Aug.

, 2014 K27 
Products Information
Striving to make products that move you.

Products Information

私 た ち が め ざ す 、も の づ く り 。

ORION PRODUCTS
Precision Air Under the slogan “From general air-conditioning to precision local air-conditioning,”

Processor we offer the “PAP”○R (Precision Air Processor) Series of air-conditioners featuring our
latest proprietary technology – “heat pump balance control.”○R Patented

PAP○ mini Light Duty Series


R PAP○ Temperature Control
R PAP○ Temperature & Humidity
R

Air-cooled Air-cooled Air-cooled


Water-cooled Water-cooled

● Processing air flow 0.7〜4㎥/min


Air-cooled ● Temperature accuracy ±0.1℃
Air-cooled Water-cooled Air-cooled Water-cooled
● Temperature range 18〜30℃
● Processing air flow ● Processing air flow ● Processing air flow ● Processing air flow
● Humidity accuracy ±1%   3〜20㎥/min   3〜40㎥/min   3〜20㎥/min   3〜40㎥/min
● Humidity range 45〜75% ● Temperature accuracy ● Temperature accuracy ● Temperature accuracy ● Temperature accuracy
 ±0.1℃  ±0.1℃  ±0.1℃  ±0.1℃
● Temperature range ● Temperature range ● Temperature range ● Temperature range
 18〜30℃  18〜30℃  18〜30℃  18〜30℃
● Humidity
● Humidity accuracy
accuracy
 ±1%
±1%
● Humidity
● Humidity
range
range
  40〜65%
40〜65%

PAP01B-KJ

PAP01B
PAP10A1
PAP10A1-W
PAP10A1-K

High Accuracy Temperature & Humidity Control Unit


PAP○Type D R PAP○ Type L
R
"Air Processor"
PAP○Temperature & Humidity Control Type, R Series
R

For clean rooms and measurement rooms


Air-cooled Air-cooled
Water-cooled

Air-cooled Water-cooled Air-cooled The circulating type air circuit Thanks to heat pump balance control (by
● Temperature range ● Temperature range
easily enables low to high waste heat utilization) we offer, Ultra Energy
 18〜30℃   8〜18℃ temperature environments. S aving s & Hi gh Ac cu r acy Te mp e r atu re
● Humidity range  ● Cooling capacity
Air-cooled

20〜40%   5.9/7.0kW
Control !
● Processing air flow
● Temperature accuracy ● Temperature accuracy Air-cooled ● Processing air flow 23〜80㎥/min
  4〜15㎥/min
 ±0.1℃  ±2℃ ● Temperature accuracy ● Temperature accuracy ±0.2℃
 ±0.5℃ ● Temperature range 18〜30℃
● Temperature range ● Humidity accuracy ±2%
  5〜35℃、5〜70℃ ● Humidity range 45〜60%
● Humidity accuracy
 ±3%
● Humidity range
 30〜90%

PAP03A-D
PAP05A-L

PAP20A-KR(Temp & Humi,control type)


AP1500MVK-E

Constant Temperature (Constant Humidity) Rooms Energy Saving Dry Room System
Stable supply for a dry air space at dew point temperature of -60℃
ORION proposes construction of a high A strict low humidity environment is required in many fields. (lithium ion
precision air processing system made battery, capacitor production, medical supply production, manufacturing
of localized high quality spaces that can processes or etc.) In answer to the needs of such manufacturing processes,
minimize the utilization of limited energy. ORION brings to the table its original dehumidifying system that offers a
waste-free, energy saving, ultra-low humidity environment.

Pre-cooling + dehumidifier
modular design

1
eco & eco SOLUTION
68% Energy Saving
・CO emission ‒13,940kg-CO /year
2 2

・Operation cost ‒JPY510,000/year

Precision air with energy


saving in Heat Pump
Balance Control ○
R

PAP10A1 PAP10A1-K
Power source capacity and
power consumption comparison
PID heater Completely Precision air conditioning is used in production
control no heater fields demanding precision temperature and
humidity controls.
Electric Most precision air conditioners are equipped
Heater
heater with PID heater control which results in large
Compressor 68% power consumption.
22% 15%
Compressor
Blower fan 10% Blower fan 10% (DC brushless
motor)
Power consumption comparison
        
Max. 80% energy saving
・PID heater control

MODEL : PAP20B1-(F)W
       ・Completely heatless
Yearly running hours:5,000hours
      
※Yearly electric power consumption for PID heater
control is calculated as the rated power Electricity cost : JPY15 /kWh
consumption x 0.85 considering maximum electric
power is not continuously required.

