GSE&Tools Technical Liaison Manager Contact: TechRequest via AirbusWorld


Customer Services web site: www.airbus.com
Airbus Central Entity
1 rond point Maurice Bellonte
31707 Blagnac Cedex – France

Tool / Equipment Bulletin No: 340-A3362 TEB Issue No: 4

RECOMMENDED MODIFICATION

EFFECTIVITY: A330-200, A330-300, A340-200, A340-300

PART NUMBER: 98F29103500000

DESIGNATION: UNIT-FILLING,NITROGEN

DESCRIPTION: THIS TOOL IS USED TO PRESSURIZE ACCUMULATORS.

TOOL STATUS: N/A

NOTE: N/A

REASON FOR CHANGE:


GIM updated

MODIFICATION INSTRUCTION:

No impact for tool existing


Periodical test value updated on GIM

HISTORY:
TEB Issue No Change Description Drawing Issue Category
3 CE certification update. K00 recommended
4 GIM updated L00 recommended

Page: 1
Date: 05/02/2017


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

FILL UNIT - NITROGEN


98F29103500000

THIS GSE HAS BEEN DESIGNED IN CONFORMITY WITH


THE DIRECTIVE(S):

PRESSURE EQUIPMENT 2014/68/EU

REACH Compliant

Doc. issue: H FILL UNIT - NITROGEN Page 1 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

Document Validation

Company Department Date

Made by PULS ACTION 08/2010

Checked by PULS ACTION 08/2010

Validated by AIRBUS SEMSD

Record of Revisions

Reference of the
Issue Date Affected Page(s) Reason for revision
document used
F 8 P/N MODIFICATION
Updated template CE
G 11/10/2016 All
directive
Improvement of test
H 24/04/2017 13
periodical

Doc. issue: H FILL UNIT - NITROGEN Page 2 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

Table of Contents

Document Validation ...............................................................................................2


Record of Revisions ................................................................................................2
1 Prerequisites .....................................................................................................4
1.1 General information .......................................................................................4
1.2 Warning and caution .....................................................................................4
2 GSE/Tool setup .................................................................................................6
2.1 Before use.....................................................................................................6
2.2 Customer checklist ........................................................................................6
2.3 Packing checklist ...........................................................................................7
2.4 Zone of use (aircraft location) ........................................................................7
2.5 GSE/Tool description ....................................................................................8
2.6 Personal protective equipment ......................................................................9
2.7 Conditions of use ........................................................................................10
2.8 Assembly procedure....................................................................................11
2.9 GSE/Tool usage during maintenance task ..................................................12
2.10 Disassembly procedure............................................................................12
2.11 Trouble shooting ......................................................................................12
3 Test & Maintenance.........................................................................................13
4 Handling / Storage ..........................................................................................14
5 Removal from service .....................................................................................15
6 End of life.........................................................................................................15
7 Appendices ......................................................................................................16
8 Glossary...........................................................................................................17

Doc. issue: H FILL UNIT - NITROGEN Page 3 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

1 Prerequisites
1.1 General information
All following instructions are only applicable for GSE/Tool P/N 98F29103500000.
This GSE/Tool User Guide must be read in conjunction with the appropriate Aircraft
documentation.
In case of conflicting documents please contact AIRBUS.
Before using or mounting the GSE/Tool, read this GSE/Tool User Guide carefully and
ensure that all content is well understood. Non-compliance with the instructions can
lead to personal injury or material damage and excludes any warranty.

The GSE/Tool is delivered by the manufacturer ready for assembly.


Before GSE/Tool assembly, a visual inspection and crosscheck with tool packing list
(see Chapter 5) shall be performed to ensure there are no missing or damaged parts.
During GSE/Tool life cycle, follow the maintenance intervals set out in the
maintenance instructions (see Chapter 4), except where:
- Visual inspection calls for immediate action;
- Unforeseen conditions necessitate more frequent servicing.

1.2 Warning and caution


A. General
The GSE/Tool P/N 98F29103500000 is designed to meet specific conditions of use
and to fulfil a defined function (described into this user guide). Any other use / action
than that given in this user guide will be under users / operators responsibility (except
in case of specific request coming from Airbus).

