2002 IS Catalog

Page

Introduction ............................................................................................................................. 139


Loop-Powered Isolators
KFD0-CS-1.50 (Current repeater / driver / isolator / single-channel) .................................................. 140
KFD0-CS-2.50 (Current repeater / driver / isolator / dual-channel) ..................................................... 141
KFD0-CC-1 (Current converter / single channel / isolator) .................................................................. 142
KFD0-VC-1.50m (Voltage to current converter / single-channel / isolator) ......................................... 143
KFD0-VC-1.10 (Voltage to current converter / single-channel / isolator) ............................................ 144
KFD0-TT-1 (Thermocouple / mV input / single-channel / isolator) ...................................................... 145
KFD0-TR-1 (RTD input / single-channel / isolator) .............................................................................. 146
Analog Isolators
KFDX-DCI (DC current input / current/voltage output / isolator) ......................................................... 147
KFDX-DCV (DC voltage input / current/voltage output / isolator) ....................................................... 148
KFD2-CR-1.300 (2- or 3-wire transmitter input / 4-20 mA current output / isolator) .......................... 149
KFD2-CD-1.32 (Current/voltage driver / current output / isolator) ...................................................... 150
KFD2-CR4-1.20 (Single input / dual output transmitter / repeater / isolator) ...................................... 151
KFD2-STC4-1.20 (HART transmitter power supply / isolator) ............................................................. 152
KFDX-RTD (RTD input / current/voltage output / isolator) .................................................................. 153
KFDX-TC (Thermocouple input / isolator) ........................................................................................... 154
KFD2-UT-1 (Universal temperature input / isolator) ............................................................................. 155
KFD2-UT-1-1 (Universal temperature input / isolator) ......................................................................... 156
KFDX-AC (AC current/voltage input / current/voltage output / isolator) ............................................. 157
KFDX-HZ (Frequency input / current/voltage output / isolator) .......................................................... 158
KFA5-DWB-1.D (Rotational speed limit alarm) .................................................................................... 159
KFA6-DWB-1.D (Rotational speed limit alarm) .................................................................................... 160
KFD2-DWB-1.D (Rotational speed limit alarm) ................................................................................... 161
KFU8-UFC-1 (Universal frequency converter) ..................................................................................... 162
KFD2-UFC-1.D (Universal frequency converter with display) .............................................................. 163
KFD2-UFC-1 (Universal frequency converter / isolator) ...................................................................... 164
KFU8-UFC-1.D (Universal frequency converter / isolator with display) ............................................... 165
Limit Alarm Isolators
KFDA-DCI (DC current input / 2 Form C contact outputs / isolator) ................................................... 166
KFDA-DCV (DC voltage input / 2 Form C contact outputs / isolator) .................................................. 167
KFD2-GS-1.2W (DC current/voltage input / 2 Form C contact outputs / isolator) .............................. 168
KFD2-CRG-1.D (Transmitter power supply / isolator) ......................................................................... 169
KFU8-CRG-1.D (Transmitter power supply / isolator) ......................................................................... 170
KFDA-TC (Thermocouple input / 2 Form C contact outputs / isolator) ............................................... 171
KFDA-RTD (RTD input / 2 Form C contact outputs / isolator) ............................................................ 172
KFDA-GU-1 (Universal input / 2 Form C contact outputs / PC interface / isolator) ............................ 173

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


138 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Introduction
With the variety of process control systems available, it is often necessary to convert an input signal into
a format that the control system will accept. Signal conditioners take signals from an assortment of field
instruments such as thermocouples and RTDs, and convert those signals into any of several standard
instrument signals (1-5 V, 4-20 mA, etc.) while providing isolations.

Signal conditioners are also beneficial to the accurate transfer of these signals and the elimination of
ground loops.

Pepperl+Fuchs signal conditioners utilize the latest technology, offering unparalleled protection against
ground loops while maintaining optimum signal accuracy and complete isolation. There are three basic
types of KF signal conditioners:

Loop Powered Repeaters/Isolators: Loop powered repeaters do not require a separate


power supply. Available in single and dual channel models, these transformer isolated
signal conditioners transfer analog DC signals with each channel working as a DC isolator
providing 2,500 VDC isolation between the input and output.

Analog Isolators: These units require a separate power supply and provide signal
conditioning and 3-way isolation to various input signals.

Limit Alarms: This class of signal conditioners provides two Form C relay outputs with
adjustable high and low switchpoints and selectable control safe and normal operation.
They also require a separate power supply and provide 3-way isolation.

The latter two categories are fully field-configurable and provide 1,800 VDC isolation separating input,
output and power supply. Input and output ranges, modes of operation, switchpoints, etc., can be
programmed in the field via DIP switches on the side of the housing. Some models also offer a PC
interface. Input, zero, and span are adjustable by potentiometer to 50% for all input ranges. The wide-
ranging capabilities and field-configurable settings allow for numerous options in a diverse range of
applications.

All P+F analog isolators and limit alarms also contain the ASIC chip for increased reliability. ASIC (Appli-
cation Specific Integrated Circuitry) substantially reduces failures by virtually eliminating discrete com-
ponents and their solder joints where most faults occur. Printed circuit board connections are reduced
by 70%.

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
139
2002 IS Catalog

Current Repeater/ Technical Data


Driver Single Power Supply Loop powered (not intrinsically safe)
Nominal voltage 12-35 VDC
Channel Isolator
Input Terminals 11+, 12-
Input voltage (Vin) 10-35 VDC
Input current (Uin) 4-20 mA

Power Dissipation
@ 25 mA (Vin < 26.1 V) < 150 mW
@ 25 mA (Vin > 26.1 V) < 400 mW

Output Terminals 1, 2
Output voltage:
10 V < Vin < 26.1 V 0.9 x Vin - (0.23 x current in mA) - 0.7
Vin > 26.1 V 23 V - (0.23 x current in mA)
Output current 4-20 mA
Model Number Short circuit current ≤ 65 mA @ Vin>26.1 V
KFD0-CS-1.50 Transfer current ≤ 40 mA