Yearly power consumption comparison 68% energy saving


Reduced CO2 output
13,940kg-CO2 /year
50,000
Power consumption (kWh)

45,000
40,000 Effective energy saving
68%
JPY 510,000/year
35,000
Energy
30,000 50,000 Saving
kWh/year
Reduced CO2
25,000
20,000
15,000 20,500 ※CO2 emission coefficient used is
0.410, the average of 8 power
10,000 16,000 kg-CO2 companies.
13,940
5,000 kWh/year kg-CO2
0 6,560
PID heater Heat Pump Balance kg-CO2
control Control
PID heater Heat Pump Reduced
control Balance Control
CO 2 Output CO2 Output CO2
Effective energy
      ※Actual savings will depend on the usage
saving cost conditions.

        
Effective energy saving cost(estimate)
Difference in
power  :50,000kWh−16,000kWh=34,000kWh
consumptions 
Effective :34,000×JPY15= JPY510,000
energy savings
/year

2
ORION Machinery was the first company in Japan to introduce oil-less rotary vacuum
Vacuum pumps. Low noise and durable, our dry pumps are considered indispensable
for automation and laborsaving devices for a variety of industries, e.g. printing,
Pump semiconductors or etc.
Vaneless Pump

Inverter oil free vacuum pump Oil free vacuum pump


KCE Vacuum Series   KCE Blower Series  KCP Vacuum Series      KCP Blower Series 

Patented Double layer cover construction for low noise Patented High efficiency exhaust construction
First in industry vacuum pump packaged with built-in inverter. Our high efficiency twin rotor gives a high flow rate using less power.

Vacuum application Blower application


Continuous vacuum Continuous vacuum
Max. 80kPa Max. 80kPa
Capacity192 〜 Capacity192 〜
      616m3/h        308m3/h

KCP80-V-01
KCP250-V-01 KCP150-V-01

Vacuum application Blower application


Continuous vacuum Continuous vacuum
Max. 80kPa Max. 100kPa
KCE380A-01 Capacity 79 〜 308m3/h Capacity 79 〜 308m3/h
KCE190A-01
Vane Pump
Standard Type Oscillating Piston Pump Standard Type Standard Type Large Standard Type
KM KYP Series KRF Series KRF Series KRF Series

● Free rotor drive - no ● Oil free ● CE Marking Certified ● CE Marking Certified


side clearance ● Low noise light weight ● Low noise operation, ● Quiet operation - Noise level reduced by 3dB
adjustment necessary Long life   (in-house comparisons)
Continuous vacuum 
Continuous vacuum Ultimate vacuum Continuous vacuum   Continuous vacuum  Max. 60 〜 70 kPa
      Max. 55 kPa     10.7 〜 2.7kPa[abs] Max. 50 〜 75 kPa Max. 60 〜 80 kPa Capacity
Capacity 29L/min(60Hz) Capacity Capacity Capacity 1350 〜 2200L/min(60Hz)
    33 〜 85L/min(60Hz) 75 〜 155L/min(60Hz) 280 〜 685L/min(60Hz) KRF70A-V-01A

KRF04A-V-01 KRF25A-V-01A

KM41A-101-G1 KYP90-101-G1

KRF08A-V-01
KRF40A-V-01A
KRF110A-V-01

Combination Type Combination Type Combination Type Package Direct coupling high vacuum Type High vacuum pump
CBF Series CBX62, CBX62A CBXP Series KHF Series KHA Series

2-cylinder (vacuum and pressure) design allows Low noise design (in-house Continuous operation at Continuous operation at
simultaneous operation of vacuum and pressure for comparisons) Reduced 3 〜 5db ultimate vacuum pressure ultimate vacuum
requirement below 60kPa. Continuous vacuum Ultimate vacuum 8 kPa[abs]
  Max. 60kPa Capacity Ultimate vacuum 8 kPa[abs]
Continuous vacuum Capacity 150 〜 400L/min(60Hz) Capacity
Continuous vacuum  65 〜 400L/min(60Hz)
  Max. 60kPa 1115 〜 2200L/min(60Hz)
Max. 60kPa
Capacity Capacity 1115L/min(60Hz)
280 〜 685L/min(60Hz)

KHF14

KHA400-301-G1
CBXP
CBF4040-VB CBX62-G1 8080B-VV

CBXP8080B-VB KHF20

High vacuum pump Side Channel Blower Silent Box Air Station
Accessories
KHH251 2BH Series KCS Series AS135 Series (BTO)

Continuous operation at Low pressure vacuum / Soundproofing box for vacuum pump Vacuum pump and Water Separator
ultimate vacuum compressor pump blower system box RA41・RA42
(max.1.3 kPa[abs]) 5 to 10 dB reduction in
Blower pressure pump noise Clean Filter
Ultimate vacuum  5.5 〜 32.0 kPa(60Hz) RA-S・RA-D
1.3 kPa[abs] Vacuum pressure
Capacity 179L/min(60Hz) 5.5 〜 30.5 kPa(60Hz)
Capacity 1480 〜 10170L
         /min(60Hz)
Filter (for vacuum)
RA10・RA11
RA22
KCS61A-123
AS135A Oil Separator
RA31・RA32

