Professional Documents
Culture Documents
Design Parameter
Aggregate
Water Cement Coarse aggregate (gravel/crushed
Material Air content Water - Cement ratio Fine aggregate
Weight Weight stone) Admixture I Admixture II
(Sand)
Large Small
Notation A W/C W C S GI GII
Unit (%) (%) (kg/m3) (kg/m3) (%) (%) (%) (kg/m3) (kg/m3)
a b c
Design Value 3 50.00 125 250 40.00 60.00 0.00 0 0
100
Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Page 1 K-125
CONCRETE MIX PROPORTION CALCULATION SHEET
For Portable Mixer by Volumetric Method
Design Requirement
INPUT
Capacity of Portable Mixer 0.8 m3
Cement weight for one batching 50 kg
Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Absolute
6.000 25.000 15.873 61.389 91.738 0.000 0.000 0.000 200.000
Volume (litter)
Size of Mixer is Suitable
Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Unit Weight
6.000 25.000 33.333 108.455 168.291 0.000 0.000 0.000 341.079
Volume (litter)
Design Requirement
INPUT
Number of Test Piece 6 Nos.
Volume of test piece 5.301 lit/no.
Round-up 6 lit/no.
Volume of Slump test 6 lit
Volume of Air content test 0 lit
Necessary mixing volume 42.00 lit For 6 test pieces + Slump test
Weight (kg) 0 5.250 10.500 34.163 51.245 0.000 0.000 0.000 101.158
Unit (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit) (lit)
Absolute
1.260 5.250 3.333 12.892 19.265 0.000 0.000 0.000 42.000
Volume (litter)
For 6 test pieces + Slump test
Page 2 K-125