Product Data Sheet

Edition 02/03/2015
Identification no:
02 02 05 01 003 0 000004
Sika AnchorFix®-3001

Sika AnchorFix®-3001
High-performance, professional epoxy anchoring adhesive

Product Solvent-free, thixotropic, two part, epoxy resin-based, high performance anchoring
Construction

adhesive for threaded rods and reinforcing bars in both cracked and un-cracked
Description concrete.
Uses For the fixing of non-expanding anchors in the following:
Structural work:
 Rebar / steel reinforcement anchoring in new and refurbishment works
 Threaded rods
 Bolts and special fastening / fixing systems

Metalwork, carpentry:
 Fixing of handrails, balustrades and supports
 Fixing of railings
 Fixing of window and door frames

In the following substrates:


 Concrete (cracked and un-cracked)
 Hard natural and reconstituted stone
 Solid rock
 Hollow and solid masonry
 Wood
Characteristics /  Long Open Time
Advantages  Can be used in damp concrete
 High load capacity
 ETA Approval available
 ICC-ES Approval available
 Drinking Water certified
 LEED Attestation available
 Fire resistance test report available
 Seismic testing available
 Styrene-free
 Excellent adhesion to the substrate
 Shrinkage-free hardening
 Standard guns can be used (with the 250ml cartridge)
 Low odour
 Low wastage

1 Sika AnchorFix®-3001 1/8


Tests
Approval / Standards Approvals:

European Technical Approval ETAG 001 Part 5 Option 1


Galvanised anchor & stainless steel anchors M10 to M30 and rebars Ø10 to Ø 32
mm for cracked & non-cracked concrete including seismic factor
EC Cert. 1020-CPR-090-032737
ETA-14 / 0157

European Technical Approval ETAG 001 Part 5 TR023


Post installed rebar connections of the sizes Ø8 to Ø 40 mm
EC Cert. 1020-CPD-032640
ETA-14 / 0368

Fire resistance:
Test report from the CSTB institute
REPORT No 26054326/B
®
on Sika AnchorFix -3001 injection systems in conjunction
with concrete reinforcing bar (Ø 8 to 40mm) and subjected
to fire exposure

IAPMO Evaluation Report


3 1
Galvanised anchor & stainless steel anchors M10 to M30 ( /8 to 1 /4 inch)
Rebars T10 to T32 (No. 3 to No. 10)
Testing according to AC 308 standards.
Report Number: 0292

ICC ES Report
3 1
Galvanised anchor & stainless steel anchors M10 to M30 ( /8 to 1 /4 inch)
Rebars T10 to T32 (No. 3 to No. 10)
Testing according to AC 308 standards.
Report Number: ESR-3608

2 Sika AnchorFix®-3001 2/8


Drinking Water Approval:

Drinking Water System Components NSF / A NSI 61


K-8319

LEED Attestation:

Test report from eurofins


REPORT No G23222_4

3 Sika AnchorFix®-3001 3/8


Product Data

Form
Colours Part A: off-white
Part B: dark grey / black
Part A+B mixed: grey
Packaging 250 ml standard cartridge, 12 per box.
Pallet: 60 boxes with 12 cartridges.
400 ml side by side cartridge, 12 per box.
Pallet: 50 boxes with 12 cartridges.
600 ml side by side cartridge, 12 per box.
Pallet: 34 boxes with 12 cartridges.
1500 ml side by side cartridge, 5 per box.
Pallet: 50 boxes with 5 cartridges.

Storage
Storage Conditions / 24 months from date of production if stored properly in original unopened, sealed
Shelf-Life and undamaged packaging in cool and dry conditions at temperatures between
+5°C and +20°C. Protect from direct sunlight.
®
All Sika AnchorFix -3001 cartridges have the expiry date printed on the label.

Technical Data
Density Part A: ~1.2 kg/l
Part B: ~1.8 kg/l
~1.70 kg/l (part A+B mixed)
Curing Speed
Temperature Open Time Tgel Curing Time Tcur
+40°C 3 minutes 3 hours
+35°C - +40°C 4 minutes 4 hours
+30°C - +35°C 6 minutes 5 hours
+25°C - +30°C 8 minutes 6 hours
+22°C - +25°C 11 minutes 7 hours
+15°C - +22°C 15 minutes 8 hours
+10°C - +15°C 20 minutes 12 hours
+4°C - +9°C -* 24 hours
*Min. cartridge temperature = +10°C

Sag Flow Non-sag, even overhead.


