APPLIED CALIBRATION & /\ INSTRUMENTATION SYSTEM INC. UNIT 201 IHG BLDG. #7 BAGONG ANYO ST., BRGY, ‘AB STA LUCIA, 1608 PASIG CITY 2B ACCREDITED. Tel No: 7288.5825/ 8401-9145 TIN: 246-120-199.000 ‘CALIBRATION LABORATORY mal acai caitratongamailcom PNS ISONEC 17025:2008, tA-2000-120¢ CERTIFICATE OF CALIBRATION LOXON PHILIPPINES, INC. LPI Centre 324 Capt. Henry Javier St. Oranbo Pasig City Certificate No: 04-210386-H002 Date: Apr-28-2021 Equipment Under Calibration: Description ‘Analog Multtitester Date Received ‘Apr-16-2021 Manufacturer's Name Sanwa Date Calibrated ‘Apr-23-2021 Model No, YX360TRF ™ Date Due ‘Apr-23-2022 Serial No. 19121302238 Ambient Temperature 233°C Relative Humidity 55 + 15 %RH Calibration Method: This Equipment was calibrated in accordance with ACAISI's CMe-001 Metrological Traceability: This Equipment was calibrated using reference standard traceable to S! Units as maintained by NIST, USA; PTB, Germany; NPL, United Kingdom; through FLUKE Corporation, USA. Reference Standar nt ing Calibration | Standard Equipment Serial No Certica Multi-Product Calibrator (E-060) 4730803, 8032012 Sep-19-2021 Calibration Results: ‘The results of this calibration are shown on page 2 of this certificate. Reporting Statements of Conformity ( Decision Rule ): The results reported in this certificate including the expanded measurement uncertainty are in compliance with the Accuracy Specification of this Equipment during calibration. The result with Asterisk (*) marks denotes that out of its Accuracy Specification. Opinions and Interpretations: 1. The Unit Under Calibration test cable were used during Calibration. 2. The calibration due date (*) of this Equipment was recommended by the customer according to their calibration program. 3. The results reported in this certificate were the average value of five (5) trials, and refer to the condition of the Equipment on the date of calibration and carry no implication regarding the long-term stability of the Equipment. If this Equipment has been modified and developed inconsistent reading, the result may not be valid and the Equipment will require re-calibration, 4, The reported expanded measurement uncertainty is stated as the standard uncertainty of measurement multiplied by a coverage factor k, corresponding to a coverage probability of approximately 95 %, and has been carried out in accordance with principles in the Evaluation of Measurement Data ~ Guide to the Expression of Uncertainty in Measurement, JCGM 100:2008 ( GUM 1995 with minor corrections). 5. The user should evaluate and determine the suitabilty of this Equipment for its intended use. Calibrated by. Approved by: Cigus Leosi}aumsra Approved Signatory Page 1 of2 This laboratory is accredited by the Philippine Accreditation Bureau (PAB), DTI, Philippines in accordance with PNS ISO/IEC 117025:2005. This report must not be reproduced except in fll, without written permission from ACAIS! APPLIED CALIBRATION & /\ INSTRUMENTATION SYSTEM INC. Veal nr 201 wc 6.06 #7 BAGONG ANYOST, BRGY STA. LUCIA, 1608 PASIG CITY VENER] Se 80-7222 5823/2201 Email acai cairn com 45. TIN: 246-120-10-000 ae PAB ACCREDITED CALIBRATION LABORATORY 'PNS ISONEC 17025:2005 Cez00e-1290 CERTIFICATE OF CALIBRATION LOXON PHILIPPINES, INC. LPI Centre 324 Capt. Henry Javier St. Oranbo Pasig City Certifeate No. 04-210386-H002 Date: Apr-28-2021 Calibration Results: Expanded Range/ | Standard Equipment | Unit Under Calibration | curac Coverage y | Measurement Function Applied Value Indication Coma’ | Feconk 7. DC Voltage 25V 124V ‘Ooi1V 10V 4a2V #3 % agaist [——~pousv | 1.98 246V 023V 4.23 mA £3% against [__0011 mA ie 12:3mA full scale O1tmA 70 700 0110 100 + 1080 0230 1.96 soo | + 1040 250 | x70 100 100 110 1000 3000 3% of arc 110 1.96 4.000 0 4.0000 28.0 X 1008 200 0 200 0 410 10000 1000.0 110 1.96 10.0000 100000 283.0 ZAC Voltage (60H2) — —— 496 +£4% against 488 250 V_ 75 "av ese. Calibrated by: Approved by. jim L. HSS Leo seaonsra Approved Signatory Page 202 ‘This laboratory is accredited by the Philippine Accreditation Bureau (PAB), DTI, Philippines in accordance with PNS ISO/EC. 17025:2008 This report must not be reproduced except in full, without written permission from ACAIS|

You might also like