You are on page 1of 6
ROYAL& a SUNALLIANCE dem preendsieh is Din A003 + Modericy. Bt 2 bes eer et sec heels Tene Eorthe tention of Poticy — FTMO209 HEALTH AND SAFETY EXECUTIVE temxa BCK1083 THE PRESSURE SYSTEMS SAFETY REGULATIONS 2000 res 2963/2 REPORT OF THOROUGH EXAMINATION OF AN | Tiefegevcigh cominaion ITEM WITHIN A PRESSURE SYSTEM 2103/00 2 COATES HIRE (UK) LTD & RENTAIR LTD MOVED ABOUT PLANT BASED ANY SITE OF OPERATION IN GREAT BRITAIN OR, NORTHERN IRELAND ‘STEVE PIERCE 8) Legation of te Ste. oe iad 3a} Bese Sten 38) Dessipion ft len 36) MaerNane 34) Disinciverunber Be) Date oncrasion ff Dato date of at SS BSniaioaroe Ropero amie st 6 Deatef eaminain COATES HIRE (UK) LTD & RENTAIR LTD. KIRKTON AVENUE FACILITY DYCE ABERDEENSHIRE ‘AB21 OBF F.T.R.2963 - TRANSPORTABLE COMPRESSED AIR SYSTEM AND PROTECTIVE DEVICES 2963 - $ -002 HORIZONTAL START AIR RECEIVER . TRANSPORTABLE COMPRESSOR - ZONE 2 AJ METAL PRODUCTS 25804 2005 EN286-1:1998 Class 2 coded vessel Corrosion allowance: 0.5 mm Notified body: Zurich - CE0037 2005 to a pressure 20.69 Bar Not applicable endesseoretoul” THOROUGH INTERNAL & EXTERNAL AS ACCESSIBLE WITH HAMMER & SPOT ULTRASONIC THICKNESS TESTS. EXTERNAL EXAMINATION UNDER NORMAL OPERATING CONDITIONS. 7 Pasinaesuiie Externally in way of mountings and supports, Internally except as seen from openings 8 Condition ae) aon In order as accessible 98) ‘tenel In order as accessible Pst Pate of Earinatin 28103107 Paget Bibvze10 0 a R ne ” Me) ss 16 Arcatproecive Sealed nit rd ey eons iceman fr ‘sh eed ate heer seule Area ches Soule’ Sof OperingLinis Less em org tompotts tom gretio Gea or Sb Zev Te Spey cnc? Sali of scheme = Dats ony pit Forces} Boteathencaps yen #2 WBertaree18 Report cntnue rom page Yes None Not applicable PS 12.0 BAR ‘TMIN -10 DEG.C TMAX +85 DEG.C No No 28/03/09 Not applicable Suitable for further service Safety relief valve: 2963/2 set to lit at 12.0 Bar. Bench tested againts clients calibrated test rig: 0- 600 psi ‘SIN: D2001/421 Calibrated: 26/10/2007 Due calibration: 27/10/2005 This examination carried out in accordance with the amended Written Scheme of Examination issued by Royal & SunAlliance Engineering on: 28/03/2007, Spot UT readings: Dished ends: 5:0 mm - nominal. Date of Eoin 28103107 Page 2 ROYAL & SUNALLIANCE Report continued fom page? 6 Shell: 4.0 mm - nominal nary conespondeneereaiag tis reps piesetoe iit ADOS Poti FTM0209 teas, BCK1093 User Ret 2969/2 ret erough examination | rane NOPE: Tac de of Not Exminaton specie above inset ote atm ting pope wed with noma malaenance card oat indepeadey fay ace fom NeCoapecat Paste siting ‘Your steaton it daw athe Gp Reet eraolaes he let ofa dat concerning te orany te (ohether 3 DateofEsanination 28/03/07 Report Date 48/04/07 ean - Pager Saneorto Pst ogi Saintes mar wee 17 Soc Sees Nansen hs Biba ‘Rapes iS BM BH Pac fo ns secu anansae 2 ie nspecsion he NOT tet for sl aseamen SISCPD 2001 “Year 2000 Coaforaiy The ear 2000 orany there) Recuzent) and ROYAL & SUNALLIANCE Saar rating thi Dieiee AOS sy ive eot eg gene Poy -FTMOZ09 HEALTH AND SAFETY EXECUTIVE BCKse4 Ite No THE PRESSURE SYSTEMS SAFETY REGULATIONS 2000 3. .