Layer Thickness ~7 mm max.

Mechanical / Physical
Properties
2
Compressive Strength ~85 N/mm (7days, +20°C) (According to ASTM D695)
2
Flexural Strength ~45 N/mm (7days, +20°C) (According to ASTM D790)
2
Tensile Strength ~23 N/mm (7days, +20°C) (According to ASTM D638)
E-Modulus Compressive:
2
~5’000 N/mm (According to ASTM D695)
Tensile:
2
~5’500 N/mm (According to ASTM D638)
Design For design details, please refer to the separate documentation provided: “Technical
Documentation Sika AnchorFix®-3001” Ref: 870 43 10

4 Sika AnchorFix®-3001 4/8


Resistance
Thermal Resistance -40°C to +43°C
+43°C long term

System
Information

Application Details
Consumption / Dosage Material consumption per anchor in ml

Thread Ø

Hole Ø
Theoretical volume [ml]
@ a certain hole depth [mm]

mm 80 90 110 120 130 140 160 170 180 200 210 220 240 260 280 300 350 400

M8 10 3.4 3.8 4.6 5.0 5.4 5.9 6.7 7.1 7.5 8.4 8.8 9.2 10.1 10.9 11.7 12.6 14.7 16.8

M10 12 4.4 5.0 6.1 6.6 7.2 7.7 8.8 9.4 9.9 11.0 11.6 12.1 13.2 14.3 15.4 16.5 19.3 22.0

M12 14 5.6 6.3 7.7 8.4 9.1 9.8 11.2 11.8 12.5 13.9 14.6 15.3 16.7 18.1 19.5 20.9 24.4 27.9

M14 16 6.9 7.7 9.5 10.3 11.2 12.0 13.8 14.6 15.5 17.2 18.1 18.9 20.6 22.4 24.1 25.8 30.1 34.4

M14 18 11.2 12.6 15.4 16.8 18.2 19.6 22.4 23.8 25.2 28.0 29.4 30.8 33.6 36.4 39.2 42.0 49.0 56.0

M16 18 7.8 8.8 10.8 11.8 12.7 13.7 15.7 16.7 17.6 19.6 20.6 21.6 23.5 25.5 27.4 29.4 34.3 39.2

M16 20 12.6 14.1 17.3 18.8 20.4 22.0 25.1 26.7 28.3 31.4 33.0 34.5 37.7 40.8 44.0 47.1 55.0 62.8

M20 22 10.8 12.2 14.9 16.2 17.6 18.9 21.6 23.0 24.3 27.0 28.4 29.7 32.4 35.1 37.8 40.5 47.3 54.0

M20 24 16.6 18.6 22.8 24.8 26.9 29.0 33.1 35.2 37.3 41.4 43.5 45.5 49.7 53.8 58.0 62.1 72.5 82.8

M20 25 19.7 22.1 27.1 29.5 32.0 34.4 39.4 41.8 44.3 49.2 51.7 54.1 59.0 64.0 68.9 73.8 86.1 98.4

M24 26 14.2 16.0 19.6 21.4 23.1 24.9 28.5 30.3 32.0 35.6 37.4 39.2 42.7 46.3 49.8 53.4 62.3 71.2

M27 30 19.4 21.9 26.7 29.2 31.6 34.0 38.9 41.3 43.7 48.6 51.0 53.5 58.3 63.2 68.0 72.9 85.1 97.2

The indicated filling quantities are calculated without wastage. Wastage 10 - 50%.
The filled quantity can be monitored during injection with the help of the scale
on the catridge label.
Substrate Quality Mortar and concrete must be older than 28 days.
Substrate strength (concrete, masonry, natural stone) must be verified.
Pull-out tests must be carried out if the substrate strength is unknown.
The anchor hole must always be clean, dry, free from oil and grease, etc.
Loose particles must be removed from the holes.
Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or
any other substances and particles such as dirt etc.

