Table of Contents
1. Overview:............................................................................................................................................. 2
2. Appearance ........................................................................................................................................... 2
2.1. Front panel: ........................................................................................................................................ 2
2.1. Rear panel: ......................................................................................................................................... 2
3. Interfaces:.............................................................................................................................................. 3
3.1. Console: ............................................................................................................................................. 3
3.2. Telnet: ................................................................................................................................................ 3
4. Power supply interface:......................................................................................................................... 3
5. Interface definitions: ............................................................................................................................. 3
5.1 Console definition of Hyper Terminal: ............................................................................................... 3
6. Installation: ........................................................................................................................................... 4
6.1. Unpacking: ......................................................................................................................................... 4
6.2. Configuring the FABIO-1CX: ........................................................................................................... 4
7. TEAMLINK FABIO-1CX Menu Handling Procedure......................................................................... 5
8. Local Ethernet Configuration................................................................................................................ 6
9. E&M Configuration: ............................................................................................................................. 8
10. Clock Configuration: .......................................................................................................................... 8
11. QUAD Configuration.......................................................................................................................... 9
12. Status of the FABIO-1CX ................................................................................................................... 9
13. Quad Status Menu ............................................................................................................................. 10
14. Diagnostic Menu ............................................................................................................................... 11
15.System Configurations ....................................................................................................................... 12
16. Loading the Default Configurations or Saving the Configurations .................................................. 12
17. RTC Configurations ........................................................................................................................ 13
18. Log File ............................................................................................................................................ 14
19. Log File Clear ................................................................................................................................... 14
20. Reboot Menu.................................................................................................................................... 15
21. FABIO-1CX-SUB-2E&M-QUAD ................................................................................................... 16
21. 1. E&M Interfaces:............................................................................................................................ 16
21. 2. QUAD Interfaces: ......................................................................................................................... 16
22. Cable Connections ............................................................................................................................ 16
22.1. Connecting the Power and earth .................................................................................................... 16
22.2. Connecting to DC Power ............................................................................................................... 16
Address: .................................................................................................................................................. 17

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 1


FABIO-1CX

1. Overview:

Teamlink FABIO-1CX allows user devices with ITU-T V.21 or V.23 compatible communication
interface to connect to an E1 channel. Its built–in Copper Bypass facility with automatic changeover
allows enhanced reliability for critical applications, by automatically diverting V.21/V.23 traffic to a
standby Copper Circuit in case the E1 link fails or if the FABIO-1CX units gets powered off for some
reason. Extensive facilities for critical event reporting aid in prompt addressing of faults, and further
enhance the products suitability for critical applications. Available with either 48 VDC or 24 VDC power
input, FABIO-1CX is ideal for use in Axle Counter interconnection applications

FABIO-1CX is a modular integrated Access TDM multiplexer with 512 x 512 cross connect ability,
which integrates multiple dedicated data, voice and LAN channels over multiple main (network) links. It
can provide maximum 1 E1’s and 2W/4W E&M, Quad Cable Ports, RS232/V.24, ETH capacity for
accessing and transmission with cross-connect capacity is 512×512 64K. It provides full range of voice
and digital data services to subscribers located at different locations require to interconnect and establish a
voice and data network over E1 link.

FABIO-1CX enables carriers to successfully deploy bundled services and Internet access. The integration
of a broad range of services makes FABIO-1CX a cost-effective access device, with reduced deployment
and maintenance costs. The equipment conforms to international standards, ensuring compatibility in
multi-vendor environments worldwide.

FABIO-1CX is designed to carry Various Original Equipment Manufacturer’s Digital Axle Circuits over
optical fiber (STM).

2. Appearance
2.1. Front panel:

2.1. Rear panel:

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 2


FABIO-1CX

3. Interfaces:
3.1. Console:

The Console interface is used to connect the PC through the configuration cable for local configuration,
the baud rate of which is 115200 Baud.

3.2. Telnet:

The Telnet interface is used to access the network through the Ethernet cable for remote configuration.

4. Power supply interface:

DC power supply interfaces are supported. The DC voltage range is between –36V ~ -72V DC.

