Part 3
002-518-3e-01.14
Foreword

Foreword
This manual applies to Single-Force/Displacement Measur-
ing System DMF-P A300 NCF Typ 4734A… for NC Joining
Systems and DMF-P A310 Universal Type 4740A… .

The instruction manual must be kept on hand for future


use, and must be available at the site of implementation of
the NC joining module, as needed.

The specifications in this manual can change at any time


without prior notification. Kistler reserves the right to im-
prove and to change the product for the purpose of tech-
nical progress without the obligation to inform persons and
organizations as the result of such changes.

Original language of these operating instructions: German

© 2004 ... 2014 Kistler Group. All rights reserved.

Kistler Group
Eulachstrasse 22
8408 Winterthur
Switzerland
phone +41 52 224 11 11
fax +41 52 224 14 14
info@kistler.com
www.kistler.com

002-518-3e-01.14 Seite 1
Contents

Contents

1.  Introduction ................................................................................................................................... 5 


1.1  8BSafety Instructions ................................................................................................................ 6 
1.2  9BSymbols Used. ...................................................................................................................... 6 
1.3  10BIntended Use ........................................................................................................................ 6 
1.4  1BGeneral Safety Instructions ................................................................................................... 7 

2.  System Description ........................................................................................................................ 9 


2.1  DMF-P A300 NCF Type 4734A… ........................................................................................ 9 
2.1.1  General Function ..................................................................................................... 9 
2.1.2  Schematic Diagram using IndraDrive and DMF-P A300 NCF................................. 11 
2.1.3  Schematic Diagram using EcoDrive and DMF-P A300 NCF ................................... 12 
2.1.4  Front View and Description of Position DMF-P A300 NCF Type 4734A… ............ 13 
2.1.5  Rear View and Description of Positions DMF-P A300 NCF Type 4734A… ............ 14 
2.2  DMF-P A310 Universal Type 4740A…............................................................................... 15 
2.2.1  General Function ................................................................................................... 15 
2.3  Schematic Diagram using IndraDrive and DMF-P A310 Universal ...................................... 16 
2.3.1  Front View an Description of Positions DMF-P A310 Universal ............................. 17 
2.3.2  Rear View and Description of Positions DMF-P A310 Universal ............................ 18 

3.  Joining/Measurement .................................................................................................................. 19 


3.1  DMF-P A300 NCF Type 4734A… ...................................................................................... 19 
3.1.1  Standard Joining Operation (Press Parameter Menu: Short) .................................. 20 
3.1.2  Extended Joining Operation (Press Parameter Menu: Long) .................................. 22 
3.2  DMF-P A310 Universal Type 4740A…............................................................................... 24 
3.2.1  Standard Joining Sequence (Press parameter menu: Short).................................... 25 
3.2.2  Extended Joining Sequence (Press Parameter Menu: Long) ................................... 27 
3.3  19BMeasurement of Force (y) via Displacement (x) y = f(x) ..................................................... 29 
3.4  20BMeasurement During Forward and Backward Movement .................................................. 30 
3.5  21BMeasurement with Compressive and Traction Forces ......................................................... 31 
3.6  2BMeasurement of Force (y) Over a Range of Time (t) y = f(t) .............................................. 32 

4.  Control and Signals ...................................................................................................................... 33 


4.1  DMF-P A300 NCF Type 4734A… ...................................................................................... 33 
4.1.1  Standard Measurement Process ............................................................................. 33 
4.1.2  Test Sequence (Self Test) ....................................................................................... 35 
4.2  DMF-P A310 Universal Type 4740A…............................................................................... 36 
4.2.1  Standard impulse diagram, joining process ............................................................ 36 
4.2.2  System Test Impulse Diagram ................................................................................ 36 

5.  Operation..................................................................................................................................... 37 


5.1  25BStatus Line/Input/Soft Key-Functions ................................................................................. 37 
5.1.1  39BStatus Line ............................................................................................................. 37 
5.1.2  40BSoft Key – Function (Function Keys F1 … F7) ........................................................ 37 
5.1.3  Input of Values ...................................................................................................... 40 
5.1.3.1  Numeric Values ...................................................................................... 40 
5.1.3.2  Alphanumeric Value ............................................................................... 40 
5.1.3.3  Input with an External Keyboard ............................................................ 41 
5.1.4  42BSpecial Inputs ........................................................................................................ 41 

Page 2 002-518-3e-01.14
Introduction

5.2  26BMenu Structure DMF-P A300 NCF Type 4734A… ............................................................. 42 
5.3  26BMenu Structure DMF-P A310 Universal Type 4740A… ...................................................... 43 
5.4  Difference between DMF-P A300 NCF Type 4734A…/DMF-P A310 Universal Type
4740A… ............................................................................................................................. 44 

6.  Evaluation of the Measured Values .............................................................................................. 45 


6.1  28BEvaluation Methods ............................................................................................................ 45 
6.2  29BTolerance Windows ............................................................................................................ 46 
6.2.1  43BOverview Table ...................................................................................................... 46 
6.2.2  4BWindow Type 0; Displacement Window Right ....................................................... 50 
6.2.3  45BWindow Type 0; Force Window Maximum ............................................................ 52 
6.2.4  46BWindow Type 1; Joining Window (Live Function) .................................................. 54 
6.2.5  47BWindow Type 2; Limitation Window at the Bottom Right ...................................... 58 
6.2.6  48BWindow Type 3; Start Position Window, Limitation at the Top-Left ...................... 61 
6.2.7  49BWindow Type 4: Snap Window, Peak Window at the Top .................................... 64 
6.2.8  50BWindow Type 5; Rising Window ............................................................................ 68 
6.2.9  51BWindow Type 6; Average Value Window .............................................................. 71 
6.2.10  52BWindow Type 7; Limitation Window Top-Right ..................................................... 73 
6.2.11  53BWindow Type 8; End Window at the Top .............................................................. 76 
6.2.12  54BWindow Type 9; Start Window at the Top ............................................................. 79 
6.2.13  5BWindow Type 10: Snap Window, Peak Window at the Bottom ............................. 82 
6.2.14  56BWindow Type 11; End Window at the Bottom....................................................... 85 
6.2.15  57BWindow Type 12; Start Window at the Bottom ..................................................... 88 
6.2.16  58BWindow Type 13; Reverse Window – Right ........................................................... 91 
6.2.17  59BWindow Type 14; Reverse Window – Left ............................................................. 94 
6.2.18  60BWindow Type 15; Limitation Window at the Bottom-Left ..................................... 97 
6.2.19  Window Type 16; Displacement Window Left .....................................................100 
6.2.20  62BWindow Type 17; Force Window Minimum ........................................................102 
6.2.21  63BWindow Type 18; Combined Start-End-Window .................................................103 
6.2.22  64BWindow Type 20; Speed Window........................................................................108 
6.2.23  65BWindow Type 21; reserved ..................................................................................108 
6.2.24  6BWindow Type 22; reserved ..................................................................................108 
6.2.25  67BWindow Type 23; Gradient Window....................................................................109 
6.2.25.1  108BGradient Window for OK/NOK Evaluation .......................................... 109 
6.2.25.2  109BGradient Window for Online-Trigger (YTE) ......................................... 110 
6.2.26  68BWindow Type 24; Breakpoint Window ................................................................112 
6.2.27  Window Type 25; Reserved .................................................................................116 
6.2.28  Window Type 26; Reserved .................................................................................116 
6.2.29  71BWindow Type 27; Localized Displacement Monitoring.........................................116 
6.2.30  72BWindow Type 28; Localized Force Monitoring .....................................................120 
6.2.31  73BWindow Type 29; Restricted Area ........................................................................123 
6.2.32  74BWindow Type 30; MinPosition .............................................................................125 
6.2.33  75BWindow Type 31; MaxPosition ............................................................................127 
6.2.34  76BWindow Type 32; Energy Window ......................................................................128 
6.3  30BPresentation of Measured Values ......................................................................................130 
6.3.1  7BMenu Measured Values: Table .............................................................................130 
6.3.2  78BMenu Diagram .....................................................................................................132 
6.3.3  79BDiagram Menu in the Cursor and Zoom Mode ....................................................134 

7.  Programming and Parameter Entry .............................................................................................136 


7.1  31BMeasuring Program ..........................................................................................................137 
7.1.1  80BMenu Input of Set Points .....................................................................................137 
7.1.2  81BParameter Menu ..................................................................................................150 
7.1.2.1  Menu Joining Parameter Standard Joining Operation "Short" ............. 157 
7.1.2.2  Menu Joining Parameter Extended Joining Operation "Long" ............. 159 

002-518-3e-01.14 Seite 3
Contents

7.1.2.3  Global Joining Parameter Position Sets 60 … 63 .................................. 162 


7.1.2.4  Menu Joining-Parameter Force Controlling .......................................... 162 
7.1.2.5  Menu Joining Parameter Deformation Compensation .......................... 163 
7.1.3  Joining Parameter DMF-P A310 Universal Type 4740A… ................................... 165 
7.1.3.1  Joining parameters menu, standard joining process “short” ................. 165 
7.1.3.2  Joining Parameters Menu, Expanded Joining Process “long” ............... 166 
7.1.3.3  Joining Parameters Menu, Force Regulation......................................... 169 
7.1.3.4  Joining Parameters Menu, Compensation for Process Compression ..... 170 
7.1.4  87BEditing Tolerance Windows Graphically ............................................................... 172 
7.1.5  8BCopying of Measuring Programs ......................................................................... 175 
7.2  32BSystem Settings ................................................................................................................ 177 
7.2.1  89BMenu System Setup 1 ......................................................................................... 177 
7.2.2  90BMenu Data Transmit RS-232C ............................................................................ 182 
7.2.3  91BMenu System Setup 3 ......................................................................................... 183 
7.2.4  92BMenu System Setup 4 ......................................................................................... 185 
7.2.4.1  DMF-P A300 NCF Type 4734A… ........................................................ 185 
7.2.4.2  Transmission Mode, Positioning Sets – serial for DMF-P A300 NCF Type
4734A… .............................................................................................. 187 
7.2.4.3  DMF-P A310 Universal Type 4740A… ................................................ 191 
7.3  Calibration........................................................................................................................ 193 
7.3.1  94BCalibration Menu ................................................................................................ 193 
7.3.2  95BMenu Calibration of the X-axis Absolutely SSI ..................................................... 194 
7.3.3  96BMenu Calibration of the X-Axis Incremental ........................................................ 197 
7.3.4  97BMenu Calibration of the Y-Axis Active 0 ... 10 V ................................................. 200 
7.3.5  98BMenu Calibrating the Y-Axis Strain Gage ............................................................ 202 
7.3.6  9BMenu Calibration of Y-Axis Piezo ........................................................................ 204 
7.3.7  Calibration Menu for the Y Axis with Two-Range Loading Amplifier ................... 206 
7.4  34BControl and Service .......................................................................................................... 209 
7.4.1  10BService Menu ...................................................................................................... 209 
7.5  35BDocumentation and Statistic............................................................................................. 211 
7.5.1  10BDocumentation Menu ......................................................................................... 211 
7.5.2  102BMenu Error Messages .......................................................................................... 212 
7.5.3  103BPrintout Menu ..................................................................................................... 215 
7.5.4  104BProtocol Menu .................................................................................................... 216 
7.5.5  105BMenu Protocol Memory ...................................................................................... 219 
7.5.6  106BMenu Diagram Memory ...................................................................................... 220 
7.5.7  107BStatistic Menu ..................................................................................................... 222 
7.5.7.1  Submenu Histogram ............................................................................ 223 

8.  Manual Control with DMF-P A310 Universal Type 4740A... ..................................................... 227 
8.1  Control Menu .................................................................................................................. 228 
8.1.1  Service Menu (jog mode) .................................................................................... 230 
8.1.2  Move Menu (stepping mode) .............................................................................. 232 
8.1.3  Automatic Menu ................................................................................................. 234 

9.  Informations............................................................................................................................... 236 


9.1  36BPutting into Operation Check List .................................................................................... 236 
9.2  37BTechnical Terms-Synonyms .............................................................................................. 237 

10.  38BIndex .......................................................................................................................................... 238 

Total Pages 242

Page 4 002-518-3e-01.14
Introduction

1. Introduction
Please take the time to thoroughly read this instruction
manual. It will help you with the installation, maintenance,
and use of this product.

To the extent permitted by law Kistler does not accept any


liability if this instruction manual is not followed or prod-
ucts other than those listed under Accessories are used.

Kistler offers a wide range of products for use in measuring


technology:
 Piezoelectric sensors for measuring force, torque, strain,
pressure, acceleration, shock, vibration and acoustic-
emission
 Strain gage sensor systems for measuring force and
torque
 Piezoresistive pressure sensors and transmitters
 Signal conditioners, indicators and calibrators
 Electronic control and monitoring systems as well as
software for specific measurement applications
 Data transmission modules (telemetry)
 Electromechanical NC joining modules and force-
displacement monitors
 Test stand systems for electric motors and gear units for
laboratory, manufacturing, and quality assurance

Kistler also develops and produces measuring solutions for


the application fields engines, vehicles, manufacturing,
plastics and biomechanics sectors.

Our product and application brochures will provide you


with an overview of our product range. Detailed data
sheets are available for almost all products.

If you need additional help beyond what can be found ei-


ther on-line or in this manual, please contact Kistler's ex-
tensive support organization.

002-518-3e-01.14 Seite 5
Contents

1.1 Safety Instructions


8B

The device left the factory in faultless, technically safe con-


dition. To maintain this condition and to ensure safe opera-
tion, users must comply with the instructions and warnings
contained in this manual or imprinted on the device.

Report any transport damage to the freight forwarder


and to Kistler.

1.2 Symbols Used.


9B

DANGER!
This symbol warns of a danger zone!
It is displayed on all safety warnings where danger to life
and limb for the operator or other personnel exists.
Strictly comply with these instructions and act with par-
ticular care in these cases. Pass all safety instructions on
to other users

CAUTION!
This symbol indicates instructions, which if not complied
with, can cause damage to the NC joining module or to
other machines and systems.

NOTE!
This symbol indicates instructions that enable more ef-
fective and more economic use of the NC joining mod-
ule.

1.3 Intended Use


10B

The force-displacement measuring device is designed for


control, measurement, and analysis of joining processes
with NC joining modules.

When handling the force-displacement measuring device


always comply with the instructions specified in the man-
ual of the NC joining module Kistler OI-No. 1558 Part 1.

Page 6 002-518-3e-01.14
Introduction

1.4 General Safety Instructions


1B

Read the instruction manual prior to commissioning, main-


taining, or repairing the system. Strictly comply with all
safety instructions.
Keep the instruction manual on hand for personnel at the
implementation site of the force-displacement measuring
device.

Tasks and programming on the force-displacement meas-


uring device should only be performed by personnel who
have read and understood these operating instructions.

Kistler assumes no liability for personal injury or material


damage that occurs through failure to comply with the
safety instructions, or violation of the duty of care. This
applies for handling, operation, for care and maintenance,
or for repair of the NC joining module, even if there is no
special reference to this duty of care in the operating and
maintenance instructions.

Only trained, qualified electricians should perform tasks


that have anything to do with the electrical system of the
NC joining system and the force-displacement measuring
device. If tasks must be performed on energized parts, a
second person who can disconnect the power supply in
an emergency must also be present.

The valid directives, standards, and accident prevention


regulations must be complied with. Failure to comply
with these directives, standards, and accident prevention
regulations can cause severe injury or material damage!
Only operate the NC joining module with force-
displacement measuring device if safe operation is possi-
ble.
Kistler shall not be liable for damage that occurs due to
non-compliance with these regulations.

As long as the device is connected, energized parts or


moving parts can be exposed when opening or removing
covers.
Only a specialist should perform maintenance and repair
tasks on energized, open devices.
Only work with the force-displacement measuring device
unter the specified operating conditions, e. g. ambient
temperature. Protect the device from dust an mechanical
stress such as shock and vibrations.
Avoid high humidity and temperature changes that result
in condensation.

002-518-3e-01.14 Seite 7
Contents

Suitable safety measures such as two-hand start, protec-


tive grilles, etc. must be provided by the manufacturer of
the ready-to-use machine or system, and these safety
measures must be integrated in the control circuit in
accordance with the determined risk category. The safety
circuit must be activated when using the NC joining unit.
EMERGENCY STOP switches must be connected as speci-
fied in the safety and wiring insturctions of the servo
controller.
The valid directives, standards, and accident prevention
regulations must be complied with.
Failure to comply with these directives, standards, and
accident prevention regulations can cause severe injury or
material damage!
The system cannot be used in plant areas that are subject
to explosion hazard.
When working in the traverse range of the plunger the
main switch for the overall machine must be switched off
and you must ensure that the power unit of the servo
controller is switched off.

The safety requirements imposed on the overall machine


must be defined by the machine manufacturer who speci-
fies the manufacturing concept – automatic stations, man-
ual workstation, automatic assembly, manual assembly –
with the plant operator. These conditions will then serve as
the basis of the safety concept that is required for the plant
or parts of the plant.
Fitting the joining units with safety components – brakes,
speed monitor, safety switch devices, – and the integration
of these components in the safety concept will then be
specified on the basis of the required hazard analysis. Op-
erating the units with bypassed protective devices is strictly
prohibited. If for technical reasons operators must be pre-
sent occasionally or constantly in the danger zone, the ma-
chine equipment must be part of a safety concept that is
suitable for this mode of operation.

You must ensure that with the joining units without brake,
the tool weight does not exceed the limits defined by
Kistler Lorch GmbH. The permissible weights are provided
in the data sheets or the operating instructions.

Additional instructions are provided in the documentation


of the servo controller, see the documentation CD!

Page 8 002-518-3e-01.14
System Description

2. System Description

2.1 DMF-P A300 NCF Type 4734A…

2.1.1 General Function


The single-channel force/displacement measuring system
Type 4734A… DMF-P A300 NCF was specially developed
for the deployment in facilities and systems with our elec-
tro mechanical NC joining systems NCF, NCFH, NCFN,
NCFT and NCFS. The firmware was upgraded so that set
values can be managed and transmitted to the servo con-
troller of Bosch Rexroth (Ecodrive, Indradrive).
The joining monitoring, as well as parameterisation, visuali-
sation and evaluation of the process are done via the sin-
gle-channel force/displacement measuring system Type
4734A… DMF-P A300 NCF. The conditioning of the signal
of both sensors is executed in the Type 4734A… DMF-P
A300 NCF. It is suitable for the deployment in automatic
production lines as well as for manual workstations.
Driving of the spindle is effected by means of an electroni-
cally commutated AC servo motor, which is activated by
one of the mentioned servo controllers. The monitoring of
the traversing area of the spindle can be parameterised in
the servo controller.
An SPS is necessary for controlling the operation.

Advantages
 Forward-backward measurement
 Traction-compression applications
 Possibility for 4-quadrant measurement
 32 nominal values
 8 evaluation functions/window per nominal value
 Multilingual menu
 Additional window types: hysteresis, breakpoint, gradi-
ent,
 Speed, selective teach-in operation
 Online- and offline evaluations
 Statistics with protocol functions
 Logging of measurement results (I-P.M., Q-DAS, csv, txt, ...)
 Self monitoring and diagnosis
 Ethernet 10/100 MBit/s for networking
 Fieldbus interfaces (optional)
 PS/2 keyboard connection for simple operation
 Web server for visualization, modification and filing as
well as remote-control via PC by Ethernet
 Master sample/master check

002-518-3e-01.14 Seite 9
Contents

In addition to the standard sensors (force and displace-


ment), which are integrated in the joining unit, virtually
any other external sensor can be connected.
For a detailed description of the servo controller, drive
and its parameterisation please refer to the respective
optional supplementary instruction manual.

Page 10 002-518-3e-01.14
System Description

2.1.2 Schematic Diagram using IndraDrive and DMF-P A300 NCF

System NCF (H) (N) (S) (B) (T)


User/Control

PLC
K1 Presse 2.4 Linie 2/541r Sys: OK

100 kN5 4

P0 3
Example programs
Status for S7 available
1
2
Profibus
SA Control Profinet
25 00 mm

Tab Curs Serv Zur Sollw Kalib Doku

Parallel interface
Profibus

SSI-Signal
(Absolute encoder)

Status
Control

Force Signal Quick stop Programming

Actual analog
value of force

Feedback

Motor

Description of device interfaces see:


Operating instruction DMF-P A300 NCF Type 4734A...
DMF-P A310 Universal Type 4740A... No. 002-518 Part 2
Interface and Documentation Bosch Rexroth IndraDrive

002-518-3e-01.14 Seite 11
Contents

2.1.3 Schematic Diagram using EcoDrive and DMF-P A300 NCF

NC Joining System NCF


User/Control

PLC
K1 Presse 2.4 Linie 2/541r Sys: OK

100 kN5 4

P0 3
Example programs for
2
Status S7 and Allen-Bradley
1 available
SA Control
25 00 mm Profibus
Tab Curs Serv Zur Sollw Kalib Doku

Parallel interface

SSI-Signal
(Absolute encoder)

Status
Control

Quick stop
or Limit+

Force Signal
Programming

Feedback

Motor

Description of device interfaces see:


Operating instruction DMF-P A300 NCF Type 4734A...
DMF-P A310 Universal Type 4740A... No. 002-518 Part 2
Interface and Documentation Bosch Rexroth IndraDrive

Page 12 002-518-3e-01.14
System Description

2.1.4 Front View and Description of Position DMF-P A300 NCF Type 4734A…

1 2

C1 Press 2.4 Line 2/541r Sys: OK

5 4 3
F „mm“ 3
4
2
1 5
SA

25.00 mm
Tab Curs Serv Servo Setpt Calib Docu 6

8 9

1 LC-screen with measuring curve and additional information


2 Signal indicator
3 Yellow signal indicator Operating Measurement active
4 Green signal indicator OK Measurement (joining) in tolerance range
5 Red signal indicator NOK Measurement (joining) not ok
6 Yellow signal indicator System OK Device ready for operation
ENTER, Accept value, reset of piezo force sen-
7 ENTER key, confirmation
sors (Menu Service)
8 Description of the function keys e.g. key F1  table
9 Function keys F1 to F7 menu-dependent functions

002-518-3e-01.14 Seite 13
Contents

2.1.5 Rear View and Description of Positions DMF-P A300 NCF Type 4734A…

Basic unit, depending on Plug-in modules, depending on


configuration and options configuration and options

1 Supply (24 VDC) 10 Digital module I/O


2 LAN (Ethernet) 11 PLC

4 Serial interface (COM1) 13 Analog output (force control)


to server controller
5 Serial interface (COM2) 14 Displacement sensor module
6 Profibus 15 SSI
7 Parallel printer HP compatible 16 Incremental

19 Force sensor module


20 Force monitor output
21 Force input

Page 14 002-518-3e-01.14
System Description

2.2 DMF-P A310 Universal Type 4740A…

2.2.1 General Function


The force/displacement measuring system DMF-P A310
Universal is used for monitoring of joining and press-fitting
operations in conjunction with NC joining modules and the
associated IndraDrive servo-controller and can be operated
with electromechanical joining modules of the NCFH,
NCFN, NCFT, NCFS, and NCFB type. The measuring sys-
tem also has a fieldbus master that, together with the se-
quence controller, drives the servo-controller and thus the
NC joining module.

 Integrated sequence controller with jog, step, and au-


tomatic operating modes
 Additional fieldbus interfaces for the analogue PLC (op-
tional)
 Forward/reverse measurement
 Tension/compression applications
 4-quadrant measurement option
 32 programs with up to 8 evaluation functions (toler-
ance window)
 Additional window types: bend point, gradient, speed,
mechanical operation, or point-by-point teach-in pro-
cess
 Online and offline evaluation
 Statistics with protocolling functions
 Protocolling of measurements (I-P.M., Q-DAS, csv, ...)
 100 curve memory, 1 000 measurement memory
 Self-monitoring and diagnosis
 Webserver for visualization, modification, and archiving
as well as remote controller through a PC via Ethernet
 Master measurement

002-518-3e-01.14 Seite 15
Contents

2.3 Schematic Diagram using IndraDrive and DMF-P A310 Universal

NCF (H) (N) (S) (B) (T)-System


User/Control

PLC
K1 Presse 2.4 Linie 2/541r Sys: OK

100 kN5 4

P0 3

Status Profibus
2
1 Profinet
SA Control Devicenet
25 00 mm

Tab Curs Serv Zur Sollw Kalib Doku


Ethernet/IP
CANOpen
16 DI / DO

Optional external
displacement sensor
can be connected

Displacement
actual value

Force Signal
EtherNet/IP
Control, Status, Parameters,
Actual Values

Actual Force
Value

Feedback

Motor

For the connection diagram of individual devices, refer to:


Operating Manual 002-518 Part 2 Interface and Docu-
mentation Bosch Rexroth IndraDrive.

Page 16 002-518-3e-01.14
System Description

2.3.1 Front View an Description of Positions DMF-P A310 Universal

1 2

C1 Presse 2.4 Linie 2/541r Sys: OK

100KN 5 4 3
0V 3
4
2
5
1
SA

25.00 mm
Tab Curs Serv Anst Sollw Kalib Doku 6

8 9

1 LC-screen with measuring curve and additional information


2 Signal indicator
3 Yellow signal indicator Operating Measurement active
4 Green signal indicator OK Measurement (joining) in tolerance range
5 Red signal indicator NOK Measurement (joining) not ok
6 Yellow signal indicator System OK Device ready for operation
ENTER, Accept value, reset of piezo force sen-
7 ENTER key, confirmation
sors
8 Description of the function keys e.g. key F1  table
9 Function keys F1 to F7 menu-dependent functions

002-518-3e-01.14 Seite 17
Contents

2.3.2 Rear View and Description of Positions DMF-P A310 Universal

9 12 15
7
8a 8b 16
13

6 10
17
14
4 5

11

1
2

Basic unit, depending on configuration and Plug-in modules, depending on configuration


options and options

10 BMS 16 inputs and 16 outputs


1 Supply (24 VDC)
11 Analog output
2 LAN (Ethernet)
12 Displacement sensor module (optional for
external displacement sensor)
4 Serial interface (COM1)
13 SSI
5 Serial interface (COM2)
14 Incremental
6 Profibus (option)
15 Force sensor module
7 Parallel printer HP compatible
16 Force monitor output
8a EtherNet/IP-Master for control, data
17 Force input
transmission and path detection from
NC joining module
9 … 17 View of plug-in units 9, 12 and 15 are
8b Fieldbus slave for PLC connection,
dependent on the configuration, further options
e.g. Profinet, EtherNet/IP, etc. (op-
are possible.
tional)
9 Digital module I/O (optional)

Page 18 002-518-3e-01.14
Joining/Measurement

3. Joining/Measurement

3.1 DMF-P A300 NCF Type 4734A…


The NC joining operation must be defined from the user
(Positions, speed of movement…). The NC joining opera-
tion is controlled by the plc of the user.

The position sets (Positions, speed of movement…) are


programmed and stored at the monitoring system DMF-P
A300 NCF Type 4734A... and transferred to the servo con-
troller. The PLC selects and starts the required position set.
The positioning of the spindle is now performed by the
servo-controller, which displays a signal message as soon
as the target position is reached. Then the PLC can select a
new position set and move to the next process position.
This allows breakpoints, manual interventions by the oper-
ator, parts exchange, etc.
In case of position sets with automatic set point record
stepping – i.e. servo controller controlled automatic step-
ping from one position set to the next – only the first set
has to be started. The ready signal comes on after the last
position has been approached.

Transmission of position sets from the monitoring system


DMF-P to the servo controller is performed automatically
or manually according to the system settings. For further
information about the activation, please refer to the in-
struction manual of the servo controller.
Each position set in the servo controller can be called up
individually by the PLC. No activation by the DMF-P A300
NCF Type 4734A... takes place.

Starting the joining operation although the measurement


will be started.

During the measurement X- and Y-signals are acquired


synchronous and recorded (trace of measurement). The
measurement is activated by an external signal. The begin-
ning of the trace recording can although be effected by a
programmed trigger level. By user defined tolerance win-
dows the evaluation of the measured trace will be done
and a definite detection of OK and NOK is performed

002-518-3e-01.14 Seite 19
Contents

3.1.1 Standard Joining Operation (Press Parameter Menu: Short)

Position set 1 Position set 2 Position set 0

Home position
Pos. 0

Start joining
Pos. 1

Pos. 2
End of joining

Home position Idle stroke Joining Back stroke


(fast forward) (fast backward)
until work piece to home position

In this programming mode the functions of the individual


position sets are determined by the DMF-P A300 NCF Typ
4734A….

Menu designation Position set Set point record stepping Function


Home position 0 No Approach home position, then stop
Idle stroke end 1 Yes Positioning until work piece
Joining end 2 No Joining, then stop

The PLC only starts position set 1. The required speed re-
duction at the end of the blank stroke is performed by the
servo controller without standstill and without additional
control by the PLC. The following record 2 – joining – is
started. Only when its target position is reached the servo
controller signals the reaching of target position and stops
the drive.

Now the PLC starts position set 0 for home position run.
The PLC alone determines the moment. Like that, e.g. in
case of faulty components a confirmation by the operator
can be awaited.

Page 20 002-518-3e-01.14
Joining/Measurement

Home position
Pos. set 2
PLC Start Pos. set 1 Stop
Idle stroke
v [mm/s]

Joining

Measurement

Pos. set 0 Back stroke PLC Start

002-518-3e-01.14 Seite 21
Contents

3.1.2 Extended Joining Operation (Press Parameter Menu: Long)


For more complex press operations or if breakpoints for the
supply of material or tools are required, an extended press
parameter menu with up to 16 position sets per program is
available. Here, one of the possibilities is the free assign-
ment of record stepping modes to create operational pro-
files also with breakpoint and inversion of the direction of
travel.

Position set 1 Position set 2 Position set 3 Position set 4 Position set 0

Home position Idle stroke 1 Joining 1 Idle stroke 2 Joining 2 Back stroke
(fast forward) (fast backward)
until work piece to home position

The PLC only starts position set 1. The required speed re-
duction at the end of the respective target positions is per-
formed by the servo controller without standstill and with-
out additional activation by the PLC. The following records
2 to 4 are started. Only when the target position of posi-
tion set 4 is reached the servo controller will signal the
reaching of the target position and stop the drive.
Then the PLC starts position set 0 for home position run.
The PLC will again determine the moment.