KHH251-101

2BH1-490-7AH11
KCS70-V-01 AS135W
※ Maximum vacuum may decrease with elevation
of the installation site.
3
eco & eco SOLUTION

57% Energy Saving


・CO2 emission ‒11,470kg-CO2/year
・Operation cost ‒JPY172,100/year

Inverter oil free vacuum


pump for energy saving

KCE380A-01
Energy Savings KCE190A-01
57% saving energy of
power receiving
capacity and
maximum
Previous system power New system
Effective
consumption
10.3 4.4 Increasing 25% of air volume even
kW kW
with one size smaller motor output
Converting energy saving to electricity and
CO2 reduction,
Operation for 8 hours/day, Economy
243days/year. –11,470 kWh/year Automatic control of rotation speed
Electricity cost reduced by CO2 emission reduced by related to the customer loading volume;
50% of electricity for 50% load.
JPY 172,100/year ※1 4.7t CO 2 /year
※2 The amount of CO2 emissions to
※2

Ecology
produce electricity 1kWh =
※1 Based on JPY15/kWh Electricity (kW) x
coefficient 0.41 Noise level 65∼68dB, reducing
        kgCO2
the discomfort to operators
Only KCE190, 380

Energy Saving
KCE KCP KCE KCP
■ Automatic recognition of ■

for reduced electricity cost !
vacuum pump load conditions. MAX.

Great energy savings with the same 84% As seen in the graph below, the KCE brings its speed down
to the capacity of vacuum air being used by the user for
Energy lower energy use.
degree of vacuum and same air flow rate. Saving
※ Saves energy by optimally adjusting the motor speed to match various load changes.
(Patent pending)
100
90 17% Energy Saving KCE Power Consumption Previous model power
consumption
Power consumption(%)

(Eco speed mode )


80
Vacuum air flow (%)

100 100
Potential Savings in
Energy consumption (%)

70
60
MAX. 84% Energy Saving
72% Energy Saving Electric Bill
50
KRF110/60Hz
40 KCE190/60Hz 50 50
30 KCE190/20Hz

20
10 Vacuum
0 0 0 air flow
10 20 30 40 50 60 70 80 8 10 12 14 16 18 20 22
Degree of vacuum (kPa) Time

4
Chiller &
Orion water chillers cool down and/or control the temperature of a heat source by circulating water at a
preset temperature. A refrigeration unit and a water supply system (water tank and pump) are packaged
Dehumidifier in one to easily serve a variety of applications. Dehumidifiers are widely used across a wide spectrum of
industries, e.g. food processing, storage or molding, etc.

Water
Series Features Cooling Capacity Temperature control range tank
DC Inverter chiller DigiEco chiller Middle inverter chiller

● Max. 65% energy Air-cooled


Cooling Capacity
savings possible 2.7 〜 8.7kW
● Temperature control accuracy of built-
Water-cooled Option
± 0.1℃ in
Cooling Capacity
● Compact design 6.0 〜 10.4kW
RKE750A1-V-G1 RKE1500B1-VW-G2

● Max. 65% energy Air-cooled


Cooling Capacity
saving is possible by inverter 7.9 〜 31.4kW
built-
Energy saving chiller

● No trade-off between low load


and high accuracy Water-cooled in
Cooling Capacity
● Safe and reliable design 9.8/10.4kW
RKED2200A-V RKED2200A-VW

● Operates with a maximum Air-cooled


energy savings of 57% Cooling Capacity
● Highly accurate
temperature control
12.2 〜 57/60kW
built-
● Comes with built-in communications Water-cooled Option
in
interface as standard equipment Cooling Capacity
RKE11000A-V RKE11000A-VW
14.1 〜 57/60kW
Large inverter chiller

● Operates with a maximum Air-cooled


energy savings of 57% Cooling Capacity
● Highly accurate 66.0 〜 96kW
built-
Built to
temperature control possible Option
order
● Comes with built-in communications
Water-cooled in
Cooling Capacity
RKE22000A-V interface as standard equipment 70 〜 96kW

● Water tank and pump built into a single Air-cooled


RKS Series built-
Small chiller

package
Unit cooler

Cooling Capacity
● Upper level water tank facilitates cleaning 0.89 〜 1.02kW in
RKS400F1-V
● Built with a heat exchanging coil that inhibits Air-cooled Water-cooled
clogging and can be disassembles when required
RKS750F ● Connections and controls are focused onto the front
Cooling Capacity
0.59/0.62
None
panel for improved ease of use 〜 4.3/4.65kW
RKL Series
Large air-cooled chiller High accuracy water chiller

