Professional Documents
Culture Documents
Edition 02/03/2015
Identification no:
02 02 05 01 003 0 000004
Sika AnchorFix®-3001
Sika AnchorFix®-3001
High-performance, professional epoxy anchoring adhesive
Product Solvent-free, thixotropic, two part, epoxy resin-based, high performance anchoring
Construction
adhesive for threaded rods and reinforcing bars in both cracked and un-cracked
Description concrete.
Uses For the fixing of non-expanding anchors in the following:
Structural work:
Rebar / steel reinforcement anchoring in new and refurbishment works
Threaded rods
Bolts and special fastening / fixing systems
Metalwork, carpentry:
Fixing of handrails, balustrades and supports
Fixing of railings
Fixing of window and door frames
Fire resistance:
Test report from the CSTB institute
REPORT No 26054326/B
®
on Sika AnchorFix -3001 injection systems in conjunction
with concrete reinforcing bar (Ø 8 to 40mm) and subjected
to fire exposure
ICC ES Report
3 1
Galvanised anchor & stainless steel anchors M10 to M30 ( /8 to 1 /4 inch)
Rebars T10 to T32 (No. 3 to No. 10)
Testing according to AC 308 standards.
Report Number: ESR-3608
LEED Attestation:
Form
Colours Part A: off-white
Part B: dark grey / black
Part A+B mixed: grey
Packaging 250 ml standard cartridge, 12 per box.
Pallet: 60 boxes with 12 cartridges.
400 ml side by side cartridge, 12 per box.
Pallet: 50 boxes with 12 cartridges.
600 ml side by side cartridge, 12 per box.
Pallet: 34 boxes with 12 cartridges.
1500 ml side by side cartridge, 5 per box.
Pallet: 50 boxes with 5 cartridges.
Storage
Storage Conditions / 24 months from date of production if stored properly in original unopened, sealed
Shelf-Life and undamaged packaging in cool and dry conditions at temperatures between
+5°C and +20°C. Protect from direct sunlight.
®
All Sika AnchorFix -3001 cartridges have the expiry date printed on the label.
Technical Data
Density Part A: ~1.2 kg/l
Part B: ~1.8 kg/l
~1.70 kg/l (part A+B mixed)
Curing Speed
Temperature Open Time Tgel Curing Time Tcur
+40°C 3 minutes 3 hours
+35°C - +40°C 4 minutes 4 hours
+30°C - +35°C 6 minutes 5 hours
+25°C - +30°C 8 minutes 6 hours
+22°C - +25°C 11 minutes 7 hours
+15°C - +22°C 15 minutes 8 hours
+10°C - +15°C 20 minutes 12 hours
+4°C - +9°C -* 24 hours
*Min. cartridge temperature = +10°C
Mechanical / Physical
Properties
2
Compressive Strength ~85 N/mm (7days, +20°C) (According to ASTM D695)
2
Flexural Strength ~45 N/mm (7days, +20°C) (According to ASTM D790)
2
Tensile Strength ~23 N/mm (7days, +20°C) (According to ASTM D638)
E-Modulus Compressive:
2
~5’000 N/mm (According to ASTM D695)
Tensile:
2
~5’500 N/mm (According to ASTM D638)
Design For design details, please refer to the separate documentation provided: “Technical
Documentation Sika AnchorFix®-3001” Ref: 870 43 10
System
Information
Application Details
Consumption / Dosage Material consumption per anchor in ml
Thread Ø
Hole Ø
Theoretical volume [ml]
@ a certain hole depth [mm]
mm 80 90 110 120 130 140 160 170 180 200 210 220 240 260 280 300 350 400
M8 10 3.4 3.8 4.6 5.0 5.4 5.9 6.7 7.1 7.5 8.4 8.8 9.2 10.1 10.9 11.7 12.6 14.7 16.8
M10 12 4.4 5.0 6.1 6.6 7.2 7.7 8.8 9.4 9.9 11.0 11.6 12.1 13.2 14.3 15.4 16.5 19.3 22.0
M12 14 5.6 6.3 7.7 8.4 9.1 9.8 11.2 11.8 12.5 13.9 14.6 15.3 16.7 18.1 19.5 20.9 24.4 27.9
M14 16 6.9 7.7 9.5 10.3 11.2 12.0 13.8 14.6 15.5 17.2 18.1 18.9 20.6 22.4 24.1 25.8 30.1 34.4