Page 22 002-518-3e-01.14
Joining/Measurement

Home position
Pos. set 4
PLC Start
Stop
Idle stroke 1
V [mm/s]
Idle stroke 2

Joining 1
Joining 2
Measurement

Pos. set 1 Pos. set 2 Pos. set 3

Pos. set 0 Back stroke PLC Start

002-518-3e-01.14 Seite 23
Contents

3.2 DMF-P A310 Universal Type 4740A…


The joining process shall be determined by the user (posi-
tions, traversing speeds….).
With the sequencing controller that is part of the monitor-
ing and evaluation system DMF-P A310 Universal Type
4740A... , the joining sequence is controlled in dependence
of machine and equipment PLC.
The position sets (positions, traversing speeds...) and join-
ing sequences are parameterised in the monitoring and
evaluation system DMF-P A310 Universal Type 4740A...
The field bus master directly initiates communication with
the servo controller.
For NC joining system operation, three operating modes
are available: Jog mode, move and automatic mode.
The PLC selects the desired program, operating mode and
– if reqired – the position set and starts the movement /
sequence through adequate control signals. Positioning of
the NC joining module is performed by the servo control-
ler. Upon reaching the desired position, a feedback mes-
sage is issued. Depending on the kind of operating mode,
the PLC then triggers new positions by means of new posi-
tion sets or – in the automatic mode – activates the back
stroke.
This enables flexible adjustment to the task at hand. Inter-
mediate stops, manual interference through the operator,
parts exchange etc. are possible.
Each individual position set can be called up by the PLC
via DMF-P A310 Universal Type 4740A... .
In positioning sets with automated record switching – au-
tomated switching triggered by the servo controller, auto-
mated switching from one position set to the next record –
only the first record has to be started. The completion mes-
sage is issued upon reaching the last position.

Control signals and impulse diagrams regarding indi-


vidual operating modes are described in detail in the
Communications Operating Manual (BA Nr. 002-518d,
part 4) single-channel force-displacement measuring
device DMF-P A300 NCF Type 4734A... and DMF-P
A310 Universal for NC joining systems. The required
GSD files (device master files) are contained on the
documentation CD.

 Data contained on documentation CD \DE\SPS\


GSD_Profibus\A300_A310\GSD_V454\A400_454.gsd
 IndraDrive Firmware 7 index: \DE\SPS\GSD_Profi-
bus\IndraDrive

Page 24 002-518-3e-01.14
Joining/Measurement

The measuring process starts when the joining sequence


begins.
During the measuring process, X and Y signals are meas-
ured and recorded (measuring curve). The start of measur-
ing can be triggered by means of an external signal or in-
ternal condition (X value, waypoint or Y value, force). Us-
ing an assessment window previously defined by the user,
the measuring curve is evaluated and a unique GOOD (IO)
or REJECT (NIO) detection is run.

3.2.1 Standard Joining Sequence (Press parameter menu: Short)

Position set 1 Position set 2 Position set 0

Home position
Pos. 0

Start of Joining
Pos. 1

Pos. 2
End of Joining

Home position Idle stroke Joining Back stroke


(fast forward stroke) (fast return stroke)
to the workpiece back to the home position

In this type of parameter, the functions of the individual


positioning records are determined by the DMF-P A310
Universal Type 4740A….

Setpoint record step-


Menu designation Position set Function
ping
Home position 0 no Approach home position, then stop
Idle stroke end 1 yes Positioning until workpiece
Joining end 2 no Joining, then stop

002-518-3e-01.14 Seite 25
Contents

The PLC either starts position set 1 directly from operating


mode Move or triggers the whole cycle via Start from the
Automatic operating mode. The required speed reduction
at the end of the idle stroke is set by the servo controller
without stops or another triggering event via the PLC. The
sequential record 2 – Joining – is executed. Only when its
target position is reached or if a trigger is initiated , the
servo controller stops the advance and is reported by the
device. Now the PLC can start the back stroke. This is ei-
ther effected by the command to traverse back or by selec-
tion of position set 0 in the Move operating mode to Home
position traverse. The right time is exclusively determined
by the PLC. Therefore, it might be necessary to wait for the
user's confirmation in case parts are defect.

Home position
Pos. set 2
PLC Start Pos. set 1 Stop
Idle stroke
v [mm/s]

Joining

Measurement

Pos. set 0 Back stroke PLC Start

Page 26 002-518-3e-01.14
Joining/Measurement

3.2.2 Extended Joining Sequence (Press Parameter Menu: Long)

For complex joining processes or if intermediate stops are


required for material or tool feed an extended press pa-
rameter menu is available with up to 16 position sets per
program. Amongst others, this provides for the free alloca-
tion of record switching modes to create stroke profiles al-
so including intermediate stops and stroke reversal.

Example
Pos. set 1 Pos. set 2 Pos. set 3 Pos. set 4 Pos. set 0

Home position Idle stroke 1 Joining 1 Idle stroke 2 Joining 2 Back stroke
(fast forward stroke) (Fast return stroke)
to workpiece to home positi

The PLC just triggers position set 1. The required speed ad-
justments at the end of the respective target positons are
initiated by the servo controller without stops and further
control by means of the PLC.
The sequential sets 2 to 4 are executed. Only when the
target positon is reached with position set 4, a signal is is-
sued by the device after stopping the drive.
Now, the PLC can start the back stroke. This is either ef-
fected by the command to traverse back or by selection of
position set 0 in the operating mode Move to Home posi-
tion traverse. Again, the right time for this is exclusively de-
termined by the PLC.

002-518-3e-01.14 Seite 27
Contents

Home position
Pos. set 4
PLC Start
Stop
Idle stroke 1
V [mm/s]
Idle stroke 2

Joining 1
Joining 2
Measurement

Pos. set 1 Pos. set 2 Pos. set 3

Pos. set 0 Back stroke PLC Start

Page 28 002-518-3e-01.14
Joining/Measurement

3.3 Measurement of Force (y) via Displacement (x) y = f(x)


19B

The joining of a shank into a boring with joining into block


can be taken as a typical example.

of force to block power


Reaching of the block
position with increase
Start position with
without force

Joining operation
with force from
force increase
Idle stroke

sliding friction
Force (Y)

related force value

Displacement (X)

single displacement value

In this joining process, a stroke is effected in one direction


and only compressive forces occur. For each displacement
value the maximally occurring force (compressive force) is
recorded, displayed and used for the evaluation.

For this type of measurement forward is selected as meas-


uring direction and compression as force direction in the
parameter menu of the respective set point record.

002-518-3e-01.14 Seite 29
Contents

3.4 Measurement During Forward and Backward Movement


20B

Here in this example, the recording and evaluation is per-


formed for both directions of movement (e.g. testing of
disc spring packets or dampers).
Force (y)

related force value


forward

related force value


backward

Displacement (x)

single displacement value

Here the pairs of values x/y are recorded independently in


both directions of movement.
In this example only compressive forces are measured,
therefore the maximal force is measured and evaluated for
each waypoint.

In the parameter menu of the respective set point record


forward & backward is selected as measuring direction for
this type of measurement, and compression as direction of
force. The sensitivity of the reverse identification can be set
in the menu reverse identification. It can be defined for the
evaluation windows in which direction of movement the
evaluation should be carried out.

The measuring results are displayed in two separate tables


for forward and backward.

Page 30 002-518-3e-01.14
Joining/Measurement

3.5 Measurement with Compressive and Traction Forces


21B

The measurement and recording of compressive- and trac-


tion forces is performed either in two or four quadrants,
depending if the displacement (x) can only accept positive
or positive and negative values. Both measurements are
possible. In the following example a four-quadrant meas-
urement is shown. A joint or damper analysis can be taken
as an example for that.

Force (y)
related force value
forward

single displacement value

Displacement (x)

related force value


backward

For both directions of movement the pairs of value x/y are


recorded independently. In the forward movement com-
pressive forces occur and in the backward movement trac-
tion forces occur.

When compressive and traction forces are recorded simul-


taneously, both the maximum force value (max. value) and
the minimum force value (min. value) are saved at the re-
spective waypoint.

For this type of measurement forward & backward is se-


lected as measuring direction in the parameter menu of the
respective set point record and compression & traction is
selected as force direction. The sensitivity of the reverse
identification can be set in the menu reverse identification.
It can be defined for the evaluation windows for which di-
rection of movement the evaluation should be performed.

The measuring results are displayed in two separate tables


for forward and backward .

002-518-3e-01.14 Seite 31
Contents

3.6 Measurement of Force (y) Over a Range of Time (t) y = f(t)


2B

If no reference to a displacement (x) is required or if oper-


ated with constant advance speed, instead of a measure-
ment y=f(x), the force(y) can be measured as function over
a range of time.
A displacement sensor is like that not necessary. In addi-
tion, this type of measurement can be used to record other
time-dependent curves.
Force (y)

related force value

Time (t)

single displacement value

For the measurement over time the sensor type time is se-
lected in the menu calibration of x-axis (see chapter 7.3.1
and following).

Page 32 002-518-3e-01.14
Control and Signals

4. Control and Signals

4.1 DMF-P A300 NCF Type 4734A…

4.1.1 Standard Measurement Process


Measurement process without servo controller signals (See
also operating instructions 002-518 Part 1, Electromagnetic
NC joining system)
Measuring cycle is ended by 20 % displacement reverse.

Measuring cycle
(DMFP intern)
Reverse 20 %
of meas. way
Displ. sensor
*
1. step Setp. rec. 20 to 1
setp. rec 2 4 valid
0
(5 outputs PLC)
>100ms

***
2. step Ready for meas. 1 Protocal output
(Output DMFP)
0

Meas._Start 1
(Output PLC)
0 ****
read OK or NOK

Sequence_end 1
(output DMFP)
0
**
OK (IO) 1
(output DMFP)
0

NOK (NIO) 1
(output DMFP)
0

System OK 1
(output DMFP)
0

* Start of the force-fitting only when “Sequence_End” is in logic state 0 (low) !


** “Measurement_Start“ can only be cut off if “Sequence_End” is in logic state 0 (low) !
*** 100 ms before "Measurement_Start” is activated, the PLC must set the outputs “Setp.rec0” to
“Setp.rec24” for the required measuring program!
**** “Measurement_Start” is only accepted, if the output "Ready" is in logic state 1 (high).

002-518-3e-01.14 Seite 33
Contents

Caution: To end a started measuring cycle when a se-


quence is stopped (e.g. by emergency stop) apply
“Measurement_Stop” , until “Sequence_End” changes
to logic state 1 (high) (e.g. run to basic position or when
switching to manual operation).

Page 34 002-518-3e-01.14
Control and Signals

4.1.2 Test Sequence (Self Test)

To ensure measurement reliability, a unit self-test can be


run in accordance with the following impulse diagram.

System test-cycle 1 approx. 0,5 sec.


approx. 0.1 sec.
0

Test 1
(output PLC) 0
read System OK

End of cycle 1
(output DMFP) 0

1
OK (IO)
(output DMFP) 0

1
NOK (NIO)
(output DMFP) 0

1 *
System OK
(output DMFP) 0

The self test can be proceeded before every measurement,


although testing ready state. In case of faulty menu select
(e.g. set point input) SystemOK will be deactivated.

The self test clears all set digital outputs (OK, NOK, YTE,
etc.) and all depending control LEDs

* After the test cycle the output "SystemOK" switches to


Low, if an error occurred.
If there is no error, SystemOK" remains on High.

For safety parts the test sequence should be performed be-


fore and after each part.
The test sequence should be integrated in the control cycle
so that no cycle time is lost (e.g. during parts supply).

002-518-3e-01.14 Seite 35
Contents

4.2 DMF-P A310 Universal Type 4740A…

4.2.1 Standard impulse diagram, joining process


The procedure is described in detail in the Communications
Operating Manual (BA Nr. 002-518d, part 4) single-
channel force-displacement measuring device DMF-P A300
NCF Type 4734A... and DMF-P A310 Universal Type
4740A… for NC joining systems.

4.2.2 System Test Impulse Diagram


To ensure measurement reliability, a unit self-test can be
run in accordance with the following impulse diagram.

TA

AE

300 ms

SystemOK

The unit self-test can be performed prior to each meas-


urement and also to test if the device is ready to measure.
If the wrong menu is selected (e.g. setpoint value entry),
the message SystemOK is deleted.

The self-test deletes all digital outputs, which were previ-


ously set (OK, NOK, YTE etc) along with the corresponding
control messages.

Page 36 002-518-3e-01.14
Operation

5. Operation

5.1 Status Line/Input/Soft Key-Functions


25B

5.1.1 Status Line


39B

The so-called status line is displayed on top, which gives a


reference to the respective display.

1 2 3 4
Status line

1 Channel number
2 Channel name
3 Unit name
4 System status

5.1.2 Soft Key – Function (Function Keys F1 … F7)


40B

Control and input can either be performed with the keys


on the front plate or with a commercial PC-keyboard with
PS2 connection (position of the connecting socket see 3.4).
On this extern keyboard the assignment of the function
keys F1-F7 is equal to the one on the device.

Values are always accepted with the ENTER key

At the lower edge of the screen, the menu-dependent


functions of the control keys are shown, as well as the op-
tions of function selections.

002-518-3e-01.14 Seite 37
Contents

Here for example the screen Measured values: Table

Key Abbreviation Menu function

Measuring data presented as charac-


Diagr.
teristic
Serv. Service and diagnosis

Servo Servo controller

Setp. Input of set points

Calib. Calibration and system settings

Docu Documentation and protocol

Example: The Measurement Values screen: Table


for DMF-P A310 Universal Type 4740A…

Page 38 002-518-3e-01.14
Operation

Button Abbreviation Menu function

Measurement data displayed


Diagr.
as characteristic curve
Serv. Service and diagnosis

Ctrl. Control

SetP. Set point entry


Calibration and system set-
Calib.
tings
Docu Documentation and logging

002-518-3e-01.14 Seite 39
Contents

5.1.3 Input of Values

Use the Cursor keys to select the column, which has to be


changed. It will be shown with the respective inversion.

Select the processing mode.

5.1.3.1 Numeric Values


With the Cursor keys the position, which has to be
changed, can be selected. It will be displayed inversed and
blinking.

Incrementing the Decrementing the


selected position selected position

Accept the entry

When negative values are entered, first change the num-


ber and then the sign with

5.1.3.2 Alphanumeric Value


The position, which has to be changed, can be selected
with the Cursor keys. It will be displayed inversed and
blinking.

Selected position Selected position


Select the forward Select the backward
symbol symbol

Accept the entry

You can switch between capital and small


letters with F5.

Page 40 002-518-3e-01.14
Operation

5.1.3.3 Input with an External Keyboard


With an extern keyboard it is also possible to navigate be-
tween the input fields with the arrow keys. The input of
numeric values can be performed directly with the number
keys. The input must always start left aligned. The comma
positions, which are set in the respective calibration menu,
cannot be changed here. In the alphanumeric fields the fol-
lowing symbols are available:

AÄBCDEFGHIJKLMNOÖPQRSTUÜVWXYZ0123456789.:+-/\
aäbcdefghijklmnoöpqrstuüvwxyz0123456789.:+-/\

5.1.4 Special Inputs


42B

ends the measurement manually.

002-518-3e-01.14 Seite 41
Contents

5.2 Menu Structure DMF-P A300 NCF Type 4734A…


26B

Page 42 002-518-3e-01.14
Operation

5.3 Menu Structure DMF-P A310 Universal Type 4740A…


26B

002-518-3e-01.14 Seite 43
Contents

5.4 Difference between DMF-P A300 NCF Type 4734A…/DMF-P A310


Universal Type 4740A…

In contrast to the device DMF-P A300 NCF Type 4734A…,


the device DMF-P A310 Universal Type 4740A…also con-
tains a function for manual joining module control by
means of an integrated field bus master which allows direct
communication with the servo controller. For this purpose,
three operating modes are available:

 Service (jog mode)


 Move (stepping mode)
 Automatic (automatic mode)

For details, see chapter: Manual control with DMF-P A310


Universal Type 4740A… .

Page 44 002-518-3e-01.14
Evaluation of the Measured Values

6. Evaluation of the Measured Values

6.1 Evaluation Methods


28B

For evaluation different tolerance windows are available.


The position referring of the windows can be absolute or
"dynamic". For dynamic windows the displacement coor-
dinates (Smin and Smax ) of the force-displacement windows
are set from the actual reached displacement end-point af-
ter the measurement .
The relative displacement coordinates are programmed
with negative signs (example below: Wn2 and Wn2‘) for
these dynamic windows. In addition the setting dynamic
forward-backward must be made (see Setpoint input chap-
ter 7.1.1). If the displacement coordinates are programmed
with positive sign and the setting absolute is selected, a
"fixed" window will result like in the evaluation method 1
(example below: Fe1 or FeX).

Evaluation Absolute Evaluation Absolute/Dynamic


Example: Smin = 8 mm, Smax = 10 mm Example: Absolute Wn 1: Smin = 2 mm, Smax = 4 mm
Dynamic Wn 2: Smin = –4 mm, Smax = –2 mm

F „kN“ F „kN“

Wn1
WnX Wn2 Wn2‘

Send Send Send‘


S „mm“ S „mm“
Smin Smin Smax Smax

Smax Smax Smin Smin

Dynamic windows are mainly used where there are work


pieces or work piece carriers with tolerances. The use of a
dynamic tolerance window with live-function at the same
time is not possible.

In 4-quadrant measurements the end point on the left-


hand side can also be used as reference. Here the relative
coordinates must be entered positively. The adjustment
for the dynamic must be set backward-forward.

002-518-3e-01.14 Seite 45
Contents

6.2 Tolerance Windows


29B

6.2.1 Overview Table


43B

Comparison
Type DMF-P A300 Designation OK NOK
NCF V3

Displacement
0 window
(on the right)

Force
0 window
(maximum)

Joining
1
window

Limitation
window
2
(bottom -
right)

Start position
window,
3 Limitation
window (at
the top left)

Snap
window,
4
Peak window
(at the top)

Rising
5
window

Page 46 002-518-3e-01.14
Evaluation of the Measured Values

Comparison
Designation OK NOK
DMF-P A300
NCF V3

Average
6 value
window

Limitation
7
- window
(at the top
right)

8
- End window
at the top

9
- Start window
at the top

Snap
window,
10
- Peak window
(at the
bottom)

End window
11
- at the
bottom

Start window
12
- at the
bottom

002-518-3e-01.14 Seite 47
Contents

Comparison Designation OK NOK

DMF-P A300
NCF V3

Reverse
13
- window
on the right

Reverse
14
- window
on the left

Limitation
15
- window
(at the
bottom left)

Displacement
16
- window
(left)

Force
17
- window
(minimum)

Combined
18 Start-End
window

vmax vmax Speed


20 vmin vmin Vmin ≤ V ≤ Vmax V < Vmin oder V > Vmax
window

Gradient
gradmax
window gradmin grad < gradmin
23
gradmin
- (Online YTE,
no OK/NOK
≤ grad ≤
gradmax
oder
grad > gradmax
evaluation)

Page 48 002-518-3e-01.14
Evaluation of the Measured Values

Comparison
Designation OK NOK
DMF-P A300
NCF V3
Δgradmax

24
Δgradmin
- Breakpoint
window

Localized
27
- displacement
monitoring

Localized
28
- force
monitoring

29
- Restricted
area

MinPosition
30
window

MaxPosition
31
window

Wmax Wmax Energy win-


32 Wmin Wmin Wmin ≤ Wist ≤ Wmax Wist < Vmin oder Wist > Vmax
dow

The windows are displayed with a dashed line in the dia-


gram where the measurement curve should enter or exit
the border. Force-displacement rectangular windows are
specified by 4 values, and trapezoidal windows by 6 values.
start point of the curve
end point of the curve

For further information please refer to the detailed de-


scription of the windows.

002-518-3e-01.14 Seite 49
Contents

6.2.2 Window Type 0; Displacement Window Right


4B

For the evaluation of a maximally achieved travel path, in-


dependent of the joining force which has occurred during
the process. The maximum displacement Xmax traveled (the
displacement end) is saved and evaluated according to Smin
and Smax. . The position of the window can be defined by
absolute values of Smin and Smax or using teach-in. Details
for set point input refer to chapter 7.1.1., submenu win-
dow definition.

Smin and Smax absolute input

Only forward measurement Forward-backward measurement

1 1
Y Y

Smin Xmax Smax X Smin Xmax Smax X

Measured values: table


Pr. Actual values Set points
0 min max min max Forw.
1 Xmax Smin Smax mm

OK
The measuring curve can either end in the displacement
window or exit on the Smin - side.

Xmin ≤ Xmax ≤ Xmax

Page 50 002-518-3e-01.14
Evaluation of the Measured Values

NOK
The joining operation is evaluated NOK if:
the curve ends or returns before it has reached Smin

Xmax < Smin

or
the curve exceeds Smax.

Smax < Xmax

Smin and Smax using teach-in

Selection Mastercheck will fit window… must be


activated. At submenu window definition the input of Smin
and Smax will be done as input of absolute values. The dis-
tance between Smin and Smax defines the size of the window.
Starting measurement using input master control teach-in
function will be activated and the window will be placed at
the end of displacement.

Before measurement mastercheck After measurement mastercheck

Y Y
= =

Smin Smax X Smin Xmax Smax X

After measurement Mastercheck the window is placed at


the maximal reached displacement Xmax symmetrical.
Using normal measuring, the window Type 0 acts like hav-
ing absolute values for borders of window.

Applications using master sample function and its check


starting measuring by input master control, the window
must be placed absolute. It is recommended to generate
a own program for this function with a window having
absolute borders.

002-518-3e-01.14 Seite 51
Contents

6.2.3 Window Type 0; Force Window Maximum


45B

For the evaluation of a maximally achieved joining force


Ymax, independent of the displacement traveled. The maxi-
mum of the complete curve is saved and evaluated accord-
ing to Fmin and Fmax. The placement of the window can be
defined by absolute values of Fmin and Fmax or using teach-
in. Details for set point input refer to chapter 7.1.1., sub-
menu window definition.

Fmin and Fmax absolute input

Measurement ends Measurement continues

Y
Fmax Fmax

Ymax Ymax
Fmin Fmin

X X

Measured values: table


Pr. Actual values Set points
0 min max min max Forw.
1 Ymax Fmin Fmax kN

OK
The measuring curve may either end in the force window
or exit the window on the Fmin - side.

Fmin ≤ Ymax ≤ Fmax

Page 52 002-518-3e-01.14
Evaluation of the Measured Values

NOK
The joining operation is evaluated NOK if:

the curve ends or has its maximum vertex before Fmin is


reached

Ymax < Fmin

or
the curve exceeds Fmax.

Fmax < Ymax

Fmin and Fmax using Teach-In


Selection Mastercheck will fit window… must be
activated. At submenu window definition the input of Fmin
and Fmax will be done as input of absolute values. The dif-
ference between Fmin and Fmax defines the size of the win-
dow. Starting measurement using input master control
teach-in function will be activated and the window will be
placed at the maximum of force.

Before measurement After measurement


mastercheck mastercheck

Y Y
Fmax

Ymax
=
Fmax Fmin
=

Fmin

X X

After measurement Mastercheck the window is placed at


the maximal reached force Fmax symmetrical.

Using normal measuring, the window Type 0 acts like hav-


ing absolute values for borders of window.

002-518-3e-01.14 Seite 53
Contents

6.2.4 Window Type 1; Joining Window (Live Function)


46B

With the joining window the joining force can be moni-


tored alongside an element of length.
The window can be activated for a certain direction of
movement, e.g. only forward or only backward, and for
both directions at the same time (forward & backward). It
is also possible to parameterise the window trapezoid-
shaped. When it is used as one of the first 4 windows in
the measuring program an additional Live-function, i.e.
evaluation during the measurement already, is available
(see also chapter 7.1.1).

OK-measurement with
Y rectangular window

Fmax
Ymax
Measured values: table
Ymin Pr. Actual values Set points
1 0 min max min max Forw.
Fmin
1 Ymin Ymax Fmin Fmax kN

Smin Smax X

OK-measurement with
Y rectangular window

Fmax
Ymax Measured values: table
Pr. Actual values Set points
Ymin 1 0 min max min max Forw.
Fmin 1 Ymin Ymax Fmin Fmax kN

Smin Smax X

Page 54 002-518-3e-01.14
Evaluation of the Measured Values

OK-measurement with
Y trapezoidal window
Fmax (Smax)
Frelmax
Ymax
Fmax (Smin) Measured values: table
1 Pr. Actual values Set points
0 min max min max Forw.
Fmin(Smax) 1 Ymin Ymax Frelmin Frelmax kN
Ymin
Frelmin
Fmin (Smin)

Smin Smax X

For trapezoidal windows always the minimum space from


the curve to the adjoining
upper and lower edges of the window is defined as actual
value. As set point the maximum or minimum value of
the border at the respective waypoint is displayed.

OK-measurement for forward-


Y & backward movement
Measured values: table
Pr. Actual values Set points
Fmax 0 min max min max Forw.
Ymax
1 Ymin Ymax Fmin Fmax kN
Ymin
Ymax
Ymin
Fmin
Measured values: table
Pr. Actual values Set points
0 min max min max Backw.
1 Ymin Ymax Fmin Fmax kN
Smin Smax X

With the ENTER key you can switch between


the display forward- and backward.

002-518-3e-01.14 Seite 55
Contents

OK
The measuring curve must completely pass through the
force window. The upper and lower edge of the window
must not be violated.

Fmin ≤ Y ≤ Fmax for rectangular


windows
Frelmin ≤ Y ≤ Frelmax for trapezoidal
windows

NOK
The joining operation is evaluated NOK if:

the curve ends before it has reached Smin or if the window


is not completely passed through

SEnde < Smax

or
the curve starts after Smin

Smin < SStart

or
the curve exceeds Fmax (Frelmax )

Fmax < Y for rectang. windows

Frelmax < Y for trapez. windows

or
the curve remains below Fmin (Frelmin )

Y < Fmin for rectang. windows

Y < Frelmin for trapez. windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

Page 56 002-518-3e-01.14
Evaluation of the Measured Values

Live-Function

NOK-measurement with
Y rectangular window

Fmax

Fmin

Smin Smax X

WXmi
Output for window WX
(X = window number)
WXmax

Window type 1 enables reaction of exceeding or fall short


of window set value during measuring in the range of win-
dow displacement. The depending outputs are latched for
further evaluation. The violation of the window limits are
used for NOK evaluation of the measurement at cycle end.

Dynamic tolerance windows cannot be used for Live-


function detection. Dynamic tolerance windows position-
ing is done at the end of the measurement. Windows
using Live-function must be configured absolute.

002-518-3e-01.14 Seite 57
Contents

6.2.5 Window Type 2; Limitation Window at the Bottom Right


47B

The limitation window at the bottom right can be activated


for a certain direction of movement, e.g. only forward or
only backward. It can also be activated for both directions
at the same time (forward & backward). It is also possible
to parameterise the window in trapezoidal shape.

OK-measurement with
Y rectangular windows
Measured values: table
Fmax Pr. Actual values Set points
1 0 min max min max Forw.
1 Ymin Fmin kN
Ymin
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window Measured values: table
Fmax (Smax) Pr. Actual values Set points
0 min max min max Forw.
1 Ymin Frelmin kN
Fmax (Smin)
1
Fmin(Smax)
Ymin
Frelmin
Fmin (Smin)

Smin Smax X

For trapezoidal windows always the minimum space from


the measuring curve to the adjoining lower edge of the
window is defined as Actual value. The minimum value
of the border at the corresponding waypoint is displayed
as set point.

Page 58 002-518-3e-01.14
Evaluation of the Measured Values

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Measured values: table
Pr. Actual values Set points
Fmax (Smin) 0 min max min max Forw.
1 Ymin Frelmin kN
1
Fmin(Smax)
Frelmin
Fmin (Smin) The entry with the violation is high-
Ymin lighted black in the table.
Smin Smax X

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Ymax Measured values: table
Pr. Actual values Set points
Fmax (Smin) 0 min max min max Forw.
1 1 Ymin Ymax Frelmin Fmax * kN
Fmin(Smax)
Ymin
Frelmin
Fmin (Smin)
The entry with the violation is high-
Smin Smax X lighted black in the table.

* Fmax equals here Fmax (Smax)

The same conditions apply when window type 2 is used for


backward movement (diagram, see window type 1).

002-518-3e-01.14 Seite 59
Contents

OK
The curve must pass above the lower edge of the window
and must not violate the right edge of the window. The
curve may start and/or end inside the window. At least one
measuring point must be found inside the window. The di-
rection of movement must not be violated.

forward

Fmin ≤ Y for rectangular windows


Frelmin ≤ Y for trapezoidal windows

and for Smax (if Smax is reached) must apply

backward

Fmax < Y for rectangular windows


Fmax (Smax) < Y for trapez. windows

NOK

The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y ≤ Fmin for rectangular windows

Y ≤ Frelmin for trapezoidal windows

or
the curve violates the right edge of the window at Smax

Y(Smax) ≤ Fmax for rectangular windows

Y(Smax) ≤ Fmax (Smax) for trapez. windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

Page 60 002-518-3e-01.14
Evaluation of the Measured Values

6.2.6 Window Type 3; Start Position Window, Limitation at the Top-Left


48B

The start position window, limitation window at the top -


left can be used to monitor the starting process of the parts
to be joined. The window can be activated for a certain di-
rection of movement, e.g. only forward or only backward,
and for both directions at the same time (forward & back-
ward). It is also possible to parameterise the window trape-
zoid-shaped.

OK-measurement with rec-


Y tangular window

Fmax
Ymax 1
Measured values: table
Pr. Actual values Set points
Fmin 0 min max min max Forw.
1 Ymax Fmax kN

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax)

Ymax Frelmax
Fmax (Smin)
Measured values: table
1
Fmin(Smax) Pr. Actual values Set points
0 min max min max Forw.
1 Ymax Frelmax kN
Fmin (Smin)

Smin Smax X

In trapezoidal windows always the minimum space from


the curve to the adjoining upper edge of the window is
defined as Actual value max. The maximum value of the
border at the corresponding waypoint is displayed as set
point.

