You are on page 1of 7

0.1 0.2 0.3 0.3.1 0.4 0.5 0.5.7 0.6 0.7 1 2 3 3.8 4 4.7 4.

8 5

TF 619.80 TF 619.80
TF 620.30

2
C-
k WP- k.1 WP- k.2 k
WP- k.3

TF 620.80 TF 620.80
k/0.7 GB-1 GB-1
TF 620.80

2
C-
j WP- j.1 WP- j.2

TF 620.80 TF 620.30

j/0.3 GB-1 GB-1 j/0.6


h TF 620.80

h/0.1 h/0.2
g
DP.

GB-5
33"

TF 620.30
TF 621.30 TF 620.30

f TF 621.30

TF 620.80 TF 621.30

SW-O.7
2

2
C-

C-

C-

C-
e

2
C-
f/0.4 f/3.8
f/0.5 f/4.8
d d
e/0.2
c
SW-0.1
GB-2

b.8
GB-3

60" DP.
36" DP.
4
b.8-/0.5 b.8-/0.5.7
b.8-/0.3.1

2
C-

C-
2
b b

C-
SW-b TF 620.80

TF 620.80 TF 620.80 TF 620.80 TF 620.80

a 5 FF 619.80 a
1 3
24" DP. TF 619.56 TF 618.33 24" DP. 11
2 30" DP. FF 619.80
TF 620.80
A TF 620.80 TF 620.80 A

2
2

C-
C-

10
C-2 C-2 SW-a.1
a/0.1 a/0.2 a/0.3.1 a/0.5.7
B TF 620.80
B
TF 617.10
6
7 9

C C

D D
8

E E

E.1

E.3

4 4.8 5

WALL & COLUMN LAYOUT GRADE 60 A615 MILLENNIUM


PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS.
NO. TO FOR DATE
PA-12 OTAY RANCH
F F MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/27/21
1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER

0.4 0.5 0.5.7 0.6 0.7 1 2 3 ARCHT.

ENGR. VCA STRUCTURAL


TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

S6.1.1S,
WORK DRAWINGS S6.1.2S, S6.1.3S
TOGETHER DWT CHK 12/17/21 R-3H
4.8 5 5.5 5.7 5.8 6 7 7.2 7.3 8 8.1 8.5 8.8 9 9.7 9.8 10 10.7 10.8 11 11.5 11.8 12 12.8 13 14

11.9

TF 619.80

2
C-
k WP- k.3 WP- k.4 WP- k.5 WP- k.6 k
TF 618.20

GB-1 GB-1 GB-1 GB-1 GB-1 k/9.7

h
TF 618.20 TF 618.20

WP- g.1 WP- g.2 g

TF 618.70
GB-1 GB-1

TF 620.30 TF 620.30
TF 619.30 TF 619.30

GB-6
f
TF 619.30

SW-9.8
TF 618.70

1
2

C-
C-

C-

C-
e C-2 TF 618.70

f/8.5
f/5.8 f/7.2 f/8.1 f/8.8

2
C-
d d

d/10.7 c

SW-11.9

GB-7
TF 618.70
TF 619.30
TF 619.30 25

1
C-
b.8
TF 618.70
b.8/8.5

GB-11
TF 618.20 24

SW-8
TF 618.70

GB-4 56" DP. TF 616.96


TF 618.70
b 36" DP. TF 615.73
b
56" DP.
GB-6 TF 618.20
TF 614.50
a FF 619.80 a
30" DP.
FF 619.80 FF 619.80 12 24" DP. 14 42" DP. 18
TF 618.80 TF 618.80
A 18" DP. 13 18" DP. TF 614.50 A
TF 614.50 C-2
SW-a.1 SW-a.2

B
a/11.9 B
15 TF 614.50
17 19 TF 615.67

TF 615.
TF 616.84

C C

67
TF 614.50

16 TF 618.00

D D

2a
TF 618.00

C-
E E

E.1

E.3

11.8 12 13 14

WALL & COLUMN LAYOUT GRADE 60 A615 MILLENNIUM


PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS. PA-12 OTAY RANCH
F F NO. TO FOR DATE

MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/27/21
1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER
4.8 5 5.5 5.7 5.8 6 7 8 9 10 10.8 11
ARCHT.

