Member Schedule

Mark Member Size MAX. SPAN MAX. CANTILEVER


3FB1 410UB54 7,400

3FB2 240x45 MGP10 1,400


D D
3FB3 2 No. 290x45 F17 KDHW 3,000

R1 3FB4 310UB40 6,300

G
2
L2

SC
4FB1 2 No. 290x45 MGP10 3,000
G
4FB2 240x45 MGP10 1,000

3FB1 4FB3 200PFC + 100x10 EA 3,300

2
SC

SC

SC
G
4FB4 250UB31 2,000 700
FJ1

L3
L1 240x45 MGP10 1,000

L2
UNIT 3 LINE OF UPPER 290x45 MGP10 2,000

L2
FLOOR (TYP.)
L3 300PFC + 100x8 EA 3,800

L4 300PFC + 100x8 EA 4,600

2
SC

3FB4
SHADE
DENOTES LOAD
DS DOUBLE 90x45 MGP10 -
BEARING WALL P1 100x100 CYPRESS -

L2
D
(TYP.)
P2 2 No. 90x45 F17 KDHW -

C1 89x89x5 SHS -
3FB3

DS

P2

P2
SC1/SC2 89x89x5 SHS -
3FB2 G 3FB3 3FB2

P2
FJ1

L1
PSW4530 POSI @ 450 CTS MAX. OR -
HYJOIT-TEC BEAM TO MAN. DESIGN & SPEC.

D
D

D
G
G WP1 WP1
BRACING
WP1 WP1

G
ALL WALLS TO BE BRACED IN ACCORDANCE WITH
G

G
FJ1 AS 1684 STANDARDS.

G
BRACING SHALL INITIALLY BE PLACED IN
P2

DS
P2

P2

L1
EXTERNAL WALLS AND WHERE POSSIBLE AT
4FB1 4FB1 4FB2 THE CORNER OF THE BUILDING. REMAINING
P1

L1 BRACING SHALL THEN BE EVENLY


DISTRIBUTED THROUHOUT THE INTERNAL
WALLS.

G
R1

G
UNIT 4
MINIMUM LENGTH OF PLYWOOD BRACING TO
G BE 900 MM.
4FB3

C1 4FB4
ALL FRAMING MEMBERS ARE TO BE ANCHORED

C1
AGAINST UPLIFT IN ACCORDANCE WITH 1684.
SHADED REGION

L1
DENOTES
BALCONY AREAS G

4FB1
C1
C1

C1
L1
P2

4FB4
P1

D
C1
G

4FB4

C1

C1
2 L4 2 L1 L1
FJ1 SC SC

G G G

LEVEL 1 FRAMING PLAN


G - DENOTES TYPE G PLYWOOD (UNIT TYPE A). REFER TO DRAWING S16 FOR DETAILS
D - DENOTES TYPE D METAL STRAP (UNIT TYPE B) REFER TIMBER FRAMING TO AS1684
AND DRAWING S16 FOR DETAILS

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof LEVEL 1 FRAMING PLAN MR. D. LAND 1:50 (A1)
Structural & Civil Engineer Drawn by
2 27/08/18 COLUMN & BEAM ADDED HT
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S14 2