002-518-3e-01.14 Seite 61
Contents

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Ymax
Measured values: table
Frelmax
Pr. Actual values Set points
Fmax (Smin) 0 min max min max Forw.
1 1 Ymax Frelmax kN
Fmin(Smax)

Fmin (Smin)
The violation is highlighted black
in the table.
Smin Smax X

NIO-Messung mit
Y Trapezfenster
Fmax (Smax)

Frelmax
Ymax
Fmax (Smin) Measured values: table
1 Pr. Actual values Set points
Fmin(Smax) 0 min max min max Forw.
Ymin 1 Ymin Ymax Fmin * Frelmax kN
Fmin (Smin)
The violation is highlighted black
Smin Smax X in the table.

* Fmin equals here Fmin (Smin)

The same applies when window type 3 is used for back-


ward movement (see window type 1).

Page 62 002-518-3e-01.14
Evaluation of the Measured Values

OK
The curve must pass below the upper edge of the window
and must not violate the left edge of the window. The
curve may start and/or end in the window. At least one
measuring point must be found inside the window. The di-
rection of movement must not be violated.

Forward

Y ≤ Fmax for rectangular windows


Y ≤ Frelmax for trapezoidal windows

and for Smin (if Smin is reached) must apply

backward

Y < Fmin for rectangular windows


Y < Fmin (Smin) for trapez. windows

NOK
The joining operation is evaluated NOK if:

the curve exceeds Fmax (Frelmax )

Fmax < Y for rectang. windows

Frelmax <Y for trapez. windows

or
if the curve violates the left edge of the window at Smin

Fmin < Y < Y(Smin) for rectangular windows

Fmin (Smin) < Y < Y(Smin) for trapezoidal windows

or

if there is no measuring point inside the window (this also


applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the X-
resolution.

002-518-3e-01.14 Seite 63
Contents

6.2.7 Window Type 4: Snap Window, Peak Window at the Top


49B

The snap window, peak window at the top can be used to


monitor the joining of lock rings or sealing rings depending
on the application. The window can be activated for a cer-
tain direction of movement, e.g. only forward or only
backward, and for both directions at the same time (for-
ward & backward). It is also possible to parameterise the
window trapezoid-shaped.
In the set value entry mask, the operating mode of the
window can be defined via the selection box (check box)
"Online Evaluation":
a) not selected: Normal Offline Evaluation of the window,
no online evaluation
b) selected: Online Evaluation, as described in the follow-
ing. The offline evaluation delivers in this case always an
OK-result, irrespective of which violation of the window
have occurred during the online evaluation.

OK-measurement with
Y rectangular window

Fmax
Ymax 1 Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fmin 1 Ymax Fmax kN

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax)
Frelmax
Ymax
Measured values: table
Fmax (Smin) Pr. Actual values Set points
1 0 Forw.
min max min max
Fmin(Smax)
1 Ymax Frelmax kN

Fmin (Smin)

Smin Smax X

For trapezoidal windows always the minimum space


between the measuring curve and the adjoining upper
edge of the window is defined as Actual value max. The
max. value of the border at the corresponding waypoint
is displayed as set point.

Page 64 002-518-3e-01.14
Evaluation of the Measured Values

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Ymax Measured values: table
Frelmax Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smin) Ymax
1 Frelmax kN
1
Fmin(Smax)

Fmin (Smin) The violation is highlighted black


in the table.
Smin Smax X

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Measured values: table
Pr. Actual values Set points
Ymax Frelmax
0 min max min max Forw.
Fmax (Smin) 1 Ymin Ymax Fmin* Frelmax kN
1
Fmin(Smax)
Ymin
Fmin (Smin) * Fmin equals here Fmin (Smin)

Smin Smax X The violation is highlighted black


in the table.

If both edges are violated the extremer


one is displayed.

When window type 4 is used for backward movement the


same conditions apply (diagram see window type 1).

002-518-3e-01.14 Seite 65
Contents

OK
The curve must pass below the upper edge of the window
and must not violate the left and right edge of the win-
dow. The curve must start and end outside the window. At
least one measuring point must be found inside the win-
dow, and the direction of movement must not be violated.

Fmin ≤ Y ≤ Fmax for rectangular windows


Frelmin ≤ Y ≤ Frelmax for trapezoidal windows

and for Smin (if Smin is reached ) must apply

Y < Fmin for rectangular windows


Y < Fmin (Smin) for trapezoidal windows

and for Smax (if Smax is reached) must apply

Y < Fmin for rectangular windows


Y < Fmin (Smax) for trapezoidal windows

NOK
The joining process is evaluated NOK if:

the curve exceeds Fmax (Frelmax )

Fmax < Y for rectang. windows

Frelmax <Y for trapez. windows


or
the curve violates the left edge of the window at Smin

Fmin < Y(Smin) for rectangular windows

Fmin (Smin) < Y(Smin) for trapez. windows


or
the curve violates the right edge of the window at Smax

Fmin < Y(Smax) for rectangular windows

Fmin (Smax) < Y(Smax) for trap. windows


or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the X-
resolution).

or
if it begins or ends inside the window.

Page 66 002-518-3e-01.14
Evaluation of the Measured Values

Online Evaluation

OK-measurement with
Y rectangular window

Fmax

Fmin

Smin Smax X

WX min

Output for window WX


(X = window number)

On reaching the force interval from Fmin to Fmax in the dis-


placement interval of the window no. X (from smin to smax)
the output is set with FX min. The output FX min stays set as
long as this is necessary, it will not be latched.
If the measurement movement changes into a direction for
which the window has not been defined, the output FX min
will be reset (deleted).

Online evaluation is only possible for the windows with


number 1 to 4.

The usage of a dynamic tolerance window together with


the online evaluation is not possible as for dynamic toler-
ance windows the position of the window is only deter-
mined after the measurement. For this reason, windows
with online evaluation have to positioned absolute.

002-518-3e-01.14 Seite 67
Contents

6.2.8 Window Type 5; Rising Window


50B

The rising window can be used to monitor an increase of


force during the joining process. The window can be acti-
vated for a certain direction of movement, e.g. only for-
ward or only backward, and for both directions at the same
time (forward & backward). It is also possible to parame-
terize the window trapezoid-shaped.

OK-measurement with rec-


Y tangular window

Measured values: table


1 Pr. Actual values Set points
0 min max min max Forw.
1 Xmin Xmax Smin Smax mm
Fmin

Smin Xmin Xmax Smax Fmax

OK-measurement with
Y trapezoidal window
Fmax (Smin)
Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smax)
1 Xmin Xmax Smin Smax mm
1
Fmin(Smin)

Fmin (Smax)

Smin Xmin Xmax Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smin)
Measured values: table
Pr. Actual values Set points
Fmax (Smax)
0 min max min max Forw.
1 Xmin Xmax Smin Smax mm
1
Fmin(Smin)

Fmin (Smax)

Smin Xmin Xmax Smax X

Page 68 002-518-3e-01.14
Evaluation of the Measured Values

NOK-measurement with
Y trapezoidal window
Fmax (Smin)
Measured values: table
Pr. Actual values Set points
Fmax (Smax)
0 min max min max Forw.
1 X.XX X.XX -.-- -.-- mm
1
Fmin(Smin)
In case of a violation all the entries in
Fmin (Smax) the table are declared invalid and high-
lighted black.
Smin Xmin Smax X

When window type 5 is used for backward movement the


same conditions apply (see diagram window type 1).

OK
The measuring curve must not violate the left and the right
edge of the window. The curve must start and end outside
of the window. At least one measuring point must be
found inside the window, and the direction of movement
must not be violated.

at Smin (if Smin is reached) the following applies

Y(Smin) < Fmin for rectangular windows

Y(Smin) < Fmin(Smin) for trapez. windows

and
for Smax (if Smax is reached) must apply

Y(Smax) > Fmax for rectangular windows

Y(Smax) > Fmax (Smax) for trapez. windows

or
for Smin (if Smin is reached) must apply

Y(Smin) > Fmax for rectangular windows

Y(Smin) > Fmax(Smin) for trapez. windows

and
for Smax (if Smax is reached) must apply

Y(Smax) < Fmin for rectangular windows

Y(Smax) < Fmin (Smax) for trapez. windows

002-518-3e-01.14 Seite 69
Contents

NOK

The joining operation is evaluated NOK if:

the measuring curve violates the left edge of the window

Fmin(Smin) ≤Y ≤ Fmax(Smin)

or
the curve violates the left edge of the window

Fmin(Smax) ≤Y ≤ Fmmax(Smax)

or
the curve violates both sides

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

or
if it starts or ends inside the window.

Page 70 002-518-3e-01.14
Evaluation of the Measured Values

6.2.9 Window Type 6; Average Value Window


51B

The average value window can be used for measurements


with broad distribution of the single measuring points, of
which the arithmetic average value has almost no fluctua-
tion. The window can be activated for a certain direction of
movement, e.g. only forward or only backward, and for
both directions at the same time (forward & backward). It
is also possible to parameterize the window trapezoid-
shaped.
OK-measurement with rec-
Y tangular window

Fmax Measured values: table


Pr. Actual values Set points
Yarmittel 0 min max min max Forw.
1 Yarmitte Yarmitte Fmin Fmax kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax)

Measured values: table


Fmax (Smin) Pr. Actual values Set points
Yarmit- 1 0 min max min max Forw.
1 Yarmitte Yarmitte Fmin Fmax kN
Fmin(Smax)
Please note that the trapezoidal win-
Fmin (Smin) dow is not practically applied, it is only
mentioned here for the sake of com-
Smin Smax X pleteness.

NOK-measurement with
Y rectangular window Measured values: table
Pr. Actual values Set points
Yarmittel 0 Forw.
min max min max
Fmax 1 Yarmitte Yarmitte Fmin * Fmax ** kN

* the higher value of Fmin(Smin) or Fmin(Smin)


Fmin ** the lower value of Fmax(Smin) or Fmax(Smin))
in trapezoidal windows

In the table the violation is highlighted


Smin Smax X black.

002-518-3e-01.14 Seite 71
Contents

OK
The arithmetic average value of the measuring curve must
not exceed the upper edge of the window and must not
remain below the lower edge of the window. The curve
must completely pass through the window.

Fmin ≤ Yarmittel ≤ Fmax

NOK
The joining is evaluated NOK if:

the measuring curve ends before it has reached Smin or it


does not completely pass through the window

SEnde < Smax

or
the curve starts after Smin

Smin < SStart

or
the arithmetic average value of the curve exceeds Fmax

Fmax < Yarmittel

or
the arithmetic average value of the curve remains below
Fmin

Yarmittel < Fmin

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

Display of actual value X.XX


or set point -.- -

Page 72 002-518-3e-01.14
Evaluation of the Measured Values

6.2.10 Window Type 7; Limitation Window Top-Right


52B

The limitation window top - right can be activated for a


certain direction of movement, e.g. only forward or only
backward, and for both directions at the same time (for-
ward & backward). It is also possible to parameterize the
window trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax Measured values: table


Ymax 1 Pr. Actual values Set points
0 min max min max Forw.
1 Ymax Frelmax kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smin)

Frelmax Measured values: table


Ymax
Pr. Actual values Set points
Fmax (Smax) 0 min max min max Forw.
1 1 Ymax Fmax kN
Fmin(Smin)

Fmin (Smax)

Smin Smax X

In trapezoidal windows always the minimum space from


the curve to the adjoining upper edges of the window is
defined as Actual value max. The max value of the
border to the corresponding waypoint is displayed as set
point.

002-518-3e-01.14 Seite 73
Contents

NOK-measurement with
Y trapezoidal window
Fmax (Smin)
Ymax
Frelmax
Measured values: table
Fmax (Smax) Pr. Actual values Set points
1 0 min max min max Forw.
Fmin(Smin)
1 Ymax Frelmax kN

Fmin (Smax)
The violation is highlighted black in the
Smin Smax X table.

NOK-measurement with
Y trapezoidal window
Fmax (Smin)
.
Frelmax
Ymax
Measured values: table
Fmax (Smax) Pr. Actual values Set points
1 0 min max min max Forw.
Fmin(Smin)
1 Ymin Ymax Fmin * Frelmax kN
Ymin
Fmin (Smax)
The violation is highlighted black in the
table .
Smin Smax X
* Fmin equals here Fmin (Smax)

The same conditions apply when window type 7 is used for


backward movement (see diagram window type 1).

Page 74 002-518-3e-01.14
Evaluation of the Measured Values

OK
The measuring curve must pass below the upper edge of
the window and must not violate the right edge of the
window. The curve may start or end inside the window. At
least one measuring point must be found inside the win-
dow. The direction of movement must not be violated.

forward

Y ≤ Fmax for rectang. windows

Y ≤ Frelmax for trapez. windows

and
for Smax (if Smax is reached) must apply

backward

Y < Fmin for rectang. Windows


Y < Fmin (Smax) for trapezoidal windows

NOK
The joining process is evaluated NOK if:

the curve exceeds Fmax (Frelmax )

Fmax < Y for rectang. windows

Frelmax <Y for trapez. windows

or
if the curve violates the right edge of the window at Smax

Fmin < Y(Smax) for rectangular windows

Fmin (Smax) < Y(Smax) for trapezoidal windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

002-518-3e-01.14 Seite 75
Contents

6.2.11 Window Type 8; End Window at the Top


53B

Depending on the application the end window can be used


to monitor the end point of the measuring curve. The win-
dow can be activated for a certain direction of movement,
e.g. only forward or only backward. It is also possible to
parameterize the window trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax Measured values: table


Ymax 1 Pr. Actual values Set points
0 min max min max Forw.
YEnde 1 YEnde Ymax Fmin Fmax kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smin)
Frelmax
Ymax Measured values: table
Pr. Actual values Set points
Fmax (Smax) 0 min max min max Forw.
YEnde 1
1 YEnde Ymax Frelmin Frelmax kN
Fmin(Smin)
Frelmin
Fmin (Smax)

Smin Smax X

In trapezoidal windows always the minimum space be-


tween the curve and the adjoining upper edges of the
window is defined as Actual value max. The max value of
the border at the corresponding waypoint is displayed as
set point. For Actual value min and set point value min an
analog display is shown with the respective min. values.

Page 76 002-518-3e-01.14
Evaluation of the Measured Values

NOK-measurement with
Y trapezoidal window
Fmax (Smin)
Ymax Measured values: table
Frelmax
Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smax)
YEnde 1 1 YEnde Ymax Frelmin Frelmax kN
Fmin(Smin)
Frelmin
Fmin (Smax)
The violation is highlighted black in the
Smin Smax X table.

NOK-measurement with
Y trapezoidal window
Fmax (Smin)
Frelmax Measured values: table
Ymax Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smax)
1 YEnde Ymax Frelmin Frelmax kN
1
Fmin(Smin)
Fmin (Smax) Frelmin
YEnde
The violation is highlighted black in the
Smin Smax X table.

When window type 8 is used for backward movement the


same conditions apply (diagram see window type 1).

OK
The curve must end in the window whereby the curve
must pass below the upper edge of the window and must
not violate the left and right edges of the window. The
curve must start outside the window, and at least one
measuring point must be found inside the window. The di-
rection of movement must not be violated.

forward
Ymax ≤ Fmax for rectangular windows
Ymax ≤ Frelmax for trapezoidal windows
Fmin ≤ YEnde for rectangular windows
Frelmin ≤ YEnde for trapezoidal windows

and for Smin (if Smin is reached) must apply

Y < Fmin for rectangular windows


Y < Fmin (Smin) for trapezoidal windows

and SEnde ≤ Smax

002-518-3e-01.14 Seite 77
Contents

backward
Ymax ≤ Fmax for rectangular windows
Ymax ≤ Frelmax for trapezoidal windows
Fmin ≤ YEnde for rectangular windows
Frelmin ≤ YEnde for trapezoidal windows

and for Smax (if Smax is reached) must apply

Y < Fmin for rectangular windows


Y < Fmin (Smax) for trapezoidal windows

and Smin ≤ SEnde

NOK
The joining process is evaluated NOK if:

the curve exceeds Fmax (Frelmax )

Fmax < Ymax for rectangular windows

Frelmax < Ymax for trapezoidal windows

or
the curve violates the left edge of the window at Smin

Fmin < Y(Smin) for rectangular windows

Fmin (Smin) < Y(Smin) for trapez. windows

In this case Actual-min and Actual-max are highlighted


black in the table.

or
the curve violates the right edge of the window at Smax

Fmin < Y(Smax) for rectangular windows

Fmin (Smax) < Y(Smax) for trap. windows

In this case Actual-min and Actual-max are highlighted


black in the table.

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

or if it starts inside the window.

Page 78 002-518-3e-01.14
Evaluation of the Measured Values

6.2.12 Window Type 9; Start Window at the Top


54B

Depending on the application the start window can be


used to monitor the start point of the curve. The window
can be activated for a certain direction of movement, e.g.
only forward or only backward. It is also possible to pa-
rameterize the window trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax Measured values: table


Ymax 1 Pr. Actual values Set points
0 min max min max Forw.
YStart
1 YStart Ymax Fmin Fmax kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax)
Measured values: table
Frelmax Pr. Actual values Set points
Ymax 0 Forw.
1 min max min max
Fmax (Smin) 1 YStart Ymax FStartmin Frelmax kN
YStart
Fmin(Smax)
FStartmin
Fmin (Smin)

Smin Smax X

In trapezoid-shaped windows the minimum space be-


tween the curve to the adjoining upper edges of the
window is defined as Actual value max. The max. value
of the border at the corresponding waypoint is displayed
as set point.

002-518-3e-01.14 Seite 79
Contents

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Ymax
Frelmax Measured values: table
1 Pr. Actual values Set points
Fmax (Smin) 0 min max min max Forw.
YStart 1 YStart Ymax Frelmin Frelmax kN
Fmin(Smax)
Freltmin
Fmin (Smin)
The violation is highlighted black in the
table.
Smin Smax X
NOK-measurement with
Y trapezoidal window
Fmax (Smax)

Frelmax
Ymax
1 Measured values: table
Fmax (Smin) Pr. Actual values Set points
0 min max min max Forw.
Fmin(Smax) 1 YEnde Ymax Frelmin Frelmax kN

Fmin (Smin) Frelmin


YStart
The violation is highlighted black in the
Smin Smax X table.

If the start point is found outside the displacement ranges


Smin - Smax ,X.XX is shown as Actual value and -.- - is shown
as set point.
When window type 9 is used for backward movement the
same conditions apply (diagram see window type 1).

OK
The curve must start inside the window, whereby the curve
must pass below the upper edge of the window and must
not violate the left and right edges of the window. The
curve must end outside the window. At least one measur-
ing point must be found inside the window, and the direc-
tion of movement must not be violated.

Forward
Ymax ≤ Fmax for rectangular windows
Ymax ≤ Frelmax for trapezoidal windows
Fmin ≤ YStart for rectangular windows
Frelmin ≤ YStart for trapezoidal windows

and for Smax (if Smax is reached) must apply

Y < Fmin for rectangular windows


Y < Fmin (Smax) for trapezoidal windows

and Smin ≤ SStart

Page 80 002-518-3e-01.14
Evaluation of the Measured Values

backward
Ymax ≤ Fmax for rectangular windows
Ymax ≤ Frelmax for trapezoidal windows
Fmin ≤ YStart for rectangular windows
Frelmin ≤ YStart for trapezoidal windows

and for Smin (if Smin is reached) must apply

Y < Fmin for rectangular windows


Y < Fmin (Smin) for trapezoidal windows

and SStart ≤ Smax

NOK
The joining operation is evaluated NOK if:

the curve exceeds Fmax (Frelmax )

Fmax < Ymax for rectangular windows

Frelmax < Ymax for trapezoidal windows

or
the curve violates the left edge of the window at Smin

Fmin < Y(Smin) for rectangular windows

Fmin (Smin) < Y(Smin) for trapez. windows

In this case Actual-min and Actual-max are highlighted


black in the table.

or
the curve violates the right edge of the window at Smax

Fmin < Y(Smax) for rectangular windows

Fmin (Smax) < Y(Smax) for trap. windows

In this case Actual-min and Actual-max are highlighted


black in the table.

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

or if it ends inside the window.

002-518-3e-01.14 Seite 81
Contents

6.2.13 Window Type 10: Snap Window, Peak Window at the Bottom
5B

The snap window, peak window at the bottom can be


used to monitor the joining of lock rings or sealing rings
depending on the application. (e.g. extension measure-
ment). The window can be activated for a certain direction
of movement, e.g. only forward or only backward, as well
as both directions at the same time (forward & backward).
It is also possible to parameterize the window trapezoid-
shaped.

OK-measurement with
Y rectangular window

Fmax
Y Measured values: table
1 Pr. Actual values Set points
0 min max min max Forw.
Ymin 1 Ymin Fmin kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax)

Measured values: table


Fmax (Smin) Pr. Actual values Set points
1 0 min max min max Forw.
Fmin(Smax)
1 Ymin Frelmin kN
Ymin
Frelmin
Fmin (Smin)

Smin Smax X

In trapezoidal windows always the minimum space be-


tween the measuring curve and the adjoining upper edge
of the window is defined as Actual-value min. The mini-
mum value of the border at the corresponding waypoint
is displayed as set point.

Page 82 002-518-3e-01.14
Evaluation of the Measured Values

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smin) 1 Ymin Frelmin kN
1
Fmin(Smax)
Frelmin
Fmin (Smin)
Ymin The violation is highlighted black in the
table.
Smin Smax X

NOK-measurement with
Y trapezoidal window
Fmax (Smax)
Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smin) 1 Ymin Ymax Frelmin Fmax* kN
Ymax
1
Fmin(Smax)
* Fmax equals here Fmax (Smin)
Ymin
Frelmin
Fmin (Smin)
The violation is highlighted black
in the table.
Smin Smax X
If both edges are violated the extremer
one is displayed.

When window type 10 is used for backward movement


the same conditions apply (diagram see window type 1).

002-518-3e-01.14 Seite 83
Contents

OK
The curve must pass above the lower edge of the window.
It must not violate the left and the right edges of the win-
dow. The curve must start and end outside of the window.
At least one measuring point must be found inside the
window. The direction of movement must not be violated.

Fmin < Y for rectangular windows


Frelmin < Y for trapezoidal windows

and for Smin (if Smin is reached) must apply

Fmax < Y for rectangular windows


Fmax (Smin) < Y for trapezoidal windows

and for Smax (if Smax is reached) must apply

Fmax < Y for rectangular windows


Fmax (Smax) <Y for trapezoidal windows

NOK
The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y < Fmin for rectang. windows

Y < Frelmin for trapez. windows


or
the curve violates the left edge of the window at Smin

Y(Smin) < Fmax for rect. windows

Y(Smin) < Fmax (Smin) for trap. windows


or
the curve violates the right edge of the window at Smax

Y(Smax) < Fmax for rectangular windows

Y(Smax) < Fmax (Smax) for trap. windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

or if it starts or ends in the window.

Page 84 002-518-3e-01.14
Evaluation of the Measured Values

6.2.14 Window Type 11; End Window at the Bottom


56B

Depending on the application the end window at the bot-


tom can be used to monitor the end point of the curve.
The window can be activated for a certain direction of
movement, e.g. only forward or only backward. It is also
possible to parameterize the window trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax
Measured values: table
1 Pr. Actual values Set points
YEnde
0 min max min max Forw.
Ymin
1 Ymin YEnde Fmin Fmax kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax)
Frelmax Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smin) 1 Ymin YEnde Frelmin Frelmax kN
YEnde 1
Fmin(Smax)
Ymin
Frelmin
Fmin (Smin)

Smin Smax X

In trapezoidal windows always the minimum space bet-


ween the curve and the adjoining upper edges of the
window is determined as Actual value min. The minimum
value of the border at the corresponding waypoint is
displayed as set point.

002-518-3e-01.14 Seite 85
Contents

NOK-measurement with
Y trapezoidal window
Fmax (Smax) Measured values: table
Frelmax Pr. Actual values Set points
0 min max min max Forw.
1 Ymin YEnde Frelmin Frelmax kN
Fmax (Smin)
YEnde 1
Fmin (Smax)
Frelmin The violation is highlighted black in the
Fmin (Smin)
table.
Ymin
Smin Smax X

NOK-measurement with
Y trapezoidal window
Fmax (Smax) Measured values: table
YEnde
Frelmax Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smin) 1 1 Ymin YEnde Frelmin Frelmax kN

Fmin(Smax)
Ymin
Frelmin
Fmin (Smin) The violation is highlighted black in the
table.
Smin Smax X

The same conditions apply when window type 11 is used


for backward movement (diagram see window type 1).

OK
The curve must end inside the window, whereby the curve
must pass above the lower edge of the window and must
not violate the left and right edges of the window. The
curve must start outside of the window. At least one
measuring point must be found inside the window and the
direction of movement must not be violated

forward
Fmin ≤ Y for rectangular windows
Frelmin ≤ Y for trapezoidal windows
YEnde ≤ Fmax for rectangular windows
YEnde ≤ Frelmax for trapezoidal windows

and for Smin (if Smin is reached) must apply

Fmax < Y for rectangular windows


Fmax(Smin) < Y for trapezoidal windows

Page 86 002-518-3e-01.14
Evaluation of the Measured Values

Backward
Fmin ≤ Y for rectangular windows
Frelmin ≤ Y for trapezoidal windows
YEnde ≤ Fmax for rectangular windows
YEnde ≤ Frelmax for trapezoidal windows

and for Smax (if Smax is reached) must apply

Fmax < Y for rectangular windows


Fmax(Smax) < Y for trapezoidal windows

NOK
The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y < Fmin for rectang. windows

Y < Frelmin for trapez. windows

or
the curve violates the left edge of the window at Smin

Y(Smin) < Fmax for rectangular windows

Y(Smin) < Fmin (Smax) for trapez. windows

or
the curve violates the right edge of the window at Smax

Y(Smax) < Fmax for rectangular windows

Y(Smax) < Fmax (Smax) for trap. windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the X-
resolution).

or if it starts inside the window or does not end inside the


window.

002-518-3e-01.14 Seite 87
Contents

6.2.15 Window Type 12; Start Window at the Bottom


57B

Depending on the application the start window at the bot-


tom can be used to monitor the start point of the curve.
The window can be activated for a certain direction of
movement, e.g. only forward, or only backward. It is also
possible to parameterize the window trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax
Measured values: table
YStart 1
Pr. Actual values Set points
Ymin 0 min max min max Forw.
1 Ymin YStart Fmin Fmax kN
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smin)
Frelmax
YStart Measured values: table
1 Pr. Actual values Set points
Fmax (Smax) 0 min max min max Forw.
Ymin Ymin YStart
1 Frelmin Frelmax kN
Fmin(Smin)
Frelmin
Fmin (Smax)

Smin Smax X

In trapezoidal windows always the minimum space from


the curve to the adjoining lower edges of the window is
defined as Actual value min. As set point the minimum
value of the border at the corresponding waypoint is
displayed. For Actual value max and set point value max
the display is analogous to the respective max values.

Page 88 002-518-3e-01.14
Evaluation of the Measured Values

NOK-measurement with
Y trapezoidal window
Fmax (Smin)
Frelmax Measured values: table
YStart Pr. Actual values Set points
1 0 min max min max Forw.
Fmax (Smax) 1 Ymin YStart Frelmin Frelmax kN

Fmin(Smin)
Ymin Frelmin
Fmin (Smax) The violation is highlighted black in the
table.
Smin Smax X

NOK-measurement with
Y trapezoidal window
YStart
Fmax (Smin) Frelmax
Measured values: table
1 Pr. Actual values Set points
Fmax (Smax) 0 min max min max Forw.
1 Ymin YStart Frelmin Frelmax kN
Ymin
Fmin(Smin)
Frelmin
Fmin (Smax) The violation is highlighted black in the
table.
Smin Smax X
If the start point is outside the displacement range Smin –
Smax, X.XX is displayed as Actual value and -.- - as set
point.

When window type 12 is used for backward movement


the same conditions apply (diagram see window type 1).

OK
The curve must start inside the window, whereby the curve
must pass above the lower edge of the window and must
not violate the left and right edges of the window. The
curve must end outside the window. At least one measur-
ing point must be found inside the window, and the direc-
tion of movement must not be violated.

forward
Fmin ≤ Y for rectangular windows
Frelmin ≤ Y for trapezoidal windows
YStart ≤ Fmax for rectangular windows
YStart ≤ Frelmax for trapezoidal windows

and for Smax (if Smax is reached) must apply


Fmax < Y for rectangular windows
Fmax(Smax) < Y for trapezoidal windows

002-518-3e-01.14 Seite 89
Contents

backward
Fmin ≤ Y for rectangular windows
Frelmin ≤ Y for trapezoidal windows
YStart ≤ Fmax for rectangular windows
YStart ≤ Frelmax for trapezoidal windows

and for Smin (if Smin is reached ) must apply

Fmax < Y for rectangular windows


Fmax(Smin) < Y for trapezoidal windows

NOK
The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y < Fmin for rectangular windows

Y < Frelmin for trapezoidal windows

or
the curve violates the left edge of the window at Smin

Y(Smin) < Fmax for rectangular windows

Y(Smin) < Fmin (Smax) for trapez. windows

or
the curve violates the right edge of the window at Smax

Y(Smax) < Fmax for rectangular windows

Y(Smax) < Fmax (Smax) for trap. windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

or
if it ends inside the window or does not start inside the
window.

Page 90 002-518-3e-01.14
Evaluation of the Measured Values

6.2.16 Window Type 13; Reverse Window – Right


58B

The reverse window can be used to monitor the reverse,


end or start point in horizontal direction, at the same time
the borders are determined by a minimal- and maximal
force. The window can be activated for a certain direction
of movement, e.g. only forward (end point) or only back-
ward (start point) or both directions (reverse point). It is al-
so possible to parameterize the window trapezoid-shaped.

OK-measurement at forward
Y and backward movement

Fmax Measured values: table


Pr. Actual values Set points
0 min max min max Forw.
1 Xmax Smin Smax mm
Fmin

Measured values: table


Pr. Actual values Set points
0 min max min max Backw.
Smin Xmax Smax X 1 Xmin Smin Smax mm
Xmin
Blue= forward, orange= backward

With the ENTER key you can switch between


the display forward and backward.