5. Interface definitions:
5.1 Console definition of Hyper Terminal:
CONSOLE interface for Hyper Terminal is RJ45 interface and standard RS232 voltage :
Signaling and Pin-outs:
12345678

Pin number Signal Explanation

3 RXD Rx of FABIO -1CX

6 TXD Tx of FABIO -1CX

4 GND Ground of FABIO -1CX

Definition of balanced FABIO-1CX-1E1 E1 interface:

Balanced E1 interface is RJ45 interface, and the Signaling and Pin-outs are:

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 3


FABIO-1CX

Pin number Signal Explanation

1 OUT+ Positive Tx of balanced E1 interface

2 OUT- Negative Tx of balanced E1 interface

4 IN+ Positive Rx of balanced E1 interface

5 IN- Negative Rx of balanced E1 interface

6. Installation:
6.1. Unpacking:

The FABIO-1CX will provides the all accessories for connecting like console cables, RS232 cables for
connecting the console port and the Power cables for connecting the Unit,

6.2. Configuring the FABIO-1CX:


 Connect the RS232 Console cable to the FABIO-1CX in the RJ45 Socket and other end DB9
connector in the Host PC
 Open the HyperTerminal or any other Terminal Emulation Like Putty Tera term
 Keep the VT100 Emulation for Proper display of the Menus.
 Press Enter Key after the system is Booted.
 Give the Login and password
 Login is : root
 Default Password is : root

Configuration through the Telnet Interface

To Configure the TEAMLINK FABIO-1CX through the Telnet client Interface we need to configure the
IP Address, Net mask, Gateway Address By default the TEAMLINK FABIO-1CX is having the IP
Address 192.168.1.254 net mask 255.255.255.0 and Gateway Address 192.168.1.1, According to the
Network IP addresses configure the Equipment for configuration through the Telnet Interface, Ping the IP
address configured and check the healthy condition, Once the Ping Response is coming then Open the
Telnet Session that is like the RS232 Menu we will get on the screen .

FABIO-1CX Booting Display

--------------------------------------------------------------------------
TEAMLINK FABIO-1CX

--------------------------------------------------------------------------
Login : root
Password:****

Give Login name as root and the password as root default for getting the menus, Once the main menu is
came check for the basic configurations like LAN Configuration, Gateway Address configuration , Net
mask for the Local and configure each terminal ports basic configurations
Below is the Login screen from RS232 Console Port.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 4


FABIO-1CX

7. TEAMLINK FABIO-1CX Menu Handling Procedure

Each Menu starting from the configuration through the Reset or logout the Equipment is having the
simple Display options It will have the numeric 1, 2, 3 etc select the Appropriate Menu by pressing the
Option followed by the Enter key. Once You Enter the Next menu If we required to come back from any
menu simply press character b and enter It will come back to the previous menu.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 5


FABIO-1CX

8. Local Ethernet Configuration

For Basic Configuration of the Equipment Select the Configuration menu in that Configuration select the
LAN Config Menu, Once You Enter into the LAN Configuration Menu, We have to configure the
Following parameters,

Local IP address: The IP address of the FABIO-1CX Server which is going to connect the Local
network and Assign the Gateway address also for Getting the Connectivity through the Local Gateway
Router for the Other Hosts,

Local Subnet mask: The subnet mask of the IP address by default is 255.255.255.0 If required to change
the according to the network then we need to change the Subnet mask accordingly,

Gateway Address: The Gateway Address of the FABIO-1CX is the Address which is required to Route
through the Default Router for connecting the Remote Hosts.

Below Screen shot displays the Configuration Menu.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 6


FABIO-1CX

Once the Basic LAN Configuration is completed then we have to check the E1 configuration through the
Config Menu.

It will displays the Parameters.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 7


FABIO-1CX

9. E&M Configuration:

10. Clock Configuration:

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 8


FABIO-1CX

11. QUAD Configuration

12. Status of the FABIO-1CX

The TEAMLINK FABIO-1CX is having the status menus for getting the status of the E1 status as well as
the Quad status.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 9


FABIO-1CX

Select the Option 1 For Entering into the E1 Status or press 2 for enter into the Quad Status

Press ‘b’ to come back to the Previous Menu, All the Menus are displayed in the Proper manner in which
we do not have any problem for checking in which menu we are having, The Top of the screen of the
FABIO-1CX in each and Every Menu will displays in which menu we are having.

According to that display we can go further or come back according to the user requirements.

