You are on page 1of 3

--------TECHNICAL DATA SHEET---------

.
BOIS Dual Pot Sand Filter unit HT / HF

BOIS GAS - OIL SOLIDS TREATMENT UNIT, TECHNICAL SPECIFICATIONS


(Patent pending)

PERFORMANCE: WP 10.000 psi, Sour Service, High Temperature / Flow


Max. Working Pressure (psi) 10,000 PSI (690 bar)
1
Inlet / oulet block connections 4 /16" 10K Flanged blocks
Supplied X-Over inlet 4 1/16” 10K flange x 3” Weco fig. 1502 female
Supplied X-Over inlet 4 1/16” 10K flange x 3” Weco fig. 1502 female
increased Gas Flow capacity Up to 2 x 1.0 MM m3/day using both vessels
Liquid flow capacity Up to 12,000 Bpd
Vessel OD (inch) 14"
Filter element O.D (inch) 4½"
Filter mesh sizes Wire Screen 50 - 600 Microns
Max differential pressure created by screens 0.1 – 8.0 bar (depending flowrates / medium)
Max Differential pressure across the filter element 80 Bar
Filter collapse pressure at ca. 93 Bar differential
High Temp. Class up to 350F (177C)

Flush system Integrated 4 x 2” gate valves and 1 x check valve


(on inlet) with 2” 1502 female connections

Frame Design Code Det Norske Veritas 2-7.1, see page 2


Service Sour (H2S) service, Per NACE MR-01-75 latest rev.
Dimensions 400cm x 240 cm x 250cm H x W x D,
Weight 10,5 ton

Dimensions of 5ft Tool Container 2.7-1 : 168 x 195 x 264 D x W x H


Weight of Tool Container : 2800kg

Both units will fit on one 40ft flat rack

Complete system designed, build and certified to PED 97/23/EC and ASME codes.

TDS-Dualpotsandfilter 10K HT-HF December 2012 Rev1


Page 1 BOIS 10k Dual Pot Sand Filter Unit HT / HF
--------TECHNICAL DATA SHEET---------
The unit is skid mounted, and complete with in- and outlet manifold, double gate valves on the inlet and
connections to register differential pressure across the filters

It is the first solids filtration unit, where ANNULAR flow is applied in the vessel, to increase
Sand storage capacity, as well as reducing particle velocity across the filters and thus increasing
filter life.

Critical parts in the filter vessel (inlet area) are designed as disposable, in order to give the
Vessel a low cost wear protection.
GENERAL DESCRIPTION

The sand-filter consists of two vertical vessels, each vessel holding one inner filter assembly. The two vessels are
manifold on a skid such; those one or both vessels can be on-stream at any time.
Normally, one vessel is in use, in order to facilitate cleaning of the other.

The product flow-path through the filter is "outside-in" to increase the filter contact area, reducing actual wear on the
filter element.

FILTRATION SYSTEM

The Wire Screen filter consists of one element, which is mounted concentrically. Opposite to the Laser Cut Screen, The
Wire Screen filter has more slots. The filter assembly element can be altered in an early manufacturing stage, if
required by the application
Advantage * Minimum Mesh size 50 Micron
* Filter collapse pressure 93 bar ∆P
* Maximum OD 14¼ inch
* Gas Flow capacity up to 2 x 1.0 MM m3/day using both vessels simultaneously and having large
bore inlet / outlet piping connected
* Liquid Flow capacity up to 12,000 Bpd

The inner filter elements are designed to stop sand/debris transport, without obstructing Liquid and or gas flow through
the unit.

Gas velocities across the filter elements are greatly reduced, minimising actual filter wear and increasing its life span.

CLEANING

A series of high-pressure water injection nozzles are positioned on the outer vessel diameter, to
facilitate sand removal between vessel and filter element.
The sand/water mixture is flushed out off the vessel through 2" cleaning hatches, positioned on the bottom
end of the outer vessel.
Cleaning / flushing time per vessel approx. 15 minutes.

FILTER ELEMENT REMOVAL IS NOT REQUIRED DURING OPERATION

If, at a point, the filter element requires inspection or replacement due to physical wear, the entire
element can be retrieved from the outer vessel top-end.

ADDITIONAL INFORMATION:

Design Codes and Standards ASME 8 DIV.2, API 6A, frame DNV 2.7-1 and. The unit is H2S service according to
NACE MR-01-75/ISO15156. The valves are level PSL- 3 documented.
Design temp -20 F, +350 (177C), PED 97/23/EC
Design pressure WP 10.000psi, TP 15.000psi

Design Codes of interconnecting piping ANSI B31.3, API 6A, Sour Service according to NACE MR-01-75
Design Temperature -20 F, +350 F (177C) , PED 97/23/EC

TDS-Dualpotsandfilter 10K HT-HF December 2012 Rev1


Page 2 BOIS 10k Dual Pot Sand Filter Unit HT / HF
--------TECHNICAL DATA SHEET---------
Double block inlet valves / outlet valves, one off by-pass valve 3” 10k; 4 1/16” Full ID inlet / outlet block

For the removal of the filter screens there are 2 Jin poles with chain hoists available fully certified.
The removing of the screens is only necessary for changing to another size or integrity inspection of the installed
screens.
The cleaning of the screens will be achieved by flushing from the outside using an air driven membrane pump with
2” fig 206 weco couplings (and spare membranes).
There are no extra screens, standard in the Filter Unit package but they are optional. On long term operations there
is a toolbox / container travelling with the Filter Unit with a selection of consumable spares e.g. gaskets, gauge,
valves etc. which are necessary for operating and maintaining the Unit.

The volume (annular space) between filter screen and body is approx. 125 L for each filter. The filter pot each is
approx. 200 L.

BOIS Equipment Rentals B.V. BOIS Asia Equipment Rentals Pte Ltd BOIS Middle East Equipment Rentals Ltd...
(Heerhugowaard) (Singapore) (Dubai)
Tel.: +31 (0)85-0210090 Tel.: +65 62149260 Tel.: +971 432 40044
Fax: +31 72 574 3185 Fax.: PO Box 113688
E mail: info@boisbv.com E mail: singapore@boisbv.com E mail : dubai@boisbv.com

TDS-Dualpotsandfilter 10K HT-HF December 2012 Rev1


Page 3 BOIS 10k Dual Pot Sand Filter Unit HT / HF