"IBC2006E" is a spreadsheet program written in MS-Excel for the purpose of seismic loading analysis for

buildings and various nonbuilding structures, as well as architectural, mechanical, and electrical
components per the IBC 2006 and ASCE 7-05 Codes. Specifically, the total base seismic shear for
buildings and nonbuilding structures is calculated. For Multi-Level Buildings, the vertical distribution of
the total seismic shear is also determined, and a drift analysis can also be performed.. The seismic
restraint force for various components is also calculated.

This program is a workbook consisting of eleven (11) worksheets, described as follows:

Worksheet NameDescription

Doc - This documentation sheet

Single-Level Bldg. - Seismic base shear for single-level buildings

Multi-Level Bldg. - Seismic base shear and vertical shear distribution for multi-level buildings

Multi-Level Bldg. (Drift) - Seismic story drift analysis for multi-level buildings

Vert. Tank or Vessel - Seismic base shear and overturning moment for vertical tanks/vessels

Nonbldg. Struct. - Seismic base shear for nonbuilding structures

Arch. Components - Seismic forces for architectural components

M & E Components - Seismic forces for mechanical and electrical components

Maps for Ss - 2002 USGS maps for 0.2 sec. spectral acceleration with 2% P.E.

Maps for S1 - 2002 USGS maps for 1.0 sec. spectral acceleration with 2% P.E.

Maps for TL - ASCE 7-05 Code maps for Long-Period Transition Period

Program Assumptions and Limitations:

1. This program uses the IBC 2006 Code only to determine the Seismic Design Category, while IBC 2006
Code Section 1613.1 permits the Seismic Design Category to be determined by either IBC 2006 or ASCE
7-05. For all practical purposes, beyond determining the Seismic Design Category, the IBC 2006 Code
now defers to the ASCE 7-05 Code for seismic analysis and design.

2. This program incorporates the changes provided in Supplement No. 2 to the ASCE 7-05 Code.
3. For buildings, the program assumes the use of the equivalent lateral-force method for analysis, per
ASCE 7-05 Section 12.8. For nonbuilding structures, ASCE 7-05 Section 15.0 is followed. For
architectural, mechanical, and electrical components, ASCE 7-05 Section 13.0 which is followed. The
"simplified" method, per ASCE 7-05 Section 12.14 is not used in any of the calculation worksheets.

4. The program assumes "regular" buildings and structures, with plan and vertical irregularities not
being considered. Refer to ASCE 7-05 Section 12.3 for building configuration, and plan and vertical
irregularity criteria.

5. Worksheets for Multi-Level Buildings are applicable for buildings and structures up to 240 feet in
height, with up to 15 levels. (Story deflections are to be determined from separate elastic 2D or 3D
frame analysis.)

6. This program does not include the provisions for nonbuilding structures that are supported by other
structures as per ASCE 7-05 Section 15.3.

7. Worksheets calculate for "gross" seismic shear force, and do not reflect the use of any load factors.
Refer to ASCE 7-05 Section 12.4 for applicable loads factors for LRFD or strength design as well as ASD
analysis.

8. USGS 2002 maps for the short term 0.2 sec. spectral acceleration (SA) with 2% Probability of
Exceedance in 50 years, Ss, as well as the 1.0 sec. spectral acceleration (SA) with 2% Probability of
Exceedance in 50 years, S1, are included. These maps are the 2002 "color versions" of Figures 22-1 and
22-2 from ASCE 7-05. Peak gravitational acceleration, PGA, is what is experienced by a particle on the
ground. Response spectral acceleration, SA, is what is approximately experienced by a building, as
modeled by a particle on a massless vertical rod having the same natural period of vibration as the
building. The SA values shown in the USGS maps as well as the ASCE 7-05 Figures 22-1 through 22-14 are
expressed as a percentage of "g", the acceleration due to gravity. Their numerical values should be
divided by 100 to convert them into decimal form for use in the Code formulas and calculations. Note
that there are "exploded" maps of various portions of continental U.S. included as well. These can be
seen by scrolling down screen. (Note: while the USGS does have more current gridded design values for
Ss and S1 available at their web site, the user is cautioned in their use as they are NOT officially adopted
for use by the ASCE 7-05 Code. If their use would result in a lower Seismic Design Category and reduced
seismic loads, the user is advised to seek formal approval of their use by the owner and building official
if applicable.)

