Professional Documents
Culture Documents
Relief Valves
J 285601 Seat
J 1485 Locknut
zJ 283949 Retainer
Assemble 285601 seat with J 64520 Washer
cross hole facing up as
shown. J 283948 Plunger
YJ 262332 ‘O’Ring
J COVER
MODEL J WASHER SPRING
SPRING
C*5–10**–B–100/110 291822
2280
C*5–H10**–BV–100/110 291821
C*5–10**–C–100/110 291822 J Included In Cover S/A
233110 583937
C*5–H10**–CV–100/110 291821
C*5–10**–F–100/110 Y Included In F3 Seal Kit 696930
2281 291822
(includes pilot valve seals)
C*5–H10**–FV–100/110 291821
Lubricate With Oil Before Assembly
z Not Available For Sale
Note
Parts Prefixed With A Symbol Available
Only In Kits.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 Seals for mineral oil & 11 Manual override options (included 16 Electrical connections (F type coil
fire resistant fluids in pilot valve model code) only) omit if not required
2 Relief valve Blank – Plain override solenoid ends only T – Wired terminal block
H – Waterproof override solenoid ends PA – Instaplug male receptacle only
3 Connections only PB – Instaplug male & female receptacle
H2 – Waterproof override both ends of PA3 – Three pin connector
G – Subplate mounting single solenoid PA5 – Five pin connector
S – Straight threads M – Serviceable manual overrides in
T – NPTF threads solenoid ends only 17 Housing (F type coils only)
4 Solenoid controlled P2 – Plain override both ends of single W – 1/2 NPT thread wiring housing
solenoid J – 20 mm thread wiring housing
5 High flow Y – Lockable manual overrides solenoid
Omit for standard models ends only 18 Electrical options
Z – No overrides in either end 1 – ISO with fitted plug, U type coils only
6 Valve size
12 Solenoid energization identity 6 – ISO with fitted plug, with lights, U type coils
10 – 1–1/4”–1.6250 straight thread only
or 1–1/4” NPTF Blank – Standard arrangement for ANSI
B93 9 (energise solenoid A for flow P to A 19 Solenoid indicator lights (F build
7 Pilot spool function port) only) To be used with T terminal block
V – Solenoid identification determined by models.
0,1, or 2 Indicates venting condition (Omit if not required)
position of solenoid. (Solenoid A at port A
8 Pilot spool spring arrangement end and/or solenoid B at port B end.
20 Coil indentification
(All 4 & 8 spools are always V code)
A – Spring offset
13 Flag symbol heading electrical 21 Pilot valve code (tank pressure
C – Spring centered
options & features rating)
F – Spring centered, shift to center
2 – 10 bar (145 psi) use with switch
9 Pressure range 14 Spool position monitoring switch
models S*
(tank pressure rating 10 bar only)
5 – 100 bar (1450 psi) DG4V–3S–60
B – 125–1000 psi S1 – Switch, normally open, U coils only 6 – 160 bar (2300 psi) DG4V–3–60
C – 500–2000 psi S2 – Switch, normally closed, U coils only 7 – 210 bar (3000 psi) DG4V–3–60
F – 1500–3000 psi S3 – Switch, wired normally open, P*
S4 – Switch, wired normally closed, P* 22 Pilot valve port orifices
10 High vent (Req’d for high flow
models) S5 – Switch, free leads, FW & FJ only
23 Design
Blank – Omit for low vent models 15 Coil type
100 – DG4V3S–60
U – ISO 4400 Standard pilot valve
F – Flying lead 110 – DG4V3–60
SP1 – Single 6,3 series spade to IEC 760 High performance pilot valve
SP2 – Dual 6,3 series spade to IEC 760
24 Special modifications (omit if not
required)
Printed in U.S.A.