You are on page 1of 87
arses ey SITE DOCUMENT COVER SHEET lpetrofac (SS aoe teem. oie Ventr of Potrotae Sou East aia Pte Ld, Sipe Singapore Pe Land Samsung Engineering (Thana) Co, tt. DOCUMENT TITLE: Method Statement for FIRE WATER PIPE REPAIRING FOR DO2 ‘TOP No.: R1118111-ITDCO4-10-MST-10516 CONTR. Doc. No.: 2044-00000-C1-512579 R1118111, CLEAN FUEL PROJECT Date 12 Mar 2022 Ub-tea-22I Signature x Cree) Be euMENT STATOR aaneD DATE C1 -_ REVIEWED WITH NO COMMENTS DaAmenw tam | \b- -lerr) REVIEWED WITH COMMENTS AS NOTED. COMMENTS SHALL BE | C2 - CONSIDERED. REVISE AND. RESUBMIT THE DELIVERABLE FOR REVIEW. PROCEED WITH FABRICATION. (©3__ REJECTED DO NOT PROCEED WITH FABRICATION (Ch RECEIVED FORINFORMATION ONLY SCF - SUPPLIER CERTIFIED FINAL 'SSUE OF CERTIFIED FINAL DOCUMENT DOES NOT RELIEVE SUPPLIER OF RESPONSIBILITY OR LIABILITY UNDER THE 'CONTRACT/PURCHASE ORUER. Page Toft revotac Ey ca \, SITE mel Tharoi! Join Venture of etrotac South East Asia v og DOCUMENT ie id Soiper Singapore Pte. Li ond | Semsung Engineering (Rhaiand) Coy td. TOP No.: Rii18111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 INDEX LIST OF CONTENTS: ITEM PAGE 1. SCOPE 2 2. DEFINITIONS 2 3. REFERENCES 3 4. GENERAL Bi 5. ORGANIZATION CHART 5 6. ROLES AND RESPONSIBILITIES 6 7. MANPOWER 7 8. TOOLS AND EQUIPMENTS id 9. Quality Control and Quality Assurance Engineer 8 10. WORK METHODOLOGY 9 11, SSHE RERUIREMENTS 13 12. TRAFFIC CONTROL AND MANAGEMENT PLAN 17 13. ATTACHMENTS 18 ATTACHMENT 1: Material description SWANCOR 901Epoxy vinyl ester resin /tanastiaya ‘aq SWANCOR 901Epoxy vinyl ester resin ATTACHMENT 2: Material safety data sheet SWANCOR CHEMPULSE 001-P/ianansilayae7u amanlaaniiunaytaiq SWANCOR CHEMPULSE 001-P ATTACHMENT 3: Material description BUTANOX M-06/tanatvstiaua‘ae BUTANOX M-06 ATTACHMENT 4: Material safety data sheet BUTANOX M-06/tanastiayacuarnilaaad ‘ayaa BUTANOX M-06 ATTACHMENT 5: Material description P20 Powder Chopped Mat /ianarsiiayataq P20 Powder Chopped Mat ATTACHMENT 6; Material safety data sheet /ianansiiayasuarmlaanavastag 1 retromc © Ep uavunlaandiouas anssmusudourneaunassTusianviaduinds 1. SCOPE This method statement is made to enumerate the procedure in the fire water pipe repairing Work in the construction of clean fuel project at Siracha, Thailand tananstuaaumsvasutinimuaduaautusudauvaduimas tunsiaasotasans tdandoavara detrimiseinatnn, 2. DEFINITIONS Project Name + CLEAN FUEL PROJECT (CFP) Owner + Thai Oil Public Company Limited Unincorporated Joint Venture (UJV) Petrofac South East Asia Pte. Ltd. ‘Samsung Engineering (Thailand) Co., Ltd Salpem Singapore Pte. Ltd Subcontractor: ITALIAN-THAT DEVELOPMENT PUBLIC CO.,LIMITED Method Statement: Awritten document that explains the procedure in executing the work at a various stages and to assure that it comply with project specifications and detailed as per the latest IFC drawings. tanansivtevinduiaanatiuaautunseuiurntuduaaucroquaniatisiutan dv ilmtiariwuanasTasansuarmuaxduamuuuuviaylaaraa eT eae DOCUMENT pte, i Super Singapore Pe, i ‘Samsung Engineering (Thailand) Co, DOCUMENT TITLE : METHOD STATEMENT FIRE ‘TOP No.; R1118111-1TDCO4-10-MST-10516 WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 3. REFERENCES Project Specification ‘© R1118111-00000-CI-QcP-000002 QCP for Site preparation and Earth Works R1116010-TOSS-11-001 Thai Oil Engineer Standard — Site Preparation and Earth Works DEP 34.11.00.10-Gen S-0000-1670-102 Inspection and Test Plan Earth Work DEP 34.14,20.31-Gen DEP Specification ~ Drainage system and Primary treatment. facilities ‘ASTM D2487 Standard specification for Classification of soll for Engineering Purposes (unified soil classification system) ASTM 02488 Standard Practice for Description and Identification of Soils (Visual ~ ‘Manual procedure ) R1116010-0000-CI-SPC-0006 Civil works specification Vom P| al oon DOCUMENT ie, Uns, Super Singapore Pes Lid a Samsung Engineering (Thailand) Co, Ltd. TOP No.: Ri118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 4. GENERAL This Instruction defines all the work activities associated with the work to be perform by ITAL. TAN- THAT DEVELOPMENT PUBLIC CO.,, LIMITED. Throughout the fire water pipe repairing needed, Construction department of the ITD shall monitor the workmanship and compliance of the job was being undertaken as per project specification. Prior to the fire water pipe repairing work all related the section of work Ensure that fire water pipe repairing work is done with utmost regard to project safety and conforms to the project specifications lanarsadiudinmuafiansainisvisudsmia diterdiag nrstetaunudduuvionna shariaasts way ITD azasradauvinwsAlavavausuimatMaanndasmnvaufuniaud srdosedumsad uactfhutleruiarmuanastasenys rauvaeviasrudasviaduinds waver Uiniasfustudavadunde wove eos tatumsanadauTaudeuaue Wudevautuaru nasou anadauMatiuitarsudauvaduinas WT eaunnarUuArnuaanty uacisula enunfarimunnastasanys ‘This method of statement for work is based on project specification and standard drawing, which Covers the construction procedure of fire water pipe repairing. The requirement in the latest edition of Project Specification, Code & Standard Drawing Issued for Construction drawings shall form an. integral part ofthis procedure, tanaasdunaumsvinudsueT thilwWeniauavaslasomsuazinnnnasgudsasaunquiumaunsiaahooudauva unas orumdninauel uasunanass ud wsunumssudiauviadunds dawslaaraad iy Tdtumsriaais, dariwuadarmuanastasons Mudunfovasiuaautl Voc fe DocuMENT TOP No.: Rii18111-ITDC04-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 5. ORGANIZATION CHART Fire water pipe repairing rewotnc & Sy som Wrrcon a de tenmnerantc mh rn DOCUMENT Be, Ld. Saipem singapore Pt. Lt and $Scmsung Engnening(Falland) Coy (8 TOP No.: Ri118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE | WATER PIPE REPAIRING FOR Doz CONTR. Doc. No.: 2044-00000-CI-512579 6. ROLES AND RESPONSIBILITIES / winviuavavturavau Construction Manager shall be responsible for the over-all direction, coordination and control of all the construction activities attached and related to the fire water pipe repairing work Wamshaiaahsadaciuhavaudavamatauny, nasa usuuarnsAUAUBAIMANST msfiaatoviomuamifertiasuarieniasfusudaniadunas Engineer / Superintendent Sernn7ius1 Givil Engineer shall be responsible for the overall implementation and monitoring of all the activities in fire water pipe repairing work SennsTumactiludgufiariau tun rsd dur laumuuasmaanadaufhanramomuariierias fusruionviadunds The site engineer will be in possession of MSDSs and be fully conversant with the said MSDSs for all materials utilized in the application of the GRP lining. ‘Sensaauquiawy dasvheruturiarmuanas MSDS uasfinrmsousidns MSDS dyna radraidudernsu Aageiomue MaMunrsanory GRP ‘Site Supervisor (Bearer) / vows Site supervisor shall be directly involved in the planning and execution of the activities involve in the fire water pipe repairing work. He shal likewise ensure the implementation of construction plans. He shall prepare prior to the start of work, Safety Action Plan that must be implement and observed during the fire water pipe repairing work Wwnhouarsiavdd maw TauastunsnouAuMArAsA UdUuMsuasansUMAuashweN dauviadumdoonhouardaniutatunrnlgidenuunusuy aelavietouununsalgdaoruay hinu uausumaaranlaandy Hassan thlgiléuacdoinatuswhansviaw 6 gS —— Wrrcon Ae? sire eee DOCUMENT pte, Ltd. , Saipem Singapore Pte. Ltd. and ‘Samsung Engineering (Thailand) Co, Ltd. ‘TOP No.: Ri118111-1TDC04-10-MST-10516 | DocUMENT TITLE : METHOD STATEMENT FIRE at Senne | Waren pe aepazninc ron 002 ‘CONTR. Doc. Nox 2044-00000-CI-512579 Foreman / vayiheusu Foreman shall be responsible for the direct execution of work fire water pipe repairing according to the plan and shall directly control and give instruction to the working personnel. He is also responsible for the usage of proper tools / equipment, PPE, and housekeeping. Thmrhaunufarautumsagia nui ierniastauassAususudauvadumds aausuuar sasmuquuar twa uusthuriausty indetudiavaunrstaiatasiia / aulnsal PPE uarnisqua yanuaaratiimnvan ‘Safety Manager/Safety Supervisor / dian sev unlaaasiy / vouinow Safety Manager /Safety supervisor, prior to start of work, the safe work plan that must be implement and abide by during the fire water pipe repairing work amsduarnnlaanda / Wambo ued mar nnaaadudasanadourauduory, daseuiuns uae lamausumanuilaandedtusn hwo usudauviadunds 7. MANPOWER /ausu0 1 Bearer / qoouqunudehunrsusdisdomntnnaanat 1 Foreman / Wawthaust i Safety officer / whwihvlarunlaaasy § Flag Man / autvidquqrss 8. TOOLS AND EQUIPMENT/tafasiiouarquinsat 1 y@aiinsoivia FRP (Tauri, tuaru, then resin, thin hardener, viutuas) F RP materials (Glass fiber, Woven roving glass, Resin, Hardener, Thinne Dp) = vuSu$ 4” Gridding machine = ann'ly Electrical cable yaaulnsaivin FRP /FRP tool © nseanswne Abrasive paper 7 Ss ‘Samsung Engineering (Thailand) Co., Ltd. | Petrotac Soak

uyana Personal protective equipment (PPE) sagan Suction dump truck auinsaliaynefia (alseua) Hand tools (Spanner) tafaeqmin Vacuum ity Assurance Engineer / JeanseququAnimMuarnrnlsemuqniATN ‘Will make sure the method statement for the application of grp lining is being adhered to in all aspects. axvntvuutai Sémsdauvia GRP du ‘As asaunauituyneiu QA/QC will make the subcontractor aware of specifications and provide job order drawings before the application of the GRP lining repair work commences. QA/QC aevhieFuimanahonmuaiarmunuartousseuy Aoouiawdusudanuausiy GRP It will be the responsibility of the QA/QC to check the supply of materials that meet the required specification before the GRP lining work commences. /illuamufufiariaunas QA/QC Tunrsaszaaaunrs owriagvasomutiarnwuavirnwunniauiusudy GRP QN/QC will monitor the handling and distribution of the GRP materials in compliance with the site engineer's instructions and MSDSs./ QA/QC aeanaaaumsfamsuarmsuansrutag GRP musuushuasionnsuay Msps QA/QC will verify that the surface working area is in compliance with the GRP installation method statement. QA/QC axasraaaui uy uufluaauthtueuendoiainséiads GRP QA/QC will verify all members of the installation team are qualified and briefed of the procedures of the installation. QA/QC aesiasanaaau Yo udauynautuvudads dasiqnaniiuarnnutunaunrsiads QA/QC will inspect the GRP lining for visual deviation QA/QC ax asaaaau GRP sauanum ‘The QA/QC Engineer should check every layer of the application of grp 8 on i a Vrnoos se enemas foe DOCUMENT pte, Ltd. , Saipem Singapore Pte. Ltd. and ‘Samsung Engineering (Thailand) Co., Ltd. TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 lining. 4e2n5 QA/QC arsasrasaunrstasnusiantu GRP yniiu = Ensure the thickness of the application of grp lining is in compliance with the approved material submittal asyaaautuuitananamuraas uta gp Ulwlenunaruamsadstand eduawla '™ After the application of grp lining, there should be a water test. ‘waloann daw GRP liner @asfinismaaauth = The inspection request for the application of grp lining should be submitted every layer. twifimsasaaaau sudan GRP yndiy © QA/QC will check the GRP lining for integrity and areas, not in compliance will undergo remedial repairs to ensure specifications are met and comply with requirements. QA/QC axasvaiau squsian GRP Warnanysaluardud ‘Lilgidoua:tumsdauumuudtaiaty uutathasom aia munuacalglinudarmua ™ QA/QC will monitor the depth of the GRP lining and ensure the depth is in overall compliance with the method statement. QA/QC azaszaaau emumnuasthusiusian GRP uaevntvullahanumniiuaanndasty Ema 10.WORK METHODOLOGYnnsta4usi91u / Preparation 10.1.1 wauatiunausénrsviwiuuay JSEA wlauaayiia / Submit Method Statement & JSEA reviewed by UV and approved by TOP 10.1.2 vonumsualuayqnatumsvhow lausymuaridunnasemtvasudrunudoal nsalviuftntiasathotiatau / Apply the permit detailing the scope of work including all relevant tools and equipment’s 10.1.3 Shut-off or isolate the existing fire water line to reduce the pressure prior to commence the repairing work, Tovgauunintuviathmunaovifiagmaanussdunaudusudanuesy 10.1.4 duasdumautumsviytuuay JSEA Tunelgidoutwurieilgimounsn / Conduct a Tool box Talk to explain the work procedure and JSEA which ensure the participate person understood rerotac © Sy amr HIE. Joint Venture of Petrofac South East Asia eT ee — DOCUMENT pte Lad Sipe Singapore Pts Li. ond ‘Samsung Engineering (Thailand) Co,, Ltd. DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 ‘TOP No.: R1118111-ITDCO4-10-MST-10516 CONTR. Doc. No.: 2044-00000-CI-512579 10.1.5 The subcontractor will provide a clean and clear working surface free from pr otrusions, voids, and debris, dust, and moisture prior to GRP application. ABuwanehearHuaamsvae vam auariotaulneannarusiiuaansn dost wave eu uazanuduriaunrsaausy GRP 10.1.6 The subcontractor will provide the required lighting with sufficient illumination for the installation team to work unhindered. In addition, sufficient ventilation must be provided to clear fumes and noxious odors from the working area. sFunthowFomuasatov suihunfauuasatroluswadiuvudadaiia visu Tau'ifléefiawne uanainiidastatisimssnummaviiuewa Wlardaniuuacnduvifuiwaansiniudvien 10.1.7 The working area will be clear and free of all contaminants. Moisture must be eliminated from the working area for a successful GRP application. All hydroca rbon substances such as oils and lubricants will be removed for perfect adhesi ‘on. Any other surface impurities will also be removed. fluvvhonuasfiemaiarauuarinesndsvuiauionun siasritannuiu aanaanflurynenamativiimsdauvia GRP usvaunadiia Tauarslataseduauvionua tau thifuuavaneaadu avqniiinaan tlamsflaumudanysaluuy asanusnuuflurdua aeqnifinaansae 10.2 duaunrsaanviaduiwas / Fire water pipe repairing 10.2.1 anadausausauasth = vim sagas Epoxy stop leaked sa 10 uv thuyartua AtHrutunrselauiatl ~ wndefimstisia Alysia; Wavmssanmiaanifiatvsedinintuvia shin seduunavtaLsoavaevimsdan naévainiuvnuédtMuvonausoduvnmsdausiall Water leakage area inspection: - Use epoxy patching to stop the water leakage before applying the Fiber Glass Wrapping. - If epoxy patching cannot stop the water, a hole will be drilled at the leak location then use the hose and pump to lower the water level below the leak location after that to make it dry before repair. 