Doc. issue: H FILL UNIT - NITROGEN Page 4 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

B. Icons

N/A

C. Safety precautions
Ensure safe working practices when handling the GSE/Tool.
GSE/Tool shall be used only by an authorized and competent person who fully
understands the content of this user guide.
Always follow the procedures described in this user guide and the related Airbus
maintenance tasks.

The user shall ensure that:


x The GSE/Tool is only used for the function it has been designed for, as de-
scribed in this user guide;
x The GSE/Tool is in proper working conditions and that the applicable safety de-
vices are checked for functional reliability;
x Required personal protective equipment (PPE) for the GSE/Tool users are
available and being used;
x Only qualified personnel is in charge of handling, operating, maintaining and re-
pairing the GSE/Tool;
x All attached safety and warning notices will not be removed and are legible.

D. EC Directives

This GSE/Tool is manufactured in accordance with the following European


Directives:
x Pressure Equipment 2014/68/EU
Before use, the user shall ensure that GSE/Tool is in conformity with local legislation
if used outside of the EU.

Doc. issue: H FILL UNIT - NITROGEN Page 5 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

2 GSE/Tool setup
2.1 Before use
x Check that the various parts of the tool are in good condition.
x Check the validity of the last conformity inspection.
x Read the installation instructions given below.
x If applicable, check the firmness of the bearing or mooring points.

2.2 Customer checklist


x Before using the GSE/Tool, be sure that you have:

‫_____܆‬a CE declaration for the GSE/Tool (if applicable),


‫_____܆‬a CE declaration for the standard items of the GSE/Tool (if applicable),
Documents

‫_____܆‬a certificate of conformity,


‫_____܆‬a GSE User Guide,
‫_____܆‬periodical test results (if applicable),
‫_____܆‬AMM, SB, SRM and/or TSM task relevant to the use of the GSE/Tool.

x A manufacturer's plate shall be placed on the GSE/Tool. It must include:

‫_____܆‬the name and country of the manufacturer,


‫_____܆‬the GSE/Tool part and serial numbers,
On GSE/Tool

‫_____܆‬the date of manufacture,


‫_____܆‬the regulatory "CE" marking,
‫_____܆‬the weight of the GSE/Tool,
‫_____܆‬the M.L. of the GSE/Tool,
‫_____܆‬the design issue of the GSE/Tool,
‫_____܆‬if the GSE/Tool is mobile, its maximum speed.

Doc. issue: H FILL UNIT - NITROGEN Page 6 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

2.3 Packing checklist

98 F3500340507

98 F3500340040

Valve/gage assy

Hose

The nitrogen cylinder is not stored in the case, it is taken in the storage place
for that type of consumable.

2.4 Zone of use (aircraft location)

N/A

Doc. issue: H FILL UNIT - NITROGEN Page 7 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

2.5 GSE/Tool description

FILL UNIT - NITROGEN

P/N 98F29103500000

Manufacturer name

Year of construction

The tool allows to fill the nitrogen unit of the


Essential function
A340 aircraft
Secondary function

GSE/Tool weight
9,5 kg
Unit: kg
GSE/Tool dimensions
(Length x Width x Height) 13000 x 240 x 110 mm
Unit: mm
M.L.
150 bars
Unit: bar

Type of energy used by this GSE/Tool Pneumatic

Number of persons required to use this GSE/Tool 2

The tool will be used for a maintenance task in


Working environment
an environment provided for this purpose.

GSE/Tool storage box


P/N 98F29103500507
GSE/Tool storage box dimensions
(Length x Width x Height) 580 x 590 x 600 mm
Unit: mm

Doc. issue: H FILL UNIT - NITROGEN Page 8 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

2.6 Personal protective equipment


Note that PPEs to be used for GSE/Tool handling have to be consistent with the
working environment and associated requirements (some of them can be missing in
this chapter).

Mandatory sight Mandatory hand


protection protection

Mandatory head Mandatory body


protection protection

Mandatory foot
protection

Doc. issue: H FILL UNIT - NITROGEN Page 9 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

2.7 Conditions of use

Condition Details / Limits


Environment of use
External power needed? YES
Operating temperature range

The tool must be used by individuals qualified in aircraft maintenance and trained for
tool manipulation.
A-Training

x Carefully read the safety instructions in whole book before use.


x Carefully read the instructions in the present manual.
x Use the tool only for operations that he’s designed for. Any other utilization is
dangerous and may damage the tool.
x Do not use the tool if one of the operators absorbed drugs or any other sub-
stances that could damage its capacity of reflex and vigilance.
x The operator is responsible of any accident or risk incurred to third parties or
to their properties.