ENGR. VCA STRUCTURAL


TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

S6.1.1S,
WORK DRAWINGS S6.1.2S, S6.1.3S
TOGETHER DWT CHK 12/17/21 R-3I
13 14 14.8 15 16 17 18 18.8 19

k k

h
TF 618.20

2
C-
g

g/14.8

e
d/17
TF 618.00
TF 618.00

1
1
2

C-
C-
C-

d d
TF 616.80
TF 616.80
d/14.8 d/15

1
C-
GB-1 c

c/19
b.8

b TF 618.00 TF 618.50 b
TF 617.30 TF 617.30
GB-8

a 1 a

1
2

C-

C-

C-
C-

18
b/14.8
SW-15

A TF 614.50 A
b/16 b/17 b/18

B TF 616.80 B
17 19 TF 615.67

SW-19
TF 614.50
23
TF 615.

TF 616.84

C C
67

TF 618.00 GB-9

GB-10
TF 614.50

16
36" DP.
D D
20

SW-19
TF 618.00 TF 616.80 TF 616.80
TF 618.00 TF 618.00
2a
C-

TF 616.80
C-2 SW-a.3 21

D+/14+ D+/14.8
36" DP.

TF 616.80

36" DP.
E E
TF 618.30

TF 619.80

E.1
TF 621.30

22 TF 622.80
E.3
TF 624.30

TF 625.80

TF 625.80

WALL & COLUMN LAYOUT GRADE 60 A615 MILLENNIUM


PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS. PA-12 OTAY RANCH
F F NO. TO FOR DATE

MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/27/21
1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER
13 14
ARCHT.

ENGR. VCA STRUCTURAL


TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

S6.1.1S,
WORK DRAWINGS S6.1.2S, S6.1.3S
TOGETHER DWT CHK 12/17/21 R-3J
f

d
e
b

e
d

f
0.4 0.5

TYP. U.N.O.

2 1/2" CLR.@ END OF WALL

7
0.
SW-0.1 b SW-b SW-O.7

14" THICK WALL 1 1/2" CLR.@ EACH SIDE 14" THICK WALL 18" THICK WALL
0.1/b+ 0.1/e b+/0.4- b+/0.4+ 0.7/g- 0.7/b.8
646.02 UPPER PODIUM 646.02 UPPER PODIUM 646.02 UPPER PODIUM

644.85 644.85 644.85

TIES @4" O.C. TIES @4" O.C. TIES @4" O.C.


V3 12#7 24-01
73#4 4A1 TIES@4" O.C. V3 12#7 24-01
73#4 4A1 TIES@4" O.C.

V3 12#7 24-01 V3 12#7 24-07


73#4 4A1 TIES@4" O.C. V3 12#7 24-01 74#4 4A2 TIES@4" O.C. V3 12#7 24-07
73#4 4A1 TIES@4" O.C. 74#4 4A2 TIES@4" O.C.

TF 620.80 TF 620.80 TF 620.80 TF 620.80 TF 620.30 TF 620.30

1ST TIE 2" 1ST TIES @ 2" 1ST TIES @ 2"

SW-0.1 SW-b SW-O.7

22'-0" 19'-6" 23'-0"

8
b.

b.
d
g

c
b
4.7 4.8 5 5.5 5.7

a
1
8.

8
9.
8

SW-a.1 SW-8 SW-9.8

14" THICK WALL 12" THICK WALL 20" THICK WALL

a/4.8 a/5.7 8/b.8 8/b+ 9.8/g 9.8/b.8


646.02 UPPER PODIUM 634.00 LOWER PODIUM 646.02 UPPER PODIUM

644.85 644.85

TIES @6" O.C.

V3 8#5 14-08
34#4 4A4 TIES@6" O.C.+ ADDED V3 8#5 14-08
34#4 4A4 TIES@6" O.C.+ ADDED

TIES @4" O.C. 14 TIES @4" O.C. TIES @4" O.C. LOWER PODIUM
TF 619.30 TF 619.30

1ST TIES @ 2"

V3 12#7 24-01 V3 12#6 26-08


SW-8
73#4 4A1 TIES@4" O.C. V3 12#7 24-01 81#4 4A3 TIES@4" O.C. V3 12#6 26-08
73#4 4A1 TIES@4" O.C. 9'-6" 81#4 4A3 TIES@4" O.C.

TF 619.80 TF 619.80 TF 618.20 TF 618.20

1ST TIES @ 2" 1ST TIES @ 2"

SW-a.1 SW-9.8

30'-0" 24'-0"

GRADE 60 A615 MILLENNIUM


PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS.
NO. TO FOR DATE
PA-12 OTAY RANCH
MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/06/21 1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER

SHEAR WALL JAMB COLUMNS ARCHT.

ENGR. VCA STRUCTURAL


SW-0.1, SW-b, SW-0.7, SW-a.1, SW-8 & SW-9.8 TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

SC-5.0,
WORK DRAWINGS 5.1 & 5.2 TOGETHER DWT CHK 12/17/21 R-3
8
b.
d

b
TYP. U.N.O.