10.2.2 vhanwataravuAsaniuarlauiauvialaunstimusasyiranuazara Clean and grind the above are to remove the top coat and surface of the pipe until the pipe glass fiber are expose 10 petromc © Sy eg Vrrcon A SITE oe cet DOCUMENT pte, Ltd. , Salpem Singapore Pte. Ltd. and Samsung Engineering (Thailand) Co, Ltd. TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE | WATER PIPE REPAIRING FOR DO2 CONTR, Doc. No.: 2044-00000-CI-512579 10.2.3 wautinen Resin waz Hardener santurevissyuarorucruusiiuasndnsaun thalWeidanadzuvignsiasuarivanvau Mix the resin and hardener as per the quantities specified in the recipe to maintain the right ration 10.2.4 ynthen Resin Au Hardener Mnantuudausiieviciasnsdantvivis Impregnate the above layer with the resin/hardener mixture 10.2.5 Wuluuravtatusnuaruvluvidteimtinen Resin Au Hardener Viwaufuudrtvsau via ainiiuvimsmiinen Resin fu Hardener VinanAuuaa tauvatvuAulanacte urfuarluarungauriuvims warn maanshaugnnds duu 4 Ym enudumauddel Apply glass fiber or woven roving glass and wrapping the full surface and impregnate the above layer with the resin/hardener mixture again and use the roller to prevent air bubbles following 4 step of work as following : 10.2.5.1 yaw 1 WutuuraAUTuay arwNtre 15 iuduias Wsauviusidicasmsaion Tou tiuuriadioy 4 duadudutuanudww 1 du (teuratdhen+teuiaHhe+te anutthinttaudathenttauds) sniiuviostvihewuvouarudiodracholiag 30 wit / first set Apply glass fiber and woven roving glass 15 centimeters width and wrapping the full surface by using glass fiber 4 layer and punctuate by woven roving glass 1 layer (glass fiber + resin coat + glass fiber + resin coat + woven + resin coat. + glass fiber + resin coat + glass fiber) then leave minimum 30 minute for the resin/hardener mixture dry out 10.2.5.2 yaw 2 Wutaurafutuaru anunte 25 isuduias tsauturvdasnrsdan Tautdtuuradiwiu 3 duadudutuaruduoy 2 du (Wuudatihenttuanutihentte witht tuanutihen+ tau) anduvielstvthenuveuacuiedathoiag 30 wit / second set Apply glass fiber and woven roving glass 25 centimeters width and wrapping the full surface by using glass fiber 3 layer and punctuate by woven roving glass 2 layer (glass fiber + resin coat + woven + resin coat + glass fiber + resin coat + woven + resin coat + glass fiber) then leave minimum 30 minute for the resin/hardener mixture dry out 10.2.5.3 yar 3 Wutuurafutuany anunty 35 iiuduias tsautuddeasnrsean Tootituurasrvew 3 duaduutueusrun 2 du (lawton ttuathen tte unatihen+tuanutthent tours) ainduriotstvthenuviouasudedaadhedag 30 wil / cv retrotc Sp acm sem. Wrong? SITE ee aro DOCUMENT pte, Ltd. , Saipem Singapore Pte. Ltd. and Samsung Engineering (Thalland) Co, Ltd. ‘TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 | CONTR. Doc. No.: 2044-00000-CI-512579 Third set Apply glass fiber and woven roving glass 35 centimeters width and wrapping the full surface by using glass fiber 3 layer and punctuate by woven roving glass 2 layer (glass fiber + resin coat + woven + resin coat + glass fiber + resin coat + woven + resin coat + glass fiber) then leave minimum 30 minute for the resin/hardener mixture dry out 10.2.5.4 yaw 4 Wutourafutuanu anuntne 40 wuduias twsauvuMeasnrsian Teotmtuurrtiuan 4 duaauvutumudiuen 1 du (tuuda+thent tours Hhenste anutthin+tauriatihen+ttauria) induristvthinuvouavudodationiag 60 wit / Fourth set Apply glass fiber and woven roving glass 40 centimeters width and wrapping the full surface by using glass fiber 4 layer and punctuate by woven roving glass 1 layer (glass fiber + resin coat + glass fiber + resin coat + woven + resin coat + glass fiber + resin coat + glass fiber) then leave minimum 60 minute for the resin/hardener mixture dry out 10.2.6 atatadumaumuaiad 10.2.5 vnammavaraviufauasm Top coat 618 Resin Snsau uadavio'ltvihuuvsathouan 6 aaTus After complete above 4 step will apply last layer is top coat by the resin/hardener mixture dry and leave minimum 6 hour for to complete 10.2.7 fasrutunrsdanusaiata uarvoseuznrsusiviuewauar fuArartatunrs amasaumanufmind iu yasomeauarqaviaume nuurtuersvntautaielasiia aseenwmsin (ci1snidlu) When complete and sufficiently cured the surface will be inspected for anomalies such as air pockets and exposed matting. Remedial work should be conducted using sanders if required. 10.2.8 lacnidunsuaaataviaimmasauusedutuviarfiatvuutad imum inate ‘uftzauvidanualuvia Perform the service test at perform pressure to ensure no leakage found at the repaired location 2 SITE Vrioon BP DOCUMENT | featurette sagt i ‘Samsung Engineering (Thailand) Co, Ltd. DOCUMENT TITLE : METHOD STATEMENT FIRE TOP No.: R1118111-ITDCO4-10-MST-10516 WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 11 SSHE RERUIREMENTS / unulgidnissuqamwauala ananlaaaio uavdouradou Approved Method Statement and Risk assessment for the application of grp lining should be brief, communicated, and implemented properly and available on the site at all times. 6 duastén rau otuayplauarnrnlsetuenandusdfumsdan GRP arsfavinisdaars wae shiflumsadramsnvanuarwiantinuvivneunaahsaaania General: During the execution of activities for the scope of work subcontractor shall comply with applicable SSHE requirements in line with UJV Project SSHE Plan (R1118111-00000-HS- PLN-00001) and OWNER’s SSHE procedure (R1116010-TOSS- 00-001) & other procedures and applicable Thai laws/regulations. umvia': mschidumsfanssud iuvauaanasouAtumnuariumnasavdaodguaenn aia Munarthawaiy ananlaansuuasdouradan Atsilomunmuawlasons SSHE CONSORTIUM (R1118111-00000-HS-PLN-00001) uavdiarwunctuaummariaunly ana daansiuuardowidan vasitruaoTasanrs (R1116010-TOSS-00-) 001) uaviiumaudu 9 Uhvulenaseisousiawomuuaengmanutve Permit to Work: Thai oil PTW procedure (MQOS-SPR-04) requirements shall be complied as applicable for the Brown field activities. Required personnel (Permit Applicant/Barer) shall be trained in line with PTW procedure. UJV PTW procedure (R1118111-00000-HS-PRO-00017) requirements shall be complied for activities in the green field. PTW holders shall be trained UJV. TuayQnatunrsvirs.U: Jas muadunaunrsvaayqnaviwiuuaslsendwinwlnsaaua (MQOS-SPR-04) aesfasulfidionantiar munduduflansauvirimuaitusturlatima (Brownfield) Aiivnnihviyaaygnavamuuagaruquer (Applicant / Barer) slag letumsausuaduMaunrs aayQnavwiu Personal Protective Equipment (P.P.E): All personnel for the task should wear the required PPE. In line with Project P.P.E procedure R1118111-00000-HS-PRO-00027. The minimum requirements: -Coverall / Long sleeve -Safety Helmet -Safety shoes “Safety Glasses -Hand proper gloves (As per the Project gloves policy) 3 DOCUMENT pte, Ltd. , Salpem Singapore Pte. Ltd. and Samsung Engineering (Thalland) Co., Ltd. [ ee SS v Rog SITE = | Tharod Joint Venture of Petrofac South East. ‘TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 All other additional P.P.E shall be worn as per the JSEA for the task e.g. Full body harness, chemical suit etc., Required reflective vest shall be worn by Riggers, Fire watch, Applicant, Permit Holder as per ‘the procedure. aulnsoiquasasarunianasiudauyana : ynaunrsavilgiaarnuiar muamsaritaaunsalduasasaranlaanduaauyana wud R1118111-00000-HS-PRO-00027 tiluathnoan : -yosiutel -mnnfisaa ~savwvinassia -wiuendsaia -qoflatata (oun nsouMrhmuatuuTenunrsaruqefiauastasens) ‘nvlildeaunsoleuasasamaanduduy arudseyty ISEA iu qunsalilasdunrsan yn ilasduannad soudaazviauusemusrumiomind dymiadusyy, didhsetolwl, quaayqnavne ,jeuay s1u muniarimua ‘SSHE induction and Trainings: Prior to commencement of the work activities, all personnel shall attend SSHE induction provided by UJV. Personnel shall be competent and trained for the task as per the project requirements e.g. working at heights, confined space, fire watch etc. mosflnausuadhawuly enmnlaandduavdouadantunrsvinew: raudaeduhanssunys vhouausTuynauardasiihunsauueduarthaunis armnlaanduuavdsurndantunrs vine tuain UJV uaenrsAlnausm Su 9 anaiarmua aud tdaquanal, HihseseM, msduacna daaadarfusiutag hmlvivasnuaaua TOP wianrsflnausumsuiuau 9 vasdFunnnuay eunnahoausiaoilugenuiudaiiuaus Plant and Equipment: All plant and equipment's shall be inspected and certified in line with UJV requirements for green field and TOP requirements for brown field and applicable Thai regulations. Valid inspection sticker shall be displayed. Operators shall be licensed, trained and qualified in line with Thai oil and applicable Thai regulations. Operators shall conduct daily check prior to commencement of the job activities. Machines shall be inspected by the mechanic on weekly basis. 14 retrotc © Sy age sum. SITE = Voices ey DOCUMENT te, Ld Spe singapore Pes i ond ‘Samsung Engineering (Thailand) Co, Ltd. TOP No.: R1118111-ITDC04-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 aunsal: aunsalfomunarsias etunrsanaaauuartusava ian muauastnuaaudua: UV Tnlaunsalaesias letutuayqnamstinausuuassiqniauaaanasastutiarmuanas' nuaaud UV uanlsina'ing giudayaumtassns aunsaliuarsaevnnrsanaaaulsesiunauvacy mavhoru, infasSnsnaaiasnnaaauTauthesnsnaadwiaudlevarady Daily Toolbox talks / Prestart safety meeting: Subcontractor supervisor shall conduct prestart safety talk with the work crew and PSST form to be filled. Supervision: All activities shall always be conducted under adequate supervision. SSHE advisor shall be present provide required advise on SSHE matters time to time. msm uAuaua: Aansanfsmunaeassrudumsnreteinrsquaathatfiuswayin SSHE advisor avdastvenuunhysruiueody arthawnis anmiaandg uavamnuadautumsvrouilu seuy ‘Security Management: During the execution of the activities, Contractor and Subcontractor shall comply with applicable Thai oil Security procedure requirements and Contractor Security Management plan (R1118111-00000-HS-PLN-00002). msdansaniniaaada: tusewinmsululansudtumnuarytummarwavciaoug aor darmuedunaumsinwrammlaaaduuad muaauauavunumsdamsarinlaansiuuas eBuiman (R1118111-00000-HS-PLN-00002). * Thai oil access control procedure shall be complied for personnel and equipment access, sas flémudunaunuqumsrinusraantsondulnuaausl * Portable equipment will be brought back to the survey team’s office / accommodation area during non-working hours. .afassla,qunsalazsiavtinau'alvia ino tladuqamsugdaor asvayiu ‘* Any point of time, Contractor and subcontractor personnel shall not access the areas which is not covered in the PTW. WiudFurmnuardsuumnarirludud ileseytitutuayagna yu Environmental/ Waste Management: Shall comply with UJV Environmental Management Plan and Waste Management Plan. misdamsdowiadan / ane: Wilf déermunumstansaswiadauuacunumsiansuaeuas uv. 15 7 ene Petrotac SITE a | ae int Venture of Ptrtac South East Ala : eo DOCUMENT ste, Ltd, Super Singopore Pt. Ld. ond ‘Samsung Engineering (Thailand) Co., Ltd. DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 ‘CONTR. Doc. No.: 2044-00000-CI-512579 ‘TOP No.: R1118111-ITDCO4-10-MST-10516 All waste shall be segregated and disposed as per the project waste management procedure. auevfominargnuunuarnaamunsuaunsianimuaruastasenys keep all work areas under tight housekeeping requirements at all times. It will be ensured that housekeeping is maintained throughout the day. Fiuvvnnrusian filionsniafrmuanrsquavhanuaamadratiusmnaania uavdaotuta ‘ethfimsquavnaniacaanaan * __ All debris and scrap material shall be kept away from the work area. ler Taquavuaevionuaaviaoiulsieaniudyon . Containers shall be provided by Contractor for the