9. This program allows the user to select only site classes "A" through "E", since site class "F" requires
site-specific geotechnical investigation and dynamic site response analyses. These same requirements
also apply for site class "E", but only when Ss >= 1.25*g and S1 >= 0.5*g.

10. In the calculation worksheets, a "hyperlink" is provided to take the user directly to the USGS website
at:

http://earthquake.usgs.gov/research/hazmaps/
Once finished at the USGS website, the user should exit the website by pressing the [<-Back] button in
the top toolbar of the web browser to return to the particular program worksheet.

11. This program automatically selects the appropriate seismic response modifier, "R", once the type of
seismic resisting system has been selected/input by the user.

12. This program will automatically alert the user with a "warning message" when any applicable
limitations have been exceeded for the particular seismic resisting system selected.

13. This program contains numerous “comment boxes” which contain a wide variety of information
including explanations of input or output items, equations used, data tables, etc. (Note: presence of a
“comment box” is denoted by a “red triangle” in the upper right-hand corner of a cell. Merely move the
mouse pointer to the desired cell to view the contents of that particular "comment box".)

Cross Reference Index between IBC 2006 and ASCE 7-05 Codes

SubjectIBC 2006ASCE 7-05

Occupancy CategoryTable 1604.5Table 1-1

Seismic Importance FactorDefers to ASCE 7-05Table 11.5-1

Mapped 0.2 Second Period Spectral Acceleration, SsFigure 1613.5(1)Figure 22-1

Mapped 1.0 Second Period Spectral Acceleration, S1Figure 1613.5(2)Figure 22-2

Site ClassTable 1613.5.2Table 20.3-1

Acceleration-based Site Coefficient, FaTable 1613.5.3(1)Table 11.4-1

Velocity-based Site Coefficient, FvTable 1613.5.3(2)Table 11.4-2

Maximum Spectral Response Acceleration, SMSEqn. 16-37Eqn. 11.4-1

Maximum Spectral Response Acceleration, SM1Eqn. 16-38Eqn. 11.4-2

Design Spectral Response Acceleration, SDSEqn. 16-39Eqn. 11.4-3

Design Spectral Response Acceleration, SD1Eqn. 16-40Eqn. 11.4-4

Seismic Design Category Using SDS and Occupancy Cat.Table 1613.5.6(1)Table 11.6-1

Seismic Design Category Using SD1 and Occupancy Cat.Table 1613.5.6(2)Table 11.6-2

Building ConfigurationDefers to ASCE 7-05Section 12.3.2


Permitted Analytical ProceduresDefers to ASCE 7-05Table 12.6-1

Seismic Load Effects , E and EmDefers to ASCE 7-05Section 12.4

RedundancyDefers to ASCE 7-05Section 12.3.4

Deflection and Drift LimitsDefers to ASCE 7-05Section 12.12

Equivalent Lateral Force ProcedureDefers to ASCE 7-05Section 12.8

Seismic Force Resisting SystemsDefers to ASCE 7-05Section 12.2.1

Seismic Force Resisting System Coefficients and FactorsDefers to ASCE 7-05Table 12.2-1

Architectural, Mechanical, and Electrical ComponentsDefers to ASCE 7-05Section 13.0

Nonbuilding StructuresDefers to ASCE 7-05Section 15.0

Note: Per IBC 2006 Section 1613.1, the Seismic Design Category is permitted to be determined by either
the IBC

2006 or ASCE 7-05 Codes. For all practical purposes, beyond determining the Seismic Design Category,
the

IBC 2006 Code now defers to the ASCE 7-05 Code for seismic analysis and design