(Tested in accordance with the requirements in BS 4449: 2005 and in accordance with the test method in ASTM; E8M-13a

“Tension testing of metallic


materials - metric)
Source of steel bar; Roofing’s Rolling Mill Ltd

Testing Details – Using a CTR-E-SERIES-1000 Universal Testing Machine


Nominal Bar Coupler Dimensions Tensile
Type of Yield strength Ratio Failure
S/N. Identification Size Size Length Thickness strength
bar (MPa), Re (Rm/Re) Mode
(Ø mm) (MPa), Rm
(Ø mm) (mm) (mm)
01 Threaded Rebar Ribbed 25 37.1 60.4 6.8 537 620 1.15 Bar Break
Coupler Joint
02 ‘’ ‘’ 25 37.1 60.4 6.7 618 689 1.11 Bar Break
03 ‘’ ‘’ 25 37.0 60.4 6.8 568 643 1.13 Bar Break

Specifications; BS 4449: 2005 For grade B500CWR 485-650 - -

Condition of testing: As delivered by client