (clearly labeled)


and disposable towels provided. ✓

UV Eye protection issued at reception for sunbed users. x

Panic alarm operational, signed, tested and easily h


accessible. Team must be able to open door from
outside. NA
Suitable room with adequate ventilation and filtration
system.

Skins sensitivity test/ health questionnaire in use. No


Safety and Security 2021
under 16 years.

Beautician and guest wearing suitable PPE.

Wash hands before treatment.

Dispose of waste materials safely.

N Date
Changing Rooms   Action Required
A Completed

Hair dryer vents in place and free of lint. No defective


equipment in use.

No long trailing cables/ unable to reach water.

Interlock on swimming costume dryer. Automatic cut off


in operation and draining appropriately.

Cleanliness and repair of benches, walls, doors, ceiling,


ledges, vent grills, vanity units and toilets.

Floor surface clean and in good repair with no excess


water pooling.

Playpens checked monthly.

Lockers and doors in good repair and panels secure.

Lockers have a suitable locking mechanism and


disclaimer signs displayed.

All lockers checked and empty overnight.

SHARPS DISPOSAL Needle grabber and sharps box


available. Body fluid spillage kits available. Team
Members aware of location.

SSOW in place and trained to all Team Members.

LEGIONELLA water hygiene checks completed


including weekly flushing of low use outlets.

SHOWERHEAD CLEANING up to date.

Showers water temperature controlled by mixer.

Shower areas clean.

Shower glass doors in good repair.

‘Shower before entering pool hall’ and ‘Caution – floor


slippery when wet’ signage displayed.

Provision of sanitary towel disposal bins in the female


and disabled toilets.

BABY CHANGE UNITS and baby change seats, clean


and in good repair. Checked monthly (strap and buckle),
and no defective equipment in use.

Provision of nappy bins and proper waste disposal.


Safety and Security 2021
N Date
Swimming Pool/ Spa   Action Required
A Completed

Guests wearing appropriate clothing/ babies in suitable


swimming nappies. ✓

Appropriate signage displayed:

‘No diving, running, jumping and depth sign’ at each end


of the pool.

‘Panic alarm’ buttons signed.



‘Spa safety sign’ by spa bath.

‘Floor slippery when wet sign’ by spa bath, steps and


poolside showers.

‘Pool safety advice sign’ on entrance to pool hall.

Pool rescue equipment (throw bags and reach pole) wall


mounted.

One set at each end for large pools (over 100sqm).

Team Members trained in emergency pool response, and


suitable qualification certificates held on file. ✓

Good cleanliness and repair of:


Floors, walls, ceiling, ventilation grills, ductwork and
windows.

Pool channel, grating, scum line, skimmer baskets.


Skimmer lids secure.

Seating in pool/ spa bath and poolside.

Tiles for internal and external pool and spa in good


repair e.g. no sharp surfaces, broken tiles or water
pooling.

Internal checks completed for baby playpen.

Wet leisure capable of being locked off if 24-hour gym


in operation.

Outside pools secured at night or CCTV/ signage in


place to discourage access.

Pool hoist available, operational, statutory inspection up


to date.

Team Members trained.

Handrails and ladders secured for pool and spa. Step


anti-slip rubber in place. ✓

Sumps located 2 meter apart with anti- vortex covers.


Sump Vac alarm and cut off facilities serviced to ensure
working correctly.

Safety and Security 2021


Provision of over shoes and signage.

Underwater and overhead pool lights working. Some pools lights are not working
x
at the main pool and adult pool

Monthly microbiological samples satisfactory and


documented action plan for failed results. ✓

Daily pool and spa water tests completed.

Readings outside of acceptable parameters highlighted,


red circled and action taken recorded.

Photometer and TDS meter clean and in good working
order.

Photometer calibration records in date (annual).

Dilution, back washing, super chlorination completed as


required. ✓

N Date
Sauna/ Steam   Action Required
A Completed

Steam room/ Sauna safety signage displayed.

Age restriction signs

Sauna thermometer and timer operational.