collection and separation of waste /refuse arising out this activity. ABuunascactatvimuusawiumsauTUUALUENEE © Garbage and other debris will be disposed of at frequent and regular intervals. untuaremuurdu 9 avgnrivaativaiiaua Incident and Emergency Management: If any incident/ Near misses happened, shall be reported immediately to UJV. Proper incident investigation will be conducted. mstamsaqidnrsnivaaiiaduasiuuastuqaniau: mnsiuamsalta 9 edu / via aldmsnivinaiaduanuazsasnunwialis WV Yui uavvnasaauaruarana, If any emergency situation arises, Project Emergency Response plan requirements shall be complied. windimamsalqnaunduasciavugidmuunutomaumamsalgnsunastassns Welfare: Adequate rest area, drinking water and toilet facilities will be provided for the personnel. aan: fivluvivinciauinowa théuuariavamnawiuningw ‘Work in Brownfield designated areas restrict certain items such as mentioned below from being brought into the refinery. msvnwutudluddirawualiuastudiiora Brownfield nums anvathsuiuvinanfostuaravanhuahtsondy * Lighters or matches / ‘Wudauta'aifia'wl ‘* Mobile phones / Tusewvifiagia + Weapons / arysynuitin 16 : reverse © Ey ace EE Vicon Mee sive aprinn ran se DOCUMENT ite Ltd. Saipem Singapore Pte. Li. and Exmsung Engineering (Matiand) Coy Ud, TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE __] WATER PIPE REPAIRING FOR DO2 CONTR. Doc, No.: 2044-00000-CI-512579 12 TRAFFIC CONTROL AND MANAGEMENT PLAN /UNUNTSAIUAUUALNS fanisn13a31495 + __Interms of traffic control, vehicles will be prohibited from reversing unattended into any construction or work area. Vehicles and plant will enter and exit these areas in the forward direction, as far as possible. In addition, will ensure that all heavy goods vehicles are equipped with audible reversing alarms. : Twat maanseququmsana wa MinuwmusauMfula Lifiauquainltuiud faatovtanuyvnouta 4 euynmuuasietasdnsastinuavaansinviuvinardtuidusame 169 wanarnfiaeasaaautvuitannumnusussynaud minvionnadih vacua + __ Flagmen and clear signs will be provided where necessary. The signs will be fixed safely and securely to ensure that they do not become detached or dislocated and will be visible and comprehensible by all. ...Company) ... shall carry out maintenance checks to clean and re-secure signs, as required. arsiactoussuudtvaquqnouariladausasdalviunclaaniuatvultanarlinaaaan uaenauadsaguasiuuacitnta ...(ui¥M)... wiaavMsANaAAaUL AINE YAN UAEATA uavdnihotviudhihunanianaqnaan * _ Appropriate supervision will be provided by ... (Company)... to control the flow of traffic when machinery requires crossing roads. ...(u31¥M)... s¥sfaariWuquamuRumstna aaymaaAnaflamfasinsdantwauulvivanean * Liaison with the Thailand Traffic Police, the UJV and any other authorities will occur prior to the movement of any abnormal loads. msfiasiausvatunudushsaanastng WV uaeniunudu 9 faurassinsiasaudhudonasvhhminwarwafinnatual * Access to commercial and residential properties will be maintained and speed limits will be established and enforced over all construction traffic routes. msauthurinudde Auvivimsanasnnuduuariyauarimnenudhmuviinwua uasiedulatuyndume maanastumsriaat + Ambulances and fire services will be consulted regarding road diversions. Road diversions will not increase the response time of these services to local communities. sOWETINAUALIAgUWALIESANTHAUMaLiND adusvaLAIMsauMoUdemmuisaly msthuwnia * Access to residential and commercial properties will be maintained. mstiauui>unas yuruUuaMadarduaedosiasmernmsmstiag * If road closures are required, diversions will be planned and communicated to UJV (including emergency services and public transport providers if public access roads are affected), operators within the area and/or affected communities and will be properly sign- posted. Crossing for pedestrians and animals will be provided to avoid the need for a diversion. winsnuflusiasfinsfaquuaesinsreunuuardaansfu UV dedumeriiue (sto usr sQnLauUALH LIM suUdIAErSALMNAMUUATE ON FURANSMU) HdufieUMMULTH sluvluay / iow etunansenuuavaysiagudadauathugneias Jatvsmoduahwiuau Guvhuardariflandénidusanusaamstaaumariius * _ No diversion will be permitted that prevents a public transport service from continuing or requires a diversion of more than 1km for vehicles or a diversion of more v7 rerrotac & Sj age sem. aos Ma? SITE a eee DOCUMENT pte, Ltd. , Saipem Singapore Pte. Ltd. and Samsung Engineering (Thailand) Co., Ltd. ‘TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE _ WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 than 500m for pedestrians or livestock. ax‘LiayqnativinwifussTananh 1 nu. tuned AnuMuUsMsauasssAUeAdlatiias weamouiusMeManANh 500 wu. dwduauntae, aoiiuoun + Re-Fueling will be minimized during transportation of construction materials and personnel, aesasaansmaduthalusewtomsuudsiaqiaadauarausy * Speed limit not exceeding 20 km/hr. in construction area, 30 km/hr. in the middle area and outer space area 40 km/hr. Drivers shall observe and comply with all relevant traffic regulations including speed limits in Thailand and the local area traffic law for record Snfiaarfybiiu 20 nu. / wu. tufiuviriaatns, 30 nw. / a. Tufludidunarouavduviduuan 40 nu. / uu., Hifudsiaougdduuarugudmunganasiieniaosviowuanutioms ata anuchonululseinatnauazngyanuanastuiud 13 ATTACHMENT (tansnsuuu) ATTACHMENT 1: Material description SWANCOR 901Epoxy vinyl ester resin /wanans tlayatan SWANCOR 901Epoxy vinyl ester resin ATTACHMENT 2: Material safety data sheet SWANCOR CHEMPULSE 001-P/tanans aiayaduaniniaaaduuasiag SWANCOR CHEMPULSE 001-P ATTACHMENT 3: Material description BUTANOX M-06/tananstiayatan BUTANOX M-06 ATTACHMENT 4: Material safety data sheet BUTANOX M-06/tananstiayash war aansiuuastag BUTANOX M-06 ATTACHMENT 5: Material description P20 Powder Chopped Mat /tananstiayaTaa P20 Powder Chopped Mat ATTACHMENT 6: Material safety data sheet /lanarsiiayasnunnmlaanduuasiag ATTACHMENT 7 : Drawing / uuuniaate ATTACHMENT 8: JSEA for file water pipe repairing / mstianevcruamlaanduuay, wansenududouasanuavoiudauviaduinds 18 Vrver OF mone SS aoe om one Joint Venture of Petrofac South East Asia DOCUMENT pte, Ltd. , Saipem Singapore Pte. Ltd. and Samsung Engineering (Thalland) Co,, Ltd. DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 ‘TOP No.: R1118111-ITDC04-10-MST-10516 CONTR. Doc. No.: 2044-00000-CI-512579 ATTACHMENT 1: Material description SWANCOR 901Epoxy vinyl ester resin /tanars sdayatiaq SWANCOR 901Epoxy vinyl ester resin SWANCOR 901 EPOXY VINYL ESTER RESIN Product Deseription 'SWANCOR 901 Isa Biphena A type epony vey eter rain. proves excobent coraeion resitanee to 2 broad range of ‘genie and organic acts, alias, ovfcing chemicals ang elt foliions ete ao proves very good mechencal strength sh as tensa lesa while ncrpraea with envoeamart ‘5128s ber, carbon fe or Kev fer et, SWANCOR 90% ‘= desgned 10 prowte superar toughness wih excelent aque Fessance due to igh heat ioriontmperatre Applications + Chemical storage tans, pes, ume got desuting systems (FD), scrubbers, ucts Corson resistant fooeng while ncorported_wih sogregaies. “plea clear casting Property essurement | Testbahod fenaleSvangh (gs)_| 1,000-15,000 | ASTM 0638 ferale Mooiue| ars1 | ASTIDESE 10% fersie Henge 30-80 | ASTwoase oul Songih (gs) | 18000-22000 |_ASTMDTSO. ena Modube aes4 | ASTMDTSO 10% ps) Noume shrinkage 0 Tee0 | asrwozses Hest Ditoreon| “06-112 | ASTM DEB Temperature (CF 252259 acoiMaranees| 35-13 | ASTDISS * Care concon for POT 24 Pure areamiemperatee hen ore a 18°. Hoat resistance of SWANCOR 901 mine twtr eter aya rood vores ta pre wea. Propety [NOS 1555] Testng | SWANCORSGT “Aarne use for yet ana boa, aprove by ONV ant ‘hie fempeatie 0] Lariate oye Reps Measurement rate 2000 | a5 72.000 Febraton Matos ‘9500 > ‘3500 + Candesasy apie byhand pup annsng, 849, a bution resin tanser molang (RTM) and arent 7.00 wind reaie = 74 + Canbeused npohma cone casing becus wa + Can comply win US FDA rguston 24 CFR 1772440 IO ps) 3 theres propery emulates an aed 2 2 ‘Typical properties of igi rein Prourar | io000 R000 Prope ve ah 28.000 Dopearnes Grsrenverigas fos) 0 Sold Content sSoni 000 esos 0" 0 1.108 3200 ‘poate Gov forscoge oar or “os Got in 16-25 oats 1 Se ices rises eae Pe i es = Moasurment were obaned unger 25°. = surss-copmaase, soe 22 excobat 0 apt, 100% OMA 0 Spt, Andonox LER: 1 one exe. Const aooraing to NBS PS 1888 “Laminate conertion allows: VIMIMIMRMIMRM, fe enter 39-40% hekoese 6m, ‘uty Prot wt InTime Senses and nmvation SWANCOR IND. CO., LTD. NO. INDUSTRY SOUTH 6 ROAD. 54066 NANTOU Cr, TAIWAN TEL #06 49-2065400 FAX Gob-0-2251604 wancor@vareer com Document Code: NT26-127- 1p Ieeva Dat: August 2008 SWANCOR 901 EPOXY VINYL ESTER RESIN ‘ypleal gel tne of SWANCOR. Temgeratre | Chemoat ara | 0-00 ed by MEKPIG0OaIOWA wc Yee | 1e0% | s50m | 120m oot | o4mn | oor | oan = weKP | 150% [1.20% | 120% Be [ess eet % exe | 1.20% | 100% | 1.00% | 04am | 020% | 030% mn os | o0% | 000% ued by SPO wc Fe Team | 180m | am 20s | 010% | oos% Ps PO 150% | 125% | +.00% oss | o10% | 005% re PO 150% | 105% | 1.00% a 012% | 008% | ooe Consent hndenox LGR, Coe 6, DMA: 100% * Conceneabon: BPO: 9%, DMA 00% Norice muse 4, MSWANCOR 91 bind win cobalt promotes she ie wil be shortenes. Promotes SWANCOR 901 must be ed within tee months ‘Te gel tere of SWANCOR 901 le atected primary by tay concenraton and temperature. The veratons of catalyst hunsiy, pgment, ers ana ober sadaves. 1 caracterises wah a smal quantity resin before proceeding fer buk poducton 'SWANCOR 904 contains organic sohent (styrene). Keep may on hest, spans and amos 'SWANCOR 901 ' @ poly reecbe chemical. Pease lore tn dak and keep away om heat and diet sunshine Containers, not comple erpies must be cored leisy er use MATERIAL SAFETY AND HANDLING INFORMATION ‘san conTACT “Through wash exposed area wth soap and water immedi Remove contamraed ching. Lander cotaminated coting EE CONTACT Fan wih lange aout of water nmeiaey and continuously for 20 mutes, fing upper and lower Is occasonaly Get redial stern Do not infuce variing. Keep person warm, que and get Imesicalatenton.Aspeaton of material to he ngs ca cause ‘chemical pneumonitis when can be ata INHALATION: Itc, remove india to fash af esting sek aminster oxygen beating N38 stopped, Qve ea ‘espraton Keep person warm, que, and get medial atente, PERSONAL PROTECTION: 1 ot breathe vapors. High concentaton of vapor can be hazardous. Koop ou of sewors.Elmint all sources of aren In Welty lor reeased vapor to avo re or exposion. For lage sls, war pubke of downwind explosen hazard. Check ‘a wih explosen meter before ye-enterg are. Ground and Trond al conainre and Reding equent RESIN STORAGE ep away trom inition sources: ames, pt igs, cra sparks, and sparking tos NO SMOKING Do nat ore in det night Sore sepersta om oxdang mates, paride, end meal sas Keep container closed when not nus. To ensure maxim stably and mainian optimum resin propre, resins howl be sored in closed containers at lepers teow BS'CITPR). Copper or copper conaning aloys snould be ode 98 containers ‘sPuis Eliminate a gniton sources (res, fares, etidng pi ghs ‘lecrcal apart), Persona ot wearing protecve equipment ‘should be excuse fro aa of spl ut clean-up nas teen Completed. Siop spi at source, dke are of spi fo prevent ‘spreading, pup iu to sahage tank. Remaining aud may te ‘wien up on sand, 2a, earn or absorsent or ater absorbent Waste DISPOSAL estoy by Inu incineration in accordance wih applabie repulaton. Coniamnated absorbent souls be dsposed scence 1 government egulcons. PACKAGE Standard packing i 200 stl tum, ‘Qualty Products wth nTime Service and Innovation no. {9 NDUSTRY SOUTH 6 ROAD, S4066 NANTOUCITY, TAIWAN, SWANCOR IND. CO., LTD. wancor@ievareer com 22 Document Code: NT26.127- Issue Date: August 2008 a Wrcron a SITE ere oe DOCUMENT pte, Ltd. , Saipem Singapore Pte. Ltd. ‘Samsung Engineering (Thailand) ct DOCUMENT TITLE : METHOD STATEMENT FIRE | WATER PIPE REPAIRING FOR DO2 ATTACHMENT 2: Material safety data sheet SWANCOR CHEMPULSE 001-P/tanas siayasiuaranaaastanastaq SWANCOR CHEMPULSE 001-P SRE MATERIAL SAFETY DATA SHEET tse noecaey Product Name: — SWANCOR CHEMPULSE 901-P 1. Chemical and Manufacturer information [Chemical Name : SWANCOR CHEMPULSE $01-P [Other Name : Epoxy Viny Ester Resin [Suppliers details: SWANCOR HIGHPOLYMER CO.,LTD. INO. SINOUSTRY SOUTH 6 ROAD, NAN-ANG INDUSTRIAL PARK, NAN-TOU CITY, TAIWAN 54066 R.O.C [Tet +006 49 2255420 [Suppers details : SWANCOR id) SON, BAD, [PLO 212, Runbia 5,Kawesan Perndustian Tanjung Langsat 81700 Pasir Gudang, Johor, Malaysia, [ret #607 255 6608. [Emergency telephone fadE-mall [TAIWAN : 1886 49 255420) +886 49 2251634” swancon@ewancor com tw [Emergency ielephone/faxE-mall_ [MALAYSIA : +60-7.2556505/+60-7-2557862/johor@swancor oon [Suggested Using and Restiion | NA. 2. Hazards Identification Flammable bquds : Category 3, Aaute toric : Category 5 ‘Skin ition: Catogory 2, Eye irtation : Category 2A, Hazardous chemicals | Germ oell mutagenicity : Category 2, cassiicaton Carcinogencty : Category 2, Reproductive tox : Catogory 2, ‘Spectic target organ systerc toxicity - singe exposure : Category 3, ‘Spectc target organ systemic towcty- repeated expasure: Category 1, ‘eat aquatic hazards : Catogory 3. Hazard symbal ~ _ OOo ‘Warnings : DANGER 1225 [Flammable quid and vapor 203 [May be harmful ewatlowed Hers [Causes tn tation 1519 [Causes serious eye tation 141 [Suspected of causing genet defects 1951 [Suspected ofcaunng cme Ho6t [Suspected of damaging fertity othe unborn cid 1536 [May cause respiratory intaton 1572 [Causes damage to organs though prolonged or repeated exposure ee Hazard statements) TO Sear 2021.10.01 BEE MB - MTB HATA Date Page: 4/7 Version 0 Quality Products with In-Time Service and Innovation MATERIAL SAFETY DATA SHEET Gren Emery &Emironmena roto & ay Product Name: — SWANCOR CHEMPULSE 901-P Keep Sway Wor fest Pot surface spars, open fames and Ofer non sources INosolong 7238 _|Keop container tohty cased 1240 |Grounafbond container and recaiving euipment 261 __|Use explosion roo elecrcatnentiatng/ightingintinsicaly safe equpment. 