You are on page 1of 1

Microbox / Microskid 160-3-1500-15

COMPRESSOR DATASHEET v 2.00


Customer Data Instrumentation Full

Company Base Parameters Sm3/h at 1.01 bara, 15.0 °C


Elevation 3500 m
Unit Data Ambient Temperature 37.78 ºC
Model 160 3 1500 15 Suction Temperature 27 ºC
Gas Specific Gravity 0.65

Performance Data
MINIMUM IN.PRESSURE WORKING PRESSURE MAXIMUM IN.PRESSURE
Suction Pressure 6.00 bar 14.00 bar 15.00 bar
Discharge Pressure 255 bar 255 bar 255 bar
Flow 556 Sm3/h 1271 Sm3/h 1360 Sm3/h
Power 85 kw 144 kw 152 kw
Specific Consumption 0.152 kwh/Sm3 0.114 kwh/Sm3 0.112 kwh/Sm3
COMPRESSION STAGES
1 2 3 4
Cylinder #M10D 100 1500 #M10T 80 1500 #A05T 40 1500
Bore In (mm) 100.00 80.00 40.00
Inlet Pressure bar 15 54 144
Outlet Pressure bar 55 145 258
Inlet Temperature °C 30 51 50
Outlet Temperature °C 140 136 99
Power Kw 71 49 28

Pressure Alarms
PSL 6.0
Inlet Pressure
PSH 15
PSL 20 60 206
Outlet Pressure
PSH 61 159 275
Safety Relief Valves PSV 63 166 275

Temperature Alarms
TSL
Outlet Temperature
TSH 185 185 185

Graphics

Performance Curves Pressure Alarms


1600 160 300 and Safety Reliefs By Stages

1400 140
250

1200 120
200

1000 100
150
800 80

100
600 60
Outlet Pressure (bar)
Flow (Sm3/h)

Power (kW)

50
400 40

200 20 0
6 7.5 9 10.5 12 13.5 15
Serie16 Serie8

0 0 Stage 2 Outlet Alarm Serie6

6 7.5 9 10.5 12 13.5 15 Stage 1 Outlet Alarm Stage 1

Inlet Pressure (bar) Stage 3 Stage 4

Safety Relief Stage 1 Safety Relief Stage 2


Flow (Sm3/h) Power (kW)
Safety Relief Stage 3 Safety Relief Stage 4

*All values may have a +/-10% variation


**The manufacturer reserves the right to modify totally or partially any of the datasheet indications without any previous notification
***The power and specific consumption are at the compressor axis and do not consider losses for engine performance and equipment auxiliary systems
****The interstages pressures and performance may change depending on the different gas compositions.
*****The alarm values indicated are presented only as a reference and the Galileo's authorized technical service reserves the right of increasing or reducing them
for the equipment performance optimization.
******For MX200 the electric motor is 220 Kwatt

You might also like