■ 4-20 mA isolator Transfer Characteristics


■ Single-channel Calibrated accuracy ±20 µA for 1 kΩ load @ 20ºC
(includes linearity and hysteresis)
■ Loop powered
Temperature drift ≤ 2 µA / ºC
The KFD0-CS-1.50 current repeater is a Response time ≤ 5 ms (@ 4-20 mA and Vin < 26 V)
fully floating isolator for standard 4-20 mA Isolation 2500 VDC
instruments. The inputs are galvanically
isolated from the outputs. Typical Mechanical
applications include driving I/P converters Housing:
and isolating 2-wire transmitters. Material Makrolon
OPERATION: Style KF style (see page 387)
Mounting 35mm DIN rail or surface mount
The KFD0-CS-1.50 is a single-channel Dimensions (mm) 115 x 20 x 118
device that does not require a separate
Weight 100 g (3.5 oz.)
power supply. Due to the 24 VDC input
voltage limitation and the internal voltage
Ambient Temperature -20ºC to +60ºC (-4ºF to +140ºF)
Signal Conditioners

drop, the maximum output voltage under


load is 23 VDC. The maximum internal
resistance is 230 ohms. At input voltages
greater than 26.1 V, the internal voltage
drop is lower than with input voltages
below 26.1 V.
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFD0-CS-1.50

(+) 11 1 (+)
Input Output
(– ) 12 2 (–)

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


140 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Current


Power Supply Loop powered (not intrinsically safe) Repeater/Driver
Nominal voltage 12-35 VDC
Dual Channel Isolator
Input Terminals 11+, 12- ; 8+, 9+, 10-
Input voltage (Vin) 10-35 VDC
Input current (Uin) 4-20 mA

Power Dissipation
@ 25 mA (Vin < 26.1 V) < 150 mW
@ 25 mA (Vin > 26.1 V) < 400 mW

Output Terminals 1+, 2-; 4+, 5-


Output voltage:
10 V < Vin < 26.1 V 0.9 x Vin - (0.23 x current in mA) - 0.7
Vin > 26.1 V 23 V - (0.23 x current in mA)
Output current 4-20 mA
Short circuit current ≤ 65 mA @ Vin>26.1 V
Model Number
Transfer current ≤ 40 mA KFD0-CS-2.50

Transfer Characteristics ■ 4-20 mA isolator


Calibrated accuracy ±20 µA for 1 kΩ load @ 20ºC ■ Dual-channel
(includes linearity and hysteresis)
■ Loop powered
Temperature drift ≤ 2 µA / ºC
Response time ≤ 5 ms (@ 4-20 mA and Vin < 26 V) The KFD0-CS-2.50 current repeater is a
Isolation 2500 VDC fully floating isolator for standard 4-20 mA
instruments. Each channel works as a DC
Mechanical isolator with the inputs galvanically isolated
Housing:
from the outputs. Typical applications
include driving I/P converters and isolating
Material Makrolon
2-wire transmitters.
Style KF style (see page 387)
Mounting 35mm DIN rail or surface mount OPERATION:
Dimensions (mm) 115 x 20 x 118
The KFD0-CS-2.50 is a dual-channel
Weight 100 g (3.5 oz.)
device that does not require a separate
power supply. Due to the 24 VDC input
Ambient Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Signal Conditioners
voltage limitation and the internal voltage
drop, the maximum output voltage under
load is 23 VDC. The maximum internal
resistance is 230 ohms. At input voltages
greater than 26.1 V, the internal voltage
drop is lower than with input voltages
Note: For information about programming, below 26.1 V.
refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFD0-CS-2.50

(+) 11 1 (+)
Input 1 Output 1
(– ) 12 2 (– )

(+) 9 4 (+)
Output 2
Input 2 (– ) 10 5 (– )

(+) 8

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 141
2002 IS Catalog

Current/Voltage Technical Data


Converter Single Power Supply Loop powered (not intrinsically safe)
Nominal voltage 12-35 VDC
Channel Isolator
Input (selectable) Terminals 1+, 2-
Input 0-20 mA
Current load ≤ 50 Ω
Input voltage (Vin) 0-10 VDC
Voltage load ≤ 100 kΩ

Output Terminals 9+, 8-


Output 4-20 mA
Burnout fault signal Downscaled ≤ 3 mA
Load/Ohm (Us - 12 V) / 0.02 A

Transfer Characteristics
Voltage surge 6.5 ppm / V
Model Number Calibrated accuracy ±0.1% of final value @ 20ºC
KFD0-CC-1 Linearity fault ≤ 0.04% of final value
Temperature drift 0.050% of range / ºC
■ Field selectable voltage or 0.060% of span / ºC
current input Response time ≤ 250 ms
Galvanic Isolation safe isolated per DIN VDE 01061
■ Loop-powered
design isolation voltage 253 VEff
■ Isolation of input/output
The KFD0-CC-1 loop powered, 2-wire Mechanical
isolator that converts 2-wire voltage/ Housing:
current signals to a 4-20 mA signal. Material Makrolon
Style KF housing (see page 387)
The KFD0-CC-1 provides galvanic
Mounting 35mm DIN rail or surface mount
isolation for the loop. The required input
Dimensions (mm) 115 x 20 x 118
range is set by a switch on the side of the
unit. Zero and span adjustment are Weight 100 g (3.5 oz.)
achieved by potentiometers on the top of Protection (IEC) IP20
the isolator.
OperatingTemperature -20ºC to +60ºC (-4ºF to +140ºF)
Signal Conditioners

Note: For information about programming,


refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFD0-CC-1

(+) 1 9 (+)
Input Output
(– ) 2 8 (– )

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


142 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Voltage to Current


Power Supply Loop powered (not intrinsically safe) Converter Single
Nominal voltage 12-35 VDC
Channel Isolator
Input Terminals 1+, 3-
Input voltage -50 to + 50 mV
Input current Input monitoring on ≤ 15 nA
Input monitoring off ≤ 1 nA

Output Terminals 9+, 8-


Output 4-20 mA
Lead breakage enabled: ≤ 3 mA; disabled: ≥ 22 mA

Transfer Characteristics
Sensing range - 50 mV to +50 mV
Zero point 1% of final value
Span ± 3.5% of final value
Temperature drift Zero point 0.01% of the span / ºC or Model Number
±1 µV / ºC (whichever is larger) KFD0-VC-1.50m
Span 0.005% of span / ºC
Response time ≤ 250 ms ■ -50 mV to + 50 mV voltage in
Galvanic isolation safe isolated per DIN VDE 01061 current output isolator
design isolation voltage 253 VEff ■ Loop powered
■ Lead breakage monitoring
Mechanical
Housing: The KFD0-VC-1.50m receives a -50 to
Material Makrolon +50 mV signal input and produces a 4-20
Style KF housing (see page 387) mA output. This loop powered module also
Mounting 35mm DIN rail or surface mount provides galvanic isolation.
Dimensions (mm) 115 x 20 x 118 The sensing range of the bipolar input unit
Weight 100 g (3.5 oz.) isolates and conditions a 4-20 mA output.
Protection (IEC) IP20 Fine adjustment for zero and span are
performed with the potentiometer on top
Ambient Temperature -20ºC to +60ºC (-4ºF to +149ºF) of the unit.
Optional lead monitoring is available by the

Signal Conditioners
field configurable DIP switches. Enabling
this feature produces an output ≤ 3 mA
when the input wire is broken, while
disabling produces an output ≥ 22 mA.