242 __|Use cay non-sparking cos P24 [Take precautionary measures agains! sac discharge. 280 __|Wear protective glovestrotectve clthinafayeprcteciontae protecion Precautonary 264 [Wash throughly ater handling statements) Preventon ||" 291 [Obtain spacial insructone before use 210 202 _|Donothande unt a safety precautons have been ead and undersioad 261 [Use personal protective equipment as required 261 [Avoid breathing ausiume/gasimstvaporsispray P271 [Use ony oudoors oF na wel-veniatd area, 260 [Donat breathe dusiRanelgasimstvaporispray. 270 |Oornot eat dik or smoke when using his product 273 [Avoid lease to the envionment rasa [EON SKIN (@ fait, Take of nmediataly al contaminated Gating, Rin) P903+P961+P353 | SiaN wih water or shower] Pa7O+P27@ __|Incase offre: Use o extinguish P3i2 [Cal @ POISON CENTER or dato you feel ure. 'Pa02eP3s2 | IF ON SKIN wash wt plenty of ater P21 Speci treatment (soe on tis abe). Precautionary P332+P313 [IF SKIN rrtaton occurs: Gat medical advesfatienion See P9362 [Take off contaminated clothing and wash it before reuse. IF TW EYES. Rinse cauiously wih water Tor several rites Remove) PSOS+PSS1#° 392 |coniactenses if present and easy to do - continue tring PS37+PS13 IF eye ation persists: Get medical acvoeaterion PS08+PS13 IF exposed or concemed: Get medical adveslatention P304+P340 [IF INHALED: Remove person to fresh ar and keep confortable or breathing | Pave (Get medical savcalatention you foe unwel PAGS=P235 [Strain a wel-venlated place Keep cool Precautionary statements) Storage Go Store locked up, 'Pa0a+P233 [Store ina wel-venblated place. Keep container bhi Closed. — Beeson zo2t001 page: yyy RAKES = RTO SLATS - IRIE] Veen: gq Cualty Product with in-Time Servcw and Innovation MATERIAL SAFETY DATA SHEET Gren Energy & Emroomenal Pen & Sty Product Name: — SWANCOR CHEMPULSE 901-P Precautonary statements) Disposal 501 [Dispose of contns/container in accordance wih cal regulations. Ober nazar NA. ‘3. Composition on ingredients Hazardous pred is percertage ASN [emia roneros 5 ssopropyaeredoheel elcome rection rocut wth ‘chloe 2.5 enouprenare, som 10125: Stable Chemica reacton presume nyt and methane od sere = Woon repeated Gremical 4. First-aid measures nelson Weed eve ride 0 Fes a bveatng RG. aarinalar oven. W eatin fra opp. gue ata rensason Kea persan wary uk nde mia stron Femecvoumenin [SG SE PEO wa eed ew Hap 9 wale, Rena SSS [eter By cri “Ph rye oyun waa mest 3 OTOSa TOR TAG 9 lowers occasional. Get rei ateon Ingesin Do natncue vorsing Koo persn vain, aS and gH TOG UGTA AAI TTA] isthe ge can cae choca poeumone wc ca ea [Because rept sbsorpbon ray cos ough ings repaid an cause ofiovicwfec. edooion joe omptam an Ham taro cen wrsing ons stu Brads by a ang pylcanfivape kperrned ape nor aye jendotracheal and/or exophageal control. Danger from lung aspiration must be weighed against toxicity when| ete Sonaisengemuiyng te snacr No Spooks andae Suppor cre Teahet based on noon Sno ghyaclan nmapene fo reason fe pata 5. Fire-fighting measures water og or Se sry, carbon ote, diy cherical foam Water fa, pled ory maybe vod 0 Sutase erating flanker fre exingustments Gane purpose aytete eas incudng AFF ype) or peta ae media refered aval. Achat essa foams (ATC ype) may funton Oo rt ise Set water steam, [straight o direct water. Stream may not be effective to extinguish fe. [May form toxic materials: carbon dioxide and carbon menoxie, various hydrocarbons [The azar might lencounter wile (extinguishing Keep poole away. late fre area and deny unecessary erty. Baring luca ay be moved by Rating hat water o protect personel and minimize property damage Water og, apped gently maybe used as huanet fre extrgushmerts. Eiminate rion sures. Stay upwind Kea out ow reas where gases Pra |(fumes) can accumulate, Do not use direct water stream. May spread fire. Weter may not be effective in| exingushing fe, Move contr om fe ara tise possi wnt hazard [Seca equipment tore ear postve-pessue seltcataines beating apparatus (SCBA) and protacve fe fohing doting loter includes re foning heme, coat, parts, bots, ard gloves. poecveequpment sro vale or a usa, Sgt re rm a protected locaton ste distance 6. Accidental release measures : Do not beat vapors. Vapor explosion Razors, Koop ut of severe Elmina al sowaes of ion] leersona!grecasions MCN Of pil relased vapor ava reo epson. Fer large spl, war ple of downed explosion Preasions —lrazard. Check area with emploson meter before reerteing area Ground and bond al cosines and landing expen. [Forge spi, evacuate upwind of spils and contain wth dike Parca extinguishment [Environmental [Pump with exolosion-proofequpment Hfavalable use foam to smother and suppress. Remove reslual with ot soapy water. IMettods for Gearing up_|Resitval can be removed with solvent. Solvents are not recommended for cleanup unless the recommended lexposure quide-ines and safe handing practice for the specie solvent are folowed. Consult appropriate] solvent MSDS for handing infomation and exposure guidesnes, —_ nr 2021.10.01 BRBL - MBA - MABE HRTF) Date Page: 3/7 Version ro ‘Quality Products with In-Time Service and Innovation SRE MATERIAL SAFETY DATA SHEET es merase eae! Product Name: —SWANCOR CHEMPULSE 901-P 7. Handling and Storage [Avi inhalation and contac wih yes, si, and cling, Wash Tanda haughy ae handing and bat] eating or crinkng. Remove and wash contaminated clothing belere reuse. Use wih adequate ventilation [Ground and tond containers when rarstering the material to prevent sale eecncty spark whch could lait the vacor. Use spark prof tols and explosion-soot equipment. Consult your supple cr promotes land catalysts or atonal irsructons on proper mang and usoge HHensing Empty conianers may retain product residue (quid andor vepoe). Do not pressutze, ik wed, braze | [cider cil, grind, or expose these contsiners to heet, fame, sparks, sate elect, oF other sources af lanton asthe conainer may explode and may cause injury or death. Empty cums shad be consletey| cranes end propery bunged. Empty hums shoud be prompt retumed o @ drum e-conitoner or propery \asposes Keep away fom inion sources ames, pit igh, leccal sparta, and sparing tool NO WOKING [Do not store in direct sunight. Store seperate fron axing mater, peroxides, and metal sats. Keep storage |cortaine ctsed when notin use. To ensure maximum stably and maintain optimum resin properties, resis shoud be stored in closed containers a temperatures below 75 degrees F (25 degrees C), Copper or copper |ortaining alloys stout be avoided as containers &. Exposure controls Hazardous cae Testing basis Type Standard Value Remarks [Fime Weignted ae {contro Parameters erage styrene ~ [short-term = a [exposure Limit ti Iceiing Hazardous [Botogical monitoring) Bilogcal lit vnping te eae Testing basis hon ‘Sampling T Bictogical Exposure, styrene ae ncices fg foe le a boca ae 'MANDELIC ACID z 00mgiNs) [Respiratory protection ln the case of vapour formation use a respirator wth an approved fier. Hand protection |The sutsity fora specie wrksace shoud be discussed withthe procucers of the protective gloves [Personal protective eye protection lequpments |wear chemical splash goggles when there isthe potential for exposure ofthe eyes oui, vapor er mist. [skin and Body protection: (choose body protection according to the amount and concentration ofthe dangerous substance atthe work ‘lace. Discard gloves that show ears, pinholes, o sigs of wear _ Wear resistant gloves (const your salty equpmert supp 9. Physical and Chemical Properties Paton cota povewance ear amber ig jenny NA Fa NA creel tpentee [NA soln Pri wee ce renee WA Metin port 08% ‘Aegon orga NA fash pnt ae Decnposton enews [ NA ban er nbusen eat NA Theo corcarrason ha pars Oar Tmehghconentaton ato te | Vowberate shou ban eer —.—————qe_ weim Beer 20211001 page: gy REEL = BRISTOL RITA Version coomaaaemaen ‘Quality Products with in-Time Service and Innovation SRE MATERIAL SAFETY DATA SHEET renee eee Product Name: — SWANCOR CHEMPULSE 901-P ‘Var presse A 3mmrgg20e Infarmabiy NA Density NA Vici 360-6508 Vapor densi 261 ‘sor teshas waive | 0017-1 SeemDETECT) Souity NA 10. Stability and Reactivity Sty Stabe room eTpeaue [ne nazards might encounter |aaay coour ln artes stuation. [Exposure to excessive eat o” Greet sunshine OF open Warn Slarage ih Open eartane’s, Soraoe| [Sensttons to avoid labove 38° (100°). Contamination win oxidizing agents. Incompatible materiais [Stora alas, strong mineral acids and ovdzing agents Iazardous carbon Moroxice, Carbon Dicwde, Low Mclecsar Weight Hycrocarbon, Organic Aces. (decomposition products eae 11. Toxicological information [ts : 5.000 maha (at Ora) [act toy [Ls 2.770 pom 4H (Rat. Vapor) Eponre one Sun conact, Eye Cartac, Ingeston [SEnirion 3 Tway cause skin tation anor derma. Eve riaton oF aos ay cae an Wo He yes TeSDTLOY Opt ad Sih lemosen [causes seus eye etaton [Brat or an aleries [Not classes base on avatabenioaton [cern cal muagencty|Forsirene: Suspected of causa genete defers [carcnopenty —__[Foratrene: Suspected of causing career ia [Genotoxicity [Not classified based on available information. Sate wrest oaar feccy ater singe May couse respratry tation exposure Seay [nas carae gaan mci st rh brand ss ya [spose ti alaion danger [Does not cause eepaioy senza longer tse Not caceied based on avalalenforabon. 12. Ecological information [Ecotony LC 0 (Pimepalea promis) 251.74 Bgl @GH Based on wiomaton fer sirene Nateral realy Deaeyrnave. Patses OECD Teta) Wr 15) Persistence and dearadabity Jnodecradaity Materal climate Bodegredatie Reaches more ban 70% minerazeton [GECB ests) tc imerent oda ada (Bezarcanvaion [Beconcenaon actor (OCF) “135 Ivobiyn eso [Reasy bocepeaanie [verre hazard Canna De GED We Geo URSA ang oF A |Other harmful influence froxde to aquatic ite bug ee 73. Disposal Considerations [D0 NOT DUN INTO ANY SEWERS, ON THE GROUND, OR NTO ANY BODY OF WATER. Al tsposat mettods must be in comtence with al Fede, SiatsProvincal an local lav an Iepuatons, Reguaions may vary in erent oats Waste charactenzaters and camlance wt} sopscable ws are the esponibit sly of he vast geet 14. Transport information Dispose considerations [UN No. 866 [UN proper shigping name [RESIN SOLUTION _ OO Revision 5 : Date 2021.10.01 pag ctcey a: RRBL RSA - MAB - HAMA) Version oT Quality Products with In-Time Service and innovation MATERIAL SAFETY DATA SHEET roe knw & Enron romeo Say Product Name: —SWANCOR CHEMPULSE 901-P [Transport hazard class ls a [Packaging group iw Marne pottants (iN) No. a ER ST Pact iwerounas ROSS EAE aay aay ea maaan eS sore 15, Regulatory information ae eee eee Piensa cane ee ae eae cence ce occ a [erscasessanesiiescmaeed fester Stes Feel eee rep epi memempeepe a ewe aoe pr oe one See ee scecsee Cicet teene as easy eee er ee ee re eee ree erst ans Sa eee epee ra nee cere Par ea oC ee oe ae Secraeacereey esac neon Re inl eer hesmbnasaucsanccoseer arson ee eral nae ete ergiinmte aca er aaa eet eet Raetecrmes oc cree Reece 16. Other information i SESE SaRL a SRE TS an vom fieeeene here aa peescnees heat feeminiceaanette a Hazardous Substance LS ewson 20211001 ggg: gy BREE REIN MINTS - BIRLA a Quy Producs wih r-Time Service and lmovaton SRE MATERIAL SAFETY DATA SHEET Gren Enugy#Emvenmenta Poet & ay Product Name: —SWANCOR CHEMPULSE 901-P [is SOS information is cnly avaiable for sppropite products, unless otherwise indicated, tis lrocuct with other substances macue cannot applicable. This SDS is provided