● Built with a heat exchanging coil


Unit cooler

that inhibits clogging and can be Air-cooled


disassembles when required
● Space saving design for space
Cooling Capacity
7.9/8.5
None
conscious layot.    〜 25.0/27.1kW

RKL-3750-D RKL-7500-D

Water-Cooled
Precision chiller

PEC Series ● Control temperature ± 0.05 ℃ Water-cooled


● Ultimate energy saving with Cooling Capacity
1.0 〜 4.0kW
heat pump balance control built-
(Up to 70 ~ 80% )
Air-cooled Air-Cooled in
● No heater design works with
Cooling Capacity
wide water control ranges 6.2kW
PEC400B1-VW, 900B1-VW

液体温調機器
Fluid temperature control equipment
With free cooling function Light duty chiller Water temperature control unit High accuracy water temperature control unit Fluid temperature control equipment
Eco Hybrid Carry Cool Pel Thermo Thermoelectric cooling unit Chemical Pel Thermo
Cooling capacity 280 〜 920W
Cooling Cooling capacity160/190 Cooling capacity Cooling capacity 250W and more Heating capacity
capacity          〜 500/520W 116/104 600 〜 1,800W
28/33kW 〜 232/220W
LPC1-J
LPC2-J
LPC2

FCC10A LPB3 ETS101/ETS202 Cooling and heating unit Power unit


EKS250-G2
Chilled water supply unit Water soluble coolant
temperature control unit Stored-Ice water cooling unit Dehumidifier
One Way Chiller Coolant Chiller Cooling capacity Dehumidify capacity
Cooling capacity Cooling capacity RT55B
2.5/2.93 1.4/1.6 〜 13.7/15.6 L/h
3.9/4.5 〜 6.1/7.0 L/min 2.5 〜 7.2 kW
〜 4.75/5.01 kW

RT130B RFB1500F RFB3750F1


RKP1500B RKP2200B RCC750B1, RCC1500B1 RFB500F

5
eco & eco SOLUTION

67% Energy Saving


・CO2 emission ‒4,075kg-CO2/year
・Operation cost ‒JPY149,100/year

Save energy with


inverter chiller !
Comparison of energy
savings by chiller load condition RKE3750B-V
Ordinary HB control chiller RKE5500B-V

Previous model (RKE-A)


While power consumption of HB control chiller
Max.
does not change much even when the cooling
Energy consumption (%)

Inverter control
load is low because the compresser continuously
runs at a constant speed, that of ORION inverter
Max. chiller follows the cooling load.
New model

Compared condition
(RKE-B)

Models:・RKL-3750V-C1(HB control)
※HB control…Hot gas Bypass control, which controls
Load(%)
・RKE3750B-V
 the water temperature by passing hot refrigerant
gas in the refrigeration circuit.
( Inverter chiller )
Setting water temp.:20℃
Max. load :11.6kW
Min. load :1.2kW
There is a big differences between max.
Avg. load :6kW
and min. loads. Running hours :10hours/day
Average load may be about half of max. load. (250days/year)
Electricity bill :JPY 15/kWh
Yearly power
consumption comparison
67% energy saving
Power consumption (kWh)

67% Reduced CO2 4,075kg CO2/year


16,000
14,000 Energy
12,000 Saving JPY149,100 saving/year
10,000 Inverter chiller may be the best
8,000 14,800 solution for energy saving if
6,000 kWh/year cooling load greatly fluctuates.
4,000 4,860
2,000 kWh/year Reduced CO2 emission
0 ※ CO2 emission coefficient used is 0.410,
HB control previous chiller Inverter chiller the average of 8 power companies.
(RKL) (RKE)
6,068 1,993 4,075
kg-CO2/year kg-CO2/year kg-CO2/year

HB control inverter Reduced


previous chiller(RKE) CO2 output
chiller (RKL)

        Effective energy savings (estimate)


Difference in power
consumption :14,800kWh−4,860kWh=9,940kWh
Effective energy savings : 9,940×JPY15=
JPY 149,100/year

6
Compressed Orion Clean Air System equipment includes clarification of compressed air and
clean air system oil-water separation of drain. It maintains quality of compressed air supplied to
pneumatic equipment and contributes to clean environment.
PDP

Series Features Air processing capacity Inlet air temperature Suitable air compressors
PDP
RAX light duty series Air-cooled RAX3J 〜 55J
● SUS shell heat exchanger 0.32/0.37 〜 8.9/10.4
● Preventive measure safety design         m3/min PDP Air-cooled 3 〜 55kW
Water-cooled 55kW
● Air intake filter standard equipment Water-cooled RAX55J-W
9.1/10.4 m /min
3

RAX6J RAX37J
PDP
RAX heavy duty series Air-cooled RAX75F 〜 380F-E
● SUS shell heat exchanger
11/13 〜 59/69 m3/min
● Pressure loss less than 0.015MPa Air-cooled 75 〜 380kW
PDP
Water-cooled RAX75F-W Water-cooled
● Easy maintenance and layout 〜 450F-WE 75 〜 450kW
set up 12/14 〜 83/98 m3/min
RAX300F-E RAX240F-W PDP

RAX-SE Air-cooled RAX3J-SE 〜

RAX high temp.