D
C
16 17
2 1/2" CLR.@ END OF WALL

9
11.
8
SW-11.9

11.
1 1/2" CLR.@ EACH SIDE
D
20" THICK WALL
11.9/f 11.9/b+
646.02 UPPER PODIUM SW-a.3
SW-19
644.85

18" THICK WALL 14" THICK WALL


D+/16 D+/17- 19/B+ 19/C- 19/D 19/D+ LOWER PODIUM
634.00 LOWER PODIUM 634.00

TIES @6" O.C. V3 12#7 17-02 TIES @6" O.C.


40#4 4A9 TIES@6" O.C.+ ADDED V3 12#7 17-02
V3 10#7 17-02
TIES @4" O.C. LOWER PODIUM 40#4 4A8 TIES@6" O.C.+ ADDED V3 10#7 17-02 40#4 4A9 TIES@6" O.C.+ ADDED
40#4 4A8 TIES@6" O.C.+ ADDED
V3 12#7 17-02
V3 10#7 17-02 40#4 4A9 TIES@6" O.C.+ ADDED
14 TIES @4" O.C. 40#4 4A10 TIES@6" O.C.+ ADDED 14 TIES @4" O.C.

TF 616.80 TF 616.80 TF 616.80 TF 616.80

V3 12#6 26-02
79#4 4A3 TIES@4" O.C. 1ST TIES @ 2" 1ST TIES @ 2"
V3 12#6 30-04
92#4 4A3 TIES@4" O.C.
SW-a.3 SW-19

TF 618.70 TF 618.70 20'-0" 15'-0"


1ST TIE @ 2" TF 616.96

TF 615.73

TF 614.50
SW-11.9

22'-0"

9.7 9.8 10

SW-a.2

a
b

B
A

D
C
14" THICK WALL
a/9.7- a/10+
646.02 UPPER PODIUM

644.85

15
SW-15

12" THICK WALL


TIES @4" O.C. 15/b 15/C-
LOWER PODIUM 634.00 LOWER PODIUM

V3 8#6 16-00
38#4 4A4 TIES@6" O.C.+ ADDED TIES @6" O.C.
2x81#4 4A7 2 HAIRPINS@4" O.C.
V3 18#6 26-08 2x81#4 4A7 2 HAIRPINS@4" O.C.
V3 8#6 16-00
81#4 4A5 TIES@4" O.C. V3 18#6 26-08
38#4 4A4 TIES@6" O.C.+ ADDED
81#4 4A5 TIES@4" O.C.

14 TIES @4" O.C.

TF 618.20 TF 618.20 TF 618.00 TF 618.00

1ST TIES @ 2" 1ST TIES @ 2"

SW-a.2 SW-15

30'-0" 15'-2" GRADE 60 A615 MILLENNIUM


PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS.
NO. TO FOR DATE
PA-12 OTAY RANCH
MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/06/21 1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER

SHEAR WALL JAMB COLUMNS ARCHT.

ENGR. VCA STRUCTURAL


SW-11.9, SW-15, SW-a.3, SW-a.2 & SW-19 TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

SC-5.0,
WORK DRAWINGS 5.1 & 5.2 TOGETHER DWT CHK 12/17/21 R-3.1
L85 = 12 BAR COL. L85 = 12 BAR COL. L85 = 12 BAR COL.

4'-0" 4'-0" 4'-0"

D D1 D D1 D D1

1'-8"
1'-2"

1'-6"
F F F

A A A

G G G
B1 B3 B2 B5 B4
B1 B3 B2 B5 B4 B
1'1/2" CLR. B1 B3 B2 B5 B4 B
1'1/2" CLR.
B
1'1/2" CLR.
E E1 E E1 E E1

C C C

1'1/2" CLR. EACH SIDE 1'1/2" CLR. EACH SIDE 4A3 1'1/2" CLR. EACH SIDE
4A1 4A2
TYP. U.N.O. TYP. U.N.O. TYP. U.N.O.

2'1/2" CLR.@ END OF WALL 2'1/2" CLR.@ END OF WALL 2'1/2" CLR.@ END OF WALL

L88 = 18 BAR COL.


L92 = 8 BAR COL.

3'-6" 4'0"

MK4A5 @4" O.C.


E
1'-0"

1'2"
B E F R C
G
G
C
A
C3 C1 C C2 B2 B4 B3 B6 B5 B B1
2'1/2" CLR.@ END OF WALL TYP. U.N.O.
A
D C2 C1
D
F

4A4 1'1/2" CLR. EACH SIDE 4A5 1'1/2" CLR. EACH SIDE TYP. U.N.O.
2 - MK4A7 HAIRPINS@4" O.C.
ALT. HOOK
TYP. U.N.O.

