VESDA
• FREEZERS (-45°C TO -12°C)
• High airflows diluting smoke is to install a VESDA-E aspirating VESDA-E detectors provide
• Inaccessible areas for smoke detection (ASD) system, proactive detection in extreme
installation and maintenance of which has the capability to detect low temperature environments
detection systems the incipient (pre combustion) by actively sampling air from a
It may be hard to believe that a fire stage of a fire, drastically reducing protected area via multiple sampling
could occur in a cold store but, business disruption, asset damage holes in a pipe network. The air
they have and they are devastating. and the potential risk to the safety of sample is then transported to an
However, the combustible nature personnel. externally located smoke detector
of the types of materials normally for accurate analysis (Figure 2).
stored in refrigerated environments, THE VESDA ADVANTAGE VESDA filters the sampled air via
a monitored filter thus minimizing
nuisance alarms from dust airborne
particles. Furthermore, nuisance
alarms from condensation
clouds are minimized due to the
inherent sampling of air through
a pipe network that is easily
maintained from outside the freezer
environment.
REFRIGERATED STORAGE • Improved OH&S with
SAMPLING KIT installation, inspection and
maintenance of ASD outside the
With a regular traffic flow in and out refrigerated area, enabling fire
of protected areas, it is inevitable contractors to work in ambient
that warm air will enter, creating conditions the majority of the
condensation. Ice will form on time.
ceiling mounted equipment and • Eliminates the need for costly
structures generally within close access equipment hire for
proximity to the sampling points. service/maintenance
Figure 2: Aggregate Air Sampling Over time the ASD sampling points • Eliminates the need for heat
and pipe within this area may tracing
COLD STORE become blocked causing airflow • Minimizes the need for “Back
INSTALLATION SCENARIOS issues and ultimately an inoperative Flush” systems
smoke detection system. In some • Eliminates the need for
Many industry standards require instances the only solution is to expensive HDPE pipe
the installation of smoke detection remove the iced up section of the
at both the ceiling level and in the ASD pipe network and fit a new pipe.
ceiling void within the cold store.
The Xtralis Refrigerated Storage
Since the VESDA detectors are Sampling Kit provides a robust and
installed outside the protected reliable alternative method of smoke
area, they remain unaffected by the sampling for cold storage facilities,
internal sub-zero temperatures. The in a considerably improved manner
air sample is cumulatively drawn with simplified installation, reduced
from the protected area, raised to maintenance, and an overall lower
a minimum sampling temperature total cost of ownership.
and then transported to the external
detector for accurate analysis Unlike existing practices of
(Figure 3). installing the ASD pipe inside
the protected area, with external Figure 4: Refrigerated Storage Sampling Kit
installation, the Xtralis Refrigerated The sampling kit consists of an
Storage Sampling Kit is less outer and inner parts with ABS
prone to blockage from ice and plastic sampling pipe, suitable
reduces capital, maintenance and for temperatures down to -40°C
installation costs by: penetrating the refrigerated storage
sandwich panel (Figure 4).