Note: For information about programming,


refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFD0-VC-1.50m

(+) 1 9 (+)
Input Output
(– ) 3 8 (– )

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 143
2002 IS Catalog

Voltage to Current Technical Data


Converter Single Power Supply Loop powered (not intrinsically safe)
Nominal voltage 12-35 VDC
Channel Isolator
Input Terminals 1+, 2-
Input -10 to +10 V
Load ≥ 100 kΩ

Output Terminals 9+, 8-


Output 4-20 mA, ≤ 35 mA
Load (Ohm) ≤ (power supply - 12 V) / 0.02 A

Transfer Characteristics
Operating voltage 6.5 ppm / V
Calibrated accuracy 0.1% of final value
Linearity faults ≤ 0.04% of final value
Sensing range -10 V to +10 V
Span ± 1.5% of final value
Model Number Zero point ±1% of final value
Temperature drift Span 0.005% of span / ºC
KFD0-VC-1.10
Zero point 0.060% of span / ºC
Response time 250 ms
■ -10 to +10 voltage input/4-20
Galvanic isolation Function isolation per EN 50178
mA output
design isolation voltage 253 Veff
■ Loop powered
Mechanical
■ Isolation of input/output Housing
The KFD0-VC-1.10 receives a -10 to +10 Material Makrolon
voltage input and produces a 4-20 mA Style KF housing (see page 387)
signal output. This loop powered module Dimensions (mm) 115 x 20 x 118
also provides galvanic isolation. Weight 100 g (3.5 oz.)
The sensing range of the bipolar input unit Protection IP20
isolates and conditions a 4-20 mA output. Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
Fine adjustment for zero and span are
performed with the potentiometer on top
of the unit.
Signal Conditioners

Note: For information about programming,


refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFD0-VC-1.10

(+) 1 9 (+)
Input Output
(– ) 2 8 (– )

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


144 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Thermocouple/


Power Supply Loop powered (not intrinsically safe) mV Input Single
Nominal voltage 12-35 VDC

Input Terminals 1+, 2-, 3-


Channel Isolator
Thermocouple (terminals 1,2,3) E,J,K, N,R,S or T (CJC reference to 0ºC)
Input current Input monitoring ‘ON’ ≤ 15 nA
Input monitoring ‘OFF’ ≤ 1 nA

Output Terminals 9+, 8-


Output 4-20 mA, ≤ 35 mA
Lead breakage Downscaled ≤ 3 mA
Upscaled > 22 mA
Load (power supply - 12 V) / 0.02 A

Transfer Characteristics
Voltage surge 6.5 ppm / V
Measuring range (adjustable) Span 4 to 60 mV
Zero point -12 to 60 mV Model Number
Characteristics Output voltage is proportional to input KFD0-TT-1
Calibrated accuracy 0.1% of final value ±1ºC for cold point
Temperature drift Span 0.005% of span / ºC ■ Internal CJC
Zero point 0.01% of span / ºC or ±1µV/ºC
■ Loop powered
0.01% of span/ºC or ±0.03ºC/ºC (J,K,N,T,E)
0.01% of span/ºC or ±0.06ºC/ºC (R, S) ■ Lead breakage and short circuit
Cold point ±2.0ºC (calibrated at TA = 20ºC) monitoring
Response time ≤ 250 ms ■ Input/output isolation
Galvanic isolation Function isolation per EN50178
■ Field-selectable thermocouple inputs
design isolation voltage 253 Veff
The KFD0-TT-1 is a loop powered isolator
Mechanical that accepts thermocouple inputs and
Housing conditions to a 4-20 mA output.
Material Makrolon
Style KF housing (see page 387) Types E, J, K, N, R, S, and T thermocouple
Dimensions (mm) 115 x 20 x 118
inputs with internal cold junction
compensation (CJC) with galvanic
Weight 150 g (5.3 oz.)
isolation. The input voltage is linear to
Protection IP20
output current, not proportional to

Signal Conditioners
Operating Temperature -20ºC to +60ºC (-4ºF to +149ºF) temperature. Adjustable zero, span and
burnout detection are field-configurable.

Note: For information about programming,


refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFD0-TT-1

(+) 1
8 (– )
(+) 1
(+) 1 8 (– )
Output
Input (– ) 2 9 (+)

(– ) 3

(– ) 2 9 (+)
Input for Passive Output
(– ) 3
Thermocouple

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 145
2002 IS Catalog

RTD Input Technical Data


Single Channel Power Supply Loop powered (not intrinsically safe)
Nominal voltage 12-35 VDC
Isolator
Input Terminals 1+, 2-, 3+
Input PT100, 2- and 3-wire connection
Lead resistance ≤ 100 Ω / lead
Test current ≈ 1 mA

Output Terminals 9+, 8-


Output 4-20 mA (35 mA max.)
Lead breakage Upscaled ≥ 22 mA
Load (Ohm) ≤ (power supply - 12 V) / 0.02 A

Transfer Characteristics
Voltage surge 6.5 ppm / V
Measuring range Span w/o linearization 25ºC to 800ºC
Span with linearization 25ºC to 430ºC
Model Number Zero point w/o linearization -200ºC to 466ºC
Zero point with linearization -86ºC to 405ºC
KFD0-TR-1
Calibrated accuracy 0.1% of final accuracy
Linearity fault w/o linearization ≤ 0.04% final value
■ Loop powered
with linearization ≤ 0.14% final value
■ PT100, 2- and 3-wire Temperature drift span and zero point 0.015% / ºC or
■ Lead breakage (LB) monitoring ± 10 mΩ / ºC
■ Input/output isolation Response time ≤ 250 ms
Galvanic isolation Function isolation per EN50178
■ Field-configurable inputs/outputs design isolation voltage 50 Veff
The KFD0-TR-1 is a loop powered isolator
Mechanical
that accepts Pt100 2- and 3-wire inputs and
Housing
conditions them to a 4-20 mA output.
Material Makrolon
The KFD0-TR-1 provides galvanic isolation Style KF housing (see page 387)
and burnout detection (≥22 mA). Field- Dimensions (mm) 115 x 20 x 100 mm
configurable DIP switches allow linearization Weight 150 g (5.3 oz.)
to be turned on and off. Protection (IEC) IP20
The loop powered 2-wire converter is suited
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
for the connection of the Pt100 in 2- or 3-
Signal Conditioners

wire mode.