● SUS shell heat exchanger 75F-SE
0.32/0.37 〜 11/13
inlet seriesinlet ● Pressure loss less than 0.015MPa PDP
series m3/min Air-cooled 3 〜 75kW
Refrigerated Air Dryer

PDP
RAX22J-SE RAX75F-SE

RAX-H Air-cooled RAX3.7J-H 〜


● SUS shell heat exchanger 15J-H
RAX-H medium PDP
pressure series ● Working air pressure up to 0.36/0.42 〜 1.3/1.5
PDP Air-cooled
m3/min
1.57MPa 3.7 〜 15kW

PDP
RAX3.7J-H, 15J-H

RAXE-SE ● Max. 65% energy savings Air-cooled


DC inverter control RAXE740B-SE/ PDP
● Safe and dependable design plus 1100B-SE
for high temp. inlet additional functionality PDP Air-cooled
applications 7.4/10.6 m3/min
37 〜 55kW
● Environmental friendly, RoHS
PDP
RAXE740B-SE RAXE1100B-SE

RAXD Air-cooled
● Max. 68% Energy Savings RAXD75A-SE/100A-SE
Digital control for PDP
13.9/15・19.7/22
high temp. inlet ● High Temp. Air. Processing Model m3/min PDP Air-cooled
applications 75・100kW
● Safe and reliable design
PDP
RAXD75A-SE RAXD100A-SE
PDP
RAXE ● Comes with energy saving dew Air-cooled RAXE2300A
point sensor 〜 9800A Air-cooled
Inverter 23 〜 82 m3/min
PDP
120 〜 450kW
control ● Max. 60% energy savings PDP
Water-cooled
● Suitable for low pressure applications Water-cooled RAXE2300A-W 120 〜 1300kW
〜 29600A-W
23 〜 296 m3/min PDP
RAXE4900A RAXE2300A-W

Desiccant Heatless air dryer


type
QSQ light/medium series QSQ large series QSQ-EDC series Energy saving control unit
Super Pack Super Pack Eco Pack
QSQ010A 〜 270B-E QSQ420C-E 〜 2500C-E QSQ420C-EDC 〜 2500C-EDC EDC60A
Inlet air volume 0.1 〜 2.7 m3/min Inlet air volume 4.2 〜 25.0 m3/min Inlet air volume 4.2 〜 25.0 m3/min Dew point display
–80 〜 20℃

QSQ020A QSQ120B-E
QSQ420C-E QSQ1000C-E QSQ420C-EDC QSQ1400C-EDC

Membrane type compressed air dryer Compressed air cooling equipment Compressed air temp control unit Super low temperature air generator Expansion separation compressed air drying equipment
Membrane type Air Dryer Cold Fresh Nano Thermo Compressed air cooling equipment - Spiral cooler Expansion Separation Dryer
MD15 〜 75-AF APX ACU KSC AE7
Outlet dew point–26 〜 –12℃ APX-8A-250 〜 30A-1200 ACU100-MD 〜 ACU2000B KSC200A/450A/750A Air processing capacity
Adjustable output temperature range Temperature control range 16 〜 30℃ Air consumption 740L/min
–30 〜 0℃ 100 〜 1050L/min

MD75-AF
KSC-750A, 200A
ACU2000B

MD25-F APX-15A-500 ACU100-MD

7
eco & eco SOLUTION

52% Energy Saving


・CO2 emission ‒5,186 kg-CO2/year
・Operation cost ‒JPY189,000/year

Energy Savings by
Inverter Air Dryer !

Load factor/day RAXE740B-SE

Standard Air Dryers constantly operate at a 100%


load, resulting in high energy consumption.
Load factor (%)

The inverter air dryer adapts to fluctuations in the


load for potentially lower power consumption.

Air Dryer Yearly Power Consumption Comparison


Power consumption (kWh)

Graph data assuming a part of factory Standard air dryer


RAX90F cumulative value
lines are operating 24 hours
Inverter air dryer
RAXE2300A cumulative value

RAX90F monthly value RAXE2300A monthly value

Below is a chart comparing the actual power


consumption of the inverter air dryer and Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

general air dryer. The inverter air dryer Energy Savings is over 50%. Achieved huge reduction of
achieves great energy saving. CO2 in terms of environmental protection.