002-518-3e-01.14 Seite 91
Contents

OK-measurement for forward Measured values: table


Y and backward movements Pr. Actual values Set points
Fmax(Smin) 0 min max min max Forw.
1 Xmax Smin Smax mm
Fmax(Smax)

Measured values: table


Fmin(Smax) Pr. Actual values Set points
Fmin(Smin) 0 min max min max Backw.
1 Xmax Smin Smax mm

Smin Xmax Smax X


Xmax

Blue= forward, orange= backward

With the ENTER key you can switch between


the display forward- and backward

NOK-measurement for Measured values: table


Y forward movement Pr. Actual values Set points
0 min max min max Forw.
Fmax 1 Xmax Smin Smax mm

Fmin
The violation is highlighted black in the
table.

If the endpoint is outside the window


Smin Xmax Smax X X.XX is displayed as Actual value and
-.- - as set point.

Page 92 002-518-3e-01.14
Evaluation of the Measured Values

OK
The curve must pass between the upper and lower edges
of the window and must not violate the right edge of the
window. At least one measuring point must be found in-
side the window, and the direction of movement must not
be violated

Forward movement: the curve must end inside the window

Fmin ≤ Y ≤ Fmax for rectangular windows

Frelmin ≤ Y ≤ Frelmax for trapez. windows

and Smin < Xmax < Smax

Backward movement: the curve must start inside the win-


dow

Fmin ≤ Y ≤ Fmax for rectangular windows

Frelmin ≤ Y ≤ Frelmax for trapez. windows

and Smin < Xmax < Smax

NOK
The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y < Fmin for rectang. windows

Y < Frelmin for trapez. windows

the curve exceeds Fmax (Frelmax )

Fmax < Y for rectang. windows

Frelmax < Y for trapez. windows


or
the curve violates the right edge of the window at Smax

Smax < X

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

002-518-3e-01.14 Seite 93
Contents

6.2.17 Window Type 14; Reverse Window – Left


59B

The reverse window can be used to monitor the reverse,


end or start point in horizontal direction, at the same time
the borders are determined by a minimal- and maximal
force. The window can be activated for a certain direction
of movement, e.g. only forward (end point) or only back-
ward (start point) or both directions (reverse point). It is al-
so possible to parameterize the window trapezoid-shaped.

OK-measurement for forward-


Y & backward movement Measured values: table
Pr. Actual values Set points
Fmax 0 min max min max Forw.
1 Xmin Smin Smax mm

Fmin Measured values: table


Pr. Actual values Set points
0 min max min max Backw.
1 Xmin Smin Smax mm

Smin Xmin Smax X


Xmin

Blue = forward, orange = backward

With the ENTER key you can switch between


the display forward and backward.

Page 94 002-518-3e-01.14
Evaluation of the Measured Values

OK-measurement for forward- Measured values: table


Y & backward movement Pr. Actual values Set points
Fmax(Smax) 0 min max min max Forw.
Fmax(Smin) 1 Xmin Smin Smax mm

Measured values: table


Pr. Actual values Set points
Fmin(Smin)
0 min max min max Backw.
Fmin(Smax) 1 Xmin Smin Smax mm

Smin Xmin Smax X


Xmin

Blue = forward, orange = backward

With the ENTER key you can switch between


the display forward and backward.

NOK-measurement for
Y foward movement
Measured values: table
Fmax Pr. Actual values Set points
0 min max min max Forw.
1 Xmin Smin Smax mm

Fmin
The violation is highlighted black in the
table

Smin Xmin Smax X If the end point is outside the window


X.XX is displayed as actual value and
-.- - as set point.

002-518-3e-01.14 Seite 95
Contents

OK
The curve must pass between the upper and lower edges
of the window and must not violate the left edge of the
window. At least one measuring point must be found in-
side the window, and the direction of movement must not
be violated

forward: the curve must start inside the window

Fmin ≤ Y ≤ Fmax for rectangular windows

Frelmin ≤ Y ≤ Frelmax for trapez. windows

and Smin < Xmin < Smax

backward: the curve must start inside the window

Fmin ≤ Y ≤ Fmax for rectangular windows

Frelmin ≤ Y ≤ Frelmax for trapez. windows

and Smin < Xmin < Smax

NOK
The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y < Fmin for rectang. windows


Y < Frelmin for trapez. windows

the curve exceeds Fmax (Frelmax )

Fmax < Y for rectang. windows


Frelmax < Y for trapez. windows

or
the curve violates the right edge of the window at Smin

X < Smin
or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

Page 96 002-518-3e-01.14
Evaluation of the Measured Values

6.2.18 Window Type 15; Limitation Window at the Bottom-Left


60B

The limitation window at the bottom – left can be activat-


ed for a certain direction of movement, e.g. only forward
or only backward, and for both directions at the same time
(forward & backward). It is also possible to parameterize
the window trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax Measured values: table


1 Pr. Actual values Set points
0 min max min max Forw.
Ymin 1 Ymin Fmin kN
Fmin

Smin Smax X

OK-measurement with
trapezoidal window
Y
Fmax (Smin)
Measured values: table
Pr. Actual values Set points
Fmax (Smax) 0 min max min max Forw.
1 Ymin Frelmin kN
Ymin
Fmin(Smin) 1
Frelmin
Fmin (Smax)

Smin Smax X

In trapezoidal windows always the minimum space be-


tween the curve and the adjoining lower edges of the
window are defined as Actual value min. The minimum
value of the border at the corresponding waypoint is
displayed as set point

002-518-3e-01.14 Seite 97
Contents

NOK-measurement with
Y trapezoidal window
Fmax (Smin) Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
1 Ymin Frelmin kN
Fmax (Smax)
1
Fmin(Smin) Frelmin
The violation is highlighted black in the
Ymin table.
Fmin (Smax)

Smin Smax X

NOK-measurement with
Y trapezoidal window
Fmax (Smin) Measured values: table
Pr. .
Actual values Set points
Ymax 0 min max min max Forw.
1 Ymin Ymax Frelmin Fmax * kN
Fmax (Smax)
1 * Fmax equals here Fmax (Smin)
Fmin(Smin)
Ymin
Frelmin

Fmin (Smax) The violation is highlighted black in the


table.
Smin Smax X

When the window type 15 is used for backward move-


ment the same conditions apply (diagram see window type
1).

Page 98 002-518-3e-01.14
Evaluation of the Measured Values

OK
The curve must pass above the lower edge of the window
and must not violate the left edge of the window. The
curve may start or end inside the window. At least one
measuring point must be found inside the window, and the
direction of movement must not be violated

forward

Fmin ≤ Y for rectangular windows

Frelmin ≤ Y for trapezoidal windows

and for Smin (if Smin is reached) must apply

backward

Fmax < Y for rectangular windows

Fmay (Smin) < Y for trapezoidal windows

NOK
The joining operation is evaluated NOK if:

the curve remains below Fmin (Frelmin )

Y < Fmin for rectangular windows

Y < Frelmin for trapezoidal windows

or
the curve violates the right edge of the window at Smin

Y(Smin) < Fmax for rectangular windows

Y(Smin) < Fmax(Smin) for trapez. windows

or
if there is no measuring point inside the window (this also
applies, if .e.g. the window is activated for forward, and it
is passed through only backward; or vice-versa, if the win-
dow is activated for backward and is passed through only
forward; or if the window is to small in ratio of the
X-resolution).

002-518-3e-01.14 Seite 99
Contents

6.2.19 Window Type 16; Displacement Window Left

For the evaluation of a min. achieved travel path, inde-


pendent of the joining force which occurred. The minimum
displacement traveled Xmin (the displacement end) is saved
and evaluated according to Smin and Smax.

Only backward Backward-forward


measurement measurement
Y 1 Y 1

Smin Xmin Smax X Smin Xmin Smax X

Measured values: table


Pr. Actual values Set points
0 min max min max Backw.
1 Xmin Smin Smax mm

OK
The curve may either end inside the displacement window
or exit the window on the Smin side.

Fmin ≤ Xmin ≤ Fmax

NOK
The joining operation is evaluated NOK if:

the curve ends or returns before it has reached Smax

Smax < Xmin

or
the curve remains below Smin.

Xmin < Smin

Page 100 002-518-3e-01.14


Evaluation of the Measured Values

Smin and Smax using teach-in

Selection Mastercheck will fit window… must be ac-


tivated. At submenu window definition the input of Smin
and Smax will be done as input of absolute values. The dis-
tance between Smin and Smax defines the size of the window.
Starting measurement using input master control teach-in
function will be activated and the window will be placed at
the end of displacement.

Before measurement After measurement


mastercheck mastercheck

Y Y
= =

Smin Smax X Smin Xmin Smax X

After measurement Mastercheck the window is placed at


the minimal reached displacement Xmin symmetrical.

Using normal measuring, the window Type 0 acts like hav-


ing absolute values for borders of window.

Applications using master sample function and its check


starting measuring by input master control, the window
must be placed absolute. It is recommended to generate
a own program for this function with a window having
absolute borders.

002-518-3e-01.14 Seite 101


Contents

6.2.20 Window Type 17; Force Window Minimum


62B

For the evaluation of a min. achieved joining force Ymin, in-


dependent of the displacement traveled. The minimum of
the complete curve is saved and evaluated according to
Fmin and Fmax.

Measurement ends Measurement continues

Y Y

Fmax Fmax
Ymin Ymin

Fmin Fmin

X X

Measured values: table


Pr. Actual values Set points
0 min max min max Forw.
1 Ymin Fmin Fmax N

OK
The curve may either end in the force window or exit the
window on the Fmin-side.

Fmin ≤ Ymin ≤ Fmax

NOK
The joining operation is evaluated NOK if:

the curve ends before it has reached Fmax or has its max.
vertex

Fmax < Ymin


or
the curve remains below Fmin

Ymin < Fmin

Page 102 002-518-3e-01.14


Evaluation of the Measured Values

Fmin and Fmax using teach-in

Selection Mastercheck will fit window… must be ac-


tivated. At submenu window definition the input of Fmin
and Fmax will be done as input of absolute values. The dif-
ference between Fmin and Fmax defines the size of the win-
dow. Starting measurement using input master control
teach-in function will be activated and the window will be
placed at the minimum of force

Before measurement After measurement


mastercheck mastercheck

Y Y
Fmax

Fmin Fmax
=
Ymax
Fmin
=

X X

After measurement Mastercheck the window is placed at


the minimal reached force Fmin symmetrical.

Using normal measuring, the window Type 0 acts like hav-


ing absolute values for borders of window.

6.2.21 Window Type 18; Combined Start-End-Window


63B

With the combined start-end-window, optionally the start-


ing or ending point of trace can be monitored. The selec-
tion is made in the submenu window definition of the set
value entry. If the selection is made for start window, only
the starting point is monitored. Without selection, only the
ending point is monitored. The window can be activated
for a certain direction of movement, e.g. only forward or
only backward. Different to the window types 11 to 14,
the monitoring is exclusively effected for the starting and
ending point of the trace; for this it is completely negligible
how often the window edge is cut by the curve.

Window type 18 is basically a rectangle window


(not available as trapezoid window).

002-518-3e-01.14 Seite 103


Contents

Monitoring of Starting Point, Selection Start Window

X-value display (display x )


Measured values: table
OK−measurement with
Y Pr. Actual values Set points
rectangular window
0 min max min max Forw.
1 XStart XStart smin smax mm
Fmax
YStart 1
Y- value display (display x )

Measured values: table


Fmin Pr. Actual values Set points
0 min max min max Forw.
1 YStart YStart Fmin Fmax kN

On selection of direction of force traction


Smin Smax X &compression, the respective minimum and maxi-
XStart mum value of YStart is display for the current value
min and max.

X- value display (display x )

Measured values: table


NOK–measurement with
Y Pr. Actual values Set points
rectangular window
0 min max min max Forw.
1 YStart YStart Frelmin Frelmax kN
Fmax
1 Y- value display (display x )

Measured values: table


Fmin Pr. Actual values Set points
0 min max min max Forw.
YStart 1 XStart XStart smin smax mm

Smin Smax X The table entry with the violation will be high-
lighted in black.
XStart

Page 104 002-518-3e-01.14


Evaluation of the Measured Values

NOK–measurement with X- value display (display x )


Y rectangular window Measured values: table
Pr. Actual values Set points
Fmax 0 min max min max Forw.
1 1 XStart XStart smin smax mm
YStart

Fmin Y- value display (display x )


Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
1 YStart YStart Frelmin Frelmax kN
Smin Smax X
XStart

NOK–measurement with X- value display (display x )


Y rectangular window Measured values: table
Pr. Actual values Set points
Fmax 0 min max min max Forw.
1 1 XStart XStart smin smax mm
YStart

Fmin Y- value display (display x )


Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
1 YStart YStart Frelmin Frelmax kN
Smin Smax X
XStart

NOK–measurement with X- value display (display x )


Y rectangular window Measured values: table
YStart Pr. Actual values Set points
Fmax 0 min max min max Forw.
1 1 XStart XStart smin smax mm

Fmin Y- value display (display x )


Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
1 YStart YStart Frelmin Frelmax kN
Smin Smax X
XStart

If the starting point lies outside of the x-coordinate as well


as of the y-coordinate of the window, independent from
the chosen display, both table entries are highlighted in
black. For the usage of window type 18 for backward
movement, the same requirements apply (illustration see
window type 1).

002-518-3e-01.14 Seite 105


Contents

OK
The starting point must be positioned within the window.

Fmin ≤ YStart
YStart ≤ Fmax
and
XStart ≤ Smax
Smin ≤ XStart

NOK
The joining operation will be marked as NOK if the starting
point is not positioned within the window.

YStart < Fmin

YStart > Fmax

or
XStart < Smin

XStart > Smax

or the combination of both cases

Monitoring of Ending Point, Selection Starting Window


X- value display (display x )

OK–measurement with Measured values: table


Y rectangular window Pr. Actual values Set points
0 min max min max Forw.
Fmax 1 XEnd XEnd smin smax mm

YEnd 1
Y- value display (display x )

Fmin Measured values: table


Pr. Actual values Set points
0 min max min max Forw.
1 YEnd YEnd Fmin Fmax kN
Smin Smax X
XEnd
On selection of direction of force traction&compression,
the respective minimum and maximum value of YStart is dis-
played for the current value min and max.

In the case of violation of the conditions of the end win-


dow, the table entries are highlighted in black according to
the starting window.

Page 106 002-518-3e-01.14


Evaluation of the Measured Values

OK
The ending point must be positioned within the window.

Fmin ≤ YEnd
YEnd ≤ Fmax
and
XEnd ≤ Smax
Smin ≤ XEnd

NOK
The joining operation will be marked as NOK if the ending
point is not positioned within the window.

YEnd < Fmin

YEnd > Fmax

or

XEnd < Smin

XEnd > Smax

or the combination of both cases.

002-518-3e-01.14 Seite 107


Contents

6.2.22 Window Type 20; Speed Window


64B

for monitoring the joining speed between the borders Vmin


and Vmax alongside the displacement between Smin and Smax.

1
Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
1 Vmin Vmax Vmin Vmax mm/s

Smin Smax X

OK
The speed between the borders Vmin and Vmax alongside the
displacement between Smin and Smax

Vmin ≤ V ≤ Vmax

NOK
The joining operation is evaluated NOK if:

The value between Smin and Smax is below Vmin

V < Vmin
or
Vmax is exceeded between Smin and Smax

V > Vmax

6.2.23 Window Type 21; reserved


65B

6.2.24 Window Type 22; reserved


6B

Page 108 002-518-3e-01.14


Evaluation of the Measured Values

6.2.25 Window Type 23; Gradient Window


67B

For monitoring the gradient dy/dx (of rise of the curve)


alongside the displacement between Smin and Smax . Win-
dow can be configured in two different evaluation modes:
 Window for OK/NOK evaluation
 Window for online-Triggers (YTE) releasing

6.2.25.1 Gradient Window for OK/NOK Evaluation


108B

At submenu window definition activate OK/NOK and


deactivate YTE

For details for input of set points refer to chapter 7.1.1,


submenu window definition and for details of display
refer to chapter 6.3.2, menu diagram.

Y 1
Measured values: table
Pr. Actual values Set points
gradmax 0 Forw.
min max min max
1 gradmin gradmax gradmin gradmax KN/mm

gradmin

gradmax
Δymax
Smin Smax X gradmin
Δymin

Δx Δx

Δy
Polarity of ∆x
Δx
grad = Δy/Δx Trace forward travel:
movement left to right +,
right to left –
NOK-measurement
Trace back travel:
gradient window
movement left to right +,
Y 1 right to left –
gradmax
Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
1 gradmin gradmax gradmin gradmax KN/mm
gradmax
gradmin
gradmin

Smin Smax X

002-518-3e-01.14 Seite 109


Contents

OK
Gradient along Smin to Smax (forward) or Smax to Smin (back-
ward) must be between limits gradmin and gradmax:

gradmin ≤ grad ≤ gradmax

NOK
The joining operation is evaluated NOK if:

grad is below gradmin along Smin and Smax

grad < gradmin


or
grad exceeds gradmax along Smin and Smax

grad > gradmax

6.2.25.2 Gradient Window for Online-Trigger (YTE)


109B

At submenu window definition activate OK/NOK and


deactivate YTE

As soon as for the first time in this pre-determined way-


section the rise of the curve itself is within a pre-
determined interval [gradmin, gradmax], an Online-Trigger
(YTE) is activated.
The Gradient point is determined in real-time (“on-line”)
during the measurement.

In this case the gradient window has no influence on the


result of evaluation, only a trigger function. It will not be
displayed in the measured values table. The gradient
point is displayed in the diagram only.

Y 1
Δy

Δx

grad = Δy/Δx

Polarity of ∆x
Trace forward travel:
Movement left to right +,
right to left –
Smin Smax X Trace backward travel:
Movement left to right +,
right to left –

Page 110 002-518-3e-01.14


Evaluation of the Measured Values

Online-trigger YTE is activated if:

gradmin between Smin and Smax is reached or exceeded

and
gradmax between Smin and Smax is not exceeded

gradmin ≤ grad ≤ gradmax

Y 1
gradmax
Δymax
YTE
Δx

gradmin
Δymin

Δx
Smin X

For further details about the input of set point values


please refer to chapter 7.1.1, submenu window definition
and for details about the presentation see chapter 6.3.2,
diagram menu.
If a gradient point is found the bit 2 (GRAD) is set in the
second byte of the status word, see communication
manual.

If both OK/NOK and YTE are not activated, the search


for gradient point is still done like activated trigger. A
found point will be displayed in diagram. Details for
display refer chapter 6.3.2, menu diagram. Output YTE
will be not set.

002-518-3e-01.14 Seite 111


Contents

6.2.26 Window Type 24; Breakpoint Window


68B

The breakpoint window allows a detection of a clear altera-


tion of the gradient dy/dx (of the ascending gradient of
the curve) alongside the distance between Smin and Smax.
Depending on the parameter setting of set points a break-
point or break-recognition can be carried out.
In the case of the breakpoint-recognition, a breakpoint of
the distance between Smin und Smax within the window
borders ymin and ymax is expected, and is required for an OK
evaluation.
With the break-recognition, no breakpoint can be recog-
nized for an OK evaluation, it plays no role with it, whether
the break in the interval between Smin and Smax lies with-
in the window-borders ymin and ymax or above or below
them.
The selection between pure breakpoint – or break-
recognition takes place through the default setting of the
Trigger offset, (see also input in the submenu window-
definition). Trigger offset≠ 0 for pure breakpoint recogni-
tion, trigger offset = 0 for break recognition
The breakpoint is defined through the alteration of ascend-
ing gradient. The alteration of ascending gradient Δgrad is
calculated from the rises in two way sections with the
Δy length Δx before the actual measuring point P
Δx 2
Signs of ∆x
Δy at forward curve:
1 Movement from left to right +, from right to left –
Δx at backward curve:
Movement from left to right +, from right to left –
Δgrad = grad2 – grad1
= Δy2/Δx – Δy1/Δx The breakpoint is defined during the measurement in real
time ("online").

After the recognition of a breakpoint a signal output (one


of the general trigger outputs XTE or XTE) is set in real time
under the following conditions:

Breakpoint control Break control


(Trigger offset ≠ 0) (Trigger offset = 0)
Dimension unit: x (mm, .. ) XTE set after x-Offset YTE set immediately
Dimension unit: y (kN, ..) YTE set after y-Offset

The trigger is activated with breakpoint control only if the


determined breakpoint lies in y-direction within the win-
dow, i.e. will be evaluated OK.

If a breakpoint is found the Bit 3 (BREAK) is set in the 2.


byte of the status word, see communication manual.

Page 112 002-518-3e-01.14


Evaluation of the Measured Values

Breakpoint Recognition with Trigger Offset in X-Direction


OK-measurement
Additional input:
Y ∆x, Δgradmin , Δgradmax, Trigger offset ≠ 0,
XTE Trigger offset unit
Fmax
YKnick 1
Measured values: table
Pr. Actual values Set points
Fmin 0 min max min max Forw.
1 YKnick Fmin Fmax kN

Smin Smax X
Trigger offset
Breakpoint

NOK-measurement
Y
Measured values: table
YKnick
Pr. Actual values Set points
Fmax
0 min max min max Forw.
1
1 YKnick Fmin Fmax kN

Fmin XTE is not set!

Smin Smax X
Trigger offset
Breakpoint

Breakpoint recognition with trigger offset in Y-direction

OK-measurement
Additional input:
Y ∆x, Δgradmin , Δgradmax, Trigger offset ≠ 0,
YTE Trigger offset unit
Fmax
Trigger 1 Measured values: table
offset Pr. Actual values Set points
YKnick 0 min max min max Forw.
Fmin 1 YKnick Fmin Fmax kN

Smin Smax X
Breakpoint

002-518-3e-01.14 Seite 113


Contents

OK breakpoint recognition

In the range of Smin to Smax a breakpoint must be recog-


nized in which the alteration of gradient Δgrad lies in the
interval Δgradmin and Δgradmax. The breakpoint force must
not violate the upper and lower edge of the window. The
curve may start and or end in the window.

if Δgradmin ≤ Δgrad ≤ Δgradmax is reached, the following


applies:

Fmin ≤ YKnickl ≤ Fmax

NOK Breakpoint recognition

The joining operation is considered faulty if:

no breakpoint was recognized

Δgradmin > Δgrad


or
Δgradmax < Δgrad
or
The force at the breakpoint YKnick violates the upper edge
of the window

Fmax < YKnick

or
the force at the breakpoint YKnick violates the lower edge of
the window

Fmin > YKnick

Page 114 002-518-3e-01.14


Evaluation of the Measured Values

Break recognition

NOK-measurement
Additional input:
Y ∆x, Δgradmin , Δgradmax, Trigger offset = 0,
Trigger offset unit
YTE
Fmax
YKnick 1
Measured values: table
Pr. Actual values Set points
Fmin 0 min max min max Forw.
1 YKnick Fmin Fmax kN

Smin Smax X

OK break recognition
In the range of Smin to Smax no breakpoint must be recog-
nized, of which the alteration of gradient Δgrad lies in the
interval Δgradmin and Δgradmax . The curve may start and or
end in the window.

Δgradmin > Δgrad or Δgradmax < Δgrad

NOK break recognition


The joining operation is considered faulty if a breakpoint
was recognized:

Δgradmin ≤ Δgrad ≤ Δgradmax

Here it is irrelevant if the force at the breakpoint YKnick vio-


lates the upper edge of the window,

Fmax < YKnick

or
the force at the breakpoint YKnick violates the lower edge of
the window.

Fmin > YKnick

002-518-3e-01.14 Seite 115


Contents

6.2.27 Window Type 25; Reserved

6.2.28 Window Type 26; Reserved

6.2.29 Window Type 27; Localized Displacement Monitoring


71B

Monitoring of a displacement point within a defined toler-


ance at a specified force. Evaluation takes always the first
point inside the tolerance band on which the specified
force exceeded or fallen below. The position of the win-
dow can be defined by absolute values of Fpos , Spos and
tolerance Stol or using teach-in for Spos. Details for input of
set points refer (7.1.1), submenu window definition

Fpos , Spos and Stol absolute input

Measurement forward
Y
Spos Measured values: table
Pr. Actual values Set points
1 0 min max min max Forw.
Fpos
Spos – Spos + mm
1 Xmax
Stol Stol

Spos - Stol Spos + Stol X


Xmax

Measurement forward Evaluation takes always the first point which the specified
Y force exceeded or fallen below. Forward it is the most left
point, backward it is the most right point.
Spos

Fpos 1

Spos - Stol Spos + Stol X


Xmax

Page 116 002-518-3e-01.14


Evaluation of the Measured Values

Measured values: table


Measurement forward-backward Pr. Actual values Set points
Y 0 min max min max Forw.
Spos – Spos + mm
Spos 1 Xmax
Stol Stol
1
Fpos
Measured values: table
Pr. Actual values Set points
0 min max min max Backw.
Spos – Spos + mm
1 Xmax
Stol Stol

Spos - Stol Spos + Stol X blue = forward, orange = backward


Xmax Xmax

With the ENTER key you can switch between


the display forward and backward.

NOK-Measurement - forward
Y Spos

1 Measured values: table


Fpos Pr. Actual values Set points
0 min max min max Forw.
Spos – Spos + mm
1 Xmax
Stol Stol

Spos - Stol Spos + Stol X


Xmax

NOK-Measurement - forward
Y
Spos
Measured values: table
1 Pr. Actual values Set points
Fpos 0 min max min max Forw.
Spos – Spos + mm
1 Xmin
Stol Stol

If the specified force is not reached X.XX will be


displayed as actual value.
Spos - Stol Spos + Stol X
Xmin

002-518-3e-01.14 Seite 117


Contents

OK
The measured trace have to exceed or fallen below the
specified force Fpos between Spos - Stol until Spos + Stol.

At Fpos : Spos - Stol ≤ X ≤ Spos + Stol

NOK
The joining operation is evaluated NOK if:

the trace exceeds or falls below of force Fpos before reach-


ing Spos - Stol

If at Fpos:
X < Spos - Stol

or
the trace exceeds or falls below of force Fpos after reaching
Spos + Stol

If at Fpos:
Spos - Stol < X

or
the trace does not exceed or fall below of force Fpos.

Page 118 002-518-3e-01.14


Evaluation of the Measured Values

Spos using teach-in

Selection Mastercheck overwrites displ. setpoint


must be activated. At submenu window definition input of
Fpos and Stol as absolute value is done (Spos can be 0). Start-
ing a measurement mastercheck by input mastercontrol
will place the window.

Before measurement After measurement


mastercheck Y mastercheck
Y

Fpos

= =

-Stol +Stol X Spos X

After measurement Mastercheck the window is placed at


the displacement were the trace crosses Fpos symmetrical
and Spos fixed.

Using normal measuring, the window type 27 acts like


having absolute values for borders of window.

002-518-3e-01.14 Seite 119


Contents

6.2.30 Window Type 28; Localized Force Monitoring


72B

Monitoring of a force point within a defined tolerance at a


specified displacement. The position of the window can be
defined by absolute values of Spos , Fpos and tolerance Ftol or
using teach-in for Fpos. Details for input of set points refer
chapter 7.1.1, submenu window definition.

Measurement forward
Y
Fpos , Spos and Ftol absolute input
Fpos + Ftol
1
Fmax Fpos
Fpos - Ftol Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fpos – Fpos KN
1 Fmax
Ftol +Ftol

Spos X

Measurement forward
Y Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fpos + Ftol
Fmax Fpos – Fpos KN
1 1 Fmax
Fpos Ftol +Ftol
Fmax
Fpos - Ftol

Measured values: table


Pr. Actual values Set points
0 min max min max Backw.
X Fpos – Fpos KN
Spos 1 Fmax
Ftol +Ftol
blue = forward, orange = backward

With the ENTER key you can switch between


the display forward and backward.

Page 120 002-518-3e-01.14


Evaluation of the Measured Values

NOK-Measurement – forward
Y
Fmax Measured values: table
Fpos + Ftol Pr. Actual values Set points
1 0 min max min max Forw.
Fpos
Fpos – Fpos + KN
1 Fmax
Fpos - Ftol Ftol Ftol

Spos X

NOK-Measurement – forward
Y
Measured values: table
Fpos + Ftol Pr. Actual values Set points
1 0 min max min max Forw.
Fpos
Fpos – Fpos + KN
Fpos - Ftol 1 Fmin
Ftol Ftol
Fmin

Spos X

If the specified displacement is not reached X.XX will be


displayed as actual value.

OK
The measured trace have to cross the specified displace-
ment Spos between Fpos – Ftol until Fpos + Ftol.

At Spos: Fpos – Ftol ≤ F ≤ Fpos + Ftol

002-518-3e-01.14 Seite 121


Contents

NOK
The joining operation is evaluated NOK if:

the trace is below of the force Fpos – Ftol reaching Spos

If at Spos: F < Fpos – Ftol


or
the trace is over the force Fpos + Ftol reaching Spos

If at Spos: Fpos – Ftol < F

or
the trace does not reach Spos.

Fpos using teach-in

Selection Mastercheck overwrites force setpoint must


be activated. At submenu window definition input of Spos
and Ftol as absolute value is done (Fpos can be 0). Starting a
measurement mastercheck by input mastercontrol will
place the window.

Before measurement After measurement


mastercheck mastercheck
Y Y

Fpos =
=

+Ftol

-Ftol X Spos X
Spos

After measurement Mastercheck the window is placed at


the force were the trace crosses Spos symmetrical and Fpos
fixed.

Using normal measuring, the window type 28 acts like


having absolute values for borders of window.

Page 122 002-518-3e-01.14


Evaluation of the Measured Values

6.2.31 Window Type 29; Restricted Area


73B

The window "restricted area" defines a area which under


OK-conditions from trace not be reached or crossed (e.g.
hysteresis loop). The window can be activated for a certain
direction of movement, e.g. only forward or only back-
ward, and for both directions at the same time (forward &
backward). It is also possible to parameterise the window
trapezoid-shaped.