Note: For information about programming, refer to page 209


or to our website at www.am.pepperl-fuchs.com
Connection Diagram

KFD0-TR-1

(– ) 2 (– ) 2 8 (– )

(– ) 2 (– ) 2 8 (– )
Output
Input 1 1 1 9 (+)

(+) 3
9 (+)
Passive Ouput
(+) 3 (+) 3
Input for Pt100

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


146 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data DC Current Input


Power Supply Terminals 11+, 12- or Power Rail Current/Voltage
Nominal voltage 9-30 VDC (unregulated acceptable)
Power consumption ≤ 1.5 W, 1 W typical Output Isolator
Inrush current ≤ 200 mA

Input Terminals 1+, 2-


Input span 1-100 mA
Overload ≤ 170 mA, 60 VDC on input
Impedance 20 Ω typical
Zero 50% of full scale input
Span 50% of full scale input

Output Terminals 7-, 8+


Voltage output 0-5 V, 0-10 V
Impedance < 10 Ω
Drive ≤ 10 mA
Current Output 0-1 mA, 0-20 mA, 4-20 mA
Impedance > 100 kΩ Model Number
0-1 mA 7.5 V, max. 7.5 kΩ
0/4-20 mA 12 V, max 600 Ω
KFDX-DCI

Transfer Characteristics ■ Field configurable inputs and


Accuracy (including linearity and hysteresis) outputs
2 mA range ± 0.35% of full scale; 0.5% max. ■ Wide range of DC current inputs
other ranges ± 1.0% of full scale; 0.2% max.
■ 3-way isolation
stability ± 0.025% of full scale / ºC for zero span
Isolation 3-way, 1800 VDC ■ Accepts bipolar inputs
Common mode rejection DC to 60 Hz: 120 dB
The KFDX-DCI accepts a DC current input
Response time 200 ms, 400 ms max.
and provides a fully isolated proportional
Mechanical current or voltage output. In order to eliminate
Housing ground loops, the I/O channel is optically
Material Makrolon isolated to 1800 VDC and transformer
Style KF housing (see page 387) isolated from the power supply.
Dimensions (mm) 115 x 20 x 100 mm The input can be configured in the field for
Weight 3.5 oz. (100 g) one of six current ranges from 1-100 mA.
Protection (IEC) IP 20 Output is linear to the input, configurable for

Signal Conditioners
five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20 mA
Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
or 4-20 mA. The KFDX-DCI accepts bipolar
inputs and offers selectable normal or reverse
output modes of operation (4-20 mA, 20-4
mA). For inputs that do not change in polarity,
select unipolar operation.
Note: For information about programming, refer to page
209 or to our website at www.am.pepperl-fuchs.com The KFDX-DCI is equipped with a dual
function power/signal status LED. When the
Connection Diagram unit is powered, this green LED turns on.
When the input signal is over 110% of the
full scale range, the LED flashes at 8 Hz;
below 0% it flashes at 4 Hz.
KFDX-DCI
This unit is not intrinsically safe.

(+) 1 8 (+)
DC Current Analog
Input 7 (– ) Output
(– ) 2

11 (+)
DC Power
12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 147
2002 IS Catalog

DC Voltage Input Technical Data


Current/Voltage Power Supply Terminals 11+ and 12- or Power Rail
Nominal voltage 9-30 VDC (unregulated acceptable)
Output Isolator Power consumption ≤ 1.5 W, 1 W typical

Input Terminals 1+, 2-


Voltage 10 mV to 100 V
Maximum overload 200 VDC
Impedance ≥ 100 kΩ typical
Zero 50% of full scale input
Span 50% of full scale input

Output Terminals 7-, 8+


Type Selectable DC current or voltage
Voltage output 0-5 V, 0-10 V
Impedance < 10 kΩ
Drive 10 mA, max.
Current output 0-1 mA, 4-20 mA, 0-20 mA
Model Number Impedance > 100 kΩ
KFDX-DCV 0-1 mA 7.5 V, max. 7.5 kΩ
0/4-20 mA 12 V, max. 600 Ω
■ Field-configurable inputs/outputs
Transfer Characteristics
■ 3-way isolators
Accuracy (all ranges) ± 0.1% of full scale: 0.2% max.
■ Accepts bipolar inputs Stability ± 0.025% of full scale / ºC max.
■ Wide range of DC voltage inputs Response time ≤ 400 ms, 200 ms typical
Isolation 3-way, 1800 VDC
The KFDX-DCV accepts a DC voltage input
and provides a fully isolated proportional Common mode rejection DC to 60 Hz, 120 dB
current or voltage output. In order to eliminate Mechanical
ground loops, the I/O channel is optically Housing
isolated to 1,800 VDC and transformer
Material Makrolon
isolated from the power supply.
Style KF housing (see page 387)
The input can be configured in the field for Dimensions (mm) 115 x 20 x 100 mm
one of twelve voltage ranges from 10 mV to Weight 100 g (3.5 oz.)
100V. Output is linear to the input, configurable Protection (IEC) IP20
for five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20
mA, or 4-20 mA. The KFDX-DCV accepts Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
Signal Conditioners

bipolar inputs and offers selectable normal or


reverse modes of operation (4-20 mA, 20-4
mA). For inputs which do not change in
polarity, select unipolar operation.
The KFDX-DCV is outfitted with a dual function
Note: For information about programming, refer to page
power/signal status LED. When the unit is
209 or to our website at www.am.pepperl-fuchs.com
powered, this green LED turns on. When the
input signal is over 110% of the full scale Connection Diagram
range, the LED flashes at 8 Hz.
This unit is not intrinsically safe KFDX-DCV

(+) 1 8 (+)
DC Voltage Analog
Input 7 (– ) Output
(– ) 2

11 (+)
DC Power
12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


148 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data 2- and 3-wire Transmitter