Yearly Power Consumption Comparison 52% energy saving


Reduced CO2 5,186 kg CO2/year
JPY 189,000 saving/year
Power consumption (kWh)

Key points in utility room are, understarding of air


Energy consumption and change of pressure, and tractability
of loads.
Saving

Reduced CO emission 2
※ CO2 emission coefficient used is 0.410, the
average of 8 power companies.

kg-CO2/year

kg-CO2/year kg-CO2/year

Reduced CO2
CO2 output CO2 output output

Effective energy savings


Electricity charge : JPY15/kWh
Difference in power consumption :

Effective energy savings :


JPY JPY year

8
Compressed Orion Clean Air System equipment includes clarification of compressed air and
clean air system oil-water separation of drain. It maintains quality of compressed air supplied to
pneumatic equipment and contributes to clean environment.

Compressed clean air system


Super Filter Final Filter Membrane Type Final Filter Medium Pressure Spec. Filter
DSF/LSF/MSF/KSF OFF/OFH series ISO 14644-1 Air Purity Class DFH/LFH/MFH/KFH series
Air processing capacity Air processing capacity 3 (F.S.209D Class 1)fine Air processing capacity
0.35 〜 318.9m3/min 0.26 〜 1.06m3/min particulate removal 5.7 〜 29.0m3/min
Removing water droplet, solid Meets Air Purity Class 3・5 Working pressure 1.57 MPa
particle, oil mist and oil vapor
/odor

Automatic drain release equipment Aftercooler


Drain Trap Drain Trap Air-Cooled Aftercooler Water-Cooled Aftercooler
"Solenoid Type" "Timer Type" "Float Type" "Disc Type" SE TH/THP
"Motor Valve Type" Air processing capacity Air processing capacity
Automatic drain release of 1.0 〜 6.9m3/min 1.7 〜 393m3/min
water and oil drainage Automatic drain release of
water and oil drainage Pre-cooling of compressed air Suitable for pre-cooling of
compressed air in hot ambient
ADE4B ADE300
condition

Compressed air tank


Dew Point Monitor
SUS compressed air tank Air Tank
OAT MST MG MGR
Volume 65 〜 1090L Volume 39 〜 3000L
Simultaneous display of Measurement and digital display
Tank built with SUS304 temperature and humidity of dew point and temperature
or dew point
Dew point display
–30 ~ +20℃ resolution 1/10
Temperature display
–20 ~ +80℃ resolution 1/10
MG40A-P

MGR20

MG40

Filter Type Drain Processing Equipment Compressed air drain processing equipment
Digital Differential Pressure Gauge Differential pressure gauge
Pico-Drain Drain Processing Equipment - Drain Master
DG・DGX・ No electricity required. Meets Water Pollution Control Law
DGE70  Element Life Indicator Lightweight, Space saving, Energy effluent standard.
saving Greatly reduces condensate treatment
Differential pressure detection for Measures difference in pressures Main-processing concentrations
between inlet and outlet of a filter cost.
optimum air filter management below 5mg/L
in a single gauge. OWD/OWC・OWM
Differential pressure display range ODF5
–1.050 〜 1.050MPa Differential pressure display range
0 〜 0.15MPa
OWC75

OWM30

9
construction

Guideline of heat capacity Guideline of heat capacity


Wooden Wooden
construction ㎡ construction 73 ㎡
Concrete Concrete
construction ㎡ construction 96 ㎡

Orion Jet Heaters are widely used for heating/drying


Guideline of heat capacity
applications including
Guideline of heatGuideline
capacity of heat capacity

Industrial
Wooden Wooden Wooden
construction 73 ㎡ construction 165 ㎡ 159 ㎡
concrete cure at construction sites and factory/warehouse heating. They Concrete are㎡
construction
Concrete
construction 96
Concrete
㎡ construction 231 ㎡ 218
construction

