Identification System in M30 Housing

BIS C-60R-001-08P-PU-_ _
The simplest parallel read-only system for 8 bits

Function Technical Data

The BIS C-60R-001-08P... The stored information is Installation drawing BIS C-60R-001-08P-PU-_ _
is designed as a read-only made available on the
system. outputs as soon as the 95
code tag enters the active 78
Before a read operation
zone of the read head and

M30x1.5
can take place, the three
the data check is positive. L

surface
bytes on the code tag

active
starting with Address 0 Bending

Ø8.3
radius
must be pre-programmed.
>50 mm

Ø110
Programming example

Code tag Bit number User data Check data 13 5 LED data valid
Address 7 6 5 4 3 2 1 0 36

Clear zone
in metal
00 0 0 0 0 0 1 0 0 04 Hex For mounting, use the included
01 1 1 1 1 1 0 1 1 FB Hex ³32 M30x1.5 jam nuts!
02 1 1 1 1 1 0 1 1 FB Hex

In a read operation the For easy programming of Supply voltage DC 24 V +10/–20 %


first three bytes starting at the code tags a processor (incl. ripple)
Address 0 are read from with serial terminal and Current max. 300 mA with no load
the code tag. The first Balluff 007 protocol can Output current per output max. 50 mA
byte contains the user be used. Voltage drop ≤ 1.5 V
data. The next two bytes Leakage current ≤ 0.08 mA
BIS007RW software,
contain the check data as Operating temperature 0...+50 °C
which is available for
an inverted value of the Enclosure rating IP 67
download at no charge at
user data. These are used Tightening torque 20 Nm
www.balluff.de,
for data integrity and are Installation in steel unshielded
makes it very simple and
evaluated by the system. Housing material Nickel plated brass/PA
easy to program code
If the check is positive, PUR cable 05 = 5 m, 10 = 10 m,
tags.
the 8 bits of user data Length L = _ _ 20 = 20 m,
from the first byte are Note: The remaining bytes Conductor size 2 x 0.5 mm2 + 9 x 0.18 mm2
made available on the on the code tag can also
parallel port, with the be used for additional Interface information for BIS C-60R-001-08P
"data valid" (High) signal purposes with the corre-
active. sponding processors in Wire assignments Wire color
the BIS C family. Supply voltage +24 V DC WH
In case of "Error" or "No
0 V DC pal BU
code tag present" the Compatible code tags Shield Shield
"data valid" signal (Low) is include the BIS C-122, Output Output Bit 0 BN
inactive. BIS C-130, BIS C-117 and Output Bit 1 RD
No. 823 075 DE • Edition 0105; Specifications subject to change.

BIS C-128.
The integrated LED indi- Output Bit 2 OG
cates system status. Output Bit 3 YE
Output Bit 4 GN
Output Bit 5 BU
Output Bit 6 VT
Output Bit 7 GR
Data Valid BK
Read distances
Axial offset (mm) LED function display
Code tag type Read at read distance Output
distance 1 mm 3 mm 5 mm 7 mm LED Status "Data valid"
BIS C-122-04/L (∅10) 0...2.5 mm ±2 No code tag Off Low
BIS C-130-05/L (∅16 0...4.0 mm ±5 ±3 Code tag present On High
BIS C-117-05/A (∅30) 1...8.0 mm ±7 ±6 ±4 ±3 "Data check error" slowly flashing Low
BIS C-128-05/L (∅26) 0...12.0 mm ±10 ±10 ±9 ±9 Short circuit on output rapidly flashing Low

Balluff GmbH
Schurwaldstraße 9 Phone +49 (0) 71 58/1 73-0
73765 Neuhausen a.d.F. Telefax +49 (0) 71 58/50 10
Germany E-Mail: balluff@balluff.de