OK-measurement with
Y rectangular window

Fmax Measured values: table


1 Pr. Actual values Set points
0 min max min max Forw.
1 X.XX X.XX Smin Smax mm
Fmin

Smin Smax X

OK-measurement with
Y trapezoidal window
Fmax (Smax) Measured values: table
Pr. Actual values Set points
0 min max min max Forw.
Fmax (Smin) 1 X.XX X.XX Smin Smax mm

Fmin(Smax) 1

Fmin (Smin)

Smin Smax X

NOK-measurement with Measured values: table


Y rectangular window Pr. Actual values Set points
0 min max min max Forw.
Fmax 1 Xmin Xmax Smin Smax mm

1
Fmin X-coordinate of the most left or right inter-
section or contact point (otherwise the
window internal start or final point of the
trace) will be displayed.
Smin Xmin Xmax Smax X

002-518-3e-01.14 Seite 123


Contents

OK

The measuring trace must be above the upper window


border or below the lower window border and is not al-
lowed to violate the left or right border of the window. Not
any measured point might be inside the window.

Y < Fmin or Y > Fmax for rectangular windows

Y < Frelmin or Y > Frelmax for trapezoidal windows

NOK

The joining operation is evaluated NOK if trace contacts or


violates the window border by one or more measured
point or starts or ends inside the window.

Page 124 002-518-3e-01.14


Evaluation of the Measured Values

6.2.32 Window Type 30; MinPosition


74B

The joining window provides the monitoring of the mini-


mum value of the joining force along a stretch. The win-
dow can be activated for a certain moving direction, e.g.
only forward or only backward, as well as for both direc-
tions at the same time (forward & backward). Additionally,
it is also possible to parameterise the window trapezoidal.

The evaluation is done in the same way as on window type


1 (see there, but without live function). In contrast to win-
dow type 1, in the current value-column of the table for
measured values the minimum (for trapezoidal windows
relative minimum) of the abscissa and the y-coordinate are
displayed.

In the statistics, exclusively the analysis of this y-minimum


is effected.

In the V3-mode, only rectangle windows are possible.


The direction of movement is only forward.

OK-measurement with
Y rectangular windows
Measured values: table
Fmax Pr. Actual values Set points
0 min max min max Forw.
1 Xmin Ymin Fmin X/Y
Ymin 1
Fmin

Smin Smax X
Xmin

002-518-3e-01.14 Seite 125


Contents

OK-measurement with
Y trapezoidal window
Fmax (Smax)
Measured values: table
Pr. Actual values Set points
Fmax (Smin) 0 min max min max Forw.
1 1 Xmin Ymin Frelmin X/Y

Fmin(Smax)
Ymin
Fmin (Smin) Frelmin

Smin Smax X
Xmin

For trapezoid windows, always the minimum distance of


the gradient to the limiting upper and lower side of the
window is determined as current value. As reference
value, the maximum respectively minimum value of the
limitation at the respective waypoint is displayed.

In the case of – independent of the evaluation of the Min-


position Ymin – a Max-violation of the window, in the table
the Min-actual value (here: Xmin) will be highlighted in
black.

NIO NOK-measurement
Y with rectangular windows

Fmax

Measured values: table


Ymin 1 Pr. Actual values Set points
Fmin 0 min max min max Forw.
1 Xmin Ymin Fmin X/Y

Smin Smax X
Xmin

Page 126 002-518-3e-01.14


Evaluation of the Measured Values

6.2.33 Window Type 31; MaxPosition


75B

The joining window provides the monitoring of the maxi-


mum value of the joining force along a stretch. The win-
dow can be activated for a certain moving direction, e.g.
only forward or only backward, as well as for both direc-
tions at the same time (forward & backward). Additionally,
it is also possible to parameterise the window trapezoidal.

The evaluation is done in the same way as on window type


1 (see there, but without live function). In contrast to win-
dow type 1, in the current value-column of the table for
measured values the minimum (for trapezoidal windows
relative maximum) of the abscissa and the y-coordinate are
displayed.

In the statistics, exclusively the analysis of this y-maximum


is effected.

In the V3-mode, only rectangle windows are possible.


The direction of movement is only forward.

OK-measurement with
Y rectangular window

Fmax Measured values: table


Ymax Pr. Actual values Set points
0 min max min max Forw.
1 1 Xmax Ymax Fmax X/Y
Fmin

Smin Smax X
Xmax

OK-measurement with
Y trapezoidal window
Fmax (Smax) Measured values: table
Frelmax Pr. Actual values Set points
Ymax 0 min max min max Forw.
Fmax (Smin) 1 Xmax Ymax Frelmax X/Y
1
Fmin(Smax)

Fmin (Smin)

Smin Smax X
Xmax

002-518-3e-01.14 Seite 127


Contents

In the case of – independent of the evaluation of the Max-


position Ymax – a Min-violation of the window, in the table
the Min-current value (here: Xmax) will be highlighted in
NOK-measurement with
Y rectangular window
black.

Fmax
Ymax

1 Measured values: table


Fmin Pr. Actual values Set points
0 min max min max Forw.
1 Xmax Ymax Fmin X/Y

Smin Smax X
Xmax

6.2.34 Window Type 32; Energy Window


76B

The energy window is used to evaluate the energy (joining


respectively forming energy or work plus frictional loss),
which is transferred to the work piece via a predetermined
displacement or angle of tilt interval.

This transferred energy respectively rendered work, can be


described as integral joining force via the joining stretch re-
spectively as integral of the turning moment via the angle
of tilt::

W =  F (s) * ds resp. W=  Mt ( ) * d .

In DMF-P A300 NCF Type 4734…, the determined integral


s max
W=  F (s) * ds
s min

is calculated from the points (si, Fi) of the gradient approx-


imately by totals formation:

n
 ( Fi  Fi 1 ) 
W =  
i 1 2
* ( s i  s i 1 )

with the limits s0 = smin and sn = smax.

The window can be activated for a certain moving direc-


tion, e.g. only forward or only backward, as well as for
both directions at the same time (forward & backward)

Window type 32 is not available in V3 mode.

Page 128 002-518-3e-01.14


Evaluation of the Measured Values

Y 1 Measured values: table


Pr. Actual values Set points
0 min max min max Forw.
1 Wist Wmin Wmax kJ

In the table for measured values, the calculated


work/energy is entered as Actual value Max. If this value
under-runs the setpoint value Min or does over-run the
Smin Smax X setpoint value Max, the box Actual value Max will be high-
lighted in black (NOK value)

In the diagram, only the x-limits of the energy window are


displayed. The dimension "energy" cannot be displayed in
the y(x)-diagram, therefore a direct graphical OK/NOK-
estimation is not possible.

The area between the gradient and the x-coordinate (the


abscissa) corresponds to the transferred energy respectively
the work rendered, whereby the areas above the
x-coordinate are counted with positive prefix and areas be-
low with negative prefix – independent of the movement
of direction.

OK
The total energy in the interval of Smin – Smax must be be-
tween the limits of Wmin and Wmax

Wmin ≤ Wist ≤ Wmax

NOK
The joining operation is marked NOK, if:

Wmin in the interval Smin – Smax is under-run

Wist < Wmin

or
Wmax in the interval Smin – Smax is over-run

Wist > Wmax

002-518-3e-01.14 Seite 129


Contents

6.3 Presentation of Measured Values


30B

The measured values of the joining operation can be


shown in a table or as graphic. When presented in a table
the actual values of the curve and the set points of the tol-
erance windows are shown according to the description.
When shown as graphic the curve is displayed. Here you
can obtain a detailed view with the integrated zoom-
function

6.3.1 Menu Measured Values: Table


7B

Presentation of set point and actual values (measured val-


ues) of the previous measurement shown in a table.

Direction of
Program used movement for
for the evalua- the displayed
tion measured values

Status line

Dimension unit
of setpoint and
actual values

Status line The values of the 8 possible tolerance windows are listed
OK Measurement OK with the corresponding set points. The values outside the
NOK Measurement NOK permitted tolerance ranges are shown inverted. Like that
XNU x-zero the reasons for NOK evaluations can quickly be located.
YNU y-zero
YTS y-Trigger Start In the status line besides the evaluation OK and NOK dif-
XTE x-Trigger End ferent additional information is displayed corresponding to
YTE y-Trigger End the parameterisation of the respective program.
SA emergency shutdown

Page 130 002-518-3e-01.14


Evaluation of the Measured Values

Key Abbreviation Menu function

Diagr. Measuring curve

Serv. Service and diagnosis

Servo Servo controller

Setp Input of set points

Calib Calibration and system settings

Docu Documentation and protocolling

With the ENTER key you can switch between


the forward and backward display (only possible if both
directions of movement have been selected in the pa-
rameter menu, see chapter 7.1.2).
Only the windows are shown which were activated for
the respective direction of movement (see example be-
low, window 5 for backward).

Value for direction of


movement backward

If a window for both directions (forward & backward)


was activated, the window is shown in both tables).

002-518-3e-01.14 Seite 131


Contents

If a window was deactivated (not deleted) the following


display appears (as example window 2).

6.3.2 Menu Diagram


78B

Presentation of actual values (measured values) of the pre-


vious measurement as characteristic.

Diagram end (Y)


Y-Axis (X=0)
Window 1 type 1
Meas. program forward
number Window 2 type 1
forward
Status
Window 3 type 0
Direction of movement of displacement left
the Min-Max display Window 4 type 0
(here forward) force at the top

Min-Max display
(Extreme values)
X-axis (Y=0)

Diagram Start (Y)

Diagram Start (X) Diagram End (X)

With the ENTER key you can switch in the Min-


Max display between forward and backward (only possi-
ble if both directions of movement have been selected in
the parameter menu, see 7.1.2).

Page 132 002-518-3e-01.14


Evaluation of the Measured Values

Key Abbreviation Menu function


Tab Meas. data as table

Curs Cursor menu / diagram-Zoom

Serv Service and diagnosis

Servo Servo controller

Set point Input of setpoint values

Calib Calibration and system settings

Docu Documentation and Protocolling

+ HardCopy Diagram, measured values and set points to LPT

Status
OK Measurement OK
NOK Measurement NOK
XNU x-zero
YNU y-zero
YTS y-Trigger Start
XTE x-Trigger End

Display for gradient or breakpoint recognition

In the diagram, a found gradient point or breakpoint is


marked by a vertical duplicate-line. Its coordinates (x,y) are
shown instead of the absolute y-External left below beside
the diagram.
(If in the same measuring program both a gradient and a
breakpoint window are programmed, the display of the
breakpoint has priority.)

Gradient point Breakpoint

Coordinates Gradient point Coordinates Breakpoint

002-518-3e-01.14 Seite 133


Contents

6.3.3 Diagram Menu in the Cursor and Zoom Mode


79B

change from the diagram menu into the cursor mode

Mode

X-coordinate of the cursor Y-coordinate of the cursor

You can use the ENTER key in compression-trac-


tion measurements to switch between compression and
traction. Traction is characterized as min and compression
as max. The direction of movement is indicated by > for
forward and < for backward.

Key Abbreviation Menu function

Move the cursor to the left

Move the cursor to the right


Cuts the characteristic left from the actual Cursor position. Like that the
presentation is horizontally expanded to the new display range. A more
detailed view is possible. The cut-off measured values, however, remain
internally stored and are not deleted.
Cuts the characteristic at the right-hand side of the actual cursor position.
Like that the presentation is horizontally expanded to the new display range.
A more detailed view is possible. The cut off measured values, however,
remain internally stored and are not deleted.
Res Resets all the zoom settings and presentation of the original characteristic

Zoom Switch to Zoom (window) mode

End Ends this function and returns to the diagram menu.

Page 134 002-518-3e-01.14


Evaluation of the Measured Values

change from the cursor menu to the zoom mode


Mode

X/Y-coordinate of the selected corner point

Key Abbreviation Menu function


Change the corner point of the zoom window (from the bottom left to the
CP
top right and vice-versa)
Move the Corner point to the left

Move the Corner point to the right

Move the Corner point to the right

Move the Corner point to the bottom

Res Resets all zoom settings and presentation of the original characteristic In

End Ends this function and returns to the cursor mode.

Accept the selected zoom range with the


ENTER key.

002-518-3e-01.14 Seite 135


Contents

7. Programming and Parameter Entry

The programming and parameter entry of the device


can be divided in the following sections:

 Input of data for the measurement (measuring pro-


gram or just program)

The measuring program here consists of the set


points (setpoint record) for the tolerance windows
and the assigned measuring parameters, just called
parameters. Additional the parameters for moving
(position sets) of the servo controller are included
here.

 Input of system data

With the system settings the basic settings of the


device such as operating mode, evaluation method,
interfaces, etc. are performed.

 Input of calibration data and calibration

Scaling and adaptation of sensor sizes to the respec-


tive measuring and display range

 Input of parameters for protocol, statistic and docu-


mentation

Specification of protocol functions, storage and sta-


tistic initialization.

Page 136 002-518-3e-01.14


Programming and Parameter Entry

7.1 Measuring Program


31B

Maximally 32 programs with numbers from 0 … 31 are


possible.

Before the measurement at least one tolerance window


must be entered in the selected program and activated.

The input can be effected numerically or graphically. For


the graphic editing a measuring curve must be available.

7.1.1 Menu Input of Set Points


80B

Up to 8 tolerance windows per program can be entered.

The tolerance windows 1 … 4 can additionally be evaluat-


ed and monitored "live", i.e. during the measurement, if
parameterised as type 1 (see 6.2.4 ). An offline-evaluation
is performed for all windows.

The tolerance windows do not have to be parameterised


continuously. Windows, which are not parameterised or
activated, are ignored during the evaluation. Overlapping
of any windows is permitted.

Rectangular-force-displacement windows (type 1 … 15)


are always defined with the 4 coordinates xmin, Xmax, Fmin
and Fmax. For force- displacement and speed windows (type
0, 17 … 18) the coordinates which are not used must be
set
on 0.

For trapezoidal windows 6 coordinates are required. The


input is effected in the menu Window definition. Further-
more, the settings for the valid direction of movement and
the reference absolute or dynamic are performed in this
menu.

002-518-3e-01.14 Seite 137


Contents

Table display input of set points

Program
number

Tolerance windows 1 … 4
with Live-function Pictogram of
the window
type in the
Tolerance windows 5 … 8 line of the
without Live-function cursor

Column window number Column window type/


Selection of window definition

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field ahead

Prg+ Selection of the next higher program

Pgr- Selection of the next lower program

Edit Editing of the selected field.

Para. Submenu program specific parameter input

End Ends setpoint value input

The sub menu Window definition is accessed when the


cursor is moved on the column window type and the
processing is started with

(please refer also to the next page).

Page 138 002-518-3e-01.14


Programming and Parameter Entry

Submenu window definition

Input fields window type

Input fields window reference

Input fields direction of movement

Input fields of the coordinates

Description
Input of the type of tolerance window (overview 6.2.1), as an assistance, the respective type
Window type
is immediately displayed at the bottom as pictogram.
Defines the window reference in X-direction:
Absolute: Coordinates are absolute
Dynamically forw./backw.: Window is adjusted relative to the right reversing point (end
x-coordinate
point) of the curve.
Dynamically backw./forw.: Window is adjusted relative to the left reversing point (end point)
of the curve.
Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field ahead

Win+ Selection of the next window

Win- Selection of the previous window

Edit Editing of the selected field

Del. The complete window is deleted

End Ends this function and returns to the menu input of set points

002-518-3e-01.14 Seite 139


Contents

Submenu Window Definition Window Type 0 (16) Displacement

Window type 0

Input direction

Input
coordinates
Smin and Smax Selection in mode V3
not available and not
displayed

The menu input for windows type 16 is identical (only ac-


count boundary line).

Description

Window type 0 displacement window

x-coordinate Absolute: Coordinates are absolute fixed fore window type 0 (editing not possible).

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Absolute reference of window (fix absolute coordinates).

Activates Mastercheck will fit win. todispl.max.

Function enables placing of window at maximum of trace displacement using teach-in (refer to
chapter 7.2.2.) by measurement mastercheck.
Measurement mastercheck is started by depending input.
Mastercheck will After the measurement mastercheck the window is placed at maximum of trace displacement
fit win. to symmetrical. The window size is given by the initial difference of Smin and Smax.
displ.max.
This function is in modus V3 not available.

Applications using master sample function and its check starting measuring by input master
control, the window must be placed absolute. In this case Mastercheck will fit win. to
displ.max. must be disabled (not activated)
It is recommended to generate a own program for this function with a window having absolute
borders

Page 140 002-518-3e-01.14


Programming and Parameter Entry

Submenu Window Definition Window Type 0 (17) Force

Window type 0

Input direction

Input
coordinates
Fmin und Fmax Selection in mode V3
not available and not
displayed

The menu input for windows type 17 is identical (only ac-


count boundary line).
Description

Window type 0 force window

x-coordinate Absolute: Coordinates are absolute fixed fore window type 0 (editing not possible).

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Absolute reference of window (fix absolute coordinates).

Activates Mastercheck will fit win. to force max point

Function enables placing of window at maximum of trace force using teach-in (refer 7.2.2.) by
measurement mastercheck.
Measurement mastercheck is started by depending input.
Mastercheck will
After the measurement mastercheck the window is placed at maximum of trace force sym-
fit win. to force
metrical. The window size is given by the initial difference of Fmin and Fmax.
max point
This function is in modus V3 not available.

Applications using master sample function and its check starting measuring by input master
control, the window must be placed absolute. In this case Mastercheck will fit win. to force
max point must be disabled (not activated)
It is recommended to generate a own program for this function with a window having abso-
lute borders

002-518-3e-01.14 Seite 141


Contents

Submenu Window Definition Window Type 4 Snap Window

Input window type

Input coordinates
reference

Input of direction
Input coordinates

Online Evaluation

Input of coordinates

Description

Input of the type of tolerance window (overview 6.2.1), as an assistance, the respective type is
Window type
immediately displayed at the bottom as pictogram.

Defines the window reference in X-direction:


Absolute: Coordinates are absolute
Dynamically forw./backw.: Window is adjusted relative to the right reversing point (end point)
x-coordinate
of the curve.
Dynamically backw./forw.: Window is adjusted relative to the left reversing point (end point)
of the curve.

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Offline Evaluation of window.


Online Evalua-
tion Online Evaluation of window.
Only when using absolute coordinates possible.
(refer to 6.2.7 window type 4)

Page 142 002-518-3e-01.14


Programming and Parameter Entry

Submenu Window Definition for Gradient Windows

gradmax x

gradmin

xmin xmax

Description

Window type 23 gradient windows

x-coordinate Absolute: Coordinates are always absolute in window type 23

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

xmin
The x-section, in which the gradient is calculated and controlled
xmax

gradmin Specifies a gradient interval for the curve. For definition refer to 7.2.24. window type 23 gradi-
gradmax ent window.

Length of the x-interval, above which the gradient (i.e. the difference quotient ∆y/∆x) is de-
fined (see chapter 7.2.24).
∆x
The parameter must be selected carefully: A higher ∆x causes stronger smoothening of the
curve, smaller y-peaks can like that not enter the gradient calculation

Window can be configured for to different evaluation modes:


IO/NIO 1. As window for OK/NOK evaluation
2. As window for online-Triggers (YTE) releasing
YTE For details refer to 7.2.24. window type 23 gradient window. Activating both modes same time
makes no sense.

002-518-3e-01.14 Seite 143


Contents

Submenu Window Definition for Breakpoint Windows

gradmax ymax

Units Trigger offset

gradmin Trigger offset

ymin

xmin x xmax
Description

Window type 24 Gradient windows

x-coordinate Absolute: coordinates are always absolute in window type 24

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude windows
from the evaluation, without deleting them.

xmin
The x-section in which the gradient is calculated and controlled.
xmax

Specifies the interval, in which the alteration of curve gradient must lie, so that a breakpoint can be recog-
nized as such.
∆gradmin The alteration of curve gradient is determined between two neighbouring curve sections of the length
delta_x. As soon as this gradient alteration – within the section [xmin, xmax] – is higher than or equal to
∆gradmax ∆gradmin for the first time and below or equal to ∆gradmax this curve point P is recognized as breakpoint.

∆gradmax ≥ (∆y2 – ∆y1) / ∆x ≥ ∆gradmin

Length of the x-interval over which the gradients (i.e. the difference quotients ∆y2/∆x and ∆y1/∆x) are
determined, and from there the alteration of gradient.
∆x
The parameter should be selected carefully. A higher ∆x causes stronger smoothing of the curve, smaller y-
peaks can like that not enter the gradient calculation.

Page 144 002-518-3e-01.14


Programming and Parameter Entry

Description

If 0.00 is default setting for the trigger offset , a pure break control is carried out thought the
breakpoint:
As soon as a breakpoint (in this case with falling gradient) has been diagnosed, regardless if it is
inside or outside the window, the work piece is considered destroyed and the signal output YTE
Trigger offset set in real time. The complete measurement is evaluated NOK.

If the trigger offset is programmed unequal 0.00, a real breakpoint control is carried out.
Contrary to the pure break control a breakpoint must be found and it must lie in the interval
[ymin, ymax] so that the measurement can be evaluated OK.

In the real breakpoint control an online trigger output is set, after a breakpoint has been found,
and after a defined way section (or a rotation angle or after a time interval at time measure-
ment) has been travelled from x-position of the breakpoint or after modification of the y-
quantity (force, torque,..) by a certain amount regarding the y-position of the breakpoint.
Units
The dimension unit of the trigger offset defines whether an x- or a y triggering should take
Trigger offset
place. If the x-dimension unit is selected the trigger offset is an x-section, after it has been
traversed from breakpoint the signal output XTE is set. If however, the
y-dimension unit is set, after a modification of the y-value the signal output YTE is set by the
amount "trigger offset" regarding the breakpoint y-value.

ymin
The y-borders of the breakpoint window
ymax

002-518-3e-01.14 Seite 145


Contents

Submenu Window Definition for 27 Localized Displacement Monitoring

Window type 27
Input direction

Fpos Stol
Spos

SBmin SBmax

Description

Window type 27 localized displacement monitoring window

x-coordinate Absolute: Coordinates are absolute fixed fore window type 27 (editing not possible).

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Fpos Force at tolerance range Spos ± Stol which has to be exceeded or fallen below.

Spos Position (middle) of tolerance range.

Stol Tolerance range

SBmin
Value area min. und max. fixes search range of Spos during measurement mastercheck.
SBmax

Absolute reference of window (fix absolute coordinates).

Activates Mastercheck overwrites displ. setpoint


Mastercheck
Function enables placing of window at intersection point trace and force value Fpos using teach-
overwrites
in (refer to 7.2.28.) by measurement mastercheck. Search range is defined by SBmin and SBmax.
displ. setpoint
Measurement mastercheck is started by depending input.
After the measurement mastercheck the window is placed at the found displacement position
Spos symmetrical. The window size is kept by Stol.

Page 146 002-518-3e-01.14


Programming and Parameter Entry

Submenu Window Definition for 28 Localized Force Monitoring

Window type 28
Input direction

Fpos Ftol
Spos

Description

Window type 28 localized force monitoring window

x-coordinate Absolute: Coordinates are absolute fixed fore window type 28 (editing not possible).

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Spos Displacement at tolerance range Fpos ± Ftol which has to be exceeded or fallen below.

Fpos Position (middle) of tolerance range.

Ftol Tolerance range

Absolute reference of window (fix absolute coordinates).

Activates Mastercheck overwrites displ. setpoint


Mastercheck
Function enables placing of window at intersection point trace and displacement value Spos
overwrites
using teach-in (refer to 7.2.28.) by measurement mastercheck.
displ. setpoint
Measurement mastercheck is started by depending input.
After the measurement mastercheck the window is placed at the found displacement position
Fpos symmetrical. The window size is kept by Ftol.

002-518-3e-01.14 Seite 147


Contents

Submenu Window Definition for 29 Restricted Area

Window type 29

Input coordinates reference

Input of direction

Input fields of the coordinates

Description
Input of the type of tolerance window (overview 6.2.1), as an assistance, the respective type is
Window type
immediately displayed at the bottom as pictogram.
Defines the window reference in X-direction:
Absolute: Coordinates are absolute
Dynamically forw./backw.: Window is adjusted relative to the right reversing point (end point)
x-coordinate
of the curve.
Dynamically backw./forw.: Window is adjusted relative to the left reversing point (end point)
of the curve.
Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Page 148 002-518-3e-01.14


Programming and Parameter Entry

Submenu Window Definition for Wwindow Ttype 32 Energy Window

Selection of unit

Description

Input of the type of tolerance window (overview 6.2.1), as an assistance, the respective type is
Window type
immediately displayed at the bottom as pictogram.

Defines the window reference in X-direction:


Absolute: Coordinates are absolute
Dynamically forw./backw.: Window is adjusted relative to the right reversing point (end point)
x-coordinate
of the curve.
Dynamically backw./forw.: Window is adjusted relative to the left reversing point (end point)
of the curve.

Defines the direction of movement in which the window should be evaluated:

Forward: Window is only evaluated in forward movement

Backward: Window is only evaluated in backward movement


Direction
Forw.&Backw.: Window is evaluated in both directions of movement

deactivated: The window is switched off for the evaluation. Like that it is possible to exclude
windows from the evaluation, without deleting them.

Energy will be measured always – independent of x- or y-unit setting at calibration menu –


with Joule (J) or Kilojoules (kJ) as unit. At menu setpoint input these units can be selected.
Unit
Therefore it is possible to adapt the display of energy (better 21 J as 0,021 kJ, better 123,45 kJ
as 12 345 J):

1 J = 1 N·m = 1 Ws

002-518-3e-01.14 Seite 149


Contents

7.1.2 Parameter Menu


81B

From the menu input of set point values access the Param-
eter Menu with F6 to enter the program specific parame-
ters.

Force threshold

Only for SSI- or


incremental
displacement
sensors available Displacement
threshold

Page 150 002-518-3e-01.14


Programming and Parameter Entry

Parameter Description

YTS It is possible to enter a force


F-Trigger Start threshold, which is used as start F
value for a force-triggering. After
the force has exceeded the value
F-Trig.Start, the recording is start-
ed (first the signal Meas_Start must
apply).
F-Trig.Start
The displacement values of the
windows then do not refer to the Displacement zero point of the
evaluation S
calibrated zero point any more. Output
The displacement zero point corre- 1
sponds with the point, which the
displacement measuring system
takes when the force threshold is exceeded.

The trigger can be activated dependent on the direction of movement:


Deactivated: No activation of the trigger when the force threshold is exceeded.
y increasing: Trigger only if the force value has been exceeded (from below to top),
independent of the x direction of movement
y decreasing: Trigger only if the force value has been declined (from top to below),
independent of the x direction of movement

In all the active cases the force threshold must be exceeded.

Differing from the known settings at the device DMF-P


V3 the respective trigger must be explicitly activated or
deactivated. Here the value 0 applies as threshold and
does not deactivate the trigger.

002-518-3e-01.14 Seite 151


Contents

Parameter Description
XTN
It is possible to enter a
X-Trigger Zero
displacement threshold,
which is used as start value
for a displacement-
triggering. After the dis-
placement has exceeded
the value X-Trig.Zero, the Focre zero for
evaluation
recording is started (first
the signal Meas_Start must
apply). X-Trig.Zero
The force values of the
windows then do not refer
to the calibrated zero point
any more. The force zero
point corresponds with the point, which the force measuring system takes when
the displacement threshold is exceeded.
The trigger can be activated dependent on the direction of movement:
Deactivated: No activation of the trigger when the force threshold is exceeded.
Forward: Trigger only in forward movement from left to right
Backward: Trigger only in backward movement from right to left.

In all the active cases the displacement threshold must be exceeded.

For XTN is no output available.

Page 152 002-518-3e-01.14


Programming and Parameter Entry

Parameter Description
YTE
A force threshold can be
F-Trigger End F "kN"
entered which is used as
end value for a force trig- Y-TE
ger. After the force has
exceeded the value F-Trig.
end the output signal Y-TE
is set. The measurement
must be ended via Meas- S "mm"
urement_Stop or dis- Output 1
placement reverse (20 %). Y-TE 0

The trigger can be activated dependent on the direction of movement:


y increasing: Trigger only if the force value has been exceeded (from below to
top), independent of the x direction of movement
y decreasing: Trigger only if the force value has been declined (from top to be-
low), independent of the x direction of movement

In all the active cases the force threshold must be exceeded.


XTE
A displacement threshold can
S-Trigger End
be entered, which is used as F "kN"
end value for a displacement
triggering. After the displace-
ment has exceeded the value
s-Trig.End, the output signal X-TE
X-TE is set. The measurement
must be ended via measure- Output 1 S "mm"
ment stop or displacement X-TE 0
reverse (20 %).

The trigger can be activated depending on the direction of movement:


Deactivated: No activation of the trigger when the displacement threshold is ex-
ceeded
Forward: Trigger only in forward movement from left to right
Backward: Trigger only in backward movement from right to left.
In all the active cases the force threshold must be exceeded.

002-518-3e-01.14 Seite 153


Contents

Parameter Description
SA
If the force exceeds the value SA-force at a displacement position, which is not
SA-force-
higher than SA-displacement, an emergency shutdown takes place, Y-TE is set,
displacement
the measurement is evaluated NOK.
Emergency shut-
down Emergency shutdown No emergency shutdown
(bipolar)

The triggering can be activated depending on the direction of movement:


Deactivated: The triggering is not activated when the force value has been ex-
ceeded
Forward unril: Trigger forward to x-position
Backward until: Trigger backward to x-position
Forw.&Backw.: Trigger independent of the direction of movement
Order number
Here for each program a 10-digit alphanumeric order number can be saved for a
later identification in the protocol printout. This number can also be pre-defined
through the Fieldbus.
Damping
A value between 0 and 5 can be entered. The damping smoothes the measuring
signal. The higher the damping factor, the higher the smoothing. At 0 the damp-
ing is deactivated.
Direction of
The measuring direction defines for which direction of movement the recording
measurement
and evaluation of the curve is performed.
Forward: Forward movement from lower to higher X values
Backward: Backward movement from higher to lower X values
Forw.&Backw.: For both directions of movement
Direction-dependent windows, which are not defined for the particular direction,
are not included in the evaluation. Windows, which are defined for Forw.&backw.
are in restricted direction only evaluated for the selected direction.
If the direction of measurement is set forward or backward, an intern reverse
identification is performed. The values for the other direction are cancelled then.
Therefore a reverse identification for the displacement of 1 % of the measuring
range is automatically started.
If Forw.&Backw. has been set as direction of measurement the sensitivity can be
adjusted in the submenu Reverse identification (operate ).