safety ifermaton for loscsimer Ine stat who has had professional vaiing, The uses of SOS must make an independent judgment lon the sutatity under special condtions.H the SOS applcaton resus ies under a special \cccasion, he SOS compilers donot bear any responsibil IName * SWANCOR Make unit [Adoress/Tetephone | NA Make people Positonal ie RD ENGINEER [Senate Ten Chang make date [aozt-10.01 — Beyer oat 10.04 BEEL - MSR TRB - DARA Page: 7/7 Version 0 Quality Products with In-Time Service and Innovation a SITE a ds Vn ot Pot oth Et sa Worcs ie | DOCUMENT ‘te, Ld. Super Singapore Pe. a and Samsung Engineering (Thailand) Co,Ltd. TOP No.: R1118111-1TDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE | WATER PIPE REPAIRING FOR Do2 CONTR. Doc. No.: 2044-00000-CI-512579 ATTACHMENT 3: Material description BUTANOX M-06/tanansiiaya‘ia BUTANOX M-06 AkzoNobel 5,” Product Data Sheet Butanox® M-60 Product description Specifications Characteristics Storage Thermal stability Major decomposition products Methyl ethy! ketone peroxide, solution in dimethy! phthalate Cee cH, v0—-4-0-0-F--o0n woo—¢—o0n : HooH Ho GH, H, CAS No 1998-204 EINECSIELINCS No. risest2 TSCAstauis feted on ventory Avpesrance Clear and coors quid Total acive oxygen 98-10% Density, 20°C 1.170 glem* Viscosity, 20° 25mPas ve to the relatively unstable nature of organic peroxides a loss of ‘quality can be detected over a period of ime. To minimize the loss of ‘quality, AkzoNobel recommends a maximum storage temperature (T, max ) for each organic peroxide product For Butanox M60 T,max= 26°C When stored under the recommended storage conditions, Butanox M-60 will remain within the AkzoNobel specifications for a period of atleast 6 ‘months after delivery. Organic peroxides are thermally unstable substances, which may undergo self-acceleratng decomposition. The lowest temperature at which selfaccelerating decomposition of a substance in the orginal packaging may occur isthe Sel Accelerating Decomposition Temperature (SADT), The SADT is determined on the basis of the Heat ‘Accumulation Storage Test. For Butanox M-60 SADT: 60°C leat Accumson Storage Tests arecogize test meth or te determination ot ‘he SADT eergane porxtes (see Recommendations onthe Transport Dangereus {Geocs, Manulf Tess ana Citra Untog Nabe, New York and Ganev) Carton diaxide, water, acetic acid, formic acd, propionic acid, methy! ethyl ketone, 1 654290505 2017 Page tad Packaging and transport Applications Par = pats perhundresresin ‘The standard packaging is a 30| HDPE can (Nourytainer®) for 30 kg peroxide solution. In Asia Pactic the standard packaging is a 301 HDPE can for 20 kg peroxide solution. Both packaging and transport meet the international regutations. For the availabilty of other packed quantities contact your AkzoNobel representative. ‘Butanox M-60 is classified as Organic peroxide type D; liquid; Division 5.2; UN 3105, ‘Butanox M-60 is a general purpose methyl ethyl ketone peroxide (MEKP) forthe curing of unsaturated polyester resins inthe presence of 2 cobalt accelerator at room and elevated temperatures. Bulanox M-60 sa 10% higher concentrated version of Butanox M-50. ‘The curing system Bufanox N-6O!cobalt accelerators particularly suitable for the curing of gelcoat resins, laminating resins, lacquers and castings; moreover the manufacture of light resistant parts may be possible contrary to the curing system benzoyl peroxidelamine accelerator. Practical experience throughout many years has proven that by the {guaranteed low water content and the absence of polar compounds in Butanox N-B0, this peroxide is very suitable in GRP products for eg ‘marine applications. For room temperature application its necessary to use Butanox M-60, together with a cobalt accelerator (e.g, Accelerator NL-49P). Depending on working conditions, the following peroxide and accelerator dosage levels are recommended: Butanox M60 4-4 phe" ‘Accelerator NL-49P- 08-3 phr 1 654200002017 Poyezers (Cure Characteristics In a high reactive standard exthophthalc resin in combination with ‘Accelerator NL-4SP (= 1% cobalt) the folowing application Characteristics were determined: Geltimes at 20°C 2 ph Butanox M-60 +05 phr Acc. NL-40P 10 minutes 2 ph Butanox M-50 +0.5 phe Acc NL-AOP re minutes 2 ph Butanox M60 + 1.0 phr Acc. NL-40P 6 minutes 2 hw Butanox M50 + 1.0 phe Ac. NL-A6P T minutes Cure of 1 mm pure resin ayer at 20°C ‘The speed of cure is expressed asthe me to each a Persoz hardness of respectively 30, 60 and 120s. Pesce: 30 © 60120 2p ButanoxM60 +05 phr Acc NL4GP 223812 2h ButanoxM-50 +05 phi Acc NASP 244113 2 phe ButanoxM60+ 1.0 phr Acc NASP 13258 2 phe Butano M60 +1.0pM Acs. NCAP 17) 30S Cure of 4 mm laminates at 20°C ‘4 mm laminates have been made with a 450 gm® glass chopped strand mat. The glass content inthe laminates is 30% (wi). ‘The following parameters were determined: = Time-lemperature curve = Speed of cure expressed as the ime o achieve a Bacol hardness (934-1) of (05 and 25:30 respectively “Residual styrene content after 24 hat 20°C and a subsequent postcure of 8h atB0"c, Gel Tmeto Peak time Peak’ exctherm min, min. °C 2 phe Butanox M-00 +0.5 pr Acc. NLAQP 2 = @ 2 ph Butanox M-50 +0.5 pi Acc. NLAQP es 2 phr Butanox M-60 +1.0 pr Acc. NLAQP feeeeieeeeenl 2 phe Butanox M-S0 + 1.0 phr Acc. NLAQP a Barcol_ Res. styrene 052530 24h + 8n aoe arc hon % % 2 phr Butanox M-80 + 0.5 ph Acc. NLAQP 2 13 57 03 2 ph Butanox M80 +0.5 ph Acc. NUAOP Seer aaiel oa: 2 phe Butanox M-80 +1.0 ph Age. NLAOP 47 on 2 ph Butanox M60 + 1.0 ph Acc. NLAQP 1 5 Of 15 6542808, 2017 Pages Pot ite at 20°C Pot Ives were determined of a mixture of Butanox M-60 and a non preaccelerated UP resin at 20°C. 2 phr Butanox M-60 10h 4 phir Butanox M-60 6h _utanox an Nowlin ae registered vasemars of Akzo Nobel Chemieals BV. of peerage ‘aetna oe ewetoanc. iment Reseece fee an ‘won aonee cnt “7865420 001uy 2017 120162017 AkzoNobelPlymerChamsry Payedare revo Sy aa am. SITE Tharol ‘Joint Venture of Petrofac South East Asia v ie DOCUMENT Pte, Ltd, , Saipem Singapore Pte. Ltd. and ‘Samsung Engineering (Thailand) Co.,Ltd. ‘TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 ATTACHMENT 4: Material safety data sheet BUTANOX M-06/tanasiiayasuana alaaaiunastaq BUTANOX M-06 SAFETY DATA SHEET ‘SDS No: 2 DATE ISSUED: August 2016 This product is hazardous according to Work safe Australia. BUTANOX M-60 MEKP CATALYST. 1. PRODUCT IDENTIFICATION GHS Product Identifier Butanox M-60 Product Code 4317521 Contact Information Fiberglass (A/Asia) Sales Pty. Ltd 2 Lincoln Street, Minto NSW 2566 Phone: (02) 98201144 Fax: (02) 9603 2314 Emergency Phone: (02) 9820 1144 (Business Hours) Poisons information Centre Westmead 1800 251 525 or 131126 Chemeall Australia 1800 127 406 New Zealand +64.3-3530199 National Poisons Centre New Zealand 0800-764 766 Recommended use of the chemical and restrictions on use Curing Agent. Other Names Methyl Ethyl Ketone Peroxide, MEKP Butanox M-60 ‘Additional Information Itis the user's responsibilty to determine the suitability of this product for their ‘applications and their method of use. 2. HAZARD IDENTIFICATION GHS classification of the Substance/Mixture Classified as Hazardous according to the Globally Harmonised System of Classification and labelling of Chemicals (GHS) including Work, Health and Safety regulations, Australia Not classified as Hazardous according to the Globally Harmonised System of Classification and Labelling of Chemicals (GHS) including Work, Health and, Safety regulations, Australia. Acute Toxicity - Inhalation: Category 4 ‘Acute Toxicity - Oral: Category 4 Eye Damageliritation: Category 1 Organic Peroxides: Type D Skin Corrosion/iritation: Category 18. Signal Word (s) DANGER Hazard Statement (s) H242 Heating may cause a fire H302 Harmful if swallowed H313 May be harmful in contact with skin. H314 Causes severe skin burns and eye damage H332 Harmful if inhaled, 1 of 7 FGA SDS - Butanox M60 Classified As Hazardous Pictogram (s) Precautionary ‘Statement-Prevention Precautionary Statement-Response Precautionary statement-Storage Precautionary statement-Disposal Corrosion, Exclamation mark, Flame o > © 210 Keep away from heat/sparks/open flames/not surfaces. No Smoking. 220 Keep away from dir, rust, chemicals in particular. 234 Keep only in original container. 260 Do not breathe vapour. 261 Avoid breathing mist vapours and sprays. P264 Wash hands and contaminated skin thoroughly after handling. 270 Do nat eat, drink or smoke when using this product. 271 Use only outdoors or in a well ventilated area, P273 Avoid release to the environment, 'P280 Wear protective gloves eyelface protection and protective clothing, P301+P330+P331 If Swallowed: rinse mouth, Do NOT induce Vomiting, 'P303+P3614+P353 If On Skin (or hair): Remove/Take off immediately all contaminated Clothing. Rinse skin with waterishower. P304+P340 If inhaled: Remove victim to fresh air and keep at rest in a position comfortable for breathing P305+P351+P336 If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. 310 Immediately call a POISON CENTRE or a doctor/physician. P330 Rinse mouth, P363 Wash contaminated cloth before reuse, P08 Store locked up 410 Protect from sunlight P411+P236 Store at temperatures not exceeding 25ffiKeep cool P420 Store away from other materials, 501 Dispose of contents and container according to local regulations, 3. COMPOSITION/INFORMATION ON INGREDIENTS. ‘Composition, inform: Ingredients, ‘on ingredients ‘There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section. Name CAS Proportion Methyl ethyl ketone 1338-23-4 30-60% peroxide Methy| ethyl ketone 7893-3 110% 4, FIRST-AID MEASURES First Aid Measures: Inhalation Ingestion Skin ‘You should call a doctor or Poisons Information Cenire if you feel that you may have been poisoned, bummed or iritated by this product. Have the Safety Data Sheet with you when you call, Immediate medical attention is required. Move out of dangerous area. Show this safety data sheet to the doctor in attendance. If breathed in, move person into fresh air. Consult a physician after significant exposure. ‘Clean mouth with water and afterwards drink plenty of water. Never give anything by mouth to an unconscious person. Take victim immediately to ‘hospital. 00 NOT INDUCE VOMITING! May cause chemical burs in mouth and throat, ‘Take off contaminated clothing and shoes immediately. Rinse immediately with plenty of water. Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. Page 20f7 FGA SDS. Classified As Hazardous Eye Contaet Rinse thoroughly with plenty of water. Get medical attention immediately. Continue to rinse during transport. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. Small amounts splashed into eyes can cause ltreversible tissue damage and blindness. Indication of immediate medical attention and special treatment need if necessary. Treat symptomaticall. ‘Most important symptomsieffects, acute and delay ‘Symptoms: The symptoms and effects are as expected from the hazards as sown in section 2. No specific product related symptoms are known. Risks: Harmful if swallowed ir if inhaled. Causes serious eye damage. Causes severe burns. 5. FIRE FIGHTING MEASURES: Fire Fighting Measures Inthe event of fre, wear self-contained breathing apparatus. Use water spray to cool unopened containers. Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and ‘contaminated fire extinguishing water must be disposed of in accordance with local regulations. Suitable Extinguishing Media Waterspray, alcohol-resistant foam, dry chemical powder, CO2 Hazards From Combustion Products Fire will produce smoke containing hazardous combustion products (see section 10) ‘Specific Hazards Arising From The Chemical CAUTION: reignition may occur. Supports combustion. Water spray may be ineffective unless used by experienced firefighters. Heating may cause ‘decomposition with release of toxic fumes. Hazchem Code 2WE Decomposition Temp. ‘SADT - (Self accelerating decomposition temperature) isthe lowest temperature at which self accelerating decomposition may occur with a substance in the packaging {as used in transport, A dangerous self-accelerating decomposition reaction and, Under certain circumstances, explosion or fire can be caused by thermal decomposition at and above the SADT. Contact with incompatible substances can cause decomposition below the SADT. Other Information Protective equipment: Firefighters must wear fire resistant protective equipment. Wear approved respirator and protective gloves. 