eco-friendly with our technoiogies for quiet combustion and enhanced fuel
Heater efficiency.
Guideline of heat capacity
Wooden
construction 159 ㎡
Guideline of heat capacity
Wooden
construction 159 ㎡
Concrete Concrete
construction 218 ㎡ construction 218 ㎡
Jet Heater BRITE IR Heater Guideline of heat capacity Guideline of heat capacity
Wooden Wooden
construction 159 ㎡ construction 60 ㎡
ECO-SILENCE HRR480A-S ROBO-DAN HR120D
Concrete 218 ㎡ HR220A
Concrete
construction construction 83 ㎡
Guideline of heat capacity
■ Heat output 14.1kW Guideline ■ Heat output 24.3kW Guideline of heat capacity
Quiet combustion and high fuel efficiency ■ Operation noise
Wooden of heat capacity
construction
Wooden ㎡
■ Operation noise Wooden
construction
Concrete 60 ㎡ ㎡ construction 106 ㎡
construction
■ Heat output 40.7 〜 24.3kW (50/60Hz) Concrete
construction 83 ㎡ (50/60Hz) Concrete
construction 145 ㎡
 (5 Step combustion) Quiet operation  55/55dB Guideline of heat capacity  66/66dB Guideline of heat capacity
■ Operation noise during ceremony Guideline
Wooden of heat capacity
construction 73 ㎡
Wooden
construction
Guideline of heat capacity
165 ㎡
Wooden Wooden
(50/60Hz) construction
Concrete 106 ㎡ construction 149 ㎡
construction 96 ㎡ Concrete
construction 231 ㎡
 55/55dB Concrete
construction 145 ㎡ Concrete
construction 205 ㎡
Guideline of heat capacity
Guideline of heat capacity Guideline
Wooden of heat capacity Guideline of heat capacity
Wooden
165 ㎡
construction
Wooden 159 ㎡ Wooden
construction
Concrete
Concrete
construction
construction
149
218 ㎡
㎡ construction ㎡
231 ㎡ Concrete
205 ㎡ Concrete ㎡
Automatic rotation
construction construction construction

Left/Right 30° Guideline of heat capacity


Guideline
Wooden of heat capacity㎡
construction
Wooden 159
construction ㎡
Concrete
construction
Concrete 218 ㎡

construction

Guideline of heat capacity Guideline of heat capacity Guideline of heat capacity


Wooden
Wooden
construction ㎡ Wooden
construction ㎡ construction 60 ㎡
Concrete
Concrete
construction ㎡ Concrete
construction ㎡ construction 83 ㎡

Guideline of heat capacity Guideline ofJet Heater


heat Guideline
capacity of heat capacity BRITE IR Heater Guideline of heat capacity
Guideline of heat capacity Guideline of heat capacity
Wooden
Super Swing HRS330
construction 73 ㎡
Wooden
HR330H
Wooden
BRITE Ⅱ construction 165 ㎡
Wooden
construction 73 ㎡ HR330E-L
Wooden
construction 165
construction
㎡ 106 ㎡ Carry-Dan GH150H
construction ㎡
Wooden
Concrete
Concrete
construction 96 ㎡ Concrete
construction
Concrete
231 ㎡
construction 96 ㎡ Concrete
construction 231 ㎡
construction 145㎡ Concrete
construction ㎡

■ Heat output Guideline of heat capacity ■ Heat output Guideline of heat capacity ■ Heat output Guideline of heat capacity ■ Heat output Guideline of heat capacity
38.8 〜 28.1kW Wooden 38.8 〜 28.1kW Wooden 35.0kW Wooden
149 ㎡ 16.7 〜 8.1kW Wooden
73 ㎡
construction 159 ㎡ construction 159 ㎡ construction construction
■ Operation noise Concrete
218 ㎡ ■ Operation noise Concrete
218 ㎡ ■ Operation noise Concrete
construction 205 ㎡ ■ Operation noise Concrete
construction 96 ㎡
construction construction
(50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz)
 62/62dB Guideline of heat capacity  62/62dB Guideline of heat capacity  65/65dB Guideline of heat capacity  48/50dB Guideline of heat capacity
Wooden Wooden
Wooden
construction 159 ㎡ Wooden
159 ㎡ construction ㎡ construction 159 ㎡
construction
Concrete ㎡ Concrete
Concrete
construction 218 ㎡ Concrete
construction 218 ㎡ construction
Quiet
construction 218 ㎡

Guideline of heat capacity Guideline of heat capacity Guideline of heat capacity


Wooden
Wooden
construction 60 ㎡
Wooden
construction 60 ㎡ construction 159 ㎡
Concrete
construction 83 ㎡ Concrete
construction 83 ㎡
Concrete
construction 218 ㎡

Guideline of heat capacity Guideline of heat capacity Guideline of heat capacity


Wooden Wooden Wooden
construction 106 ㎡ construction 106 ㎡ construction 60 ㎡
Concrete
Concrete
construction 145 ㎡ Concrete
construction 145 ㎡ construction 83 ㎡