2'1/2" CLR.@ END OF WALL

L82 = 10 BAR COL. L85 = 12 BAR COL. L82 = 10 BAR COL.

3'-0"
3'9" 2'4"

E H D D1 E H
1'-2"
1'6"

1'2"
C F C

B2 B4 B3 B B1 G B2 B4 B3 B B1
B1 B3 B2 B5 B4
A
B
1'1/2" CLR. A
F E E1 F

D C D

4A8 1'1/2" CLR. EACH SIDE 1'1/2" CLR. EACH SIDE 4A10 1'1/2" CLR. EACH SIDE
4A9
TYP. U.N.O. TYP. U.N.O. TYP. U.N.O.

2'1/2" CLR.@ END OF WALL 2'1/2" CLR.@ END OF WALL 2'1/2" CLR.@ END OF WALL

GRADE 60 A615 MILLENNIUM


PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS.
NO. TO FOR DATE
PA-12 OTAY RANCH
MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/06/21 1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER

SHEAR WALL JAMB COLUMNS ARCHT.

ENGR. VCA STRUCTURAL


UNI-TIE BEND TYPE TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

SC-5.0,
WORK DRAWINGS 5.1 & 5.2 TOGETHER DWT CHK 12/17/21 R-3B
THEO BAR BND BENDING DIMENSIONS THEO BAR BND BENDING DIMENSIONS
QTY SIZE LENGTH WGT EP MARK V TYP CD A B C D E F/R G H J K O QTY SIZE LENGTH WGT EP MARK V TYP CD A B C D E F/R G H J K O

171 4 20-07 2351 4A3 L85 0-042 1-05 3-09 1-08 0-112 2-041 0-042 438 4 17-07 5144 4A1 L85 0-042 0-11 3-09 1-08 0-112 2-041 0-042

1-05 1-08 0-112 0-11 1-08 0-112

1-05 0-11

1-05 0-11

1-05 0-11

1-05 0-11

76 4 12-09 647 4A4 L92 0-042 2-03 0-09 1-03 2-03 3-03 0-042 148 4 19-07 1936 4A2 L85 0-042 1-03 3-09 1-08 0-112 2-041 0-042

0-09 1-03 1-08 0-112

0-09 1-03

0-09 1-03

162 4 18-02 1966 4A5 L88 0-042 0-11 0-082 3-09 1-012 2-051 0-042 1-03

0-11 0-082 1-063 1-03

0-11 0-082 162 4 20-07 2228 4A3 L85 0-042 1-05 3-09 1-08 0-112 2-041 0-042

0-11 1-05 1-08 0-112

0-11 1-05

0-11 1-05

0-11 1-05

324 4 1-06 325 4A7 T9 0-042 0-083 0-042 1-05

80 4 17-02 917 4A8 L82 0-042 1-03 1-003 3-06 1-102 1-003 0-042 2-081 68 4 12-09 579 4A4 L92 0-042 2-03 0-09 1-03 2-03 3-03 0-042

1-03 0-09

1-03 0-09

1-03 0-09

1-03 24 7 24-07 1206

120 4 14-09 1182 4A9 L85 0-042 0-11 2-09 1-03 0-09 1-09 0-042 72 7 24-01 3544

0-11 1-03 0-09 24 6 26-08 961

0-11 16 5 14-08 245

0-11
R-3

0-11

0-11

40 4 11-07 310 4A10 L82 0-042 0-11 0-082 2-01 1-02 0-082 0-042 1-072

0-11

0-11

0-11

0-11

66 7 17-02 2316

12 6 30-04 547

36 6 26-08 1442

12 6 26-02 472

16 6 16-00 385
GRADE 60 A615 MILLENNIUM
R-3.1
PREFIX REINFORCING
BAR LIST PRINT RECORD
NOS.
NO. TO FOR DATE
PA-12 OTAY RANCH
MK REVISION DATE
APARTMENTS
FOR SUBMITTAL 08/06/21 1445 TOWN CENTER DRIVE
FOR CONSTRUCTION 12/17/21 CHULA VISTA
CUSTOMER

SHEAR WALL JAMB COLUMNS ARCHT.

ENGR. VCA STRUCTURAL


SW-0.1, SW-b, SW-0.7, SW-a.1, SW-8 & SW-9.8 TO BE USED WITH STRUCTURAL DRAWINGS
DRAWN CHECKED DATE CONTR.NO. DWG. NO.

SC-5.0,
WORK DRAWINGS 5.1 & 5.2 TOGETHER DWT CHK 12/17/21 R-3A

You might also like