Power Supply Terminals 11+, 12- or Power Rail Input 4-20 mA Current
Nominal voltage 20-35 VDC
Power consumption ≤ 1.7 W
Output Isolator
Input Terminals 1+, 2-, 3
Available voltage 2-wire: 17.5 V at 20 mA
3-wire: 16.5 V at 25 mA
Input load (terminals 2, 3) 20 Ω

Output (not intrinsically safe) Terminals 7-, 8+, 9-


Output signal 0-20 mA
Available voltage 20 VDC
Load ≤ 1 kΩ

Transfer Characteristics
Accuracy @ 20ºC ≤ ±10 µA
Temperature drift ≤ ±0.2 mA / ºC (0ºC to +60ºC) Model Number
±1.0 mA / ºC (-20ºC to 0ºC) KFD2-CR-1.300
Response time ≤ 50 µs
Galvanic isolation, 3 way Isolation per EN50178 ■ 2- or 3-wire input
Isolation voltage 253 Veff ■ 20-30 VDC power supply
Mechanical ■ 4-20 mA output
Housing ■ 3-way isolation
Material Makrolon
The KFD2-CR-1.300 is an isolator that
Style KF Housing (see page 387)
powers and repeats a 4-20 mA signal from
Dimensions (mm) 115 x 20 x 100 mm
a 2- or 3-wire transmitter. It can also isolate
Weight 100 g (3.5 oz.)
and repeat signals from a current source.
Protection (IEC) IP20
For 2-wire transmitters, connected to
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF) terminals 1 and 3, there is 17.5 V at 20 mA
available to the transmitter.
For 3-wire transmitters, the power is supplied
on terminals 1 and 2 with a 4-20 mA signal
flowing into terminal 3. The voltage available

Signal Conditioners
is approximately 16.5 V at 25 mA between
terminals 1 and 2. Power, input and output
are galvanically isolated.
This unit is not intrinsically safe.
For information about programming, refer to page 209 or to our website
at www.am.pepperl-fuchs.com
Connection Diagram

KFD2-CR-1.300

(+) 1 (+) 1
(– ) 2
(+) 1 8 (+)
(– ) 2 Analog
(– ) 2 7 (– )
Output
3 9 (– )
3
11 (+) DC Power
12 (–) Supply
3 3
Input

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 149
2002 IS Catalog

Current/Voltage Technical Data


Driver Current Power Supply Terminals 7+, 8- or Power Rail
Supply voltage 20-35 VDC
Output Isolator Nominal current current output ≤ 50 mA
Nominal current voltage output ≤ 20 mA

Input Terminals 9+, 10-, 11+


Current input Voltage Input
Transmission range 0-20 mA 0-10 V
Max. input current 40 mA N/A
Max. input voltage 35 V 12 VDC
Voltage drop ≤ 4 V at 20 mA N/A
Input current N/A ≤10 µA to 50ºC w/ 10 V

Output Terminals 1+, 2-


Current 0-20 mA
Voltage 17 V at 20 mA
Model Number Load resistance ≤ 850 Ω
KFD2-CD-1.32
Transfer Characteristics
■ Current or voltage input options Calibrated accuracy @ 20ºC ±0.01% inc. nonlinearity and hysteresis
■ 20-30 VAC power supply Temperature drift per ºC ±0.01%
Response time < 10 ms
■ 3-way isolation Galvanic isolation Isolation per EN50178
The KFD2-CD-1.32 provides three-way Isolation voltage 253 Veff
isolation and is used for driving I/P converters,
electrically operated valves and positioners. Mechanical
The KFD2-CD-1.32 is available in several Housing
versions. Material Makrolon
CURRENT INPUT OPTION Style KF Housing (see page 387)
Current flowing into terminals 10 and 11(9) Dimensions (mm) 115 x 20 x 100 mm
passes through resistor Internal Load, Weight 100 g (3.5 oz.)
generating a voltage that is transferred to the Protection (IEC) IP20
DC/DC converter. A current limit circuit in line
with terminal 9 protects Rm from damage. The Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
maximum voltage drop across the input is only
Signal Conditioners

4 V at 20 mA, allowing the connection of


several KFD2-CD-1.32 input circuits in series.
VOLTAGE INPUT OPTION
Voltage within the specified input range is
transferred to terminals 9 and 10 via an
Note: For information about programming, refer to page 209 or to our
amplifier and a DC/DC converter. A voltage
website at www.am.pepperl-fuchs.com
limiter circuit protects the amplifier from
incorrect input switching and overvoltage, but Connection Diagram
will draw current through a 50 mA fuse during
operation.
CURRENT OUTPUT OPTION KFD2-CD-1.32
Voltage transferred across the DC/DC KFD2-CD-1.32-2
KFD2-CD-1.32-8
converter provides a proportional current at
terminals 1 and 2. For all supply voltages, there (+) 9 (+) 9
is a minimum of 17 V at 20 mA to drive loads
(+) 11
of up to 850 Ω. (+) 9
1 (+) Analog
2 (– ) Output
This unit is not intrinsically safe. (– ) 10
(– ) 10 (– ) 10
7 (+)
KFD2-CD-1.32: 0/4 to 20mA input / output Input DC Power
8 (– ) Supply
KFD2-CD-1.32-2: 0-20mA input / 4-20mA output
KFD2-CD-1.32-8: 0-10V input / 4-20mA output

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


150 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Single Input/Dual


Power Supply Terminals 14+, 15- or Power Rail Output Transmitter/
Nominal voltage 20-32 VDC
Power consumption ≈ 2.5 W Repeater Isolator
Input Terminals 1, 2, and 3
Input signal 0-20 mA
Available voltage ≥ 16 V at 20 mA
Input resistance ≤ 85 Ω

Output Terminals 7-, 8+; 10-, 11+


Output signal 0-20 mA
Load 0-550 Ω

Transfer Characteristics
Calibration accuracy ≤ ±20 µA
Temperature drift ≤ 20 ppm / ºC
Rise time 20 µs with 4-20 mA stage Model Number
De-energized delay 20 µs with 20-4 mA stage KFD2-CR4-1.20
Galvanic isolation, 3-way Isolation per EN50178
Isolation Voltage 253 Veff ■ Single-channel input /
dual output
Mechanical ■ 20-30 VDC supply voltage
Housing
Material Makrolon
■ Outputs isolated from each other
Style KF housing (see page 387) ■ Power Rail Bus
Dimensions (mm) 115 x 20 x 100 mm ■ 3-way isolation
Weight 100 g (3.5 oz.)
Protection (IEC) IP20 The KFD2-CR4-1.20 is suited for the
connection of 2- and 3-wire transmitters.
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF) It may also be employed as a repeater for
0-20 mA signals (current source).
Both outputs provide a 0-20 mA current
corresponding to the input signal.
2-wire transmitters are connected to

