You are on page 1of 1

"

•••••
.. :
:; ■■Jill
.M:1\GNEl:lC.:,PA.BT::fCJJE/INrsieE'CTION
r----�· ___;·_;· __,.�--�
CLIENT
AGOCO
Engineering
CONTRACTOR

FERROSTAAL
LOCATION
'

SARIR OILFIELD
..:...c ·
· - '-----i--'-:: ·�· --"•· -�· -· _:_:_• -� REPORT N2. 59

SHEET 1 OF 1

Taknia Construction Dept. ECD462/2010 GC-4


REQUEST NQ. J-22
(E.C.D}

MATERIAL WELD PROCESS - EQUIPMENT .. CONTACT SPACING


Carbon Steel GTAW Permanent Magnet 4 ~5 cm.
SIZE THICKNESS TYPE CONTRAST PAINT
l"dia. 3.38MM Magnaflux WCP-2 Magnaflux
SCHEDULE PREPARATION SURFACE COND'N. MAGNETIC INK
SCH40 Fillet Weld As welded 7HF Magnaflux
LINE IDENTIFICATION AREA
1-NG-30021.1-Al , GC-4
DRAWING N2. ACCEPTANCE STD. WELD CLASS
ANSI 831.3 10%
SPOOL/ ITEM NQ. OPERATOR DATE
N/A JV,RE,AE 03 AUGUST 2020
WELD WLDR WELD
DIA. SCH. TYPE INTERPRETATION RESULT
IDENT. N!! AREA·
SW70 1" 40 FOl 100% PIPE r NSD A
SW92 1" 40 FOl 100% PIPE NSD A
.... ,

*NOTHING FOLLOWS*

- ---
.,,,----- - I '
.--------------
I

------�

COMMENT/ SKETCH

!i !

COMPANY ' "r·· ,-=�:
·.•. .,1 __ " .; 11."•1.A-
' n: -L:.:.:·'
, I AGOCO AGOCO-Sarir
N A ME Ab�ul Hamed S,
DESIGNATION ;KC.Q,-D�pt.fCaprdinator
SIGNATURE
DATE (}$ AUGUST 2020 '( o\,AuGusT 2020

LEGEND:
NSD - NO SIGNIFICANT DEFECT PG- POROSITY LF- LACK OF FUSION A-ACCEPTED

NHSD- NO REJECTABLE SIGNIFICANT DEFECT CK - CRACK sue - UNDERCUT R-REPAIR