Sl Description YES NO
Ensure that the type of pipes & accessories used for plumbing and Sanitary are as per
1
specifications
4 Marking on walls has been done with reference to FFL & as per drawing
5 Ensure that marking of pipe lines are truly vertical & horizontal
6 Wall chipping should be done with Cutting Machine & proper tools be used
Ensure that pipes shall be fixed on wall with suitable holder clamps & the height from
7
FFL is as per drawing
Ensure that after blocking of ends with plugs or blind flanges provide an air vent at the
8 highest point & fit a cock for filling water through pump & pressure guage before
pressure testing
9 Ensure that the pressure guage should be connected to pipe line with flexible pipe
11 Ensure that if any leakage found remove that leakage pipe & replace it
15 Test the sanitary line with water for any leakage before laying
17 Ensure the weep hole pipe provided as per details given in the drawing
Signature Signature
Name Name