6, ACCIDENTAL RELEASE MEASURES ‘Methods And Materials For Containment And Cleaning Up Keep wetted with water. Soak up with inert absorbent material and dispose of as hazardous waste. Confinement must bbe avoided. Never return spills in original containers for re-use. Personal Precautions Use personal protective equipment (See Section 8) Wear respiratory protection. Ensure adequate ventilation. Remove all sources of ignition. Beware of vapours accumulating to form explosive concentrations. Vapours, can accumulate in low areas. Environmental Precautions Prevent product from entering drains. if the product contaminates rivers and. lakes or drains, inform relevant authorities. [ .HANDLING AND STORING Precautions for Safe Handling For personal protection see Section 8. Avoid formation of aerosol. Do not breathe vapours or spray mist. Smoking, eating and drinking should be prohibited inthe application area. Provide sufficient air exchange and/or exhaust in work rooms. Open drum carefully as content may be under pressure. Dispose of rinse water in accordance with local and national regulations. Use explosion protected equipment, Page 3 of 7 FGA SDS ~ M60 Conditions for safe storage, including any Storage Temperatures Classified As He Keep away from sources of ignition — no smoking. No sparking tools should be used. Keep away from reducing agents (e.g. amines), acids, alkalies and heavy metal ‘compounds (e.g. accelerators, driers, metal soaps). Do not cut or weld on or near this container even when empty. Keep away from combustible material \compatibilities No smoking, Electrical installations/working materials must comply with the technological safety standards. Keep only in the original container. Store away from other materials. For maximum quality, store below 25°C Additional information on precautions for use Other Information Fire and explosion prevention: Use explosion protected equipment. Keep away from ‘sources of ignition - No smoking. Use non-sparking tools in areas where explosive ‘vapouriair mixtures may occur. Do not cut of weld on or near this container even, when empty. Itis recommended to use electrical equipment of temperature group T3. However, autoignition can never be exicuded. Wash hands thoroughly after hhandiing or contact. Keep working clothing separately and do not take them home, [ 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Exposure Controls, personal Protection Occupational Exposure imit Values Methy! ethyl Ketone Peroxide ‘Methyl ethyl Ketone ‘The following Australian and New Zealand Standards will provide general advice regarding safety clothing and equipment: Respiratory equipment: ASINZS 1715, Protective Gloves: AS 2161, Industrial Clothing: AS2919, Industrial Eye Protection: AS1336 and AS/NZS 1337, Occupational Protective Footwear: AS/NZS2210. Name STEL TWA maim3 ppm mgim3 pom, Footnote 15 oz Peak limitation 890 300 445 150 ‘Appropriate Engineering Controls Respiratory Protection Eye Protection Hand Protection Body Protection Hygiene Measures Other Information Explosion proof ventilation recommended. Effective exhaust ventilation system. Ensure that eyewash stations and safety showers are close to the workstation location, Inthe case of vapour or aerosol formation use a respiratore with an approvide fier. Filter A, ‘Tightly fiting safety goggles. Wear face-shield and protective sult for abnormal processing problems, Butyl rubber. Neoprene. Wear suitable protective clothing. Handle in accordance with good industrial hygiene and safety practice. When Using do not eat, drink or smoke. Wash hands before breaks and at the end of the day. Prevent product from entering drains. Of the product contaminates rivers and lakes or drains inform respective authorities. Page of7 FGA SOS- ButanoxW-s0 Classified As He ‘9. PHYSICAL AND CHEMICAL PROPERTIES Form’ ‘Appearance Odour Decomposition Temperature Melting Point Freezing Point Boiling Point ‘Solubilty In Water Solubility In Organic Solvent Specific Gravity pH Vapour Pressure ‘Vapour Density (Air=1) Evaporation Rate Coefficient WateriOil Distr. Viscosity Volatile Component Flash Point Flammability Auto Ignition Temperature Flammable Limits-Lower Flammable Limits Upper Explosion Properties Oxidising Properties Other Information Liquid Colouriess. Faint SADT - (Self accelerating decomposition temperature) is the lowest temperature at ‘which self accelerating decomposition may occur with a substance in the packaging as used in transport. A dangerous self-accelerating decomposition reaction and, under certain circumstances, explosion or fire can be caused by thermal ‘decomposition at and above the SADT. Contact with incompatible substances can ‘cause decomposition below the SADT. <= 10°C Solidfies at or below -10°C Decomposes below the boiling point Partly miscible, Miscible with phthalates. 1.47 at20°C Weakly acidic. Not Determined, Not Determined, No data available Not Determined 25mPa.s at 20°C. Not Determined ‘Above the SADT Value. No flash point was obtained, but the product may release flammable vapour. Decomposition products may be flammable. ‘Test method not applicable (see Section7) Not determined, Not determined. No Not classified as oxidising. Peroxide content: 96. ‘Active oxygen content: 9.8 - 10.0% Organic Peroxides: 26% SADT: 60°C See also Section 10 10. STABILITY AND REACTIVITY Reactivity Chemical Stability Conditions to A Incompatible Materials Stable under normal conditions. Stable under recommended storage conditions. Heat, flames and sparks. Confinement must be avoided. Contact with the following incompatible materials will result in hazardous decomposition: Acids and bases, iron, copper, rust, heavy metals and reducing agents. Do not mix with peroxide accelerators, unless under controlled processing, Use only stainless steel 316, PP, polyethylene or glass-lined equipment. For queries regarding the suitabilty of toher materials please contact the supplier. Hazardous Decomposition Products Carbon oxides, acetic acid, formic acid, propanoic acid, methyl ethyl ketone. Possibility of hazardous reactions Hazardous Polymerization No dangerous reaction known under conditions of normal use. Will not occur. Page Sof7 FGA SDS -Butanox M-60 Classified As Hazardous 11, TOXICOLOGICAL INFORMATION Toxicology Information ‘Acute Toxicity ~ Oral Acute Toxicity - Dermal ‘Acute Toxicity -Inhalation Respiratory sensitization ‘Skin Sensitization Gorm call mutagenicity Carcinogenicity Reproductive Toxicity STOT-single exposure STOT-repeated exposure Aspiration Hazard Serious eye damage irritation No experimental toxicological data of the product as such available.The following data are applicable to the ingredients) isted below: LDS0 Oral: 1,070 mg/kg Species: Rat Method: OECD Test Guideline 401 LD50: 4,000 mg/kg Species: rabbit Method: OECD Test Guideline 402 LC50 (Rat): 4.5 mgf Exposure time: 4h Test atmosphere: dust/mist Not classified based on available information, Not classified based on available information, Not classified based on available information, Not classified based on available information, Not classified based on available information. Not classified based on available information, Not classified based on available information, Not classified based on available information, Species: rabbit Result: Risk of serious damage to eyes. Classification: risk of serious damage to ‘eyes. Method: tested according to Annex V or directive 67/548/EEC. Species: rabbit Result: sub-category 1B Classification: category 1B ‘Method: tested according to Annex V of Directive 67/548/EEC. 12. ECOLOGICAL INFORMATION Ecological Information Ecotoxicity Persistence and degradability Mobility Bioaccumulative Potential Other Adverse ‘An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Toxic to aquatic life. No data is available on the product itself No information available, No information available, No information available. No information available. No information available, 13. DISPOSAL CONSUDERATIONS Disposal Considerations Product Disposal Container Disposal Dispose of waste according to applicable local, state and federal regulations The product should not be allowed to enter drains, water courses or the soll Do not contaminate ponds, waterways or ditches with chemical or used ‘container. Hazardous waste. Empty remaining contents. Dispose of as unused product. Do not burn or use a cotting torch on the empty drum. Due to the high risk of contamination recyclingirecovery is not recommended. Follow all warnings even after the container is emptied Page 6 0f7 FGA SDS -Batanox N60 fied As Hazardous 14. TRANSPORT INFORMATION U.N. Number 3105, UN proper shipping ORGANIC PEROXIDE TYPE D, LIQUID - Methyl ethyl ketone peroxide name Transport hazard, 552 class(es) Hazchem Code We EPG Number 5K IERG Number 32 IMO Marine No. Pollutant IMDG EMS. FAS Other Information Dangerous Goods of Class 5.2 Organic Peroxides are incompatible in a placard Toad with any of the following: - Class I, Cass 2, Class 3, Class 4, Class 5.1, Class 7, Class 8, Fire risk substances and combustible liquids 15. REGULATORY INFORMATION Poisons Schedule ss Symbot C-Comrosive Hazard Category 0 - Oxidising AICS (Australia) Harmful, Corrosive, Oxidising All components of this material are listed on or exempt from the Australian Inventory of Chemical Substances (AICS). Classified As Hazardous 16. OTHER INFORMATION Other Information ADG Code: Australian Code forthe Transport of Dangerous Goods by Road and Rail, 7th Elton AICS: Australian Inventory of Chemical Substances ASCC: Office ofthe Australian Safety and Compensation Council CAS number: Chemical Abstracts Service Registry Number EPA: Environmental Protection Agency Hazchem Code: Emergency action code of numbers and letters that provide information to emergency services especially fire fighters International Agency for Research on Cancer NICNAS: National Industral Notification & Assessment Scheme NIOSH: National Institute for Occupational Safety & Health NOS: Not otherwise specified ‘ational Toxicology Program (USA) EL: Occupational Exposure Limit ‘OSHA: Occupational Safety & Health Administration PBT: Persistent Bioaccumulative Toxic chemical PMCC: Pensky Martens Closed Cup R-Phrase: Risk Phrase STEL: Short Term Exposure Limit SUSMP: Standard for the Uniform Scheduling of Medicines & Poisons ‘TWA: Time Weighted Average UN Number: United Nations Number -PyBL: Very Persistent and Very Bioaccumulative WEEL: Workplace Environmental Exposure Level WEL-TWA: Workplace Exposure Limit, Time Weighted Average ‘THIS SDS SUMMARISES OUR BEST KNOWLEDGE OF THE HEALTH AND SAFETY HAZARD INFORMATION OF THE PRODUCT AND HOW ‘TO SAFELY HANDLE AND USE THE PRODUCT IN THE WORKPLACE. EACH USER MUST REVIEW THIS MSDS IN THE CONTEXT OF HOW THE PRODUCT WILL BE HANDLED AND USED IN THE WORKPLACE. IF CLARIFICATION OR FURTHER INFORMATION IS NEEDED TO ENSURE THAT AN APPROPRIATE RISK ASSESSMENT CAN BE MADE, THEUSER SHOULD CONTACT THIS COMPANY SO WE CAN ATTEMPT TO OBTAIN ADDITIONAL INFORMATION FROM OUR SUPPLIERS. (OUR RESPONSIBILITY FOR PRODUCTS SOLD IS SUBIECT TO OUR STANDARD TERMS AND CONDITIONS, A COPY OF WHICH IS SENT TO OUR CUSTOMERS AND IS ALSO AVAILABLE ON REQUEST EndofSDS.._ Page 7of 7 FGA SDS- Buuanae Ms DOCUMENT Pte, Ltd. , Saipem Singapore Pte. Ltd. and ‘Samsung Engineering (Thailand) Co,Ltd. i [mone 53 ao cm. | Wome AP | ook cmerns | Tharou Joint Venture of Petrofac South East Asia | - | R1118111-ITDC04-10-M DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 r ata J ATTACHMENT 5: Material description P20 Powder Chopped Mat /tananstiayayiag P20 Powder Chopped Mat JUSHI [ {Tc Fr Cpe Sa Ut P20 Powder Chopped Strand Mat is made of randomly distributed Chopped E glass strands held together by an powder binder. 20 is compatible with unsaturated polyester, vinyl ester, epoxy and phenolic resins. 20 is designed mainly for use in the hand lay-up process and also ‘suitable for use in fiament winding, compression molding and continuous. laminating processes. Ii end-use applications include boats, bath equipment, automotive parts, chemical corrosion resistant pipes, tanks, cooling towers and building components. (© Satinat eas of mara ag pt, ond aoa © Gaossttrough ate wat nan 89 aaa rncvng rig ame and eer rst © Lawracn consumption © High mecancal enh of he cope pecs ch Powder Chopped Sand Matis wound oto a paper ibe whic has an Insite ameter of 90mm, The rol ouscedameter a approximately 266mm. cn role wrapped up pit im angen packed ne cardboard ox. The rol ere stacked horizontally or verily ate pats, Al pallets are tech appear sapped 0 main siabty aig anspor Unies atnenise seeded, powder chopped sand mats shouldbe store in oo dy water poo ae. Its econmendod thet me room temperature and humid be sways manned a 51 to 35 and 5% 1 65% respec JUSHI GROUP CO., LTD. Feat woneecoer] Seca] oom eee [ew [wre | ew [en z ra es = uence [ear | ws | [ ones a SITE DOCUMENT a Joint Venture of Petrofac South East As Pte, Lid. Saipem Singapore Pte. Ltd. and ‘Samsung Engineering (Thailand) Co, Ltd. DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 TOP No.: R1i18111-ITDCO4-10-MST-10516 ‘CONTR. Doc. No.: 2044-00000-CI-512579 ATTACHMENT 6: Material safety data sheet /ianarsiayasuarnmlaantiunas Taq, @, GOeaaRna JUSHI GROUP CO, LTD. MATERIAL SAFETY DATA SHEET according to 1907/2008/EC, Article 31 es fesse a ste — = fen = SosGSRDa Bess |_avs nee0zn10 JUSHI GROUP CO., LTD. ‘Main Drafter hantao_ fe ca Tae [Rasa —sare—e ven SS] PS | Paar | eae, |S tnan nos | noo | 2012-98 | 201208 | 1 — [rae | CT pate | 0307 | a SECTION 1 —- CHEMICAL PRODUCT AND COMPANY IDENTIFICATION CHEMICAL PRODUCT IDENTIFICATION: Continuous Glass Fiber Products, Including Assembled Roving, Direct Roving, Dry Chopped Strands, Wet Chopped Strands, Woven Roving, Stitch Chopped Strand Mat, Power Chopped Strand Mat, Emulsion Chopped Strand Mat , Stitch Combo Mat, ‘Woven Roving Combo Mat, Glass Filament Yarn, Marketable Cake, Cut Strands, Texturized Yarn. MANUFACTURER INFORMATION: JUSHI GROUP CO., LTD. NO.669Wenhua Rd.