Signal Conditioners
terminals 1 and 3. The input for the signal
is terminal 3. The minimum available
voltage is 16V at 20 mA. Current sources
are connected to terminals 2 and 3.
The input, output and power supply are
Note: For information about programming, refer to page 209 or to our galvanically isolated from each other.
website at www.am.pepperl-fuchs.com
This unit is not intrinsically safe.
Connection Diagram

KFD2-CR4-1.20

(+) 1 (+) 1

(+) 1 7 (– )
(– ) 2 Output 1
8 (+)
(– ) 2
10 (– )
(– ) 2 3 Output 2
11 (+)
14 (+)
DC Power
3 3 3 15 (– ) Supply
Input

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 151
2002 IS Catalog

HART Transmitter Technical Data


Power Supply Power Supply Power Rail or terminals 14+, 15-
Nominal voltage 20-32 VDC
Isolator Power consumption ≈2.5 W

Input Terminals 1, 2, 3
Input signal 0/4-20 mA
Available voltage at 20 mA ≥16 V

Output Terminals 9+, 10-, 11+


Output signal 4-20 mA / load 550 Ω
Ripple ≤ 50 µArms

Transfer Characteristics
Calibrated accuracy ≤ 20 µA
Temperature drift ≤ 20 ppm / ºC
Frequency range:
Input/Output:
Model Number Band width at 0.5 VppSignal 0 Hz to 7.5 kHz (-3 dB)
KFD2-STC4-1.20 Output/Input:
Band width at 0.5 VppSignal 300 Hz to 7.5 kHz (-3 dB)
■ Single channel input /dual output Galvanic isolation Isolation per EN 50178
Isolation voltage 253 Veff
■ HART compatible
■ 4-20mA current source output Mechanical
■ 3-way isolation Housing
Material Makrolon
SMART transmitter powers a 2-wire Style KF housing (see page 387)
SMART transmitter and isolates the analog Dimensions (mm) 107 x 20 x 115 mm
4-20 mA signal from the field to the control Weight 100 g (3.5 oz.)
room as two current sources. Protection (IEC) IP20
Digital signals which can be modulated onto
the analog signal, can also be transmitted Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
bidirectionally.
The SMART transmitters are delivered with
the KF-STP-GN terminals. Connector jacks
are integrated in these terminals for the
Signal Conditioners

connection of the handheld terminals.


This unit is not intrinsically safe.

Note: For information about programming, refer to page 209 or to our


website at www.am.pepperl-fuchs.com
Connection Diagram

KFD2-STC4-1.20

(+) 1 (+) 1
Communicator

(+) 1 7 (– )
(– ) 2 (– ) 2
SMART

Output 1
8 (+)
(– ) 2
10 (– )
3 Output 2
11 (+)
14 (+)
3 3 3 DC Power
15 (– ) Supply
Input

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


152 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data RTD Input


Power Supply Terminals 11+, 12- or Power Rail Current/Voltage
Supply voltage
Power consumption
9-30 VDC
≤ 2.5 W, 1.5 W typical
Output Isolator
Inrush current ≤ 300 mA

Input Terminals 1+, 2-, 3


Excitation current < 2 mA
Zero 50% of full scale input
Span 50% of full scale input

Output Terminals 7-, 8+


Voltage output 0-5 V, 0-10 V
Impedance > 10 Ω
Drive ≤ 10 mA
Current output 0-1 mA, 0-20 mA, 4-20 mA
Impedance > 100 kΩ
0-1 mA 7.5 V, max. 7.5 kΩ Model Number
0/4-20 mA 12 V, max. 600 Ω KFDX-RTD
Accuracy (including linearity & hysteresis)
±0.01% typical, 0.2% max. of the max. ■ Field selectable inputs/ outputs
input range @ 25ºC, 0Ω lead resistance ■ Wide range of RTD inputs
Temperature drift ±0.015% of max. temperature range/ºC
Response time ≤ 500 ms, 250 ms typical
■ 3-way isolation
Isolation 3-way 1800 VDC ■ Lead resistance compensation
The KFDX-RTD isolator interfaces 3-wire RTDs
Mechanical
(Pt100, Pt500, Pt1000, Cu10, Cu25 and
Housing Cu100) to a process control system. This
Material Makrolon isolator also effectively eliminates ground loops
Style KF housing (see page 387) with 1800 VDC isolation separating input,
Dimensions (mm) 115 x 20 x 100 mm output and power supply.
Weight 100 g (3.5 oz.)
The input range can be configured in the field
Protection (IEC) IP20
for one of sixteen temperature ranges via DIP
switches. The output is linear to temperature,
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
configurable for five ranges: 0-5 V, 0-10 V, 0-

Signal Conditioners
1 mA, 0-20 mA or 4-20 mA.
Span and zero potentiometers provide 50%
adjustability of offset and span turndown for
each input range. To ensure accurate
temperature measurement, the KFDX-RTD
Note: For information about programming, refer to page 209 or to our contains constant current circuitry which uses
website at www.am.pepperl-fuchs.com
the third lead of the RTD as a sense line for
lead resistance compensation.
Connection Diagram
The KFDX-RTD is equipped with three LEDs:
INPUT (green), TROUBLE (yellow) and CAL
KFDX-RTD (yellow). Upon power-up, the INPUT and CAL
LEDs will alternately flash for 10 seconds.
This unit is not intrinsically safe.

