POINT OF CARE

ACCURATE, WITH-PATIENT TESTING


For in vitro
diagnostic use only.

ACCELERATES CLINICAL DECISIONS


• Test results in minutes—reduce wait times for lab results.
•  Lab-accurate results—make treatment decisions with confidence.
•  Easy to use—Simple, intuitive operation. ®
URGENT CARE
• Chemistry panels
• Troponin
• BNP
ONCOLOGY CENTERS RADIOLOGY /
• Chemistry panels IMAGING CENTERS
• Electrolytes • Creatinine
• Hematology • Chemistry panels

ONE VERSATILE
SYSTEM FOR MANY
POINTS OF CARE.
The handheld i-STAT System offers the power
and versatility to meet a range of point-of-care
POST-ACUTE / testing needs in a variety of clinical settings. AMBULATORY
LONG-TERM CARE SURGERY CENTERS
• Chemistry panels • Chemistry panels
• Blood gases / Lactate • Electrolytes
• Troponin • Hematology
• BNP • ACT / PT INR

HOSPITAL FAMILY PRACTICE /


INPATIENT /OUTPATIENT INTERNAL MEDICINE
• Chemistry panels • Chemistry panels
• Cardiac Markers • Electrolytes
• Blood Gas • Hematology
• Pregnancy • Pregnancy
®
TRANSFORM PATIENT CARE WITH FAST,
ACCURATE WITH-PATIENT TESTING.

LAB-ACCURATE IMPROVE PATIENT


RESULTS IN MINUTES SATISFACTION
Have the clinical information Minimize delays in care and
needed to make treatment reduce return visits due
decisions during the patient’s visit. to unavailable lab results.

SIMPLIFY TESTING BROAD TEST MENU


Easy, intuitive operation. Lab-accurate results for a
wide range of tests, including
chemistries, blood gas, coagulation,
cardiac markers, and more.

OPTIMIZE SYSTEM EFFICIENCY


Eliminate process steps and handoffs, A 2014 study in the American Journal of Clinical
helping to reduce errors, which can Pathology1 found that point-of-care testing significantly
promote patient safety. improved clinical operations, resulting in:
• 21% reduction in tests ordered
• 89% reduction in follow-up phone calls
For in vitro diagnostic use only.
• 85% reduction in follow-up letters
1. Crocker J, et al, Implementation of Point-of-Care Testing in an
Ambulatory Practice of and Academic Medical Center, Am J Clin
• 61% reduction in re-visits
Pathol November 2014;142:640-646. 2. Actual savings can vary • Practice efficiency cost savings totaling $24.64/patient2,3
depending on state-specific factors. 3. Results can vary depending
on point-of-care testing system used.
LAB-QUALITY RESULTS IN A FEW EASY STEPS

STEP 1 STEP 2 STEP 3 STEP 4 (OPTIONAL)


Fill the cartridge with 2 or 3 Close and insert View the results in minutes Upload into data manage-
drops of fresh whole blood. cartridge into the i-STAT. on the i-STAT screen. ment system or print locally.

DATA INTEGRATION AND MANAGEMENT


The i-STAT System readily integrates with major Electronic Medical Records (EMR) systems and Laboratory Information
Systems (LIS) via our Unify data interfacing solution or our Info HQ Manager data management system.

Unify

LIS EMR

or

i-STAT
Downloader

Info HQ Manager

Our Unify data interfacing solution is a smart, simple solution for EMR integration.
• Easily integrates i-STAT System and other point-of-care testing devices with
your EMR system.
• Streamlines testing workflow—reduce or eliminate manual entry of test data.
• Improves efficiency—keep staff focused on patient care.
• Easy to set up and use—adjusts to your EMR workflow requirements.
• Smart—Automatically matches orders with results sent to EMR, according to
user-defined criteria.
PERFORM A WIDE RANGE OF TESTS IN JUST A FEW MINUTES.
®

CLIA-WAIVED PANELS

CHEMISTRY RESULTS IN 2 MINUTES Abbott Part No.

CHEM8+ Na, K, Cl, iCa, TCO2†, Glu, BUN/Urea, Crea, Agap†, Hct, Hgb† CW* 09P31-25

Crea Crea CW 03P84-25

G Glu CW 03P83-25

ELECTROLYTES, HEMATOLOGY RESULTS IN 2 MINUTES


E3+ Na, K, Hct, Hgb† CW 03P82-25

EC4+ Na, K, Glu, Hct, Hgb† CW 03P81-25

6+ Na, K, Cl, BUN/Urea, Glu, Hct, Hgb† CW 03P80-25

MODERATELY COMPLEX PANELS

CARDIAC MARKERS Abbott Part No.