(S.), Tongxiang Economic Development Zone, Zhejiang 314500, China FAX NUMBER Customer Service: +86-573-88181388 Intemational Sales: +86-573-88181058 Domestic Sales: +86-573-88136222 COMPANY EMERGENCY TELEPHONE: (8:30-16:40 In BeiJing, from Monday to ‘Saturday ) Customer Service: +86-573-88136367 Intemational Sales: +86-573-88181025 Domestic Sales: +86-573-88181016 E-mail: services@jushi,com Jushi Spain, S.A. Avd. de Barajas, 24. Planta 2. (Edificio Gamma, Parque Empresarial Omega). C.P 28108. Alcobendas (Madrid) Spain Page 1 of 10 wat SoraaRoa JUSHI GROUP CO. LTD. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-38 MSDS Number: _Q/JS J0520-2012 TELEPHONE: 0034 917678817 FAX NUMBER: 0034 917678818 E-mail: nicanor.amor@jushispain.com Jushi(India) FRP Accessories Private Limited 310 CREATIVE INDUSTRIAL ESTATE N/M. JOSHI MARG MUMBAI 420011 India TELEPHONE: 0091 224 033 5375/ 224 033 5333 FAX NUMBER: 0091 224 033 5334 E-mail: vishal@jushifrp.com Jushi Group Sinosia SA Composite Materials 465 Neri Hare Road Atlantis Industrial7350, Capetown, South Africa TELEPHONE: 27 21 5772747/00852 2541 1114 FAX NUMBER: 27 215772727 E-mail: w_w9@mweb.co za / info@jushisinosia.co.za Jushi Italy SRL VIAADIGE 10/12 21043 CASTIGLIONE OLONA (VA) TELEPHONE: 0039 0331857918 FAX NUMBER: 0039 0331825521 E-mail: essebi@ jushitaly.it Jushi Canada Fiberglass Co., Ltd. Markham, Toronto Canada TELEPHONE: 001 9054777628 FAX NUMBER: 001 9054776047 E-mail: a.gardiner@jushicanada.com JUSHI France SAS 65 RUE DU DAUPHINE 69800 SAINT-PRIEST France TELEPHONE: 33 472 78 20 48/33 (0) 4 7278 20 62 Page 2 of 10 SoR@eRDa JUSHI GROUP CO, LTD. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-3-8 MSDS Number: _Q/JS J0520-2012 FAX NUMBER: 33 47278 20 41 E-mail: fabrice. bani@jushi.fr JUSHI SINGAPORE PTE. LTD 10 UBI CRESCENT, #05-70 (LOBBY D)UBI TECHPARK, SINGAPORE 408564 TELEPHONE: 65 67425118 FAX NUMBER: 65 6742 7108 E-mail: hsseng@jushi.com HELM AG Hamburg Nordkanal Strasse 28 D-20097 Hamburg Germany TELEPHONE: 49 40 2375 1330 FAX NUMBER: 49 40 2375 1845 |e. kloevekorn@helmag.com E-mai Gibson Enterprises, Inc. DBA JUSHI USA 4982 4th Street Irwindale,CA 91706 U.S.A. TELEPHONE: (626) 960-2038 FAX NUMBER: (626) 960-2037 E-mail: alan.gardiner@jushiusa.com If you couldn't contact one of them, please call the company emergency telephone MSDS NUMBER: ‘Quis J0520 EFFECTIVE DATE: March 8, 2012 | SECTION 2 —- COMPOSITION / INFORMATION ON INGREDIENTS. Ingredients of Products: Product Name Glass, % | see, % | BC | Water, x Assembled Roving 98.0~99.5 | 0.05~1.80 L 0-0.20 Page 3 of 10 we chegaRmns isnt exour co. io MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-3-8 MSDS Number: Q/JS J0520-2012 Direct Roving 98.7~99.85 | 0.15~1.10 7 0-0.20 Dry Chopped Strands 98.25~99.9 | 0.10~1.65 1 0-0.10 Wet Chopped Strands 87.8~92.0 | 0~0.20 1 8.0~12.0 ‘Woven Roving 98,8~99.85 | 0.15~1.00 1 0-0.20 Power Chopped Strand Mat | 92.45~98.35 | 0.35~1.35 | 1.3~6.0 | 0-0.20 Emulsion Chopped Strand Mat | 93.05~96.65 | 0.35~1.35 | 3.0~5.4 | 00.20 Glass Filament Yarn | 98.6~99.2 | 0.80~1.20 / 0~0.20 Cut Strands 85~92 yi I 8.0-15.0 Marketable Cake 99,2~99.7 | 0.30~0.60 / 0~0.20 Texturized Yarn 99.2~99.9 | 0.10~0.60 1 00.20 CAS No.: Fiberglass: 65997-17-3 Size: N/A Size: Size is a mixture of chemicals applied to the glass strands.Most of this mixture is made up of basically non reactive high molecular weight polymers.often natural ingredients(starches) with no reactive sites,which are not listed as substances in the EINECS nor in the ELINCS appendices. ‘Sometimes size maybe also contain substances of organo-silane family or other substances. The manufacturer considers this risk as negligible as,even though listed as dangerous products, the concentration is extremely low(under 0.1% of total weight) and they are polymerised during the production of glass fibers production. SECTION 3 —- HAZARDS IDENTIFICATION With regard to its composition, these products are articles and not classified as hazardous according to European Directive 67/548/EEC and 99/45/EC and ST/SG/AC.10/30/Rev.2 and their latest amendments. Class ation of Hazards: No information available. Routes of Entry: Ingestion, inhalation, skin and eye contact. Health Effects: Ingestion: Ingestion of the material is unlikely. However, ingestion of the material Page 4 of 10 BoRgaRoa JUSHI GROUP CO.,LTD. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-38 MSDS Number: _Q/JS J0520-2012 may cause gastrointestinal disturbance. Inhalation: Breathing fiberglass dusts and particulates may cause irritation of the nose, throat and respiratory tract. ‘Skin contact: Fiberglass dusts and particulates may cause temporary irritation. Eye contact: Fiberglass dusts and particulates may cause temporary irritation to the eyes. Environmental Effects: Long-term exposure to fiberglass environment may cause temporary effects Inflammation and Explosion Hazards: No information available. SECTION 4 - FIRST-AID MEASURES. Skin Contact: Ifirritation occurs to the skin, rinse with soap and water. Make sure to refrain from rinsing with warm water since warm water will make the skin pores open to allow fiberglass to penetrate more deeply. If fiberglass penetrates the skin, use a wash cloth to help pull out the fiberglass. To avoid further irritation, do not rub or scratch affected skin. If irritation persists, get medical help. Make sure to refrain from using ‘compressed air to remove fiberglass from the skin. Eye Conta Immediately flush eyes with clean water for at least 15 minutes. If irritation persists, get medical help. Inhalatior If inhaled, immediately remove the affected person to fresh air. If irritation persists, get medical help. Ingestion: Normally, ingestion of this material is unlikely. If it does occur, watch the person for several days to make sure that gastrointestinal disturbance does not occur. Do not let the person vomit unless required by medical personnel. If disturbance persists, get medical help. SECTION 5 — FIRE-FIGHTING MEASURES Flammability Classification: Non-flammable. But the size and packing material may burning Page 5 of 10 B65 Da RBG SUSHI GROUP CO_ LTD. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-38 MSDS Number: Q/S J0520-2012 Hazardous Combustion Products: Primary combustion products are carbon monoxide, hydrogen, carbon dioxide and water. Other undetermined compounds can be released in small quantities. Fire-Fighting Methods: Use dry chemical, foam, carbon dioxide and water as extinguishing media. hting Instructions: Fire fighters must use self-contained breathing apparatus and wear full protective gear. Fire-1 SECTION 6 - ACCIDENTAL RELEASE MEASURES. In case of release to land, the material should be scooped up as waste and put into a special container and stored in a designated area._In case of release of water, the material will sink and disperse along the bottom of waterways or ponds and can not be easily removed affer it is waterborne. However, the material is non-hazardous in water. SECTION 7 — HANDLING AND STORAGE Handling: Try to prevent the packing material from be damaged and keep the product inside the packing material to minimize the generation of dusts. Maintain a clean work environment and avoid generation of fiberglass fragments from improper handling, Storage: Keep product in its packaging until use to minimize potential dust generation. SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION Highest Permissible Concentration: National and international hygiene standards are as follows: Permissible Exposure Limit | Permissible Exposure Limit of Component of OSHA ‘ACGIH (8-hr Average Weight ) (8 hr Average Weight ) Total Dust 15 mgim® 10 mg/m® Respirable 3 2 particulates 5 mg/m’ 3 gin Page 6 of 10 7, GoRaaRna JUSHI GROUP CO.,LTD. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-38 MSDS Number: _Q/JS J0520-2012 Respirable Fibre 1 1 fibre/ml Engineering Control: Production areas are closed off and a required relative humidity is maintained. Respiratory Protection: Wear a sulle mask when working In an environment where dust concentration is il Eye Protection: Wear safety glasses and face shield Body Protection: Normal loose working clothing (long-sleeved shirts and long pants) is recommended, Skin irritation occurs primarily at the contact areas such as around the neck and waist Hand Protection: Wear gloves. Skin irritation ocours primarily at the contact areas such as wrists and between the fingers. SECTION 9 - PHYSICLAL AND CHEMICAL PROPERTIES Product Appearance and Propert Flash Point: White or off-white solid; No odor. Not applicable PH Value: Ignition Temperature: Not applicable. Not applicable Melting Point: Explosion Upper Limit >B00°C. Not applicable Boiling Point: Explosion Lower Limit: Not applicable. Not applicable Relative Density: Solubility (in Water): 2.6 Times that of water. Insoluble Relative Vapor Density: Not applicable Product Use: Fiberglass is an inorganic nonmetal material and is used as Plastics reinforcement and acoustical insulation. Page 7 of 10 we SoemaRos smi enour eo. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-38 MSDS Number: _Q/JS J0520-2012 SECTION 10 — STABILITY AND REACTIVITY Stability: This is a Stable material Materials to Avoid: None. Conditions to avoid: None. Hazardous Polymerization Will not occur. SECTION 11 - TOXICOLOGICAL INFORMATION Acute Toxicity: None. Irritability: Fiberglass dusts may cause irritation to skin and eye. Ingestion of fiberglass may cause irritation to the throat, stomach and gastrointestinal tract. Inhalation may cause coughing, sneezing and nose and throat irritation. Experience indicates that inhalation of a large amount of fiberglass may cause difficulty in breathing, congestion and chest tightness. Carcinogenicity: The International Agency for Research on Cancer (IARC), agency of the World Health Organization (WHO), has determined that fiberglass is a non-carcinogenic material because the evidence is inadequate to prove that fiberglass can cause humans and experimental animals to develop cancer. SECTION 12 - ECOLOGICAL INFORMATION No data available for this product. Fiberglass products are not listed as a material harmful to animals, plants and fish. SECTION 13 - DISPOSAL CONSIDERATIONS 8 of 10 5 CORMBRDA fase enor co. e MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-38 MSDS Number: _Q/JS J0520-2012 RCRA Hazard class: Non-hazardous. Disposal Instructions: Dispose waste material according to local environmental regulations. DECTION 14 - TRANSPORT INFORMATION Classification and Code of Hazards: None. UN Code: None. Packing Mark: None. Packing Category: None. Packing Method: None. Transport Instructions: Rolling and moisture should be avoided in transit. SECTION 15 —- REGULATORY INFORMATION SARA title III: Hazard categories: Acute health: Yes Chronic health: No Fire hazard: No Pressure hazard: No Reactivity hazard: No Reportable ingrediedients: Sec.302/304: None Page 9 of 10 5 SoeoeRoa JUSHI GROUP CO.,LTD. MATERIAL SAFETY DATA SHEET according to 1907/2006/EC, Article 31 DATE PREPARED: 2012-3-8 ‘Sec.313: ‘None Clean Air Act: No ingredient is listed. WHMIS(Canada) Status: No controlled. WHMIS classification(s): None. National chemicals inventories Based on the rules enforced with regards to the marketing and use of chemicals in countries where our Jushi products are manufactured, each chemical ingredient of these finished products has to be listed on the National Chemicals Inventory of the specific country where produced. However, glass fiber products are articles under the chemicals inventories listed MSDS Number: QiJS 40520-2012 below and consequently are exempt from listing