B-Utilization

x Utilization of the tool only in day light or in a good quality artificial light.
x The operator must be found in a comfortable stable position during the ma-
nipulations.
x To be particularly cautious when manipulating in altitude.
x Before any utilization, the operator must check that the tool components do
not present deformations or cuts.
x Before any utilization, the operator must check that the nuts and bolts are cor-
rectly tighten.
x The tool must be in warranty period.

Tool 98 F12303500 000 can be used only for fill the nitrogen unit of the A340 aircraft
. Servicing and maintenance. Any other use will be considered as incorrect.

Doc. issue: H FILL UNIT - NITROGEN Page 10 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

2.8 Assembly procedure


x The valve/gage assy has been previously assembled.
x Isolate the accumulator of the pressurized hydraulic system following the
AMM current procedure.
x Release the pressure from the hydraulic system following the AMM current
procedure.
x Handle and place the bottle with nitrogen out of the aircraft, following current
procedure.
x Connect the valve/gage assy to the nitrogen bottle.

Nitrogen bottle Valve/gage

Hose Lg10m

x Unroll the hose Lg10m taking care to avoid loops that can create one or more
folds.
x Check if the paths of the hoses do not pose any risk of crushing or pinching
who can cause a cut or sectioning of the hose.
x Unscrew the protective cap on the accumulator.
x Check if the valves for pressurizing and purging of the inflation block 98
F29103500 102 are closed.

Hose Lg2.36m
Manometer

Pressuring valve
Purging valve

98 F29103500 102 Hose Lg10m

x Hang the carabiner of the cord-polyamide anti-whipping on the interface of


the fitting provided for this purpose.
x Screw the adapter onto the valve of the accumulator.

Doc. issue: H FILL UNIT - NITROGEN Page 11 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

Cord-polyamide
anti-whipping Carabiner

Hose Lg2.36m
Adapter

x Open the nitrogen bottle and control the outlet pressure, adjust if necessary.
x Slowly open the valve set pressure.
x Fill the accumulator following the AMM current procedure.
x Close the valve set pressure and the nitrogen bottle.
x Drain the hose connected to the accumulator by opening the drain valve.
x Disconnect the adapter from the valve of the accumulator.
x Position the protection cap on the accumulator.
x Drain the hose.
x Remove the carabiner.
x Remove the valve/gage assy from the nitrogen bottle.
x Store in the case.

2.9 GSE/Tool usage during maintenance task


N/A

2.10 Disassembly procedure


Explained on the installation procedure.

2.11 Trouble shooting


In case of problems with standard parts (commercial of the shelf) refer to operating
instruction of standard part manufacturer.

In case of any GSE/Tool issues a communication package (including a description


sheet of TechRequest forms) is available via AirbusWorld.

TechRequest documentation.

If necessary contact your Customer Service Director and/or Field Service; they can
provide you with valuable support in the daily use of TechRequest.

Doc. issue: H FILL UNIT - NITROGEN Page 12 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

3 Test & Maintenance

A. Periodical Test
AIRBUS recommends that following test must be performed every 12 months in
agreement with French legislation:

- Make a leak test at a pressure of 170 bars

If the frequency of the tests under load is more stringent in the country where the tool
is used, AIRBUS recommends that the user comply with the frequency given for the
test under load in the country where the tool is used.

B. Servicing & Maintenance


The servicing and the general maintenance operations must be done before each
use.
The servicing and the maintenance operations of the tool must be done when the tool
is removed or in a rest configuration.
For the tool:
x Examination of conservation condition, operational test.
x The protectors and protective devices are in place and ensure their functions.
x The braking systems are efficient.
For lifting accessories :
x Examination to check for the correct conservation condition of the lifting ac-
cessory.

C. Maintenance Schedule
N/A

D. Specific maintenance
This tool doesn’t need specific maintenance.

Doc. issue: H FILL UNIT - NITROGEN Page 13 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

4 Handling / Storage
A. Handling
Handling of case
The storage case with or without equipment is handled manually, the nitrogen bottle
is not stored in the case.

Handling of parts
All parts are handled manually.

Note : Manufacturer declines all responsibility for consequences of all inappropriate


handling which could cause damage.