cTnl Troponin I Results in 10 minutes MC** 06P23-25

BNP BNP Results in 10 minutes MC 03P93-25

CK-MB CK-MB Results in 5 minutes MC 03P92-25

BLOOD GAS RESULTS IN 2 MINUTES


G3+ pH, PCO2, PO2, TCO2†, HCO3†, BEecf†, sO2 MC 03P78-50

CG4+ pH, PCO2, PO2, TCO2†, HCO3†, BEecf†, sO2†, Lactate MC 03P85-50

BLOOD GAS, ELECTROLYTES, HEMATOLOGY RESULTS IN 2 MINUTES


CG8+ Na, K, iCa, Glu, pH, PCO2, PO2, TCO2 , HCO3†, BEecf†, sO2†, Hct, Hgb†

MC 03P88-25

EG7+ Na, K, iCa, pH, PCO2, PO2, TCO2†, HCO3†, BEecf†, sO2†, Hct, Hgb† MC 03P76-25

EC8+ Na, K, Cl, pH, PCO2, BUN/Urea, Glu, TCO2†, HCO3†, BEecf†, Agap†, Hct, Hgb† MC 03P79-25

EG6+ Na, K, pH, PCO2, PO2, TCO2†, HCO3†, BEecf†, sO2†, Agap†, Hct, Hgb† MC 03P77-25

COAGULATION
PT/INR Prothrombin Time Results in ≤5 minutes MC 03P89-24

ACT
Celite
Celite ACT Results in <17 minutes MC 03P86-25

Kaolin
ACT Kaolin ACT Results in <17 minutes MC 03P87-25

PREGNANCY
Total ß-hCG ß-hCG Results in 10 minutes MC 05P58-25

*CW = CLIA-WAIVED PANEL **MC = MODERATELY COMPLEX PANEL



Calculated See CTI sheets for full details at abbottpointofcare.com
®

SIMPLE AND COMPLETE


The i-STAT System Distribution Kit comes complete
with downloader/recharger, printer, and electronic
simulator. (Waived Kit Part No. 04J60-20,
Moderately Complex Kit Part No. 04J48-50)

To learn how the i-STAT System can


transform your patient care, contact your
Abbott Point of Care Representative, or visit
www.abbottpointofcare.com

INTENDED USE
Lactate The test for lactate, as part of the i-STAT System, is intended for use in ACT Kaolin The i-STAT Kaolin Activated Clotting Time (KaolinACT) test is an in vitro
the in vitro quantification of lactate in arterial, venous, or capillary whole blood. The diagnostic test that uses fresh, whole blood, and is used to monitor high-dose
i-STAT lactate test is useful for (1) the diagnosis and treatment of lactic acidosis in heparin anticoagulation frequently associated with cardiovascular surgery.
conjunction with measurements of blood acid/base status, (2) monitoring tissue
hypoxia and strenuous physical exertion, and (3) diagnosis of hyperlactatemia. ACT Celite® The i-STAT Celite Activated Clotting Time (CeliteACT) test is an in vitro
diagnostic test that uses fresh, whole blood, and is useful for monitoring patients
cTnl The i-STAT Cardiac Troponin l (cTnl) test is an in vitro diagnostic test for the receiving heparin for treatment of pulmonary embolism or venous thrombosis, and
quantitative measurement of cardiac troponin l (cTnl) in whole blood or plasma. for monitoring anticoagulation therapy in patients undergoing medical procedures
Measurements of cardiac troponin I are used in the diagnosis and treatment of such as catheterization, cardiac surgery, surgery, organ transplant, and dialysis.
myocardial infarction and as an aid in the risk stratification of patients with acute
coronary syndromes with respect to their relative risk of mortality. PT/INR The i-STAT PT, a prothrombin time test, is useful for monitoring patients
receiving oral anticoagulation therapy such as Coumadin® or warfarin.
CK-MB The i-STAT CK-MB test is an in vitro diagnostic test for the quantita-
tive measurement of creatine kinase MB mass in whole blood or plasma samples. ß-hCG The i-STAT Total Beta-Human Chorionic Gonadotropin (ß-hCG) test is an
CK-MB measurements can be used as an aid in the diagnosis and treatment of in vitro diagnostic test for the quantitative and qualitative determination of ß-hCG
myocardial infarction (MI). in venous whole blood or plasma samples using the i-STAT 1 Analyzer Systems. The
test is intended to be used as an aid in the early detection of pregnancy and is for
BNP The i-STAT BNP test is an in vitro diagnostic test for the quantitative mea- prescription use only.
surement of B-type natriuretic peptide (BNP) in whole blood or plasma samples
using EDTA as the anticoagulant. BNP measurements can be used as an aid in the
diagnosis and assessment of the severity of congestive heart failure. For full details, see CTI sheets at abbottpointofcare.com

Abbott Point of Care Inc. 400 College Road East, Princeton, NJ 08540 (609) 454-9000 (609) 419-9370 (fax)

For in vitro diagnostic use only. © Abbott Point of Care Inc. i-STAT is a registered trademark of the Abbott Group of companies in various jurisdictions. 047010 Rev. A 03/17