Direction of force
The direction of force specifies whether the force-maximum (compression),
-minimum (traction) or both values (traction&compression) are recorded and
evaluated during the measurement. If the direction of force is traction
&compression, a band can be created depending on the measuring signal (e.g.
signal noise). The width of this band represents for each X-value the correspond-
ing Min-Y and Max-Y value. At traction&compression please note that in the
window evaluation the spaces from both the min- and max-values to the respec-
tive window edges must be checked.

Page 154 002-518-3e-01.14


Programming and Parameter Entry

Parameter Description
X-Diagr.: Min
Defines the start point in X-direction of the diagram for the selected program

Can also be set for all programs together in the menu Calibration X.

X-Diagr.: Max
Defines the end point in X direction of the diagram for the selected program.

Can also be set for all programs together in the menu Calibration X.

Y-Diagr.: Min
Defines the start point in Y direction of the diagram for the selected program.

Can also be set for all programs together in the menu Calibration Y.

Y-Diagr.: Max
Defines the end point in Y-direction of the diagram for the selected program

Can also be set for all programs together in the menu Calibration Y.

X-Offset Program depending displacement offset


If in a certain program an X-Offset is entered (e.g. 25 mm), the offset will be
added to the displacement value.
See also menu Calibration X

Y-Offset Program depending force-offset


By specifying Y-Offset e.g. different tool weights can be compensated in the re-
spective program.

The following items are only available in SSI or incremental


displacement sensors:

Parameter Description
X-measuring
range Min Defines the start point in X direction of the diagram for the selected program.

Can also be set for all programs together in the menu Calibration X.

X-Measuring
range Max Defines the end point in X direction of the diagram for the selected program

Can also be set for all programs together in the menu Calibration X.

Y-Measuring Using NC joining modules with a piezoelectric load cell or using an ICAM one of
range two measure ranges can be chosen for each program

002-518-3e-01.14 Seite 155


Contents

With F6 it is possible to invoke the submenu turnback de-


tection, when the measurement direction is set to for-
ward&backward and the cursor is located at input meas-
urement direction

Submenu Turnback Detection

activated

deactivated

Parameter Description
Speed
The sensitivity can be set in 9 levels. (1=insensitive 5=normal 9=extremely sensi-
tive)

Displacement
As soon as the configured displacement is travelled in the opposite direction the
direction is switched intern.

External
Direction of movement Backwardmeasurement is defined by external signal
Fieldbus: Control 2. Byte Bit 7
Digital I/O: PIN 48 PLC Interface
Refer interface and communication manual.

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field forward

Edit Processing of the selected field

End Ends this function and returns to the menu Input of setpoint values

Page 156 002-518-3e-01.14


Programming and Parameter Entry

7.1.2.1 Menu Joining Parameter Standard Joining Operation "Short"

The basic selection of joining parameter and transmitting


mode (to servo controller) is done at menu System setup 4.
With F6 the submenu Joining Parameter can be invoked
out of menu Parameter.

The function position sets are defined.


Description of detail please see standard joining operation
"short".

Speed of movement

Parameter Description
The maximum press force can be limited. Notice there is no linear relation between
Force limitation
the nominal press force of the system and the force limitation. The requested max.
force depends on mass and speed and must be determined by successive approxi-
mation. Range of adjust 50 … 100 %.
The configured set point value is valid for all position sets, including acceleration
and brake. If the force limitation is configured too low, it is possible that the energy
is not sufficient to reach the requested nominal speed, or the target position may
be over traveled, because there is insufficient braking energy. For this reason when
the device is put into operation accurate tests must be carried out.
Should force limitation be performed directly from the PLC to the servo controller,
the parameter transmission may be turned off. After appropriate reprogramming
the servo controller can obtain its limit value either as analog signal or directly as
fieldbus parameter. Like that, the PLC can decide whether the active position set
requires more or less power.

Force limita- Data transmitting


tion
≥50 … 100 % Active, transmission with position sets
=0 % No transmission, specification through PLC
Transmitting all data of position as complete data frame (setting all auto. or all ext,
refer System setup 4) only the smallest set value will be sent.

Reduction of the force limitation could take effect on


the characteristics of braking. This could take influence
on the safety functions SS1ES, SS2 … .

002-518-3e-01.14 Seite 157


Contents

This parameter takes effect on the brake ramp. This


refers also to emergency stop (also in case of safety
functions).

Parameter Description

Setlettime Time until the evaluation, during which press force is present or force control
is active after drive standstill

Tool Correction (Parameter read only!) – Offset of target position

Expansion None, force regulation, compensation of process compression.


See chapter: Force regulation and compensation of process compression.
Home Position
Target position, position set 0
Home position of the joining system, depending on mechanic

Idle Stroke
Target position, position set 1 automatically stepping record set 2
Idle stroke, typical fast speed of movement.

Joining
Target position, position set 2 Joining stroke, low speed of movement,
(≤10 mm/s) at block joining

Stroke Backward
Speed of movement to home position

Page 158 002-518-3e-01.14


Programming and Parameter Entry

7.1.2.2 Menu Joining Parameter Extended Joining Operation "Long"

The basic selection of joining parameter and transmitting


mode (to servo controller) is done at menu System setup 4.
With F6 the submenu Joining Parameter can be invoked
out of menu Parameter.
The functions of the position sets are predefined.
For details refer to chapter standard joining sequence.
Attribution of position sets is arbitrary, although setting of
records. The input is limited to the number set at System
setup 4.

Speed of movement
Stepping of record

Paging is done by cursor automatically.

002-518-3e-01.14 Seite 159


Contents

Parameter Description

Force Limitation The maximum press force can be limited. Notice there is no linear relation be-
tween the nominal press force of the system and the force limitation. The re-
quested max. force depends on mass and speed and must be determined by
successive approximation. Range of adjust 50 -100%.

The configured set point value is valid for all position sets, including acceleration
and brake. If the force limitation is configured too low, it is possible that the
energy is not sufficient to reach the requested nominal speed, or the target
position may be over travelled, because there is insufficient braking energy. For
this reason when the device is put into operation accurate tests must be carried
out.

Should force limitation be performed directly from the PLC to the servo control-
ler, the parameter transmission may be turned off. After appropriate repro-
gramming the servo controller can obtain its limit value either as analog signal
or directly as fieldbus parameter. Like that, the PLC can decide whether the
active position set requires more or less power.

Force limitation Data transmitting


≥50 … 100 % Active, transmission with position sets
=0 % No transmission, specification through PLC

Transmitting all data of position as complete data frame (setting all auto. or all
ext, refer to System setup 4) only the smallest set value will be sent.

Setlettime Time until the evaluation, during which press force is present or force control is
active after drive standstill

Tool Correction (Parameter read only!) – Offset of target position

Position Set xx Position set of target position, speed of movement and stepping of record

Reduction of the force limitation could take effect on


the characteristics of braking. This could take influence
on the safety functions SS1ES, SS2 … .

Page 160 002-518-3e-01.14


Programming and Parameter Entry

Record Stepping

SC Positioning absolute/relative Record stepping Speed profile

A- Absolute set point record No stepping

A1 Absolute position set Stepping mode 1

A2 Absolute position set Stepping mode 2

AH Absolute position set At target position with halt

R- Rel. pos.set with rest path storage No stepping

R1 Rel. pos.set with rest path storage Stepping mode 1

R2 Rel. pos.set with rest path storage Stepping mode 2

RH Rel. pos. set with rest path storage At target position with halt

R0 Rel. pos. set without rest path storage No stepping

Stepping condition Function Example


Positioning at absolute positioning, refer to
A Absolute positioning
machine zero-point.
Relative positioning, target position
R Negative values for back strokes
depends on the start position

– Move to position and stop Joining, back stroke

H Move to position, stop and starts Changing moving direction


next position set immediately

1 Change speed at target position to Removing from work piece


speed of next position set

Change speed to speed of next


2 Idle stroke (rapid stroke forward before
position set before reaching target
joining)
position
Move to position and stop and do Relative move after reaching block
0
not try to move to previous position position

The joining position set must stop with "–" or "0", be-
cause the back stroke must be started by a separate start
signal of the PLC. Otherwise neither settling time or
moving depending on the evaluating of the measurement
are not possible. Changing direction of movement, the
actual position set must be closed by AH.

002-518-3e-01.14 Seite 161


Contents

7.1.2.3 Global Joining Parameter Position Sets 60 … 63


If transmit mode is set to all auto. or all ext. at menu Sys-
tem setup 4, all active position sets will be stored in the
servo controller position sets 0 … 59 continuously. In this
case the position sets 60 … 63 are available additionally.
With F6 the submenu global joining parameter can be in-
voked out of menu Joining Parameter.
For global positions e.g. general home positions, these po-
sition sets 60 … 63 can be used. Out of this, the number
of position sets while transmitting all can be reduced.

7.1.2.4 Menu Joining-Parameter Force Controlling


Servo controller IndraDrive with MLD allows to activate
force control during joining operation. Therefore at menu
System setup 4 item Servocontroller must be set to In-
draDrive with MLD. This function is available in both join-
ing menus, short or long, but not using transmitting all. For
each program is only one extension possible. Combinations
must be realized in different programs.

Page 162 002-518-3e-01.14


Programming and Parameter Entry

Extension parameter Description


None: Stopping at reaching of target position / force limitation or trigger level,
e.g. block joining using trigger YTE.
Extension Forcereg.: For holding force during defined time, select force control Forcereg.
Deform. comp.: For precise force independent positioning, select Deform.
comp.

Time until the evaluation, during which press force is present or force control is
Setlettime
active after drive standstill

Set of joining parameters, in which force control is active. Force control is start-
ed with set speed of movement. Using joining parameter short it is position
Joining parameters
(joining) set 2. If force setpoint is during movement not reached, so final posi-
tion is set target position of position set.

F(orce) setpoint Force setpoint for force control

Regulation speed Max. speed of movement during force control.


Force set point
Threshold as a percentage of the force setpoint. From this point, the system
threshold (force
switches to parameterised regular speed.
threshold)
System compression The entered process compression for the system is taken into consideration in
(system compressi- the force-distance evaluation in the DMF-P A300 NCF but is not actively com-
on) pensated using the servo controller.

Attention: For safety YTE should always be set above


force setpoint or equal nominal joining force of the unit.

7.1.2.5 Menu Joining Parameter Deformation Compensation


Servo controller IndraDrive with MLD allows to activate
deformation compensation during joining operation.
Therefore at menu System setup 4 item Servocontroller
must be set to IndraDrive with MLD. This function is avail-
able in both joining menus, short or long, but not using
transmitting all. For each program is only one extension
possible. Combinations must be realized in different pro-
grams.

002-518-3e-01.14 Seite 163


Contents

Zusätzliche Parameter Beschreibung

Extension None Switch-off takes place when the target position/force limit or the trig-
ger settings are reached, e.g. joining on block via the YTE trigger to be pa-
rameterised.

Force regulation: If the force is to be held for a defined period of time, the
force regulation expansion must be selected.

Compensation for process compression: The compensation for process com-


pression expansion must be selected to achieve highly precise, force-
independent positioning.
Setting time Time until evaluation during which joining force is pending after the drive has
become stationary.
Joining parameter The joining parameter in which the compression compensation is active. This
is in short joining menu position set 2.
System compression the compression of the machine frame will be active compensated according
(system compression) to the preset value.

Attention: For safety YTE should always be set above


force setpoint or equal nominal joining force of the unit.

Determine deformation of system (mechanic):


Move using jog mode on block (10 % of nominal force of
joining unit Fn10% in KN )
=> Read position x1 [mm]
Move using jog mode on block ( nominal force of joining
unit Fn in KN )
=> Read position x2 [mm]

x 2  x1 [ mm]
Deform. cl. =
Fn  Fn10% [ KN ]

Notice: In case jog speed has to be reduced directly on


the servo controller or using V-preselect.

Page 164 002-518-3e-01.14


Programming and Parameter Entry

7.1.3 Joining Parameter DMF-P A310 Universal Type 4740A…

7.1.3.1 Joining parameters menu, standard joining process “short”


Selecting the basic setting for the joining parameters is
done in the System settings 4 menu.

Pressing F6 takes the user from the Parameters menu to


the Joining parameters menu for entering the program-
specific parameters.
Die Funktionen der Positioniersätze sind festgelegt. The
functions of the positioning sets are specified.
Detailbeschreibung siehe Kapitel: for a detailed description,
See chapter: Standard joining process “short”.

Movement
speed

Parameter Description
Setting duration Time until evaluation during which joining force is pending after the drive
has become stationary, or the duration of force regulation after the drive has
become stationary

Extension None, force regulation, compensation for process compression


See chapter: Force regulation or compensation for process compression
Basic position Target position, positioning set 0
Basic position of the joining system, machine-dependent

Idle stroke Target position position set 1, automatic set Sequencing to set 2
Idle stroke up to workpiece, usually at high speed

Joining Target position positioning set 2 force stroke, with low speed
(≤10 mm/s) during joining on block

Return stroke Travel speed to the basic position

002-518-3e-01.14 Seite 165


Contents

7.1.3.2 Joining Parameters Menu, Expanded Joining Process “long”


Selecting the basic setting for the joining parameters is
done in the System settings 4 menu.

Pressing F6 takes the user from the Parameters menu to


the Joining parameters menu for entering the program-
specific parameters.
The functions of the positioning sets are specified.
For a detailed description, See chapter: Standard joining
process “long”.
The assignment of the individual positioning sets is ran-
dom, as is the respective set Sequencing . The number of
positioning sets is set and liited to 16.

Position set sequencing

Movement speed

“Paging forward” is performed automatically with the help


of the cursor keys.

Page 166 002-518-3e-01.14


Programming and Parameter Entry

Parameter Description

Setting duration Time until evaluation during which joining force is pending after the drive has
become stationary, or the duration of force regulation after the drive has be-
come stationary
Positioning set xx Positioning set with target position, speed and set Sequencing

Set Sequencing (SWS)

SWS Positioning absolute/relative Set Sequencing Speed curve

A- Absolute positioning set No position set sequencing

A1 Absolute positioning set Sequencing mode 1

A2 Absolute positioning set Sequencing mode 2

AH Absolute positioning set For intermediate stop e.g.


with reverse direction. In
case of changing direction
drive must come to com-
plete stop before moving in
opposite direction
R- Rel. pos. set with remaining dis- No position set sequencing
tance storage
R1 Rel. pos. set with remaining dis- Sequencing mode 1
tance memory
R2 Rel. pos. set with remaining dis- Sequencing mode 2
tance memory
RH Rel. pos. set with remaining dis- For intermediate stop e.g.
tance memory with reverse direction. In
case of changing direction
drive must come to com-
plete stop before moving in
opposite direction
R0 Rel. pos. set without remaining No set Sequencing
distance memory

SWS Function Example application in positioning set


A Absolute positioning Positioning at absolute position in relation
to the machine zero point
R Relative positioning, target position dependent on Positioning in relation to the current
start position position, i.e. negative positioning specifi-
cation are necessary for
return strokes.
– Move to target position and stop Join, return stroke
H Move to target position, stop and immediately Change of direction of movement
autommatically start the next position set

002-518-3e-01.14 Seite 167


Contents

1 Speed adaptation to the speed of the next position Multistep return trip from workpiece
set from the target position
2 Speed adaptation to the speed of the next position Idle stroke
set before the target position
0 Move to target position without remaining dis- Relative travel set after block position
tance memory

The joining sequence must always end with the code


“-“ or “0” because the return trip to the basic position
must be started with a new start signal by the PLC.
Otherwise no setting time or evaluation-dependent
return trip can be used. The current position set must
end with AH (absolute positioning set) for direction
changes in the following position set.

Page 168 002-518-3e-01.14


Programming and Parameter Entry

7.1.3.3 Joining Parameters Menu, Force Regulation


Force regulation during the joining procedure can be acti-
vated when making the IndraDrive Uni servo controller
settings. This functionality is available in both the short and
the long joining menus. Only one expansion is possible per
program. Combinations must be implemented using vari-
ous programs.

Additional parameters Description


Extension None Switch-off takes place when the target position/force limit or the trig-
ger settings are reached, e.g. joining on block via the YTE trigger to be pa-
rameterised.
Force regulation: If the force is to be held for a defined period of time, the
force regulation expansion must be selected.
Compensation for process compression: The compensation for process
compression expansion must be selected to achieve highly precise, force-
independent positioning.

Time until evaluation during which joining force is pending after the drive
Setting time
has become stationary, or the duration of force regulation after the drive has
become stationary
Joining parameters Joining parameters in which the force regulation is to take place. The force
regulation is initiated with the entered travel speed. For the short joining
menu, this is joining parameter 2. If the force set point is not reached by the
target position, positioning on the target is performed.
Force set point Force set point on which regulation is to be based.
(F set point)
Regulation speed The maximum travel speed during force regulation.
Force set point thresh- Threshold as a percentage of the force set point. Switching to the parame-
old terised regulation speed is carried out at this point.
(force threshold)
System compression The entered system compression is taken into account during the distance-
(system compression) force evaluation in the DMF-P A310 Universal, but is not actively compen-
sated with the servo controller.

002-518-3e-01.14 Seite 169


Contents

For reasons of safety, YTE should always be set above


the force set point or at the nominal joining force of the
module.

7.1.3.4 Joining Parameters Menu, Compensation for Process Compression

Force regulation during the joining procedure can be acti-


vated when adjusting the IndraDrive Uni servo controller
settings. This functionality is available in both the short and
the long joining menus. Only one expansion is possible per
program. Combinations must be implemented using vari-
ous programs.

Additional parameters Description

Extension None Switch-off takes place when the target position/force limit or the trig-
ger settings are reached, e.g. joining on block via the YTE trigger to be pa-
rameterised.
Force regulation: If the force is to be maintained for a defined period of time,
the force regulation expansion must be selected.
Compensation for process compression: The compensation for process com-
pression expansion must be selected to achieve highly precise, force-
independent positioning.
Time until evaluation during which joining force is pending after the drive has
Setting time
become stationary.
Joining parameters The joining parameters for which the compensation for compression is active.
For the short joining menu, this is joining parameter 2.
System compression The entered system compression is taken into account during the distance-
(system compression) force evaluation in the DMF-P A310 Universal, but is not actively compen-
sated with the servo controller.

For reasons of safety, YTE should always be set above


the expected force value or at the nominal joining force
of the module.

Page 170 002-518-3e-01.14


Programming and Parameter Entry

Determining the system/equipment compression:


Travel onto the block in jog mode (10 % of the nominal
range of the joining module Fn10% in KN )
→ Read the position x1 [mm]
Travel onto the block in jog mode (nominal range of the
joining module Fn in KN )
→ Read the position x2 [mm]

x2 – x1 [mm]
Stauch. Anl. 
Fn – Fn10% [kN]

The jogging speed must be reduced if necessary either


directly in the servo controller or via the V presetting.

002-518-3e-01.14 Seite 171


Contents

7.1.4 Editing Tolerance Windows Graphically


87B

When the cursor is placed in the first column of the set


point table the graphic mode is accessed with F5.

Mode

Selected window

Display of window
reference (abso-
lute/dynamic) and
window type of the
selected window

Coordinates of the lower left window corner points

Key Abbreviation Menu function


Win> Switches to the next tolerance window
Opens the submenu for movement and type-specification of the selected
Move
window
W-New Adds a new window

W-Del. Deletes the selected window

Edit Opens the submenu to edit the window corner points and the direction setting

Exits the graphic edit mode. A query appears, whether the performed changes
End
should be saved or cancelled

Page 172 002-518-3e-01.14


Programming and Parameter Entry

From the Edit mode select the mode in which the window
can be shifted (Win. move) with F2.

Mode
Selected window

Display of window
reference (abso-
lute/dynamic and
window type of the
selected window

Coordinates of the lower left window corner points

Key Abbreviation Menu function


Moves the selected window to the left

Moves the selected window to the right

Moves the selected window to the top

Moves the selected window to the bottom

WinT Edits the window type

Ab/Dy Selection absolute or dynamic window reference

End Ends this function and returns to the Edit mode

002-518-3e-01.14 Seite 173


Contents

With F5 the mode for editing the Corner points


(Edit.cornerp.) is accessed from the Edit mode.

Mode

Selected window

Display of window
reference (abso-
lute/dynamic) and
window type of the
selected window
Selected window
corner point

Coordinates of the selected window corner point

Key Abbreviation Menu function


Switch to the next corner point. Here always the previous and next corner
CP points are selected at the same time. Like that the two points can be moved
together. When operated again, only the new corner point is selected.
Move corner point(s) to the left

Move corner point(s) to the right

Move corner point(s) to the top

Move corner point(s) to the bottom

Dir. Changes the direction of movement in which the window is active

End Ends this function and returns to the edit mode

Page 174 002-518-3e-01.14


Programming and Parameter Entry

7.1.5 Copying of Measuring Programs


8B

With the function copy program it is possible:


 to copy a single program into another one.
 to copy a single program into all programs .

As program the set points and corresponding parameters


are copied.
The submenu copy program is invoked from the menu Set
point inputs. Therefore the cursor must be placed on the
column Wn (for window) in the menu Set point input. If
the cursor is placed on the column Wn the function Copy
instead of Para is shown.

With F6 the submenu copy program is accessed.

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field forward

Edit Edits the selected field.

Copy Starts the copy process

End Ends this function and returns to the menu Input of set points

To start a copy the user must have logged in with the


programming password. If passwords are not assigned
there are no restrictions!

002-518-3e-01.14 Seite 175


Contents

Copying a Single Program

Select the source Select the target Start the copy Confirm with Yes finished,
or cancel with No return with

Copying a Single Program into all the Programs

For safety reasons a confirmation is here requested twice.

Choose the source Start the copy 1. confirm with 2. Confirm with finished,
and select target Yes or cancel with Yes or cancel with return with
program = 32 No No

If an empty program is copied it is possible to delete all


the programs!

Page 176 002-518-3e-01.14


Programming and Parameter Entry

7.2 System Settings


32B

The system setup primarily refers to the complete device.

7.2.1 Menu System Setup 1


89B

The menu System setup 1 is accessed with F3 from the cal-


ibration menu.

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field forward

C+ Increase the screen contrast

C- Decrease the screen contrast

Edit Edits the selected field

Sys. 2 Switches to the menu System settings 2

End Ends this function and returns to the calibration menu

002-518-3e-01.14 Seite 177


Contents

Setting Description

Date/time Correction/modification of the device-intern real-time clock

Serial/CPU/IO Intern serial- and version numbers cannot be changed by the user.

Blocks the input of calibration and system parameters and all the calibration func-
System password tions, e.g. access only for maintenance
0 deactivates this password function

Blocks the input of set points and parameters and the access to the docu-menu
Programming
and its submenus
password
0 deactivates this password function

Language selection of the user guidance


Language
German – English

Station-No. Free selectable 6-digit number for station or device identification.

Cycle end Ending the measuring cycle


autom – by standstill signal of the servo controller and possible after setting
time or by displacement return (20 % of the travelled path)
ext – by standstill signal of the servo controller and possible after setting time
YTE – by arrive of Y-trigger threshold Y-Trigger end
XTE – by arrive of X-trigger threshold X-Trigger end
or by control signal Measurement stop.

Timeout – the timeout interval (which is time based) begins below the adjustable
speed threshold VG< i.e. before the threshold has been reached, and it is ended
after the measurement cycle time is complete. In order to activate the timeout
function, the limitVG<must be exceeded. After the VG< threshold is no longer
met, (and therefore time monitoring started) the speed is increased again to
above the VG< limit, then time monitoring is interrupted and reset until the next
VG< threshold is not met.
When using joining modules, select ext.

dimension unit Y-axis


Y-axis
N – kN – bar – kg – lbs – klbs – mV/V – N·m – kN·m

Dimension unit X-axis


X-axis
mm – cm – inch – s

Page 178 002-518-3e-01.14


Programming and Parameter Entry

Setting Description

Protocol function of settings. Changing is stored in file:


Logfile.csv at folder: shared (refer Samba Server setting).

Disable: No protocol
Only changed param.: Only settings like set points, parameter, position sets…
All: Additional to changed parameters all changes or action like calibration, delet-
ing, statistics…
Logging param.
change
Protocol file contains additional fiel UserID storing identifier under which changes
were made. UserID (4Byte number) is send by PLC to device and key switch is
enabled. If changes are made using program- or systempassword, the UserID
sent last is used. Avoiding mistakes it is advised after leaving changes and disa-
bling key switch to reset UserID.

This function is available at fieldbusmode Config or UserConfig only.

Example of file: Logfile.csv:

Date[YYYY.MM.DD];Time;User;Parameter;Channel;Program;Window;Position;OldValue;NewValue
2009.05.04;09:35:36;0;log change param.;;;;;Deaktiviert;Alles
2009.05.04;09:36:09;0;Eval. win. direction;1;0;3;;Deaktiviert;Vorwärts
2009.05.04;09:36:09;0;Eval. win. min. X1;1;0;3;;0,000000;9,000000
2009.05.04;09:36:09;0;Eval. win. max. X1;1;0;3;;0,000000;9,000000
2009.05.04;09:36:28;0;Eval. win. min. X2;1;0;3;;0,000000;43,000000
2009.05.04;09:36:28;0;Eval. win. max. X2;1;0;3;;0,000000;43,000000
2009.05.04;09:39:25;0;Eval. win. min. X1;1;0;4;;0,000000;213,795218
2009.05.04;09:39:25;0;Eval. win. min. X2;1;0;4;;0,000000;218,393624
2009.05.04;09:39:25;0;Eval. win. max. X1;1;0;4;;0,000000;213,795218
2009.05.04;09:39:25;0;Eval. win. max. X2;1;0;4;;0,000000;218,393624
2009.05.04;09:39:25;0;Eval. win. min. Y1;1;0;4;;0,000000;95,705521
2009.05.04;09:39:25;0;Eval. win. min. Y2;1;0;4;;0,000000;236,809816
2009.05.04;09:39:25;0;Eval. win. max. Y1;1;0;4;;0,000000;372,392638
2009.05.04;09:39:25;0;Eval. win. max. Y2;1;0;4;;0,000000;463,190184
2009.05.04;09:39:25;0;Eval. win. type;1;0;4;;0;30
2009.05.04;09:39:25;0;Eval. win. direction;1;0;4;;Deaktiviert;Vorwärts
2009.05.04;09:39:25;0;Eval. win. abs./dyn.;1;0;4;;absolut;dynamisch zur/vor
2009.05.04;09:41:48;0;Delete share-folder;;;;;;
2009.05.04;09:44:01;0;log change param.;;;;;Alles;Deaktiviert
2009.05.06;09:28:54;0;log change param.;;;;;Deaktiviert;Alles
2009.05.06;09:29:26;0;Language;;;;;Deutsch;English
2009.05.06;09:36:56;0;Eval. win. min. X1;1;0;1;;81,000000;82,000000
2009.05.06;09:36:56;0;Eval. win. max. X1;1;0;1;;81,000000;82,000000
2009.05.06;09:50:22;0;Language;;;;;English;Deutsch

File Logfile.csv can be opened via spreadsheet directly.


Therefore format of date can be changed.

002-518-3e-01.14 Seite 179


Contents

Menu System Setup 2

From menu system setup 1 with F6.

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field forward

Selects submenu Field bus-Settings. The submenu is depending of the device


Fieldb. configuration (Profibus, Interbus, Device-Net…).Further information refer man-
ual Up- communication.

Enables Up-Download function using COM2 or Ethernet


Rem
(further information refer manual Up-Download-Program)

Edit Edits the selected field

Sys. 3 Switches to the menu System settings 3

End Ends this function and returns to the calibration menu

Setting Description
Here a 10-digit alphanumeric name for the channel can be entered. This name
Channel name appears in the status line
The setting applies only for the selected channel.
Here a 10-digit alphanumeric name for the unit can be entered. This name ap-
Cluster name
pears in the status line
Data transmit Invoke menu: Data transmit RS-232. Allow settings for job number transfered by
RS-232C serial connection to DMF-P.

Page 180 002-518-3e-01.14


Programming and Parameter Entry

The following settings for the Ethernet only refer to the


device configuration and not to the transmission of the
measured values. The settings for the value transmission
are performed in the menu System settings 3:

Setting Description

Network setup of the device. The Ethernet settings for the transmission of values
are found in the System menu 3 under Samba!
Ethernet
For further information about the configuration and setup of connections please
refer to the communication manual.

IP-address Defines the IP-address of the device.

Subnet Mask Defines the Subnet-Mask

Gateway Defines the IP-address for the Internet-Gateway

Webservice Activates or deactivates the service options via the webserver

Time server (ntp) IP-address of server having ntp-service running for synchronization of time

If during activated Samba setting a change of the Ether-


net settings should be effected the following message is
shown:
Network cannot be changed, please deactivate Samba
first!
For a modification, after acknowledging with F7 first
Samba must be OFF in the menu system setup 3. After
that the modification can be performed in the menu
System setup 2, then Samba can be activated again.

For further information please refer to Operation manual


communication.

002-518-3e-01.14 Seite 181


Contents

7.2.2 Menu Data Transmit RS-232C


90B

In menu system setup 2 go to field data transmit RS-232C


and enter the menu with F5.

Description

Deactivate: serial receiving is switched off


Type
Job number: DMF-P will receive the job number as serial data

To choose the target, where the DMF-P will save the serial data:

Target Actual prog.: The serial data will be stored in the actual program

All prog. The serial data will be stored in all programs

To choose the final character, which will determine the end of the serial string

<CR> ASC(13): Carriage Return, ASCII Character Nbr 13


Separator <LF> ASC(10): Line Feed, ASCII Character Nbr 10
<CR><LF> ASC(13) ASC(10): both character in combination
Semicolon: semicolon, ASCII Character Nbr 59
Fix 32 chars: Exactly 32 characters will be read by the dmf-p

Page 182 002-518-3e-01.14


Programming and Parameter Entry

7.2.3 Menu System Setup 3


91B

From the menu system setup 2 with F6.

Setting Description

This setting defines the location of the directory in the network where the measur-
ing and protocol data are saved.