B. Storage
Before storing, refer to ‘Packing checklist’ (chapter 2.3) in order to verify the
availability of all items which shall be part of the GSE/Tool P/N 98F29103500000.
When not in use, the tool must be stored in the crate provided for this purpose in a
clean place to avoid damage due to the following risks :
x Chemical: oxidization due to humidity resulting from :
x Rain (water falling directly onto the crate).
x Condensation (by variations in the relative humidity of the air due to tempera-
ture variations).
x Mechanical: surface accident, breakage

Doc. issue: H FILL UNIT - NITROGEN Page 14 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

5 Removal from service


When removing a tool from service, the user must check that:
x No load remains suspended on the tool.
x If the tool is removed, it must be stored in its case.
x For short-term removal from service, if the tool remains on the aircraft, make
sure that it is correctly installed.
x For long-term removal from service, the tool must be removed and stored in
its case.

6 End of life
If the GSE/ Tool is out of order, worn or liable to provoke damages, the user shall
ensure that it is scrapped.

WARNING
To be compliant with regulation 2012/19/EC - Do not dispose Electric
and Electronic Equipment waste and collect them separately

Doc. issue: H FILL UNIT - NITROGEN Page 15 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

7 Appendices

Appendix 1: Periodical test sample

Company in charge of tests

Company: Name : ________________________________________


Address : ________________________________________
Address : ________________________________________

Location: Name : ________________________________________


Address : ________________________________________
Address : ________________________________________

Equipment

Name of manufacturer : ________________________________________


P/N : ________________________________________
Date of manufacture : ________________________________________
M.L. : ________________________________________

Static load tests


M.L. (kg) Proof test factor Test time (min) Load applied

Mean(s) used for test performing: Proof test performed in the presence of: Function:
___________________________ ________________________________ ______________

Result of proof test


We, the undersigned, certify that this working equipment has undergone the proof tests
without failure.
No permanent deformation was observed.

Date: ___ /___ /___ Signature:


Inspectors:

Doc. issue: H FILL UNIT - NITROGEN Page 16 of 17


     
 


P/N:
98F29103500000 GSE/Tool User Guide
ORIGINAL VERSION (ENGLISH LANGUAGE)

8 Glossary
A/C Aircraft
AMM Aircraft Maintenance Manual
E.g. For Example
Fig, Figs Figure, Figures
GSE Ground Support Equipment
Max Maximum
N/A Not Applicable
P/N Part number
M.L. Maximum Limit

Doc. issue: H FILL UNIT - NITROGEN Page 17 of 17


     
 


REFERENCE TEB_340A3362_F29D12060845
Distribution List
ISSUE 4 DATE 02 May 2017

TEB_340A3362_4
Distribution List

ELECTRONIC DISTRIBUTION LIST


MOREIRA EDUARDO [SEOT4]
PINCON BRUNO [SEOT4]
TH92TQ
Schlegel Reinhard [ASOBT]
JACKSON Georgina [SEMSB]
HERAL JEAN MARC [SEMSB]
LAROYE PIERRE [SEMSB]
SOUYRI PIERRE [KVOO]
SAINT-PAUL ALAIN [KIOL]
Rogers Michael [ASOR2A]
CHRISTIAENS ARNAUD [JSO]
LAUNES Franck [for SEMS] (SONOVISION ITEP)
v.rey@dedienne-aero.com
wogse@sonovisiongroup.com
maint.gsetools@airbus.com
programs.gsetools@airbus.com
Repair2@hydro.aero
Tooling-Biberach@hydro.aero
tool.purchase@airbus.com
Rsp.tools@airbus.com
Tool.repair@airbus.com
s.sindou@dedienne-aero.com
t.andrieu@dedienne-aero.com
mdesormeaux@groupedcm.com

© AIRBUS S.A.S. 2017. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.


     
 


REFERENCE TEB_340A3362_F29D12060845
Validation Report
ISSUE 4 DATE 02 May 2017

TEB_340A3362_4
Validation Report

AUTHORS AGREEMENT
Name [Siglum] Date
COUASNARD Julien [for SEM] 05 May 2017 Electronically validated
(SOGECLAIR AEROSPACE SAS)

AUTHORIZATION
Name [Siglum] Date
LAROYE PIERRE [SEMSB] 09 May 2017 Electronically validated

© AIRBUS S.A.S. 2017. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.


     
 