13. Quad Status Menu

Select the Option 2 for Getting the status of the Quad Status below snap shot of the FABIO-1CX will
shows the quad1,quad2 Rx/Tx status.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 10


FABIO-1CX

14. Diagnostic Menu

The TEAMLINK FABIO-1CX is having the Diagnostic menus for getting the loop Type of the E1 Port.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 11


FABIO-1CX

15.System Configurations

System Menu in the Main Menu Will Provides the Following Options

1. Load Default Configuration


2. Save Configuration
3. Change Username
4. Change Password
5. RTC Configuration
6. Log file
7. Log file clear

16. Loading the Default Configurations or Saving the Configurations

If the Equipment is having any problem while connecting to the Remote host or any host table problems
load the default configuration , the factory default configuration will be loaded with all the Terminal Ports
disabled, and 8 N 1 formatted 115200kbps speeds UART selection and the Terminal Ports are configured
with the switched mode operation.

After Loading the default configuration reset the FABIO-1CX and change the setting as per the user
requirements, Once the changes have been dome then go the save Configuration menu and save changes,
The TEAMLINK FABIO-1CX will ask for the confirmation save changes yes or no press
y for the Yes or If we do not want to save the changes in the non Volatile Memory Press n to Go back , If
the changes are not saved will be loaded with the old values once the FABIO-1CX is Rebooted.

In the Same System Menu user can Go the Reset Terminal Ports menu for the Resetting the Terminal
ports, After the Reset is applied The Terminal will ask for confirmation yes or No , Press Y for the Reset
or N to go back to the Previous Menu, If the user pressed Y button then the corresponding UART will be

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 12


FABIO-1CX

reset and Reloaded or Reinitialized with the configuration, Once the Reset is successful then the
Terminal Is Ready for the Connection either implicit or Switched mode of Operation

The Above Snap shot is having the Confirmation message for loading the default configurations

17. RTC Configurations

If required to change the date and time Below Screen shot displays the RTC Configuration.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 13


FABIO-1CX

18. Log File

TEAMLINK FABIO-1CX will records the events Link E1 UP, E1 DOWN, QUAD UP, QUAD DOWN
conditions in the flash so the even the Power Goes off also we can monitor the events after the Power
comes.
Select the Option 6 for Getting the status of the Log Status below snap shot of the FABIO-1CX will
shows the port status(E1,Quad).

19. Log File Clear

If required to Clear the LogFile Select the Option 7 for Getting the Log File Clear.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 14


FABIO-1CX

20. Reboot Menu

The Above Snap shot is having the Reboot message for system Reboot.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 15


FABIO-1CX

21. FABIO-1CX-SUB-2E&M-QUAD
21. 1. E&M Interfaces:

The interface on the FABIO-1CX-SUB-2E&M adopts the RJ45 female connector.

RJ45 PIN E&M channel Description

 4-wire: send audio A


5
 2-wire: idle
 4-wire: send audio B
6
 2-wire: idle
1 to 2
 4-wire: receive audio A
3
 2-wire: receive/send audio A
 4-wire: receive audio B
4
 2-wire: receive/send audio B

21. 2. QUAD Interfaces:

The interface on the FABIO-1CX-SUB-2QUAD adopts the RJ45 female connector.

RJ45 PIN QUAD channel Description

 4-wire: receive audio A


3
 2-wire: idle
 4-wire: receive audio B
4
 2-wire: idle
1 to 2
 4-wire: send audio B
1
 2-wire: receive/send audio A
 4-wire: send audio A
2
 2-wire: receive/send audio B

22. Cable Connections


22.1. Connecting the Power and earth

FABIO-1CX is equipped with DC power supply. DC power is supplied to FABIO-1CX via a standard
power input connector on the rear panel. Ensure proper ear thing connection.

22.2. Connecting to DC Power

DC power is supplied to FABIO-1CX via a compatible DC cable for attaching -48V DC power
supply lines. While connecting to the DC power mains, the polarity needs to be taken care as per the
indications provided on the DC cable.
The DC power cord is provided along with the unit.

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 16


FABIO-1CX

Address:

Customer Support Dept., TEAM ENGINEERS,


Plot No. A-1/2/A, Industrial Park, IDA Uppal,
HYDERABAD – 500 039. T.S., INDIA.
Tel No. +91 40 – 2720 4730/731, 6528 6274
Mobile: 9949150099 / 9347522062
Fax:+91-40-27204731
Email: hyd1_lvreddy@sancharnet.in
URL: www.teamengineers.in

TEAM ENGINEERS Advance Technologies India (P).Ltd. Page 17

You might also like