on these inventories: - The European Inventory of Existing Chemical Substances: EINECS/ELINCS, - The US EPA Toxic Substance Control Act: TSCA, - The Canadian Chemical Registration Regulations: NDSL/DSL, - The Japanese Chemical Substances Control Law under METI: CSCL, - The Australian Inventory of Chemical Substances: AICS, - The Philippine Inventory of Chemicals and Chemical Substances: PICCS, - The Korean Existing Chemicals List: (K)ECL and - The Chinese List on New Chemical Substances. SECTION 16 - OTHER INFORMATION Preparation Date: March 2012 Prepared by: Quality Assurance Dept. , Jushi Group Co., Ltd. Data Verified by: Assistant To President of Jushi Group Co., Ltd Modification Information: Second Version Page 10 of 10 [ = revo © SF am em. nro SITE eer vod DOCUMENT Be, Ltd. Ssipem Singapore Pe: nd Scrsun Engincering (Praia) Coy tt TOP No.: R1118111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 ATTACHMENT 7: Drawing / wuuriaado won SF a om Wren Mi tre eee DOCUMENT pate Sir Soper et Erpauns envi Cee) Go TOP No.: R1i18111-ITDCO4-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 Wrens SITE DOCUMENT revo Fp ae a eine Venture of Petrotac South East Asa WATER PIPE REPAIRING FOR DO2 | DOCUMENT TITLE : METHOD STATEMENT FIRE v. ee | SITE cae DOCUMENT Soren Ena TOP No. R1i18i41-ITDCO4-10-MST-1051 DOCUMENT TITLE : METHOD STATEMENT FIRE taut WATER PIPE REPAIRING FOR D02 CONTR. Doc. No.: 2044-00000-CI-512579 i won SS ae am Wrcn Mee poner | zig sone ‘TOP No.; Rii18111-ITDC04-10-MST-10516 DOCUMENT TITLE : METHOD STATEMENT FIRE WATER PIPE REPAIRING FOR DO2 CONTR. Doc. No.: 2044-00000-CI-512579 ATTACHMENT 8: JSEA for file water pipe repairing / mstianeveuaniniaanauar, Wansemusrudouradantassmusiauviaduinds Job Safety & Environmental Analysis | ~“““"""™=""" 7 seal eee | msitanevomimoanmlasaruuactouraden Petrofac © SS aco mine] | eck B Brownfield © Greenfield | weavonars RILIBII1- adahliualys = ISEA No. CFP- S/C Name | [TDC04-10- Revise no. | 90 4ustiierhi/ Issued date | 15 March 2022 JSEA-100136 smuiffinsieW /Job topic | Fire Water Pipe Repair Work at D02__miaus1u Department / Company name ITD-CIVIL Ginnie laotiinswisnaitonmunaoniounsturaden Wu dumudnnruniaonsoucsdamien ves diumnn, UV uneddwnslasems ISEA review team members (SSHE and Copstruction team from Subcontractor, UJV and Owner/PMC) + | Tandhis P Marek Hse Mor. | ‘de Name ‘roiioge Signature Position ‘de Name meife¥e Signature Position Mond —¢ Aas 2 ‘do Name ‘muiio¥e Signature Position ‘do Name meffogo Signature Position Souwat T, Sumat T- cm. 6 3 ‘de Name ‘aed Signature Position | eName ‘iioge Signature Position cia Ina Approved by ssnennilao Reviewed by Owner/PMC Construction Owner/PMC SSHE 15-25-2092 | Date [tO Merch C02 | pate [é = ox -32. Date _|1b/3/2022_ 1 Aeron hot Doorsp Name [Anu Tp cosyalt name pre sormpavn of | Name | Rossacy S Sign p.amonereny Sign Sign Pe — Sign CODE1 APPROVED: WORK CAN PROCEED ore cope oe CODE? APPROVED: WITH COMMENTS: WORK CAN PROCEED & COMMENT TO BE IN | CODE COOET CORPORATED WITHIN 7 DAYS (CODES REJECTED: WORK CANNOT PROCEED REVISESRESUBMIT —_* oes "NOTE" THE WERRING OF FRE WSK, SOCIR DISTANCING AND ALL OTHER PROUECT COVIO-T ACTON PN AND THAT REGUCATORY REGUREWENT UST BE FOC OWED WHEN CONDUCTING THIS RCTWITY ‘anus malimhronasnty mavtaeushomafinaunernucniRmaDoora COMO Buquslensmusedorrmadrusssiondariwinsinuestonlpskmaddorusuanute Page 1 of 26 Vase BP = Paae Seater myhanievemimoarwuaaaiguacdouiaday Job Safety & Environmental Analysi Petrofac SS ci ittttnd ore sunburn epee fd) Sb ‘JOB DESCRIPTION: Fire Water Pipe Repair Work at 002 Revision: 00 Rise ‘Residual isk Step! Activity | Work Task tential Hazard Consequences | Assessment Hazard Control ‘tion Required by: cfs[e cls DR 1 Ste “ Preparion | 111 Accor causodby | Phystalinuy.? [8 | 2 | L | ProStar Seely mooing (PSST) mustbe [A] 2] U | Sto Engineer mmamow Preparation.) | before srt | ignorance of he reguatons and | rrauiaufums conducted and documented prior sa work Safty Oto wl. rreanfoxra | wonng. ems | satly process. /inglting | murrm shepuitoysqueudaonsy unBudely Ste Supervsor Fon unsafoutul | isfuurarion | einmatifngrudouuactunon sonmrionsus Borer elunygyin una eminleony -Sofe work aroa assessment check! & PTW Worors Bsn Checklist tobe completed before work sta Yhurnalsediuttwfinanans ureusueremeU uvenygnetumninenciondusn -Al raqied PPE shal be worn as pr Pret PE procsdune./oruligunsiursas erulaonverungseduumastirnualt wlurunosiesen ‘12 Accidents eats by nck | -Physzalinune? [8 | 2 | L | Empiajee working any aciviy must be eines | A] 2] | Ste Engineer Searaminw ftinng. improper sto mmnneuyns by VIVTOP andlor tie. pary wining fr tho Seley Ooo wl prectee./yiinnutaiinuma | mann task ht they ae woking on ste! wit Ste Superior Fawihin au uremia shenlienmailn 9 ssfouumtnounal Soare ffoluoyare vvanesudhunmanlagers UN TOP uae 1 wHarmaurmmoKn Wortars fie shvdusvafinanineeyh Page 2 of 26 Vaca mrttanevemiioanmlaoaiguartouradon Job Safety & Environmental Analysis 108 DESCRIPTION: Fire Water Pipe Repair Work st O02 Revision: 00 Rist Residual Riek Stop! Activity | Work Task Potential Haar Consequences | Axsossment Hazard Control ‘Action Requires by: ‘fs ® tis [Re 143 nadequaw PTW ortho | Prysicalininy.? [8] 2 | L | Tamed Appcant Bearer Permit haldertom [A] 2 | L | Sto Engineer mami ect. Hes and ney | amnastnre | | tit U0 be an nk. 14 satay Oe recasona ot ced ern mao. ApplantBearer eirknuoeutPecmit ‘Ste Supersser Fomiin sdoquatey. uayyiarrs | Property Damage. edoreay Bowe fcluoyann thensagumwursionn — | niwliwiuron -freugueuhumsousy Apptean | Borer! Wortrs ifaw svfimnadunranloon ila Permit hide antnuooud / UV sFusna Port Aplean Hote! Bearer shal ensure that appropriate PTW, associated ootetas 27d supporting documents are ineuded. augunsiinprndoyarmongnowune Fawanlufiras -Aaprove PTW | Clarence certs or own {ald must bo aetatio ot so. uaygrevhinm Stiumanyitutetoentoutnhirn 144 inadequate emergency | Physkaliiany 7 [8 [2 | L | Eineyeney Response Teom conn desis [A] 2 | 1 | Siw Engineer iwaramew preparedness. mainfeaenny | Yaanafuns shal be pottad ate nc boots wots Safety Ofoe w faulurstifinonggréulsi | mursn gnifuaosfiachunBognitubnoyfuain ‘te SuporisorFamon fon -Propaty Damsge. demi Baer {folunnsyrn fnew -Aasomby pois hal be latinas for Workers Bain ‘he cation reygrmaunnain -Al so preonnl ar ine and made aware of te respons hugh proc is. St Page 3 of 26 Vzae mstanevemimoaraaaiauactouradas Job Safety & Environmental Analysis Petrofac () SS ci iting pou ts andSamarg provement 08 DESCRIPTION: Fre Water Pipe Repalr Work #002 Revision: 00 Rise Residual Risk Step Activity | _ Work Task Potential Hazard Consequences | Assessment Harard Control ‘Action Required by: tse tls [Rk axruuetouunonondotemegniGuds Provide pendent plan that oncom work activites. FrusSuauenlt eniulunssia ong lutostutonsrunnrnen 11S madequte orengoments | -Physzalinuny? | 8 | 2 | L | Ensue PTW oxonded forthe parod otwor | A] 2 | L | Ske Engowor manne forthe night ext acendes | WRianasdy exende. | Hostiteiimmstuoytyimt Softy Ofer hours work. rosinfuunn | Property Damage. thenmunusnetirinun Ste Supenisor Wawshens wioulivgumlumaninn — | niuShuitime -Night sit Salty checks signed by Apliant Bearer ffaluoyyrn nensfifomynnadanmn ae ensured al the arangoment lng Worars Btn supenion,tagan ee) pice fr each locaton, fusunrreRauinfurine gn serifeleu Appleant uasiosirrmiuurs su arorhe ganas tuum Zcoviosg | 22COVvID1G | 221 Werersiinessos fom | Hoathetoa) || 5 | H | Enwireolworkore ar aware CFP Cowes | @] S | M | Ske Engneerwaramina scton pan.) | actin plan. | apraaing in worplaces. | arzuogumn action plan raquraments. | wssenoubiuile Salty Otter uwslgiens | wulfiiions | euurmushosnms Foaty | iuin innanqneunseninévlarrmumas Ste Supandsor mln fos consis | fos covs1e | urinemulurmufinen uli CFP Cova-19 Bearer fFsluoym -Social istncng to be enforces at al es. Workers gsr ensumusvnemaminugndiviuldenoenn -Face masks must be wom a al mes. / #3 seamihmnouunsonien Prov slebol gl or workers! fli Page 4 of 26 Wasa = a eee maiansisuimaanwvaoaisuasdewaden Job Safety & Environmental Analysis Petrofac ©) SS cit ittitind Wo Peo So En a Pitan Spe pow ts enaSemeng nprevw naa os JOB DESCRIPTION: Fire Water Pipe Repair Work at 02 Revision: 00 Risk Reckval Risk ‘Step Activity | Work Task Potential Hazard Consequences | _ Assessment Hazard Control ‘ction Required by tfs[e tis [Rr uoananedihataliiminome Covi scoring and ime ino every 14 days st UV eine. Tayruonmnnostrann 9 4 te -Check temperature al people every day inthe rmoming. wrreagaangiinsinnugn 9 Fino oh Bi Wook rap atign ot must bo comple fall wna who are working in CFP to follow project requirement and recordin HSE training passport / wiinmufinenaly Inammnmtstiostnumamemdeletienn sosilerfenastorrmumnoslansmsuresiin namamnstitumyntufinoumenwunen a aiinosudaen 3 Equipment? | 84. Diving.) | 81.1 Vehidestaloresin TOP | -Phystcalinuny? | B| 2 | | ~All wiclos must be nspociod by TwIViTOP | A| 2 | | Ste Engneer3mammnu toe and | mrninn | compound. rumuwmuciyn | Wiliam ‘and sicker must bo cepiayed / enawnsttes Safety OFfcor material Mdumulwiufastmueaut — | -Property damage. / shunlinnluiutaedlmueandiw ‘Site Supervisor Havin mmoizaton to rfndtuikume rmmragammen UV /TOP us Boorer ffaluoyar worst. fevurraesnenmnn Wortors (ussiion nung Ensue all voices regdartymainenancs 9s Dever winnaisrn uscquin ports manufacture’ recommendation. Page 5 of 26 Wee BP = Py Sate mvtitansismimaariaiaaaisuaraouraden Job Safety & Environmental Analysis Petrofac © SS cit itttnd om Pu it and Samar Engnootng hears) Co Us {108 DESCRIPTION: Fire Water Pipe Repair Work a 002 Revision: 00 Rise Residual Rik Step Activity | Work Task Potential Hazard Consequences | Assessment Hazara Control ‘Action Required by: tls[e tls [® woah pacman padhalstona aut Griieunety 31.2 Grshod do we specding. | -Physcalinpry) | | 3 | W | -Trecrwersmustbe passed TOP Ostensve | @ | 8 | L | Sie Engraw Gmmmnw Hifamademudoremive | \innaty Devin Course an ive tthe conditions. Salty Ofori safiuchmwn “Property damage. | winriinfomsnoummedutatns Site Supervisor Wawiban srindtuikume sHsomurnnuoudusstisemuammiduns Boor faluoygn Speed lit signs must be sty flowed, 20 Works Qiao loi. ia construction area, 90 ky. ne Dever winnie ise aoa. vines 20 ara Fragman flurssbiiggnos Awunitutrionts, 30 nummy, twutiinens “Ste survey ou ine before meiation ‘transportation, | dorveutumsrieuitsciionsyy Eruaparaeintosrudootmndrku 313 Truk! Vehicles ito | -Physcalinuny? | © | 3 | M | Reversing slowy/coumisornoth 9 B] 8 | | Ste Engineer Sraramna personel or stated facies | Yinnaty -Assignd raid 1 agman por vei, ruck Satay Offeor neary while rvering. so | -Propany demogs. cormachine. SaSghimyynad ts Sto Supenisr Hawi wihwxtammsgulnegad | nuttin susunasiiiggna 1 mudesoniyda Bearer HRelueysy ndifon ufoatna 1 i Works Bins Assigned tine 2 gman fr rater athe Diver winnie front and backside of rate. Fadusaunsaiaad Fegman lunes ‘Wigbygs 2 mx drumbeat Anstal reversing alarm / Aesiagiyay oanouwas Page 6 of 26 \ maianetemiioanaiasatuuacdouradon Petrofac SS cit stintad Le Eg Job Safety & Environmental Analysis | gyress2svem seme, owe te Sema gmc hts Co 4308 DESCRIPTION: Fire Water Pipe Repair Work at DO2 eae Riek Residual Risk ‘top Activity | Work Task Potential Hazard Consequences | Assessment Hazard Control ‘Action Requites by: t[s[R tls Le “Lower car window when back reverse vehicle In ofinory and consructon area. Hasaanszan souudantodunoumie 3:14 Vehicle moving hitworker | -Physicaliniey? | 8 | 3 | L | “Provided Stopper or wooden wedge: /fimien | A] 3 | L | Sto Engineer wammcm plant eauipment. amend | Yan wnpuastodootimuutidontyn Safely Oftoor wu doxinenuniinrninfenscim | Property damage! -Doni parking vehicle for tnd by inside Ste Superisor Fomiens gunaataostaanita indinatom refinery. ahonunfnontatrandisia Bear ffsluoygrn Dont start engin witout operator order Workers dugshirm inside the cabn, snerSvund ose dtout Diver minus aaysd Fagen Glunasbiiqyynns ‘318 Taf jam at Bon Tung | “Community E | 1 | © | -Do not ive ick trough Ban Tung D [tt | Ste Engineer Srommnw communiy. feresieinainc | complint /Wury community, armurmetnnus Sefoy Ofear pms Foxtons Sto Supenisr amis emer slunyare Werte lf Diver mnie Fagman glunastgyanca ‘3118 Mid on te rood o Dust | -Gonmunty nd | E | 1 | L | Taek shal be covered by autablemenos./ | 0 | 1 | 1 | Ste Engineer iminemin fect rom Transpataion. | TOP complet. Seminario Safty Ofer tohozlowwman fanny | Wifursfoaiiunenn “nea raring and have mud most bo Ste Supeniso Wambo ffuncoosinmavds psuunetnuoont provide deening tam ocean the rod. Bearer ifelunygyie “Enviroment ise. / Hunnused@ulnawiinmaenooudishen Sou Works undies asaviudswrndon river winuiune Page 7 of 26

You might also like