5 Sika AnchorFix®-3001 5/8


Application
Conditions /
Limitations
Substrate Temperature +4°C min. / +40°C max.
Ambient Temperature +4°C min. / +40°C max.
®
Material Temperature Sika AnchorFix -3001 must be used at a temperature of between +10°C and
+30°C.
Dew Point Substrate temperature during application must be at least 3°C above dew point to
avoid condensation.

Application
Instructions
Mixing Part A : part B = 1 : 1 by volume
Mixing Tools Getting the cartridge ready:

250 ml 400 / 600ml / 1500ml

Unscrew and remove the cap

250 Cartridge:
- Pull out the plug
400 / 600 &1500ml Cartridges:
- Pull out the red plug

Screw on the static mixer

Place the cartridge into the gun and


start application

When work is interrupted the static mixer can remain on the cartridge after the gun
pressure has been relieved. If the resin has hardened in the nozzle when work is
resumed, a new nozzle must be attached.

6 Sika AnchorFix®-3001 6/8


Application Method / Anchors in solid masonry/concrete:
Tools
Drilling of hole with an electric drill to the diameter and depth
required. Drill hole diameter must be in accordance with anchor
size.

The drill hole must be cleaned with by compressed air, using an air
lance, starting from the bottom of the hole. (at least twice) until
return air stream is free of noticed dust. Oil-free compressors shall
be used, minimum pressure:6 Bar (90 psi)

The drill hole must be thoroughly cleaned with the special steel
brush (brush at least twice). The diameter of the brush must be
larger than the diameter of the drill hole.

The drill hole must be then be cleaned again by compressed air,


using an air lance, starting from the bottom of the hole. (at least
twice again) until return air stream is free of noticed dust. Oil-free
compressors shall be used, minimum pressure:6 Bar (90 psi)
The drill hole must be thoroughly cleaned with the special steel
brush again (brush at least twice again). The diameter of the brush
must be larger than the diameter of the drill hole.

The drill hole must then be finally cleaned yet again by


compressed air, using an air lance, starting from the bottom of the
hole. (at least twice) until return air stream is free of noticed dust.
Oil-free compressors shall be used, minimum pressure:6 Bar (90
psi)
Pump approx. twice until both parts come out uniformly. Do not use
this material. Release the gun pressure and clean the cartridge
opening with a cloth.

Inject the adhesive into the hole, starting from the bottom, while
slowly drawing back the static mixer. In any case avoid entrapping
air. For deep holes extension tubing can be used.

Insert the anchor with a rotary motion into the filled drill hole. Some
adhesive must come out of the hole.
Important: the anchor must be placed within the open time.
During the resin hardening time the anchor must not be moved or
®
loaded. Wash tools immediately with Sika Colma Cleaner.
Wash hands and skin thoroughly with warm soap water.

Important Note: Anchors in hollow blocks:


®
Do use Sika AnchorFix -1 for hollow blocks.
®
Cleaning of Tools Clean all tools and application equipment with Sika Colma Cleaner immediately
after use. Hardened / cured material can only be removed mechanically.

7 Sika AnchorFix®-3001 7/8


Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.

Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.

Health and Safety For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
Information physical, ecological, toxicological and other safety-related data.

Legal Notes The information, and, in particular, the recommendations relating to the application
and end-use of Sika products, are given in good faith based on Sika's current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are such
Construction

that no warranty in respect of merchantability or of fitness for a particular purpose,


nor any liability arising out of any legal relationship whatsoever, can be inferred
either from this information, or from any written recommendations, or from any other
advice offered. The user of the product must test the product’s suitability for the
intended application and purpose. Sika reserves the right to change the properties
of its products. The proprietary rights of third parties must be observed. All orders
are accepted subject to our current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.
It may be necessary to adapt the above disclaimer to specific local laws and
regulations. Any changes to this disclaimer may only be implemented with
®
permission of Sika Corporate Legal in Baar.

Sika Services AG
Tüffenwies 16 Phone +41 44 436 40 40
CH-8048 Zurich Telefax +41 44 436 46 86
Switzerland www.sika.com