Signed panic alarm operational and tested.

Fire boarding covers back wall and ceiling.

No evidence of charred or burnt wood on wall, ceiling


paneling or around guard.

Checked hourly for cleanliness and no combustibles


present.

Fresh water available to add to coals depending on sauna


type.

Sauna seating has no splinters or metal protrusions.

Sauna coals and metal thermostat guarded.

Steam room outlet guard fitted. Signage indicates the


location of the steam injector.

Seats cleaned regularly to remove excess body fat.

Safety and Security 2021


N Date
Gymnasium   Action Required
A Completed

Appropriate ‘Health Commitment Signage’ (UK Only),


x
PARQ or local alternative displayed.

Good cleanliness and repair: floors, walls, ceilings,


windowsills, skirting, water fountains, televisions, ✓
mirrors, and all gym equipment.

‘Health Club Cleaning & Maintenance Checklist’


completed including daily visual checks.

Gym equipment checklists completed weekly and


recorded. No defective equipment in use.

‘Instruction on use’ signs not removed, worn off or
covered.

Annual service contracts up to date.

Team Members providing advice and instruction have


suitable qualifications. ✓

Equipment positioned correctly (e.g. walkways and fire


routes kept clear, sufficient distance between equipment,
and not placed against glass windows). ✓
Any loose cables secured.

Signed stretching areas provided with mats and space for


warming up. ✓

Provision of sanitiser bottle and disposable towels or


disposable wipes. ✓

Provision of drinking water. ✓


Fitness balls are anti burst, used on soft surfaces, kept
out of sunlight and inflated to manufacturer guidance.

No damaged balls in use.

Weights signed, with suitable storage racking, not Need to remove the dumbbells
positioned directly against mirror. rack

Panic alarms tested as required for activation, audibility


and response.

Suitable signage displayed. x

Panic alarm to main hotel reception for 24-hour gym.

Spinning bike signage to entrance door and/ or on


individual bikes if moved (not moved by members).
x
Instructor re iterates safety rules before each class.

Annual service in place.

Safety and Security 2021


24-hour gym surveillance cameras linked to main hotel
reception (where permitted by local law).

Appropriate access control to 24-hour gym with deadbolt Only main door from the SPA
feature removed to prevent guests locking themselves in. x
have a cctv camera’s
24-hour gym signage displayed.

Panic alarm direct to reception operational and tested.

N Date
Pool Plant   Action Required
A Completed

All plant rooms locked.

PPE available, clean and maintained. Appropriate for


task including:

Wellington boots (different sizes), gauntlets, full-length


PVC apron, full-face visor.

Respiratory protective equipment (gas mask filters


changed every 6 months).

Signage in place indicating use requirements.

Running water at sink or wall-mounted eyewash station


provided. Sterile EYE WASH STATION in date, no
open bottles present.

Chlorine/ chemical day tank, associated pumps and


dosing lines in good condition.

Overflow bunding in good condition and empty.110%


capacity.

Injectors in good condition and plunged 3 times a day.

Foot valve cleaned weekly with hot water.

Pool balance tank inspected and cleaned 6 monthly.

Spa balance tank inspected and cleaned weekly.

CHEMICALS advice signage displayed on door


entrance.

Chemical safety data/ summary sheets displayed above


each product.

Containers and scoops colour coded and stored


separately.

PERMIT TO WORKS available and in use.

CONTRACTOR SAFETY procedures in place and


evidence of use.

Plant room clean, tidy, and free of combustibles. No


leaks evident.

Safety and Security 2021


CO2 detector/ indicator outside the plant room door and
tested quarterly (if required).

Panic alarm operational and signage displayed.

UV treatment is operational (where applicable).

Bulbs in date, and installed as per manufacturers


guidelines.

Emergency shut off buttons present/ signed where


required.

Plant room mechanical ventilation in place and


operational.

Team Members trained in pool plant operation.

Hotel crisis team trained in pool plant emergency


response.

Site Specific (Please list any unique risk assessment N Date


  Action Required
control measures to be checked) A Completed