Professional Documents
Culture Documents
1 BSC6900 GU Subracks
The configuration of BSC6900 GU(BM/TC Combined Mode) subracks is shown in the figure
1. The UMTS subrack is the master subrack and configured before the GSM subrack.; The
configuration of BSC6900 GU (BM/TC Separated Mode ) subracks is shown in the figure 2.
The GSM subrack is the master subrack and configured before the UMTS subrack. The
quotation of BSC6900 GU without DPUc/DPUg, the configuration is BM/TC Separated Mode.
3. Fan box (02120370): One piece is required in each subrack. Fan boxes (02120370) can be configured
for subracks (02300562) only.
4. NEBS cabinets (02113210): One or two pieces can be configured. Such cabinets are required by the
Network Equipment Building System (NEBS) certification only.
Caution:
(5) TNUa boards are fixedly inserted in slot 4 and slot 5, SCUa/SCUb boards in slot 6
and slot 7, and GCUa/GCGa boards in slot 12 and slot 13.
(6) DPUb/DPUc/DPUd/DPUe/DPUf/DPUg/NIUa boards are service boards. They may be
installed in both the front half and the rear half of a subrack but in the front half in
precedence.
(7) EIUa, PEUa, AEUa, OIUa, AOUa, AOUc, UOIa, UOIc, POUa, POUc, FG2a, FG2c, FG2d,
GOUa, GOUc and GOUd boards are interface boards. They must be installed in the
rear half subrack.
2.3 No Intermixing
Except DPUb, DPUc/DPUf, DPUd/DPUg, DPUe and NIUa boards, boards in the front half
subrack must not be inserted in the rear half and boards in the rear half subrack must not be
inserted in the front half.
Configuration in One
BOM Name Slot Allocation to Multiple Subracks
Subrack
02238806/
The OMUa or OMUb board is
OMUa/
02238587/ inserted in slots 24–27. The Two or one for each BSC,
OMUb/ 24–27
02237111/ OMUc board is inserted in slot depending on the quotation
OMUc
24 or 25.
03053461
03051117/ SCUa/
6 and 7 Fixed configuration Two for each subrack
03053067 SCUb
Configuration in One
BOM Name Slot Allocation to Multiple Subracks
Subrack
Configuration in One
BOM Name Slot Allocation to Multiple Subracks
Subrack
14–27
(16–23
precedence),
when use for Number of boards per subrack =
03052761 FG2c UMTS mode, From slot 20 to both sides Total number of boards / Number
It can only of subracks
configured in
the slot of 16-
23.
14–27
(16–23
precedence),
when use for Number of boards per subrack =
03052762 GOUc UMTS mode, From slot 20 to both sides Total number of boards / Number
It can only of subracks
configured in
the slot of 16-
23.
14–27
(16–23
precedence),
when use for Number of boards per subrack =
03052760 UOIc UMTS mode, From slot 20 to both sides Total number of boards / Number
It can only of UMTS subracks
configured in
the slot of 16-
23.
03051121 EIUa 14–27 From slot 20 to both sides Number of boards per subrack =
Configuration in One
BOM Name Slot Allocation to Multiple Subracks
Subrack
Optical Transceivers
Transmission Reference
Board Wavelength Type Rate Interface
Distance BOM
Note: The number of optical transceivers is a full configuration as per the number of ports in an
optical interface board:
One optical transceiver is configured in one OIUa board.
At most eight optical transceivers are configured in one UOIc board.
At most four optical transceivers are configured in one UOIa board.
At most four optical transceivers are configured in one AOUc, POUc, GOUc or GOUd
board.
At most two optical transceivers are configured in one AOUa, POUa, or GOUa board.
Note: For an interface board, the same types of optical modules must be used. For two interface
boards working in active/standby mode, the same types of optical modules must be used.
Software code mapping between the host and the OMU board
Version Software Code of the Software Code of the OMU Remarks (OMU Software Code
Host Board Board Delivered in Special Situations)
The following table lists the software codes and the corresponding description of the host board and the
OMU board:
The 05019300 BSC6900 BSC6900 V900R011C00, BSC6900 Host Software & Local Maintenance
host Terminal Software Physical Software Package
board
05010DEY BSC6900,BSC6900 V900R012C00, Host Software & Local Maintenance Terminal
Software
OMU 03053461 PARC,WP11POMUc,Operation and Maintenance Unit (with DOPRA LINUX and Driver
Software Package ) REV:c
02238806 Operation and Maintenance Component,with DOPRA LINUX and Driver Software
Package REV:a
02237111 Operation and Maintenance Component,with SuSE LINUX Enterprise Server and Driver
Software Package
02238586 Operation and Maintenance Component,with Windows Server and Driver Software
Package (Chinese) REV:a
02238587 Operation and Maintenance Component,with Windows Server and Driver Software
02237123 Operation and Maintenance Component,with Windows Server and SQL software (English)
02237127 Operation and Maintenance Component,with Windows Server and SQL software
(Chinese)
Note:
If the interface board is EIUa or OIUa, it is only necessary to replace the POUc boards in
the above figure.
In a TC cabinet, SCUa/SCUb, TNUa, and DPUc/DPUf boards are mandatory.
SCUa/ SCUb and TNUa boards are inserted in fixed slots. DPUc/ DPUf boards are inserted
in the front slots in precedence and in the rear slots when the front slots are all used.
Interface boards EIUa, OIUa and POUc must be inserted in rear slots.
7 Remarks