Guideline of heat capacity Guideline of heat capacity Guideline of heat capacity


Wooden Wooden
construction 149 ㎡
Wooden
construction 149 ㎡ construction 106 ㎡
Concrete
Concrete
construction 205 ㎡ Concrete
construction 205 ㎡ construction 145 ㎡
Jet Heater Portable/Blow Heater
HPE80A HPE150A Guideline HPE250 E HPE310-L Wooden
Guideline of heat capacity
Guideline of heat capacity
Wooden E Seriesof heat capacity
Series E Series
construction 149 ㎡
Wooden
construction ㎡ construction ㎡
Concrete
construction 205 ㎡
Concrete ㎡ Concrete ㎡
construction construction
■ Heat output
■ Heat output ■ Heat output 17.0kW  High 29.2kW Low 20.0kW ■ Heat output 35.0kW
Guideline of heat capacity
Wooden
High 8.8kW Low 6.3kW ■ Operation noise ■ Operation noise ■ Operation noise construction ㎡
Concrete ㎡
■ Operation noise (50/60Hz) 70/70dB (50/60Hz) 68/69dB (50/60Hz) 68/69dBconstruction
(50/60Hz) 58/54dB
2 stage combustion
Quiet
● High/Low 2 stage combustion
● Equipped with rotary gas burner

Jet Heater Portable/Blow Heater Jet Heater HS Heat Exchange/Blow Heater


HPE370 E Series HPS830A HS290-L
■ Heat output
 High 43.0kW Low 32.0kW ■ Heat output 97.2kW ■ Heat output 33.3kW Heat exchanger

■ Operation noise ■ Operation noise ■ Operation noise


(50/60Hz) 74/78dB
Clean exhaust

(50/60Hz) 70/71dB (50/60Hz) 72/74dB

2 stage combustion
2 step air flow
Delivers clean
hot air by duct mounting.

10
Temperature Orion products for environmental testing have demonstrated their reliability in applications for leading-
Test Chamber edge industries such as semiconductors, LCDs and quartz oscillator requiring highly accurate
temperature/humidity controls and providing severe temperature conditions for electronic devices testing.

ESV Compact Type Vertical Test Chamber Turn Table Type Thermostatic Chamber Thermostaticl environmental test chamber
   BTO EST-S EST-H Thermal Stream BTO

Suitable for reliability test Energy saving no heater low temp. test chamber Temperature and humidity control test
of electronic devices chamber with a vertical slide door.
● Cost effective, turn-table type ● New thermostatic test chamber
thermostatic chamber with improved workability ● Test temperature
range between
–40 and 100℃
while even with the
slide door open half.
● Temperature control
range : 
–40℃〜+ 100℃

In-line temperature test chamber In-line micro device temperature test chamber In-line curing oven
   Single temp. range BTO    Multi temp. range   BTO (Peltier Method) BTO                BTO

● Provides temperature characteristic ● Multi chambers with different Suitable for micro device high/low temperature test ● Rack conveyor or multi-carrier
test in line for automobile parts and temperatures can be installed to meet
● In-line temperature test chamber for small
allows plenty of work processing.
crystal oscillator ICHI VIETNAM
various application requirements.
devices ● Suitable for adhesive curing, etc.
● Suitable for characteristic test of  Processes large amounts of work pieces
● Thermal testing from –40 to +125℃ Office address : Lot C15 / D21 Cau Giay New Urban Area, Dich Vong Hau, Cau Giay,
crystal oscillator and sensor at
● Fully automated thermal inspection
compared with batch type.
  possible even when the loading/ for labor saving
each temperature.
Hanoi
unloading access is open.
Hotline: 0986.798.906/0986.226.386
E-mail: sales@ichivina.com.vn /namdd@ichivina.com.vn
Website: www.ichivina.com.vn

Food Orion Food Equipment contributes to cooking system innovation and deveiopment of the
Equipment food culture. Rapid cooling equipment is indispensable for safe food production.

Dryman Pico Blast Blast Chiller & Freezer Chilledman Carry


● Food dryer without heater ● Rapid cooling unit ● Rapid cooling and freezer ● Most fresh food stocker
● Precise and wide range ● Compact to fit into ● Washable inner walls without air flow
temperature settings an existing kitchen ● Hard to dry out without plastic
wrapping

RDF350A RPB5 RB202A RV350G-G1

For Orders and Inquiries:

International 246, Kotaka, Suzaka-shi, Nagano-ken, 382-8502 Japan


Group TEL +81-(0)26-246-5664 FAX +81-(0)26-246-6753
Email: kokusai@orionkikai.co.jp
Head Office 246, Kotaka, Suzaka-shi, Nagano-ken, 382-8502 Japan
& Factory  TEL +81-(0)26-245-1230 FAX +81-(0)26-245-5424
URL: http://www.orionkikai.co.jp

This catalogue contains product specifications as of Aug., 2014.


● Actual product colors may vary slightly from catalogue.
● The structure or specifications of products contained in this catalogue □
S No.0850 140425
  are subject to change without prior notice.