You are on page 1of 2

CONCRETE MIX PROPORTION CALCULATION SHEET for Batching Plant

Design Requirement INPUT


Code name of concrete K-125
Specific compressive strength 125 kg/cm2
Target compressive strength 187 kg/cm2
Max Aggregate size 20 mm
air content 3 %
Slump 10 ± 2 cm
Cement Weight 250 kg/m3
Water cement ratio 50.00 %
Fine aggregate ratio 40.00 % =Fine aggregate/(fine aggregate + coarse aggregate)
Coarse aggregate ratio 60.00 % =Coarse aggregate/(fine aggregate + coarse aggregate)
of above Coarse aggregate GI (60.00) % 𝜌𝑠 ∙ 𝜌𝑔𝐼 ∙ 𝜌𝑔𝐼𝐼
Coarse aggregate GII (0.00) % Ws = 𝑉 ∙
𝑏 𝑐
Admixture I (AE water reduction) 0.000 (% of Cement weight) 𝜌𝑔𝐼 ∙ 𝜌𝑔𝐼𝐼 + 𝜌𝑠 ∙ 𝜌𝑔𝐼𝐼 + 𝜌𝑠 ∙ 𝜌𝑔𝐼
𝑎 𝑎
Admixture II (Setting retarder) 0.000 (% of Cement weight)
𝜌𝑠 ∙ 𝜌𝑔𝐼 ∙ 𝜌𝑔𝐼𝐼
WGI = 𝑉 ∙ 𝑎 𝑐
Parameter of Materials 𝜌𝑔𝐼 ∙ 𝜌𝑔𝐼𝐼 +𝜌𝑠 ∙ 𝜌𝑔𝐼𝐼 + 𝜌𝑠 ∙ 𝜌𝑔𝐼
𝑏 𝑏
Unit Weight INPUT isi
𝜌𝑠 ∙ 𝜌𝑔𝐼 ∙ 𝜌𝑔𝐼𝐼
Cement (portland cement type I) 1.500 t/m3 v WGII = 𝑉 ∙
𝑎 𝑏
Fine Aggregate (Sand) 1.500 t/m3 v 𝜌 ∙ 𝜌 + 𝜌 ∙ 𝜌 +𝜌𝑠 ∙ 𝜌𝑔𝐼
𝑐 𝑔𝐼 𝑔𝐼𝐼 𝑐 𝑠 𝑔𝐼𝐼
Coarse Aggregate A 1.450 t/m3 v Where ;
Coarse Aggregate B 1.450 t/m3 V: Absolute volume of aggregate (m3)
Admixture I (AE water reduction) 1.100 t/m3 Ws : Weight of fine aggregate (sand) (kg/m3)
Admixture II (Setting retarder) 1.050 t/m3 WGI : Weight of coarse aggregate I (large size) (kg/m3)
WGII : Weight of coarse aggregate II (small size) (kg/m3)
Specific Gravity INPUT jenis rs : Specific Gravity of fine aggregate (sand) (kg/m3)
Cement (portland cement type I) 3.150 t/m3 rgI : Specific Gravity of coarse aggregate I (large size) (kg/m3)
Fine Aggregate (Sand) ex. Cimalaka 2.650 t/m3 rgII : Specific Gravity of coarse aggregate II (small size) (kg/m3)
Coarse Aggregate I ex. Marongge 2.660 t/m3 a : Ratio of fine aggregate (sand) (%)
Coarse Aggregate II ex. Marongge 2.660 t/m3 b : Ratio of coarse aggregate I (large size) (%)
Admixture I (AE water reduction) 1.100 t/m3 c : Ratio of coarse aggregate II (small size) (%)
Admixture II (Setting retarder) 1.110 t/m3 a+b+c= 100%

Design Parameter
Aggregate
Water Cement Coarse aggregate (gravel/crushed
Material Air content Water - Cement ratio Fine aggregate
Weight Weight stone) Admixture I Admixture II
(Sand)
Large Small
Notation A W/C W C S GI GII
Unit (%) (%) (kg/m3) (kg/m3) (%) (%) (%) (kg/m3) (kg/m3)
a b c
Design Value 3 50.00 125 250 40.00 60.00 0.00 0 0
100

Design Mix Proportion


Aggregate
Cement Fine Coarse aggregate
Material Air content Water Weight
Weight aggregate (gravel/crushed stone) Admixture I Admixture II Total
(Sand) Large Small
Notation A W C S GI GII
Unit (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3) (kg/m3)

Weight (kg) 0 125 250 813.408 1220.112 0 0 0 2408.520

Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)

Absolute 306.946 458.689 0.000


30.000 125.000 79.365 0.000 0.000 1000.000
Volume (litter) 765.635

Page 1 K-125
CONCRETE MIX PROPORTION CALCULATION SHEET
For Portable Mixer by Volumetric Method
Design Requirement
INPUT
Capacity of Portable Mixer 0.8 m3
Cement weight for one batching 50 kg

Design Mix Proportion for Portable Mixer


Aggregate
Cement Fine Coarse aggregate
Material Air content Water Weight
Weight aggregate (gravel/crushed stone) Admixture I Admixture II Total
(Sand) Large Small
Notation A W C S GI GII
Unit (kg/mixer) (kg/mixer) (kg/mixer) (kg/mixer) (kg/mixer) (kg/mixer) (kg/mixer) (kg/mixer) (kg/mixer)

Weight (kg) 0 25 50 162.682 244.022 0 0 0 481.704

Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Absolute
6.000 25.000 15.873 61.389 91.738 0.000 0.000 0.000 200.000
Volume (litter)
Size of Mixer is Suitable

Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Unit Weight
6.000 25.000 33.333 108.455 168.291 0.000 0.000 0.000 341.079
Volume (litter)

Fine Coarse aggregate


Box Size aggregate (gravel/crushed stone)
(Sand) Max. 20mm Max. 25mm
Length (m) 0.400 0.400
Width (m) 0.300 0.300
Height (m) 0.310 0.320 Height to be Adjusted
Volume (lit) 37.200 38.400

Number of Box (times) 2.9 4.4

CONCRETE MIX PROPORTION CALCULATION SHEET


For Trial Mixing

Design Requirement
INPUT
Number of Test Piece 6 Nos.
Volume of test piece 5.301 lit/no.
Round-up 6 lit/no.
Volume of Slump test 6 lit
Volume of Air content test 0 lit
Necessary mixing volume 42.00 lit For 6 test pieces + Slump test

Design Mix Proportion for Portable Mixer


Aggregate
Cement Fine Coarse aggregate
Material Air content Water Weight
Weight aggregate (gravel/crushed stone) Admixture I Admixture II Total
(Sand) Large Small
Notation A W C S GI GII
Unit (kg) (kg) (kg) (kg) (kg) (kg) (kg) (kg) (kg)

Weight (kg) 0 5.250 10.500 34.163 51.245 0.000 0.000 0.000 101.158

Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Absolute
1.260 5.250 3.333 12.892 19.265 0.000 0.000 0.000 42.000
Volume (litter)
For 6 test pieces + Slump test

Page 2 K-125