¢ 2963/1 REPORT OF THOROUGH EXAMINATION OF AN [ the eitihorough eaininaton ITEM WITHIN A PRESSURE SYSTEM. pacar COATES HIRE (UK) LTD & RENTAIR LTD MOVED ABOUT PLANT BASED ANY SITE OF OPERATION IN GREAT BRITAIN OR, NORTHERN IRELAND. Perttecuotinct STEVE PEARCE 2a) Lacon of Sten if different tote RENTAIA PLC. KIRKTON AVENUE PITMEDDEN INDUSTRIAL ESTATE, DYCE ABERDEENSHIRE (AB21 OBF aa of the Bree - TRANSPORTABLE/MOBILE COMPRESSED AIR SYSTEM & PROTECTIVE 30) resort 2963 -S -002 3b) Description of te tem VERTICAL AIR/OIL RECEIVER - TRANSPORTABLE COMPRESSOR - ZONE 2 Je) Maker Name LE RESERVOIR SA 36) isincveninber ——-40209-22 Je) Datefomunacin (4990 Rem es... BSS169/3/E coded vessel. eo Initial thorough internal examination carried out by Royal & SunAlliance Engineering on: Dae on dea oft pdr at Dae an data of tat Resear Desai of exertion 22/03/2005 (Written scheme of examination refers.) 10/05/1990 to a pressure of 21.0 Bar. Not applicable auliewcwrsiow THOROUGH EXTERNAL EXAMINATION AS ACCESSIBLE WITH HAMMER & SPOT ULTRASONIC THICKNESS TESTS. EXTERNAL EXAMINATION UNDER NORMAL OPERATING CONDITIONS, 7 Petsinacene Externally in way of mountings and suppor, internally all parts 8 Condon aa) xenat_ In order as accessible 6) ‘monet inaccessible Pst DasefEuninsin ——29/08105 — Page IS dbreao7 sevens a Het Pst ‘atoms Getiw condition Repaln oy) gabe errr Seemed Nae by Wer hey hauitbe Tenruied inode, sera are Eaves Safe Operating Lilo thr tem one Pemponet of itm ro een or ‘Sieon Cy S250 tempore ape condone? Suit of coe Arey canes Dae ofact ov Dai ei conten eat of Bannon Report continued fom page Yes None Not applicable PS 14.0 BAR ‘TMIN “10 DEG.C TMAX +120 DEG.C No No 29/09/11 Not applicable Suitable for further service Safety telet valve ID No: 2963/1, Bench test witnessed, valve observed to blow freely at 14.0 Bar. Tosted against clients calibrated test rig/gauge: Q.- 600 psi S/N: D2001/421 High compressed air discharge temperature cut-out probe operated satisfactorily - new calibrated probe fitted this time, Initial thorough internal examination carried out by Royal & Sundlliance Engineering on: 22/03/2005 - J Brewer (A003) Dose of Examination 29109105 Page 2 1B 0raa0r ROYAL & SUNALLIANCE Ieany conespondence ling is repr pcs gue init A003 Repo conic fom ope? Poliy FTMO209 enn, BCKBO4 Ret 2963/1 The ne ough exten hou bo somsetee oy Bojan 16 Gimnaion’~~~—-THIS examination carried out in accordance with the emended written scheme of sea, examination issued by Royal & SunAliance Engineering on: 29/08/2005 Vessel inspected at: Averon Engineering Inverurie, [NOTE The da of Nox Exist spoil shove ie sujet he se sig propery ed mh ‘he Competent Person making this Exam ation Z arte bees pyey mold “Your ateton dao the i ah nspocton ha NOT teed og Seer ot et BSP reac ) he ifcto dats oacening DateofEaminnion 29/09/05 Repent Dae 07/10/05 6 MJ E Brewer Pst i os «2 ‘ths Bion on -~ a —7_ 5

You might also like