You are on page 1of 2

OTDR report

Job info
Job ID : Reason :
Contractor : NOVKER Operator A :
Customer : Operator B :
Test date : 23-Oct-19 (3:32:24 PM GMT+7:00) File : pjn trk bsb c1-1310.sor

Cable info
Fiber ID : Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 0.771 dB Avg. splice loss : ---
Span length : 2.3358 km Max. splice loss : ---
Average loss : 0.330 dB/km Span ORL : <35.58 dB

OTDR trace

dB

25.00

20.001

15.00
2

10.00

5.00

0.00
500 1000 1500 2000 2500 3000 3500 4000 m

Signature : _________________________ Date : 12-Dec-19


EXFO E. O. Engineering Inc. Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 0.000


Fiber Section (2.3358 km) 0.771 0.330 0.771
2 2.3358 Reflective Fault 0.000 46.2 0.771

Marker info
A : 0.0000 km, 7.726 dB B : 0.0000 km, 7.726 dB
a : 0.0000 km, 7.726 dB b : 0.0000 km, 7.726 dB
A to B distance : 0.0000 km, 0.000 dB A to B ORL : *****
3-pt. reflectance : ***** A to B LSA att. : -0.000 dB/km
4-pt. Ev. loss : 0.000 dB

Test and cable setup


Wavelength : 1310 nm (SM-9µm) Acq. time : 10 s
Filename : pjn trk bsb c1-1310.sor Pulse width : 160 ns
Hardware : Helix factor : 0.00 %
Serial number : Splice loss threshold : 0.100 dB
Software : N/A Reflectance threshold : -40.0 dB
Range : 4.1825 km End-of-fiber threshold : 10.000 dB
IOR : 1.468000
RBS : -80.00

Signature : _________________________ Date : 12-Dec-19


EXFO E. O. Engineering Inc. Page 2 / 2