(+) 1
8 (+)
(– ) 2 Analog
7 (– ) Output
(R) 3
RTD Input 11 (+)
DC Power
12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 153
2002 IS Catalog

Thermocouple Technical Data

Input Isolator Power Supply


Supply voltage
Terminals 11+ and 12- or Power Rail
9-30 VDC (unregulated acceptable)
Power consumption ≤ 2.5 W, 1.5 W typical

Input Terminals 1, 2
Maximum overload ± 10 VDC on input
Range selectable
Impedance ≥ 1 MΩ
Burnout detection selectable up/downscale
Zero 50% of full scale input
Span 50% of full scale input

Output Terminals 7-, 8+


Voltage output 0-5 V, 0-10 V
Line impedance > 10 Ω
Drive ≤ 10 mA
Current output 0-1 mA, 0-20 mA, 4-20 mA
Model Number Impedance > 100 kΩ
KFDX-TC 0-1 mA 7.5 V, max. 7.5 kΩ
0/4-20 mA 12V, max. 600 Ω
■ Wide range of thermocouple types
Transfer characteristics
■ Cold junction compensation (CJC) Temperature drift < ±0.04% of max. input temperature
■ 24 VDC supply voltage per ºC change in ambient temperature
■ 3-way isolation Common mode rejection DC to 60 Hz: 120 dB
Isolation 3-way, 1,800 VDC
The KFDX-TC thermocouple input isolator Response time ≤ 750 ms, 400 ms typical
interfaces B, E, J, K, R, S and T type
thermocouples to a process control system. Mechanical
It also effectively eliminates ground loops with Housing
1,800 VDC isolation separating input, output Material Makrolon
and power supply. Style KF housing (see page 387)
Dimensions (mm) 115 x 20 x 100 mm
The input range can be configured in the field Weight 100 g (3.5 oz.)
for one of 16 thermocouple temperature
Protection (IEC) IP20
ranges via DIP switches on the side of the
housing. The output is linear to temperature, Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
Signal Conditioners

configurable for five ranges: 0-5 V, 0-10 V, 0-


1 mA, 0-20 mA, or 4-20 mA.
Span and zero potentiometers on the top plate
provide 50% adjustability of offset and span
turn-down for each input range. The KFDX-
TC also features internal cold junction Note: For information about programming, refer to page 209
compensation (CJC) and selectable or to our website at www.am.pepperl-fuchs.com
upscale /downscale thermocouple burnout
detection.
Connection Diagram
The KFDX-TC is outfitted with three LEDs on
the front panel: INPUT (Green), TROUBLE KFDX-TC
(Yellow), and CAL (Yellow). Upon power-up,
the INPUT and CAL LEDs alternately flash for
10 seconds.
This unit is not intrinsically safe. (+) 1
8 (+)
Analog
7 (– ) Output
(– ) 2
Thermocouple 11 (+)
DC Power
Input 12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


154 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Universal


Temperatur e
Power Supply Terminals 11+, 12- or Power Rail
Supply voltage 20-35 VDC Input Isolator
Power consumption ≈ 1.5 W

Input Terminals 1-, 2-, 3+, 4+


Thermocouple B,E,J,K,L,N,R,S or T
Lead resistance ≤ 50 Ω per lead
Test current 400 µA with RTDs

Output Terminals 7-, 8+


Output current 4-20 mA (20.5 mA at input signal exceeded)
Fault signal Downscaled 2-4 mA, upscaled 20.522 mA
Load ≤ 500 Ω

Transfer Characteristics
Calibrated accuracy ± (0.01% of value in ºC + 0.05% of
Model Number
range + 0.1 ºC) (4-wire)
Thermocouple ± (0.05% of value in ºC + 0.05% of
KFD2-UT-1
range + 1ºC) (inc. ± 0.8ºC error for CJC)
■ Universal temperature inputs
Rise time ≤ 430 ms
Galvanic isolation Isolation per EN50178 ■ Current output
Isolation voltage 253 Veff ■ Programming & calibration via PC
Mechanical ■ 3-way isolation
Housing ■ CJC for thermocouple and lead
Material Makrolon resistance compensation for RTDs
Style KF housing (see page 387)
The KFD2-UT-1 is designed for connection to
Dimensions (mm) 115 x 20 x 118
RTDs (Pt100 and Ni100) or thermocouples (B, E,
Weight 100 g (3.5 oz.)
J, K, L, N, R, S and T), and provides three-way
Protection (IEC) IP20
isolation. The inputs, outputs and power supply
Operating Temperature +4ºC to +60ºC (+40ºF to +140ºF) are galvanically isolated.

This device also features internal/external cold


junction compensation, burnout monitoring for
thermocouples and burnout and short circuit

Signal Conditioners
monitoring for RTDs.

All settings are programmed and calibrated


through a serial interface to PC (on-line
programming--see the P+F web site for more
information).
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com A signal at terminals 2 and 3 is transmitted across
the isolator and converted to an equivalent output
Connection Diagram at terminals 7 and 8. Terminal 7 has the same
polarity as terminal 2.
KFD2-UT-1
All parameters are programmable through a K-
CJC
(+) 4 ADP1 cable (sold separately) that provides the
Type K-CJC-GN connection between the programming socket of
(+) 3 (+) 3 (+) 3
7 (+) Analog
the KFD2-UT and the RS232 PC interface.
4 Output
8 (– )
3 Accessories include removable terminals with
(– ) 2
2 internal cold junction compensation (K-CJC) and
(– ) 2 (– ) 2 (– ) 2 11 (+) DC
1 Power
a K-SK programming software kit. The K-ADP1
12 (– )
Supply and K-SK are required unless the KFD2-UT is
(+) 1 (– ) 1 (– ) 1
configured by P+F.
Input

This unit is not intrinsically safe.


PC

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 155
2002 IS Catalog

Universal Technical Data


Temperature Power Supply Terminals 11+, 12- or Power Rail
Supply voltage 20-35 VDC
Input Isolator Power consumption ≈ 1.5 W

Input Terminals 1-, 2-, 3+, 4+


Thermocouple B,E,J,K,L,N,R,S or T
Lead resistance ≤ 50 Ω per lead
Test current 400 µA with RTDs

Output Terminals 7-, 8+


Output voltage 1-5 V; (5.125 V input signal exceeded)
Fault signal Downscaled 0-5 V, upscaled 5.025 - 5.12 V
Load ≤ 10 KΩ

Transfer Characteristics
Calibrated accuracy ± (0.01% of value in ºC + 0.05% of
Model Number
range + 0.1 ºC) (4-wire)
KFD2-UT-1-1 Thermocouple ± (0.05% of value in ºC + 0.05% of
range + 1ºC) (inc. ± 0.8ºC error for CJC)
■ Universal temperature inputs Rise time ≤ 430 ms
■ Voltage output Galvanic isolation Isolation per EN50178
Isolation voltage 253 Veff
■ Programming & calibration via PC
■ 3-way isolation Mechanical
■ CJC for thermocouples and lead Housing
resistance compensation for RTDs Material Makrolon
Style KF housing (see page 387)
The KFD2-UT-1-1 is designed for connection to
Dimensions (mm) 115 x 20 x 118
RTDs (Pt100 and Ni100) or thermocouples (B,
E, J, K, L, N, R, S and T), and provides three- Weight 100 g (3.5 oz.)
way isolation. The inputs, outputs and power Protection (IEC) IP20
supply are galvanically isolated.
Operating Temperature +4ºC to +60ºC (+40ºF to +140ºF)
This device also features internal/external cold
junction compensation, burnout monitoring for
thermocouples and burnout and short circuit
Signal Conditioners

monitoring for RTDs.