M14 18 11.2 12.6 15.4 16.8 18.2 19.6 22.4 23.8 25.2 28.0 29.4 30.8 33.6 36.4 39.2 42.0 49.0 56.0
M16 18 7.8 8.8 10.8 11.8 12.7 13.7 15.7 16.7 17.6 19.6 20.6 21.6 23.5 25.5 27.4 29.4 34.3 39.2
M16 20 12.6 14.1 17.3 18.8 20.4 22.0 25.1 26.7 28.3 31.4 33.0 34.5 37.7 40.8 44.0 47.1 55.0 62.8
M20 22 10.8 12.2 14.9 16.2 17.6 18.9 21.6 23.0 24.3 27.0 28.4 29.7 32.4 35.1 37.8 40.5 47.3 54.0
M20 24 16.6 18.6 22.8 24.8 26.9 29.0 33.1 35.2 37.3 41.4 43.5 45.5 49.7 53.8 58.0 62.1 72.5 82.8
M20 25 19.7 22.1 27.1 29.5 32.0 34.4 39.4 41.8 44.3 49.2 51.7 54.1 59.0 64.0 68.9 73.8 86.1 98.4
M24 26 14.2 16.0 19.6 21.4 23.1 24.9 28.5 30.3 32.0 35.6 37.4 39.2 42.7 46.3 49.8 53.4 62.3 71.2
M27 30 19.4 21.9 26.7 29.2 31.6 34.0 38.9 41.3 43.7 48.6 51.0 53.5 58.3 63.2 68.0 72.9 85.1 97.2
The indicated filling quantities are calculated without wastage. Wastage 10 - 50%.
The filled quantity can be monitored during injection with the help of the scale
on the catridge label.
Substrate Quality Mortar and concrete must be older than 28 days.
Substrate strength (concrete, masonry, natural stone) must be verified.
Pull-out tests must be carried out if the substrate strength is unknown.
The anchor hole must always be clean, dry, free from oil and grease, etc.
Loose particles must be removed from the holes.
Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or
any other substances and particles such as dirt etc.
Application
Instructions
Mixing Part A : part B = 1 : 1 by volume
Mixing Tools Getting the cartridge ready:
250 Cartridge:
- Pull out the plug
400 / 600 &1500ml Cartridges:
- Pull out the red plug
When work is interrupted the static mixer can remain on the cartridge after the gun
pressure has been relieved. If the resin has hardened in the nozzle when work is
resumed, a new nozzle must be attached.
The drill hole must be cleaned with by compressed air, using an air
lance, starting from the bottom of the hole. (at least twice) until
return air stream is free of noticed dust. Oil-free compressors shall
be used, minimum pressure:6 Bar (90 psi)
The drill hole must be thoroughly cleaned with the special steel
brush (brush at least twice). The diameter of the brush must be
larger than the diameter of the drill hole.
Inject the adhesive into the hole, starting from the bottom, while
slowly drawing back the static mixer. In any case avoid entrapping
air. For deep holes extension tubing can be used.
Insert the anchor with a rotary motion into the filled drill hole. Some
adhesive must come out of the hole.
Important: the anchor must be placed within the open time.
During the resin hardening time the anchor must not be moved or
®
loaded. Wash tools immediately with Sika Colma Cleaner.
Wash hands and skin thoroughly with warm soap water.
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
Health and Safety For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
Information physical, ecological, toxicological and other safety-related data.
Legal Notes The information, and, in particular, the recommendations relating to the application
and end-use of Sika products, are given in good faith based on Sika's current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are such
Construction
Sika Services AG
Tüffenwies 16 Phone +41 44 436 40 40
CH-8048 Zurich Telefax +41 44 436 46 86
Switzerland www.sika.com