Professional Documents
Culture Documents
: FSN120008
MARINE Date : 7 Mar, 2012
Departmen : Network and communication group
Engineering Department
Marine Electronics Division
Person in-charge: S. Kuromori, Manager
Service News
✓ Information Request for work
4 Details
1) Phenomenon of problem
2) Information or countermeasures
Transistors TR4 and TR5 (2SC2540) for drive amp stage were discontinued, therefore they were
changed to the VHB40-12F5 in 2006.
The insulation sheet that used for 2SC2540 is unnecessary cause VHB40-12F5 is insulated
structure.
Install the new CAH-1960 without the insulation sheet when replacing the unit.
Even if the insulation sheet is installed with the new CAH-1960, there is no problem.
1/1