Off: No network drive connection is possible


Client: DMF-P A300 NCF Type 4734A... utilizes network drive from extern
computer.
Server: DMF-P A300 NCF Type 4734A... utilizes own directory. Extern computers
have access on this directory.
Samba
The Client setting is recommended. This ensures that after each measurement the
device DMF-P A300 NCF Type 4734A… automatically sends the actual data.
Like that a synchronisation of the data fetch by the extern computer is not neces-
sary.
In this case the archiving is only limited by the size of the extern memory medium

Under the Server setting the contents of the intern protocol directory can be de-
leted with

Host IP-address Defines the IP-address of the extern computer

Designation of the released folder on extern computer


Release name
(max. 15-digit alphanumeric character string)

User name for the connection to the released folder of the extern computer
User name
(max. 15-digit alphanumeric character string)

002-518-3e-01.14 Seite 183


Contents

Setting Description

Password for the connection to the released folder of the extern computer
Password
(max. 15-digit alphanumeric character string)

Defines the max. number of result files in the device intern directory "shared".

Number of files Value range 1 ... 1 000

Number of files = 0 no limitation effected. As many files are saved until the intern
memory is full, whereby the last measuring result may be lost.

Behavior of device by reaching count of files defined under Number of files or, if
Number of files = 0, the folder is full.
Behavior on limit
Remove Sys.OK: Signal SystemOK will be set to false.
Delete last file: Oldest file will be deleted.

For further information please refer to Communication


manual.

Page 184 002-518-3e-01.14


Programming and Parameter Entry

7.2.4 Menu System Setup 4


92B

7.2.4.1 DMF-P A300 NCF Type 4734A…

From menu System setup 3 with F6.

Setting Description
Activates either the short or the long joining menu
short: 3 position sets
Joining-menu
long: 2 … 16 position sets
Refer to submenu Joining at measurement program

Defines the method of position set transmission to servo controller.


As standard, position data are transmitted to servo controller immediately if there
is a change in program, otherwise before the next measurement, if parameters
have changed. This automatic function can be switched off, then the transmis-
sion must first be requested by an external control signal of PLC.
Only position sets of the actually selected program are transmitted as standard.
Alternatively it can be defined, that all position data up from program 0 can be
Transmit-mode transmitted as single data package. Max. 60 position sets are thereby entered to
the positions 0 … 59. So all position sets for all work pieces are available in the
servo controller, the PLC has only to select these.
program sp. auto: Transmit position sets of selected program automatically.
program sp. external: Transmit position sets of selected program after an exter-
nal signal.
all automatic: Transmit all position sets automatically.
all external: Transmit all position sets after an external signal.

Positions Defines the number of position sets (2 … 16) in the joining menu.

002-518-3e-01.14 Seite 185


Contents

Setting Description
Autom. tare: internal automatically after measurement start
Tare
None: only via PLC-signal
Selection of used servo controller.

Ecodrive
IndraDrive without MLD : Without force control and deformation compensation
Servocontroller
IndraDrive with MLD : With force control or deformation compensation.
Available if IndraDrive standard scope of supply.

Wrong selection disables system to work.


Selection of baudrate for communication between DMF-P A300 NCF
Type 4734A… and servo controller. Possible settings:
Baudrate
9 600, 19 200, 38 400, 57 600, 115 200 Baud
Fieldbus address of servo controller. Is read via serial interface from servo control-
ler.
Address can be changed. Therefor servo controller must be disconnected from
Slave address: fieldbus. Possible value 3 … 99.
Incorrect adress settings can cause fieldbus error or plant shut-down.

Is no servo controller connected or serial connection interrupted – 1 is displayed.


Automatic: Operating mode for automatic station without manual charging.
The automatic brake test is deactivated. In the window the message, "Auto.
mode brake test is deactivated!" is displayed.
To apply the message must be acknowledged twice with "YES".
Manual mode: Operating mode for the manual workstation. The automatic brake
test is activated. In the window the following message is displayed:
Operating mode: "Operating brake test (every 8 hours) is activated. If within 8 hours this is not
possible the drive goes to error status!"
To apply the message must be acknowledged twice with "YES".

Applying and activation of the operating mode are indicated by a marker


" " after the operating mode.

Brake test: Display of the test torque.


If the test torque is not achieved during the brake test, an error message will be
displayed. Contact the Kistler service organization.
Test torque
Compare the displayed testing torque by opening the menu with the testing
torque specified for the NC joining module (see operating instructions 002-518
part 1).

Page 186 002-518-3e-01.14


Programming and Parameter Entry

7.2.4.2 Transmission Mode, Positioning Sets – serial for DMF-P A300 NCF Type 4734A…

Transfer of position sets from DMF-P A300 NCF Type


4734A… to the servo controller is done by serial interface,
independent from the kind of coupling or PLC.

Position sets
For optimizing the transfer time of position sets, the count
of sets must be defined for each program. For all programs
this defined common limitation is fixed. Therefore the max-
imal count of set must be set of the number of sets which
are necessary.

Transmission: Auto – Extn


The standard transmission of position data to the servo
controller is performed automatically, in a program change
immediately, or in a parameter change before the next
measurement. In the system settings, however, this auto-
matic function may be turned off, so that the transmission
must first be requested by an extern control signal of the
PLC. This might be necessary, if the active controller enable
of the servo controller prevents the data transfer.

The transmission is performed through the serial interface


RS-232C-1 (COM1) at DMF-P A300 NCF Type 4734A…

002-518-3e-01.14 Seite 187


Contents

Transmission: Pgm – All


Standard transmission only of the position sets of the cur-
rently selected program. Alternatively it can be determined
that all position data from program 0 up are transmitted as
single data package. The maximally 60 position sets are en-
tered continuously in the positions 0 … 59. Consequently
the position sets for all work pieces are available in the ser-
vo controller, the PLC must only select them. This mode is
recommended for units with frequent type change, to
shorten the cycle time, however 32 programs will not be
available then, The following results:

nPos Number of all pos. sets from Rest 1)


Max. PosSets programs the program from prg. PosSets
2 30 0 … 29 – –
3 20 0 … 19 – –
4 15 0 … 14 – –
5 12 0 … 11 – –
6 10 0…9 – –
7 8 0…7 8 0…3
8 7 0…6 7 0…3
9 6 0…5 6 0…5
10 6 0…5 – –
11 5 0…4 5 0…4
12 5 0…4 – –
13 4 0…3 4 0…7
14 4 0…3 4 0…3
15 4 0…3 – –
16 3 0…2 3 0 … 11

1)
In consequence of the maximum number of position sets
per program, a “rest" will result, which is filled with the
position sets of the next program. The input there will be
limited to the permitted total number.

Position sets 60 … 63 can be used for a home position,


tool change position, etc. independent of the used pro-
gram.

Page 188 002-518-3e-01.14


Programming and Parameter Entry

Position Sets of the Currently Selected Program

Example of 16 position sets (nPos=16)

position set position set


0 0
1 1
2 2
3 3
4 4

servocontroller
5 5
6 6
program 0

7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
NCF

15 15
A400
DMF-P A300
DMF-P NCF

position set
0
1
2
3
4
5
program 31

6
7
8
9
10
11
12
13
14
15

The PLC controls always the same operation by selecting


the same position set sequence. The position data will be
transferred from DMF-P A300 NCF Type 4734A… to the
servo controller depending of the selected program to the
same position set memory location.

002-518-3e-01.14 Seite 189


Contents

Transmitting all 64 Position Sets

Example for 5 position sets: nPos=5

position set position set


0 0
1 1
prg. 0

2 2
3 3
4 4

0 5
1 6
prg. 1

2 7
3 8
4 9

0 10
1 11
prg. 2

2 12
3 13
4 14
NCF

servocontroller
NCF

0 15
A400

1 16
DMF-P A300
prg. 3

2 17
DMF-P

3 18
4 19

0 50
1 51
prg. 10

2 52
3 53
4 54

0 55
1 56
prg. 11

2 57
3 58
4 59

60 60
61 61
all

62 62
63 63

The PLC selects the program at the DMF-P A300 NCF


Type 4734A… depending to the work piece and the corre-
sponding position sets at the servo controller. A single
transfer is only necessary after a change of the position set
input at the DMF-P A300 NCF Type 4734A….

Page 190 002-518-3e-01.14


Programming and Parameter Entry

7.2.4.3 DMF-P A310 Universal Type 4740A…

With F6 from the System settings menu.

Setting Explanation

Joining Menu This setting is used to switch between the long and the short joining menus.
Short: 3 positioning sets
Long: 16 positioning sets
See also the Joining submenu for the measurement program.
Taring Automatic taring: internal after measurement start, automatic
None: Only after PLC signal

Servo Controller IndraDrive Uni

In contrast to the DMF-P A300 NCF, the servo controller is permanently speci-
fied.
Firmware, Servo Servo controller firmware version

002-518-3e-01.14 Seite 191


Contents

Setting Explanation

Operating Mode: Automatic: Operating mode for automation station without hand loading
The automatic brake test is deactivated. The following message appears in the
window: “Automatic operating brake test is disabled!”
To accept, the message must be acknowledged twice with “YES”.
Manual mode: Operating mode for the manual workplace. The automatic
brake test is activated. The following message appears in the window:
“Operating brake test (every 8 hours) is activated. If not possible within 8
hours, the drive goes to error!"
To confirm the operating mode, the message must be acknowledged twice
with “YES”.

The confirmation and activation of the operating mode is displayed by a


" " marker behind the operating mode.
Test Torque: Brake test: Displays the testing torque.
If the testing torque is not reached during the brake test, an error message
appears. Contact the Kistler Technical Service for advice.

Compare the displayed testing torque by opening the menu with the testing
torque specified for the NC joining module used (see operating instructions
002-518 part 1).

Page 192 002-518-3e-01.14


Programming and Parameter Entry

7.3 Calibration
A calibration must be performed to adapt the sensor sig-
nals and measuring ranges to the respective application
and joining device. The setting of the calibration data and
the calibration itself is effected separately for X and Y.

In the device operation the menus for the system settings


are for reasons of compatibility under the calibration
menu. They are explained in a separate chapter 7.2.

7.3.1 Calibration Menu


94B

Calibration and adaptation of the sensor signal, measuring


ranges to the application.

Key Abbreviation Menu function


X Switches to the menu Calibration X-axis

Y Switches to the menu Calibration Y-axis

Sys. Switches to the menu System setup 1

End ends the calibration menu

002-518-3e-01.14 Seite 193


Contents

7.3.2 Menu Calibration of the X-axis Absolutely SSI


95B

The device is factory configured for the respective dis-


placement sensor. Only the measuring range and the sen-
sor specific values must be adjusted.

Invoke submenu
Referencing
position

In the DMF-P A310 Universal Type 4740A… the SSI


card is not equipped by default.The X value is trans-
ferred directly from the servo controller via the field
bus. The setting in bits per unit is not possible in this
case, but rather only the setting of the resolution. If an
SSI card is used to connect to an external displacement
sensor, this restriction does not apply.

Setting Description
Sensor Type SSI factory configured

Measuring Over Kind of measurement over displacement or time

Decimal Places Decimal places, presented for measured values: 1 – 2 – 3

Input of the measuring range


The value may vary from the measuring range of the displacement sen-
sor, however, it must be below or equal to the max. measuring range of
the displacement sensor.
Measuring Range

Caution: In all programs overwrites the program dependent setting in


the Parameter menu.

Input of measurement direction

Normal measuring direction


Displacement Inverse
Inverse measuring direction

For Inverse the transmitter value is displayed with inverted (negative)


sign.

Page 194 002-518-3e-01.14


Programming and Parameter Entry

Setting Description

The input of the resolution of the SSI signal can either be effected through
the Bits per unit or through the linear resolution of the transducer. The re-
spective other not relevant input quantity is zeroed and ignored.

Bits per unit indicates the Bits of the SSI signal for the resolution of an X-
Bit per Unit
unit (e.g. 1 mm).
Example: 12 Bit per unit and a 24 Bit SSI-signal (dimension unit should be
alternative
mm) results in a resolution of 1/212mm = 0,244 μm
The value range that should be displayed is ±211mm = ±2 048 mm
resolution
Resolution indicates which change of length equals an increment of the SSI
–signal.

For the DMF-P A310 Universal Type 4740A… only the resolution can be
set. The setting value of the system is 0,100000 μm.

Left start point of the X-axis in the diagram


X-Diagram range Min
Caution: Overwrites in all programs the program dependent setting in the
Parameter menu

Right end point of the X-axis in the diagram


X-Diagram range Max
Caution: Overwrites the program dependent setting in the Parameter menu
in all programs.

Transmission Code Setting corresponding to the output code Binary or Gray used by the sensor.

Input of the global x-offset. This value will be added to the actual sensor
Global X-Offset
values in each program. It can be set automatically with a master sample.

With a master sample, the global x-offset will be set automatically. It is


used, to set a certain position to a fixed value, which is entered in this field.
Additionally, you have to choose, if a master sample is allowed or not. If you
Master Sample start a master sample with the digital input "master sample", the displace-
ment value will be recorded, when the digital input “measuring stop” goes
high. This displacement value will be set to the master sample value. The
calculated offset is automatically set to the “global-x-offset” field.

A calibration like for example in resistive sensors is not


required.

002-518-3e-01.14 Seite 195


Contents

Submenu Referencing Position

Description
Input of value to which the actual position should be set after referenc-
Referencing pos.
ing.

Display of the actual value of sensor position, actual position of joining


Sensor pos.
unit.

Display of Offset displacement of last referencing. After successful refer-


Offset displacement encing, the difference of input value Referencing pos. and position be-
fore referencing is displayed here.

Running referencing:

1. Interlock of servo controller must be off.


2. Calculation of input value of Referencing pos. . There-
fore the difference between actual position (Sensor
pos.) and the type specified zero point of the joining
unit must be calculated. The zero point of the joining
unit is listed in manual electromechanical joining unit
for each type.
3. Input of calculated value of Referencing pos.
4. Press key F6 for referencing (notice safety requests ).
5. After successful referencing Sensor pos. is set equal to
Referencing pos. and Offset displacement shows dif-
ference of input value Referencing pos. and position
before referencing.

Attention! Wrong referencing can cause damage or


destroying of the joining unit.

Page 196 002-518-3e-01.14


Programming and Parameter Entry

7.3.3 Menu Calibration of the X-Axis Incremental


96B

The device is factory configured for the respective dis-


placement sensor. Only the measuring range and the sen-
sor specific values must be adjusted.

Setting Description
Sensor Type incremental factory configured

Measuring Over Kind of measurement over displacement or time

Decimal Places Decimal places, which are displayed for measured values: 1 – 2 – 3

Start point of the measuring range (lowest waypoint in the measuring


range).
Measuring Range Min
Caution: Overwrites the program depending setting in the Parameter
menu in all programs

End point of the measuring range (highest waypoint in the measuring


range).
Measuring Range Max
Caution: Overwrites the program dependent settings in the Parameter
menu in all programs.

Left start point of the X-axis in the diagram


X-diagram Range Min Caution: Overwrites the program depending settings in the Parameter
menu in all programs

Right end point of the X-axis in the diagram


X-Diagram Range Max Caution: Overwrites the program depending setting in the Parameter
menu in all programs

002-518-3e-01.14 Seite 197


Contents

Setting Description
Input of measuring direction

Normal measuring direction


Displacement Inverse
Inverse measuring direction

In Inverse the transmitted value is displayed with inverted (negative)


sign.

Entry of the resolution in μm


Resolution
On x-measuring unit "degree", the entry is effected in ppt (pulses per
turn), whereby here each single signal shoulder is counted as "pulse".

If the applied displacement transducer has got reference points, it can be


entered which reference point is applied as start point for the measure-
Reference Point
ment. A displacement sensor without reference point requires the input
"0".

Input of the global x-offset. This value will be added to the actual sensor
Global X-Offset
values in each program. It can be set automatically with a master sample.

With a master sample, the global x-offset will be set automatically. It is


used, to set a certain position to a fixed value, which is entered in this
field. Additionally, you have to choose, if a master sample is allowed or
not. If you start a master sample with the digital input "master sample",
Master Sample
the displacement value will be recorded, when the digital input "measur-
ing stop" goes high. This displacement value will be set to the master
sample value. The calculated offset is automatically set to the "global-x-
offset" field.

Used for monitoring the basic position of an incremental displacement


sensor (similar to the resistive displacement sensor).
If activated: a position can mechanically be activated and be transferred
with key "Ref" (F6). Alternatively, the value can be edited in the entry
box.
Warning: Transfer reference position only subsequent to a measurement,
Reference Position so that an absolute reference of the way coordination is already pro-
duced (if need be under consideration of the reference points of the
sensor). Conduct a self-monitoring (system test) with activated reference
position categorically under the same determining factors, i.e. subse-
quent to a measurement with same reference points and with the
MEASURE_START-signal at the same position as on the measurement
prior to taking over of the reference position.

Maximum permissible difference (in %) from the calibrated reference


position (basic position) for the current basic position (checking on self-
Zeropoint Tolerance monitoring).
Sensor defects or wrong positioning can consequently be identified.
Standard Value: 5 %

Page 198 002-518-3e-01.14


Programming and Parameter Entry

A calibration such as for resistive sensors is not necessary.

Contrary to the DMFP-V3 a program depending X-offset


input is performed directly in the Parameter menu of the
respective program. The function corresponds with
DMF-P V3.

If a reference point (e.g. 1) is set, the recording of the


curve is effected only after the reference point has been
reached, otherwise the incremental counter is set to zero at
Start.

Ref.-Point
Displacement transducer 100 mm

Measuring range 50 mm

0 50 mm

002-518-3e-01.14 Seite 199


Contents

7.3.4 Menu Calibration of the Y-Axis Active 0 ... 10 V


97B

For Piezo Force Sensors with External Charge Amplifier.

The device is factory configured for an active force sensor.


The characteristic value of the sensor, the measuring and
diagram range must be adjusted and calibrated.

Parameter Description
Sensor Type Force: 10 V factory configured

Decimal places Decimal places presented for measured values 1 – 2 – 3

Measuring range Measuring range of the sensor from calibration certificate

Exceeding this tolerance SysOK (System-OK) will be set false. The value
Zero point tolerance is depending to calibrated zero point.
Recommended value 5 %

Characteristic value Characteristic value of the sensor from calibration certificate

Lower start point of the Y-axis in the diagram


Y-diagram range Min Caution: In all programs overwrites the program dependent setting in
the Parameter menu

Upper end point of the Y-axis in the diagram


Y-diagram range Max Caution: In all programs overwrites the program dependent setting in
the Parameter menu

Supply voltage standard 24 V factory configured.


Other supply voltages are possible optionally.

Page 200 002-518-3e-01.14


Programming and Parameter Entry

The calibration of the force sensor is a zero point ad-


justment.

After each change of the measuring range or the sensi-


tivity a calibration (F6 key) must be performed.

[Cali] starts the calibration process


(zero point adjustment)

If the sensor is unloaded operate F1.

The sensor adjustment is performed and the result dis-


played.

002-518-3e-01.14 Seite 201


Contents

7.3.5 Menu Calibrating the Y-Axis Strain Gage


98B

The device is factory configured for a strain gauge force


sensor. The characteristic value of the sensor, the supply
and the measuring range/diagram range must be adjusted
and calibrated

Parameter Description
Sensor type Strain gage factory configured

Decimal places Decimal places, which are displayed in measured values 1 – 2 – 3

Measuring range Measuring range of the sensor from calibration certificate

Exceeding this tolerance SysOK (System-OK) will be set false. The value
Zeropoint tolerance is depending to calibrated zero point.
Recommended value 5 %

Sensitivity Characteristic value of the sensor from calibration certificate

Lower start point of the Y-axis in the diagram


Y-Diagram view min
Caution: Overwrites the program dependent setting in the Parameter
menu in all programs

Upper end point of the Y-axis in the diagram


Y-Diagram view max
Caution: Overwrites the program dependent setting in the Parameter
menu in all programs
Supply voltage (bridge supply voltage) of the sensor
2,5 V – 5 V – 10 V – 20 V
Excitation
Max supply voltage of the sensor (see sensor data sheet) must not be
exceeded! Default setting (±)2,5 V

Page 202 002-518-3e-01.14


Programming and Parameter Entry

The calibration of the force sensor is a zero point adjust-


ment.

After each change of the measuring range or the sensi-


tivity a calibration (F6 key) must be performed.

[Cali] starts the calibration process


(zero point adjustment)

If the sensor is unloaded operate F1.

The sensor adjustment is performed and the result dis-


played.

Deviation <10 % => Sensor OK


Deviation >10 % => check Sensor

002-518-3e-01.14 Seite 203


Contents

7.3.6 Menu Calibration of Y-Axis Piezo


9B

The device is factory configured for a Piezo-force sensor.


The characteristic value of the sensor and the measuring
range/diagram range must be adjusted.

Parameter Description

Sensor Type Piezo factory configured

Decimal Places Decimal places, shown in measured values 1 – 2 – 3

Measuring Range Measuring range of the sensor from calibration certificate

Characteristic value of the sensor from calibration certificate


Sensitivity
Notice: Model NCFH sensitivity negative.

Lower start point of the Y-axis in the diagram

Y-Diagram View min Caution: Overwrites the program dependent setting in the Parameter
menu in all programs

Upper end point of the Y-axis in the diagram


Y-Diagram View max
Caution: Overwrites the program dependent setting in the Parameter
menu in all programs

Page 204 002-518-3e-01.14


Programming and Parameter Entry

After each change of the measuring range or the sensitiv-


ity a calibration (F6 key) must be performed.

[Calib] starts the calibration process (adjustment)

If the sensor is unloaded operate F1.

The sensor adjustment is performed and the result dis-


played.

002-518-3e-01.14 Seite 205


Contents

7.3.7 Calibration Menu for the Y Axis with Two-Range Loading Amplifier
The device if preconfigured at the factory for an external
two-range loading amplifier for Piezo force sensors. The
key values of the loading amplifier and the measurement
ranges or the diagram range must be set.

Parameter Explanation
Sensor Type PiezoKistler preconfigured at factory
Decimal Places Decimal places displayed for measurement values 1 – 2 – 3
Measurement Range 1/2 Measurement range of the sensor from the calibration certificate

Measurement range 1 must be configured as the larger measurement


range. If a larger value is set for measurement range 2 than for meas-
urement range 1, the measurement ranges are automatically exchanged.

The specifications during calibration always refer to measurement range


1.
Key Value 1/2 Key value (output voltage) of the loading amplifier at the force defined
under the measurement range.

Note: The key value is negative for the series NCFH Type 2151B….
Zero Point Tolerance Tolerance which, when exceeded, leads to loss of SysOK (system OK)
during the test. The value refers to the zero point tared during calibra-
tion.
The usual value is 5 %.

Page 206 002-518-3e-01.14


Programming and Parameter Entry

Parameter Explanation
Y diagram range min. Lower starting point of the Y axis in diagram

Note: Overwrites the program-dependent parameter setting in all pro-


grams.
Y diagram range max. Upper end point of the Y axis in diagram

Note: Overwrites the program-dependent Parameter setting in all pro-


grams.
Invert measurement range The working method of the control signal for measurement range
signal switchover can be adapted with this function.

Measurement range 1, high active (measurement range 2, low ac-


tive)

Measurement range 1, low active (measurement range 1, high ac-


tive)

Piezo reset signal Selection for configuration of the reset signal for the external loading
amplifier

Low: Low active rest of the loading amplifier based on device status
(measurement started/ended…)
High: High active rest of the loading amplifier based on device status
(measurement started/ended…)
External Low: Low active reset of the loading amplifier based on the Y-
zeros input signal. Y-zeros active (high) = reset
External High: High active reset of the loading amplifier based on the Y-
zeros input signal. Y-zeros active (high) = reset

Setting for mini-loading amplifier (NC joining module


Type 2151B…):

Measurement range 1: High active (no inversion)


Reset: High or External High

Setting for loading amplifier ICAM Type 5073A…

Measurement range 1: Low active (inversion)


Reset: Low or External Low
See also the data sheets of the individual loading ampli-
fiers.

002-518-3e-01.14 Seite 207


Contents

After every change in the measurement range of the


sensitivity, a calibration (F6 key) must be performed.

[Calib] starts the calibration process (reconciliation)

If the sensor is unloaded, please press F1.


The sensor reconciliation is performed and the result is
shown on the display.

Page 208 002-518-3e-01.14


Programming and Parameter Entry

7.4 Control and Service


34B

For putting into operation and control the signals of the


unit can be visualized with the Service menu.

7.4.1 Service Menu


10B

In this menu the most important input and output signals


of the DMF-P A300 NCF Type 4734A… are visualized. The
function corresponds with the signals at the PLC connec-
tion (parallel interface), and the Fieldbus-signals.
Generally:  Signal not active (low)
 Signal active (high)

Piezo force sensor


zero position

Displacement Measured value


actual position force sensor

002-518-3e-01.14 Seite 209


Contents

Signal Description

M.Start Switching on the measuring data recording (measurement start)


Switching off the measuring data recording and evaluation of the measuring win-
M.Stop
dows.

Sys.Test Test sequence, intern system test and resetting of an error (if possible)

zero Y The force-zero point was defined by extern resetting (Tara)

zero X The displacement zero point was defined by extern resetting (Tara)

Prg.0 … Prg.4 Bit coded program selection

P= xx Program selection as decimal

OK Measurement OK, overall evaluation of all tolerance windows

NOK (NIO) Measurement NOK, overall evaluation of all tolerance windows

Ready The device is ready for operation, equals the message SystemOK

Cycle end Cycle end, measuring cycle is ended and evaluated

YTS Measurement was started by force-triggering

YTE Measurement was ended by force triggering

XTE Displacement trigger threshold exceeded, output signal is set


Is set after end of a measurement, if during this measurement the reference point of
Ref an incremental displacement sensor was detected. Test sequence or start of a meas-
urement deletes this signal.

DPini Fieldbus module is initialised (Hardware operable, communication setup)

DPonl Fieldbus module communication active (Master online)

Servo valid Parameter transmission to servo controller. Parameter valid.


Automatic and Move operating only to „servo valid“ possible. See also PLC function
block.
F1 … F4 Min-/Max-evaluation of the tolerance windows 1 … 4, independent of type

The displays of actual positions and force sensor meas-


ured value are frozen during a measurement, and up-
dated subsequently.

Page 210 002-518-3e-01.14


Programming and Parameter Entry

7.5 Documentation and Statistic


35B

Besides the actual display (Diagram or measured values:


table) there are additional standard documentation- and
evaluation functions available, which allow at any time an
optimal process diagnosis on site without the need of addi-
tional evaluation software. Process data can be printed out
at any time or transmitted to a process control system. Pa-
rameter entries, activation and presentation are effected in
the menu range documentation.

7.5.1 Documentation Menu


10B

Parameter entry, activation and presentation of the docu-


mentation and evaluation functions.

Key Abbreviation Menu function


Error Error messages as plaintext indication

Print Printout setup

Proto Adjust measured value protocol

Memo Invoke the protocol memory

Stat Invoke the statistic function

DMem Invoke the diagram memory

End End, return to the measurement menu

002-518-3e-01.14 Seite 211


Contents

7.5.2 Menu Error Messages


102B

Display of all error messages in plaintext.

DMF-P A300 NCF Type 4734A… DMF-P A310 Universal Type 4740A…

Key Abbreviation Menu function


Start the device self test, corresponds to the control signal test sequence.

Test A self-test is performed and all the detected errors are listed as plaintext mes-
sage. Besides the plausibility of the parameter entry a function test of the con-
nected sensors is performed as well.

Enhanced test sequence for troubleshooting at the wiring PLC-interface (only in


existing digital I/O module.
Check
In addition an inspection of the supply voltage in the device is performed.

S-Res. Quittierung von Fehlern des Servocontrollers

End Ends the menu error messages

After the troubleshooting either the function test must be


called up again, or a PLC-controlled test sequence must
be started, since errors must be acknowledged in any
case.

In the display in this case the text "no error" is shown.

Page 212 002-518-3e-01.14


Programming and Parameter Entry

List of Possible Error Messages in the Test Function:

Error text Description

No window has been pro- In the selected measuring program the set point defaults of the activat-
grammed ed windows are zero or no window is activated.
At least one window with a pair of set point values (X/Y) >0 must be
activated for the measurement.

Window number. 1 … 8 in
If the respective window in X-direction is more than twice the defined
X-direction over-
measuring range in X-direction
dimensioned

X-zero deviation
An X-deviation of position in the basic position higher than the permit-
ted tolerance (see calibration X) was recognized.

Y-zero deviation
A Y-deviation of position in unloaded condition (basic position) higher
than the permitted tolerance (see calibration Y) was recognized.

X-calibration incorrect
Error in the calibration of the X-axis (e.g. no stable position was recog-
nized or defective sensor). Calibration routine not completed or abort.

Y-calibration incorrect
Error in the calibration of the Y-axis (e.g. sensor was not unloaded or is
defective). Calibration routine not completed or abort.

Displacement-measurement For the actual measurement method, the necessary displacement-


plug in missing measurement plug in was not detected.

Force-measurement plug in For the actual measurement method, the necessary force-measurement
missing plug in was not detected.

Samba-client: No access on interrupted. The device cannot file result files.


the network The network connection to the host (extern memory location) is

Samba-server memory is full The max number of file entries defined in the system menu 3 in the
device intern directory "shared" is reached.

measurements, a warning appears when 20 % of the max number


Warning: Files contained in If temporarily the result files are not picked up after the respective of
the Samba server memory files defined in the system menu 3 is reached.

002-518-3e-01.14 Seite 213


Contents

Error text Description

Memory card is full If no max. number of file entries in the Samba server
memory under system menu 3 was defined, and the files
were not picked up, the result files are internally filed until
the memory is full.

This message appears if no result can be saved any more.


Most likely the last measuring result will be lost.

Warning: Memory card will be full soon If no max. number of file entries in the Samba server
memory under system menu 3 was defined, and the files
are not picked up, the result files are intern saved and
before the state "memory card is full" a warning appears.

I-P.M.-Gateway not accessible The network connection to the I-P.M.-Gateway is inter-


rupted. The device cannot file any result files.

For further information about the communication and its


setting please refer to System menu 2 and System menu
3 and to the communication manual.

Error text Description


24 V not available
Supply of the extern 24 V for digital I/O-module is miss-
ing (e.g. wiring error, cable failure…)
Short-circuit at the 24 V output recog-
Short-circuit at an output of the digital I/O module (e.g.
nized
wiring error, damaged cable...)

