You are on page 1of 2
GOLDWAY APhilips company CTG7 Fetal/Maternal Monitor ‘¢ TYTFT color screen, adjustable to any angle 0-90° Displays 3 waveforms with numerics Single fetus monitoring, Uterine Activity standard “Twin fetus monitoring optional Maternal ECG/HR, NIBP and SpO,/PR monitoring optional ‘Automatic fetal movement display "Manual fetal movement marker, visible on waveform display and recording Event marker key for quick notation of important events Selectable FHIR sound source between USt and US2 transducer Incegraced transducer probe holder 150mm integrated recorder ‘TR-hour trend review and printing Fetal waker device optional PHILIPS CTG7 Fetal/Maternal Monitor Fetal Heart Rate (FHR) Parameter FHI, FUR? (optional) Measurement range 50240 bpm Accuracy 50-240 bpm: £2 bpm; 211-240 bps 34 bpm Sweep speed 123ewmn Uterine Activity (TOCO) Measuremenc range 9-100 TOCO baseline 5.10, 15,20 Geleecable) Maternal ECGIHR (MECG) (optional) Ulead ype Sead Lead election: waa Hitmeaturement range: 15 bprn= 300 bpm Accuracy 1 bpm or #1% whichever i greater Sweep speed 125,25 mmis Gain selection: HAA VE A x2. 34, Ato Maternal Non-Invasive Blood Pressure (NIBP) (opelonal) Method: “Automatic exeilometric Parsmeters SYSIDIAIMAP. Operating modes: MarallAutoiSTAT ‘gts measure intervai:——1-10, 15, 30,60, 99,120, 180,240,480 minute ntervai tints ramtightPa CCl pressure range: 0.300 mtg (0 kPa 40 KP) Measureenent snd alarm range: SYS: 30 mmg- 254 mig (4.0 KPa - 23.9 kPa) DIA: 10 mb = 220 mmHg (1.3 KPa = 29.3 kPa} Accuracy: Max. Mean Error: 25 mH (20.7 kP3) ax. Sed. Deviation: Bimmne(1.1 KPa) (Overpressure prevections Yes Maternal $p0 JPR (optional) Pp 590, oct Meaurenebt range 9.100%, Aeouaee TO-A00K, depends on sensor 0.49%, unepecifiod ‘Waveform speed 125 min, 25 mi, SO mls PRmeasurement range: 30 bpin-300.bpm Accuracy 41 bpm or £2%. whichever is greater Data Review and Si Ti-hour wend graph of fea parameters 00 Sosa parameters, erend table Recorder Type Bullen thermal recorder, 150 rm Prinemade: Resl-eme recarding, eee recording, selectable trends prineing Prine speed 423 eninin Prine paper: Standard Z-fol, 150000 Ine! standard: 50~ 270 bpm; USA standard: 30-240 bpm Color TFT LED, adjustable Ss Resokation 480 234 packs Chancel 3 channels (FHRUFHR2, TOCO, 5p0, or MECG) Power Supply [AC power input 100.240 V AC, S060 He Bancery son baetary ‘maximum 4 hours ef eondnuous monitoring FHR and TOCO Parameters Standard: FHRI, Ucerine Accivcy (TCO), Auro!Marual Fetal Movement (Optional: FHR2, Maternal ECGIMR, Maternal NIBP and $p0 JPR Weight & Dimensions Net Weight ‘Approx. 5k (with battery) Dimensions: 30 ras (W) x 340 men (0) 3 120 om (H) Safety Approval Quality System Safecy standard TECé0s0t- ualey syscem: 1508001 & 15013485 cereiied CCE marking ecording to che Counel Directive 9342/EEC Specifications subject to chonge without notice sannonpntlcom PHILIPS

You might also like