Deviation from the digital 5 V reference


Device-intern control
voltage

Deviation from the analog 5 V reference


voltage Device-intern control

Deviation from the analog 15 V reference


Device-internal control
voltage

Deviation from the analog 15 V refer-


Device-internal control
ence voltage

Page 214 002-518-3e-01.14


Programming and Parameter Entry

7.5.3 Printout Menu


103B

Setting and activation of the printout:

Key Abbreviation Menu function


LPT Printing to parallel-interface (LPT)

COM2 Serial printing to COM1, printout with multiple lines (CRLF)

ETH Text-file out to Ethernet-interface

SysC Additional selection for system configuration printout

End End, return to the documentation menu

Program data (Set points, parameters etc.) will be printed


always. Selection Print all enables printing of device
settings (System setup1..., Calibration X…).

002-518-3e-01.14 Seite 215


Contents

7.5.4 Protocol Menu


104B

Setting and activation of the protocol

Parameter Description
NOK Automatic serial output of the measuring data of all parts evaluated
NOK at COM1 after the respective measurement.
Measuring results evaluated OK are not reported.
OK + NOK serial output of all measuring results, independent of the
RS232 -> evaluation OK or NOK at COM1 after the measurement.
OFF Output deactivated.
Output format: SerProt output in one line
SerDruck output in several lines (like LPT)

OFF output is deactivated


NOK automatic output of measuring data of all the parts evaluated NOK
after the respective measurement as ASCII file via Ethernet into the direc-
tory specified in system menu 3 (Client setting).
Measuring results evaluated OK are not documented.
OK + NOK automatic output of all measuring results, independent of the
evaluation OK or NOK after the measurement via Ethernet, into the
directory specified in system menu 3 (Client setting)as ASCII file.

Ethernet -> Output format: one line output in one line


multi line multi-line output
The file name is composed of:
Meas_CX_Channel name_Date_Time_Job number.txt
X = channel number (1 ... 8, Master 1 or 2, Client 3 ... 8)
Channel name = Entry from System menu 2
Job number = Entry from the parameter menu or job transmitted via
fieldbus Example: Meas_C1_Channel1_2005-10-25_14-40-19_A123.txt
Please refer to the note further below!

Page 216 002-518-3e-01.14


Programming and Parameter Entry

Parameter Description
NOK Automatic printout of the measuring data of all parts evaluated
NOK after the respective measurement.
Measuring results evaluated OK are not reported.
LPT OK + NOK Automatic printout of all measuring results independent of
evaluation OK or NOK.
OFF output deactivated
HP-PCL3-compatible printer to LPT

NOK Intern protocolling of the measuring data of all parts evaluated


NOK
Measuring results, which are evaluated OK, are not reported.
OK + NOK Intern protocol of all measuring results, independent of the
Protocol Memory evaluation OK or NOK
OFF protocolling deactivated
Maximally 1 000 measuring results can be collected. If the memory is full
the oldest result is overwritten with the new values (FIFO-principle).

NOK Intern protocolling of the curves of all parts evaluated NOK


Measuring results evaluated OK are not reported
OK+ NOK intern protocolling of all curves independent of the evalua-
Diagram Memory tion OK or NOK
OFF protocolling deactivated
Maximally 100 curves can be collected. If the memory is full the oldest
result is overwritten with the new result (FIFO).

ON Statistic activated
Statistic
OFF Statistic deactivated

ON A file with the number of XXX pairs of values X/Y of the curve is
created in the CSV-format and saved via Ethernet into the directory
specified in system menu 3.
The number of pairs of values XXX can be selected between 25 and
1 000.
If during a measurement, less pairs of values are collected than specified
for the output, interpolation points are included to obtain a constant
data format.
OFF Output deactivated
Entries CSV-File
The file name is composed of:
Meas_CX_channel name_date_time_job number.txt
X = channel number (1 ... 8, master 1 or 2, Client 3 ... 8)
Channel name = entry from the system menu 2
Job number = entry from the parameter menu or job number transmitted
via fieldbus
Example: Meas_C1_channel1_2005-10-25_14-40-19_A123.csv

Selection of the decimal separation sign for the CSV-file

Decimal Separation Comma (X,XX; X,XX;)'


Point (X.XX; X.XX;)
Point (X.XX, X.XX,)

002-518-3e-01.14 Seite 217


Contents

Parameter Description

Setup of I-P.M.-protocol is done at submenu I-P.M.-setting. The sub-


menu can be invoke pressing F5 during cursor is located at line I-P.M.-
I-P.M.-Protocol logging of menu Documentation.

For further details please refer to communication manual.

Setup of q-das-protocol is done at submenu Q-Das setting. The sub-


menu can be invoke pressing F5 during cursor is located at line Q-Das-
Q-DAS Protocol protocol of menu Documentation.

For further details please refer to communication manual.

The configuration of the respective protocol files is de-


scribed in the communication manual.

Page 218 002-518-3e-01.14


Programming and Parameter Entry

7.5.5 Menu Protocol Memory


105B

In the protocol memory, the measuring results of maximal-


ly 1 000 measurements can be stored. If the memory is full,
the oldest measurement is automatically overwritten.

Key Abbreviation Menu function


Moves the cursor one field back

Moves the cursor one field forward

Delete Deleting of all measuring data in the protocol memory after a security query.

Displ Display of the stored measuring data in format with several lines

Editing selected input:

Measurements: XXX Defines how many of the finally traced measuring proto-
cols will be send to output. First (oldest) measuring will be send first. Input
1 … 1 000

Send type: Defines media


Edit Serial single-line
Serial multi-line
Eth. single-line
Eth. multi-line
LPT multi-line

Serial to COM1, Eth. to Ethernet, using directory defined at System setup 3


(Client-Setup) LPT to printer.

The number of the selected measurement results will be transmitted to the


Send
specified media.

End Ends the menu protocol memory

002-518-3e-01.14 Seite 219


Contents

7.5.6 Menu Diagram Memory


106B

In the diagram memory maximally 100 measuring curves


can be filed. If the memory is full the oldest curve is over-
written.

Key Abbreviation Menu function


Cursor to the left

Cursor to the right

Select the next curve

Select the previous curve

Funct. Invokes the submenu for deleting or printing.

Switches to the zoom mode (refer to 7.3.3.). The zoomed presentation is not
Zoom
saved here.

End Leaving the menu diagram memory

Page 220 002-518-3e-01.14


Programming and Parameter Entry

Submenu for Deleting and Printing in the Diagram


Memory

Key Abbreviation Menu function


Delete Deleting all curve data in the diagram memory after a security query.

Saving the displayed curve into the directory specified in system menu 3
1>eth
(Client-setting) via Ethernet

Output of all curves from the diagram memory into the directory specified in
A>eth
system menu 3 (Client-setting) via Ethernet.

1>Lpt Print screen on lpt-device.

End Leaving the sub-menu

002-518-3e-01.14 Seite 221


Contents

7.5.7 Statistic Menu


107B

Separate statistic functions for each of the 32 measuring


programs. If for example only incorrect measurements are
reported it is possible to obtain a quick overview of the
failure rate

Key Abbreviation Menu function

Delete Deleting the statistic data after a security query for the selected program

Cursor to the next input field

Prg+ Select the next program

Pgr- Select the previous program

Edit Edits the selected field


Presentation of histogram of the selected program (refer to submenu histo-
Histo.
gram)
End Leaving the statistic menu

Page 222 002-518-3e-01.14


Programming and Parameter Entry

Function Description

Status Status information about the statistic

The status valid is displayed if there have been no modifications effect-


ed at the program data (setpoint records) since the initialisation of the
statistic.

If the program data were changed without deleting the statistic after-
wards, the collected measurements are not based on the same evalua-
tion rules and the statistic is marked invalid.

7.5.7.1 Submenu Histogram


In each window the distribution of min- and max values is
presented graphically as a histogram (bar chart)

Therefore each window is divided in five intervals of the


same size, two classification intervals of the same size are
created additionally above and below the window.

Force-displacement windows:
F [kN]

K0
F max K1
K2
K3
K4
K5
K6
F min
K7
K8

Force windows:
s min s s max s [mm]

002-518-3e-01.14 Seite 223


Contents

F [kN]

K0
K1
F max K2
K3
K4
K5
K6
F min
K7
K8

s [mm]

Displacement windows:

K0 K1 K2 K3 K4 K5 K6 K7 K8
F [kN]

s min s max s [mm]

Page 224 002-518-3e-01.14


Programming and Parameter Entry

Key Abbreviation Menu function


Fe+ Selection of the next window for histogram display

Fe- Selection of the previous window for histogram display

End Exits the histogram display

In the statistic distribution in case of force-displacement


windows only the measurements are collected, in which
both min-value and max value fall in one of the 9 classifi-
cation intervals.

In pure force or displacement windows only the respective


maximum (displacement end or block force) are classified.

In the example above: force-displacement window.

002-518-3e-01.14 Seite 225


Contents

The following is displayed

 the evaluation results of the statistic distribution at:


 FORCE-DISPLACEMENT WINDOWS of maximal and
minimal force value of each measurement in each of
these windows.
 FORCE WINDOWS of the block force regarding each
of these windows (as max-distribution)
 DISPLACEMENT WINDOWS of the DISPLACEMENT-
end regarding each of these windows (as max-
distribution)
 the number n of the arithmetically collected values of
which the arithmetic average value mw and the stand-
ard deviation sa. Measured values outside the window
borders are disregarded (the values are displayed on top
of the histogram of the respective window).

Average value mw and standard deviation sa are calculated


with the following formulas:


1
mw  · X i (Xi = Messwerte)
n i1


1
sa  · (X i – mw) 2
n – 1 I1

Page 226 002-518-3e-01.14


Manual Control with DMF-P A310 Universal Type 4740A...

8. Manual Control with DMF-P A310 Universal Type 4740A...


With manual control using the DMF-P A310 Universal
Type 4740A… it is possible to move the NC joining module
even without a system PLC.

When this function is called up, the PLC no longer has


access to the NC joining module. The user is responsi-
ble for the movement of the NC joining module and
the interplay between any system processes.

Suitable safety measures, such as two-hand start, pro-


tective grid, etc., must be provided by the manufactur-
er of the machine or system ready to be used and must
implement them in the control circuit according to the
determined risk category. The safety circuit must be
activated during use of the NC joining unit.

EMERGENCY STOP switches must be connected ac-


cording to the safety and switching instructions of the
servo controller.

The valid guidelines, norms, and accident prevention


regulations must be observed.

Non-compliance can lead to serious injury to persons


and damage to property.

The system may not be used in machine areas with a


risk of explosion without ex protection.

When working in the travel area of the tappet, the


main switch for the entire machine must be switched
off to ensure that the power section of the servo con-
troller is switched off.

The safety instructions of the operating instructions


002-518 part 1, Electromechanical NC joining module
must be observed.

002-518-3e-01.14 Seite 227


Contents

8.1 Control Menu


The Control menu can be called up by pressing the key from
the menus Measurement values: Table, Diagram and Service.

The following message is displayed when it opens.

The Control menu is displayed after confirmation by pressing


the key.

Activating the Control menu switches off power to the


servo controller, and it must be switched on again in
the respective submenu.

This also applies to switching between the submenus,


e.g. from Service to Automatic.

Page 228 002-518-3e-01.14


Manual Control with DMF-P A310 Universal Type 4740A...

Key Abbreviation Menu function


Serv. Service (jog mode)

Move Step mode

Auto Automatic mode

End Leave the Control menu

The following message menu is displayed when


you leave the Control menu by pressing the key.

Confirm exit with key.

When the Control menu is closed, the power to the


servo controller is switched off and must be switched
on again from the system PLC.

002-518-3e-01.14 Seite 229


Contents

8.1.1 Service Menu (jog mode)

The Service (jog mode) menu can be opened by


pressing the key from the Control menu.

Key Abbreviation Menu function


- Jog -

+ Jog +
Approach the zero position
-0-
(reference position)
Measurement Switchover between meas-
range urement ranges 1 and 2
Processing of the travel
Process
speed in jog mode
Switch power of servo con-
Power
troller ON/OFF
End Exit the service menu

Parameter / display Description


Position Display of the actual position
Force Display of the actual force
Measurement range X Display of the selected measurement range by the marker " ".
Speed Travel speed in jog mode. The value range is 0.01 … 10.00 mm/s.
Diagnosis Display of the status message of the servo controller

Page 230 002-518-3e-01.14


Manual Control with DMF-P A310 Universal Type 4740A...

Display Description
Power On Display of the status of the power connection switch.
Marker " " = power ON.
Stationary Displays whether the NC joining module is stationary.
Marker " " = stationary.
-0 - reached Displays whether the (mechanical) zero position has been reached.
Marker " " = zero position reached.

For reasons of safety, YTE should always be set above


the expected force value or at the nominal joining force
of the module.

For reasons of safety, XTE should always be above the


expected travel distance or at the nominal travel dis-
tance of the module.

With the key combination (press keys simultaneously):

Manual grinding in of the brakes is possible in the Service


(jog mode) menu.
This can be necessary in certain circumstances when an
error occurs during the brake test.
A brake test must be performed after this.

002-518-3e-01.14 Seite 231


Contents

8.1.2 Move Menu (stepping mode)

The Move menu (stepping mode) can be opened


from the Control menus.

Key Abbreviation Menu function


Moves cursor one field back-
wards

Moves cursor one field forward

Starts the movement and


Start must me pressed down dur-
ing the entire movement
Starts the measurement,
Meas. pressing again stops the
measurement
Process the selected field for
Process
value entry
Switch power of servo con-
Power
troller ON/OFF
End Exit the Move menu

Parameter Description
Program no. Selection of the desired program by entering the corresponding program
number.
Position set Selection of the desired position set by entering the corresponding set num-
ber.

Page 232 002-518-3e-01.14


Manual Control with DMF-P A310 Universal Type 4740A...

Parameter Description

No home check Selecting No Home Check switches the test of the basic position to automat-
ic mode if a defined position was previously approached in stepping mode
(Move). Marker " " = No Home Check.

When No Home Check is activated, it remains set. The basic position is not
controlled again until after the function is deactivated.
Deactivation, stationa- Selecting Deactivation, stationary suppresses the stationary signal of the
ry servo controller. Marker " " = Deact. stat. .
(Deact. stat.)
This makes it possible to continue the started measurement rather than hav-
ing it ended with the stationary signal. In exactly the same way, the setting
time is not started in this case.

Display Description
Position Display of the actual position
Force Display of the actual force
Diagnosis Display of the status message of the servo controller
Power On Display of the status of the power connection switch.
Marker " ;" = power ON.
Stationary Displays whether the NC joining module is stationary.
Marker " " = stationary.
Position reached Display of whether the position specified for the movement has been
reached.
Marker " " = position reached.
Cycle end Display of whether the course of the started cycle has been ended.
Marker " " = cycle end reached.
Measurement-ready Display of whether the device is ready for measurement.
Marker " " = measurement-ready.
XTE Display of whether the measured distance has exceeded the XTE trigger
threshold and the XTE output has been set.
Marker " " = XTE trigger actuated.
YTE Display of whether the measured force has exceeded the YTE trigger thresh-
old and the XTE output has been set.
Marker " " = YTE trigger actuated.

For reasons of safety, YTE should always be set above


the expected force value or at the nominal joining force
of the module.

For reasons of safety, XTE should always be above the


expected travel distance or at the nominal travel dis-
tance of the module.

002-518-3e-01.14 Seite 233


Contents

8.1.3 Automatic Menu

The Automatic menu can be called up by pressing the key


F3 from the Control menus.

Key Abbreviation Menu function


Moves cursor one field back-
wards

Moves cursor one field forward

Starts the movement and


Start must me pressed down dur-
ing the entire movement

Process the selected field for


Process
value entry
Switch power of servo con-
Power
troller ON/OFF
End Exit the Automatic menu

Parameter Description

Program no. Selection of the desired program by entering the corresponding program
number.
HomePosSet Selection of the desired position set for the basic position by entering the
corresponding set number.
StartPosSet Selection of the first position set with which the movement should start by
entering the corresponding set number.
MoveHomeMode Selecting the condition for return travel to the basic position.

Always: The system moves automatically to the basic position at the end of
the cycle regardless of the evaluation result.
Only for IO: The system moves automatically to the basic position at the end

Page 234 002-518-3e-01.14


Manual Control with DMF-P A310 Universal Type 4740A...

of the cycle only with IO evaluation result. For an NIO result, the system
must be manually restarted for the return trip to the basic position.
Manual: Regardless of the evaluation result, the return trip to the basic posi-
tion must be started manually.
ContinueMeasurement Select ContinueMeasurement to perform the measurement from every posi-
tion in automatic mode. Marker " " = ContinueMeasurement.
The measurement is ended according to the settings for automatic mode.

This setting only applies for one cycle and must be set before the start of the
cycle if necessary.

Display Description
Position Display of the actual position
Force Display of the actual force
Diagnosis Display of the status message of the servo controller
Power On Display of the status of the power connection switch.
Marker " " = power ON.
Stationary Displays whether the NC joining module is stationary.
Marker " " = stationary.
Position reached Display of whether the position specified for the movement has been
reached.
Marker " " = position reached.
Cycle end Display of whether the course of the started cycle has been ended.
Marker " " = cycle end reached.
Measurement ready Display of whether the device is ready for measurement.
Marker " " = measurement-ready.
XTE Display of whether the measured distance has exceeded the XTE trigger
threshold and the XTE output has been set.
Marker " " = XTE trigger actuated.
YTE Display of whether the measured force has exceeded the YTE trigger thresh-
old and the XTE output has been set.
Marker " " = YTE trigger actuated.

For reasons of safety, YTE should always be set above


the expected force value or at the nominal joining force
of the module.

For reasons of safety, XTE should always be above the


expected travel distance or at the nominal travel dis-
tance of the module.

002-518-3e-01.14 Seite 235


Contents

9. Informations

9.1 Putting into Operation Check List


36B

A biref instruction for initial operation of system you can


see in tha operating manual part 1 electomechasnic.

Possible causes/error
Problem Troubleshooting
messages

Operating voltage is missing Check voltage supply

A reasonable screen Device is programmed incorrectly


Consult Kistler Lorch GmbH
display does not appear (Debug mode)
within 20 s after power Hardware error Consult Kistler Lorch GmbH
on. Change blind into the service mask (press F3) and
Contrast setting extremely out of
call up the contrast default setting (operate F3+F4 at
tune
the same time)
Look up in the menu "Doku 
error messages":
"Y-zero point offset" Unload force sensor and repeat the test
Bring the displacement sensor in the basic position
"X-zero point offset"
and repeat the test
No "System-OK"
Recalibrate the displacement sensor and repeat the
"X-calibration incorrect"
test
"Y-calibration incorrect" Recalibrate the force sensor and repeat the test
Select a program before the start of the test, in
"no window is programmed"
which at least one setpoint window is programmed

Input of negative pa- First, set any position unequal to zero (except the
rameters: "Minus sym- Wrong input procedure leading one), then move the cursor on the leading
bol does not function" zero far left and operate the F4 (–).

During the measure- The measurement takes priority


none (in case of need stop the measurement man-
ment: "Service display over all inputs and displays
ually: operate F1 + F2 + ENTER at the same time)
does not react

Wrong Slave address set at DMF-


DMF-P as Fieldbus- P
Make corrections in the menu item "calibrate 
participant does not
Wrong length/structure of data system settings"
reply/react
set at the DMF-P.

Fieldbus-Master re-
In the menu item "calibration  System settings 
ceives strange numeri-
Wrong order of bytes F4: Bus interface settings" switch between "Intel"
cal values from the
and "Motorola" (Byte swap)
DMF-P

Page 236 002-518-3e-01.14


Informations

9.2 Technical Terms-Synonyms


37B

In the course of its development information from the most


diverse sources have been integrated into the measuring
system DMF-P, which have on the one hand resulted in a
coexistence of diverse technical terms, and on the other
hand even in certain contrariness.

The following is a brief overview of equivalent terms and


terms with similar meaning. The term, which should be
preferably used, is displayed in bold print:

Program program-no., set point record no.

set point record (consisting of window-set points and


Program
measuring parameters)

Tolerance Window set point window, set points

Sensor sensor, transmitter

Calibrating taring, adjusting

Measuring Range (at the X-Sensor) measured displacement, characteristic

Emergency Shutdown (SA) monitoring of the starting position (EFU)

Test system test, test cycle

RS232-x (serial interface) COMx

Positioning Parameter (position set) press parameter

Position Sets Position sets define position parameter for positioning

002-518-3e-01.14 Seite 237


Contents

10. Index 38B

A  F 
Absolute tolerance window ........................................... 45  Fast shut down ............................................................ 150 
Actual values ............................................................... 209  Feldbus .......................................................................... 12 
Automatik Betrieb ....................................................... 234  Fieldbus ........................................................... 11, 12, 180 
Average value window .................................................. 71  File output ................................................................... 216 
Force control ............................................................... 162 
B  Force limitation ........................................... 157, 159, 160 
Force sensor ................................................................ 204 
Breakpoint ........................................................... 112, 133  Force window ........................................................ 52, 102 
Breakpoint window ............................................. 112, 144  Front View an Description ............................................. 17 
Fügen........................................................... 169, 170, 191 
Function .......................................................................... 9 
C  Function keys ................................................................ 37 
Calibration ................................................................... 193 
Calibration menu ......................................................... 193  G 
Calibration X‐axis incremental ..................................... 197 
Calibration X‐axis SSl ................................................... 194  Global joining parameter ............................................ 162 
Calibration Y‐axis piezo sensor .................................... 204  Global X‐offset ............................................................ 197 
Channel name .............................................................. 180  Gradient point ............................................................. 133 
Cluster name ............................................................... 180  Gradient window ................................................. 109, 143 
Contents .......................................................................... 2  Graphical editing ......................................................... 172 
Control ........................................................................... 33  Grundstellung .............................................................. 165 
Copying of measuring program ................................... 175 
CSV‐File ........................................................................ 216 
Cursor .................................................................. 134, 220 

help ................................................................................. 5 
D  Histogram .................................................... 222, 223, 225 
Home position ......................................................... 20, 25 
Data transfer ............................................................... 183 
Data transmit ....................................................... 180, 182 
Date ............................................................................. 177 

Deformation compensation ........................................ 163  Idle stroke ..................................................................... 20 
Diagram ....................................................... 132, 134, 155  Impulsdiagramm ........................................................... 35 
Diagram memory ......................................... 211, 216, 220  Incremental displacement sensor ............................... 155 
Diagram range ............................................. 155, 197, 204  IndraDrive ......................................................... 11, 12, 16 
Digital IO ...................................................................... 209  Input of values ............................................................... 40 
Displacement sensor ........................................... 194, 197  Input of values via external keyboard ........................... 41 
Displacement window ........................................... 50, 100  Interfaces ...................................................................... 14 
DMF-P A300 NCF Typ 4734A… ................................ 9  intermediate stop ......................................................... 27 
DMF‐P A300 NCF Type 4734A... .................................... 24  I‐P.M.‐Protocol ............................................................ 216 
Documentation .................................................... 215, 216  IP‐Address ................................................... 180, 181, 183 
Dynamic tolerance window ........................................... 45 

E  Job number ......................................................... 180, 182 
EcoDrive......................................................................... 12  Joining .......................... 9, 19, 20, 157, 159, 162, 163, 185 
End window ............................................................. 76, 85  Joining module ................................................................ 9 
Energy window .................................................... 128, 149  Joining operation long ........................................... 22, 159 
Error messages .................................................... 212, 213  Joining operation short ......................................... 20, 157 
Ethernet ....................................................................... 216  joining processes ........................................................... 27 
Evaluation method absolute tolerance window ............ 45  Joining window ............................................................. 54 
Evaluation method dynamic tolerance window ............ 45 
External keyboard .......................................................... 14 

Kraftregelung .............................................................. 169 

Page 238 002-518-3e-01.14


38BIndex

Kraftsensor Kennwert ................................................. 206  Output .........................................................................216 

L  P 
Language ..................................................................... 177  Parameter ............................................................ 136, 150 
LED .......................................................................... 13, 17  Parameter menu ..........................................................150 
Leerhub ....................................................................... 165  Password ............................................................. 177, 183 
Live‐function ........................................................... 54, 57  Peak window ........................................................... 64, 82 
Localized displacement monitoring ............................ 116  Piezo ............................................................ 204, 206, 209 
Localized force monitoring .......................................... 120  PLC ............................................................. 11, 12, 20, 209 
Logfile .......................................................................... 179  position set ....................................................................24 
Logging ........................................................................ 179  Position set .................... 22, 157, 159, 161, 162, 163, 185 
LPT ............................................................................... 216  Position set 1 .................................................................27 
Position set 4 .................................................................27 
M  Position set transmitting ..............................................185 
Positionssatz .................................. 27, 167, 169, 170, 191 
Manuelle Ansteuerung ........................................ 232, 234  Presentation of measured values ........ 130, 132, 133, 134 
Master sample ............................................................ 197  Printout ........................................................................215 
Mastercheck ............................. 51, 53, 101, 103, 119, 122  Profibus ........................................................................209 
Measured values ......................................................... 130  Programming password ...............................................177 
Measured values table ................................................ 130  Protocol ............................................................... 183, 216 
Measurement ......................................................... 19, 29  Protocol memory ......................................... 211, 216, 219 
Measurement data ..................................................... 183 
Measurement direction ........................................ 30, 156 
Measurement during forward and backward movement

 .................................................................................. 30  Q‐DAS Protocol ............................................................216 
Measurement of force over a range of time ......... 32, 197 
Measurement of force via displacement ...................... 29 
Measurement with compressive and traction forces ... 31 

Measuring cycle standard ............................................. 33  Rear view .......................................................................14 
Measuring program ............................................ 136, 137  Rear View and Description ............................................18 
Measuring range ......................................... 155, 197, 204  Record stepping ...........................................................161 
Menu calibration ......................................................... 193  record switching modes .................................................27 
Menu diagram memory .............................................. 220  Referencing ..................................................................196 
Menu input of set points ............................................. 137  Release name ..............................................................183 
Menu navigation ........................................................... 37  Resolution ....................................................................197 
Menu protocol ............................................................ 211  Rest piezo force sensor ................................................209 
Menu protocol memory .............................................. 219  Restricted area .............................................................123 
Menu service ............................................................... 209  Reverse window ............................................................94 
Menu statistics ............................................................ 222  Rising window ................................................................68 
Menu structure ............................................................. 42  Rückhub .......................................................................165 
Menu system setup 1 .................................................. 177 
Menu system setup 2 .................................................. 180 
Menu system setup 3 .................................................. 183  S 
Menu System setup 4 ................................................. 185  Samba ..........................................................................183 
Menü Systemeinstellungen 4 ...................................... 191  Satzweiterschaltung............................................. 166, 167 
Menüstruktur ................................................................ 43  Screen contrast ............................................................177 
Messbereich Y ............................................................. 206  Self monitoring ..............................................................35 
Messwertdarstellung .................................................. 206  Sensitivity .....................................................................204 
MinPosition ................................................................. 125  Sequence of measuring .................................................33 
Move Betrieb .............................................................. 232  Serial ............................................................................177 
Service .........................................................................209 
N  Servo controller ................................... 11, 12, 20, 22, 185 
Servocontroller ...................................................... 12, 191 
NTP .............................................................................. 181  Set point input .............................................................138 
Set points ............................................................. 137, 215 
O  Setlettime .................................................... 157, 159, 160 
Setzdauer .....................................................................166 
Online‐trigger ...................................................... 110, 112  Snap window ........................................................... 64, 82 
Operation ...................................................................... 37  Soft keys ........................................................................37 

002-518-3e-01.14 Page 239


Contents

Speed of movement ............................................ 159, 160  Window type 0 ........................................ 50, 52, 140, 141 
Speed window ............................................................. 108  Window type 1 .............................................................. 54 
SPS ................................................................................. 12  Window type 10 ............................................................ 82 
SSI ............................................................................ 11, 12  Window type 11 ............................................................ 85 
SSI displacement sensor ...................................... 155, 194  Window type 12 ............................................................ 88 
Start window ........................................................... 79, 88  Window type 14 ............................................................ 94 
Statistics ...................................................... 216, 222, 226  Window type 15 ............................................................ 97 
Status line ...................................................................... 37  Window type 16 .......................................................... 100 
Stauchungskompenstation .......................................... 170  Window type 17 .......................................................... 102 
Stepping of record ....................................... 159, 160, 161  Window type 18 .......................................................... 108 
System ..................................................................... 11, 12  Window type 2 .............................................................. 58 
System password ......................................................... 177  Window type 23 .................................................. 109, 143 
System settings .................................................... 177, 183  Window type 24 .................................................. 112, 144 
System setup 4 ............................................................ 185  Window type 27 .......................................................... 116 
Systemaufbau ................................................................ 12  Window type 28 .......................................................... 120 
Window type 29 .................................................. 123, 148 
T  Window type 3 .............................................................. 61 
Window type 30 .......................................................... 125 
Target positon ............................................................... 26  Window type 31 .......................................................... 127 
Teach‐in ........................... 51, 53, 101, 103, 119, 122, 140  Window type 32 .................................................. 128, 149 
Teach‐In ............................................................... 140, 141  Window type 4 ...................................................... 64, 142 
Test sequence ................................................................ 35  Window type 5 .............................................................. 68 
Testing procedure.......................................................... 35  Window type 6 .............................................................. 71 
Time ............................................................................. 177  Window type 7 .............................................................. 73 
Time server .................................................................. 181  Window type 8 .............................................................. 76 
Tolerance window ............................................... 137, 172  Window type 9 .............................................................. 79 
Tool correction ............................................ 157, 159, 160 
Trace .............................................................. 19, 216, 220 
Transmit‐mode ............................................................ 185 

Transmit‐mode serial .................................................. 185  X‐Offset ....................................................................... 155 
Transmitting position set ..................................... 185, 187  XTE .............................................................................. 150 
Turnback detection...................................................... 156  XTN .............................................................................. 150 

U  Y 
Units ............................................................................ 177  Y‐Offset ....................................................................... 155 
User name ................................................................... 183  YTE ................................................ 110, 112, 143, 144, 150 
YTS ............................................................................... 150 

Verfahrgeschwindigkeit ............................... 160, 165, 166 

Zoom ........................................................................... 220 
W  Zoom mode ................................................................. 134 
Zweibereichsladungsverstärker .................................. 206 
Webserver ........................................................... 180, 181 
Window definition 139, 140, 141, 142, 143, 144, 148, 149 
 

Page 240 002-518-3e-01.14

You might also like