All settings are programmed and calibrated


through a serial interface to PC (on-line
programming).

A signal at terminals 2 and 3 is transmitted across Note: For information about programming,
the isolator and converted to an equivalent refer to our website at www.am.pepperl-fuchs.com
output at terminals 7 and 8. Terminal 7 has the
same polarity as terminal 2. Connection Diagram
All parameters are programmable through a K- KFD2-UT-1-1
ADP1 cable (sold separately) that provides the
connection between the programming socket CJC (+) 4
Type K-CJC-GN
of the KFD2-UT and the RS232 PC interface. (+) 3 (+) 3 (+) 3
7 (+) Analog
4
Accessories include removable terminals with 8 (– )
Output
3
internal cold junction compensation (K-CJC) and (– ) 2
2
a K-SK programming software kit. The K-ADP1 (– ) 2 (– ) 2 (– ) 2 11 (+) DC
1
and K-SK are required unless the KFD2-UT-1-1 12 (– )
Power
Supply
is configured by P+F. (+) 1 (– ) 1 (– ) 1

This unit is not intrinsically safe.

PC

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


156 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data AC Current/Voltage


Power Supply Terminals 11+, 12- or Power Rail Input Current/Voltage
Supply voltage 9-30 VDC
Power consumption ≤ 1.5 W, 1 W typical Output Isolator
Input Terminals 1+, 2-
Input voltage / current 100 mV to 250 V / 10-100 mA
Overload ≤ 300 VAC / 170 mA AC (60 Vp for
current inputs)
Impedance ≥ 100 kΩ (voltage inputs) / 20 Ω
(current inputs)
Zero 50% of full scale input
Span 50% of full scale input

Output Terminals 7-, 8+


Voltage 0-5 V, 0-10 V
Impedance < 10 kΩ
Drive ≤ 10 mA
Current 0-1 mA, 4-20 mA, 0-20 mA
Model Number
Impedance > 100 kΩ KFDX-AC
0-1 mA 7.5 V, max. 7.5 kΩ
0/4-20 mA 12 V, max. 600 Ω ■ Wide range of inputs/outputs
■ Field selectable input/output
Transfer Characteristics
Range ± 0.1% of full scale: 0.5% max. ■ 3-way isolation
Stability ± 0.025% of full scale/ºC for zero and span The KFDX-AC accepts an AC voltage/current
Common mode rejection DC to 60 Hz: 120 dB input and provides a fully isolated proportional
Isolation 3-way 1,800 VDC DC current or voltage output. In order to
Response time ≤ 400 ms, 200 ms typical eliminate ground loops, the I/O channel is
optically isolated to 1,800 VDC and
Mechanical
transformer isolated from the power supply.
Housing
Material Makrolon The input can be configured in the field for
Style KF housing (see page 387) one of twelve voltage ranges from 100 mV to
Dimensions (mm) 115 x 20 x 118 250 V and 4 current ranges from 10 mA to
Weight 100 g (3.5 oz.) 100 mA. Output is linear to the input,
configurable for five ranges: 0-5 V, 0-10 V, 0-
Protection (IEC) IP20
1 mA, 0-20 mA, or 4-20 mA.

Signal Conditioners
Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
The KFDX-AC is outfitted with a green dual
function power/signal status LED. When the
unit is powered, the LED is illuminated. When
the input signal is over 110% of the full scale
range, the LED flashes at 8 Hz.
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com This unit is not intrinsically safe.
Connection Diagram

KFDX-AC

(+) 1 8 (+)
AC Input Analog
Current/Voltage (– ) 2 7 (– ) Output

11 (+)
DC Power
12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 157
2002 IS Catalog

Frequency Input Technical Data


Current/Voltage Power Supply Terminals 11+, 12- or Power Rail
Supply voltage 9-30 VDC
Output Isolator Inrush current will not exceed stead state current
Power consumption ≤ 2.5 W, 1.4 W typical

Input Terminals 1+, 2-


Range 2 Hz to 10 KHz, pulse
Input values 150 mVp to 150 Vrms
Overload ≤ 180 Vrms
Impedance ≥ 10 kΩ

Output Terminals 7-, 8+


Voltage output 0-5 V, 0-10 V
Impedance > 1 kΩ
Drive ≤ 10 mA
Current output 0-1 mA, 0-20 mA, 4-20 mA
Impedance ≥ 100 kΩ
Model Number 0-1 mA 7.5 V, max. 7.5 kΩ
KFDX-HZ 0/4-20 mA 12 V, max. 600 Ω

■ Span from 2 Hz to 10,000 Hz Transfer Characteristics


Accuracy ± 0.1% of selected range @ 25ºC
■ Easy push-button calibration Temperature drift ±0.025% / ºC max. of selected range
■ 3-way isolation Power < ±0.01% of max. temp. range/% of
power change
The KFDX-HZ accepts a frequency input
Common mode isolation DC to 60 Hz: 100 dB
and provides a fully isolated proportional
DC current or voltage output. This isolator Isolation 3-way 1,800 VDC
also effectively eliminates ground loops Response time ≤ 500 ms, 250 ms typical
with 1,800 VDC isolation separating input, Mechanical
output and power supply.
Housing
The input range can be configured in the Material Makrolon
field for any frequency span from 2 Hz to Style KF housing (see page 387)
10,000 Hz via DIP switches on the side of Dimensions (mm) 115 x 20 x 118
the housing. The output is configurable for Weight 100 g (3.5 oz.)
five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20 Protection (IEC) IP20
mA, or 4-20 mA.
Signal Conditioners

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)


The KFDX-HZ is simply configured via
push-buttons rather than a zero and span
potentiometer. Set the input frequency
span by applying the maximum and
minmum frequencies to the system and
pressing the CAL button while the INPUT Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com
LED is lit.
The KFDX-HZ is outfitted with three LEDs: Connection Diagram
LEVEL (Green), INPUT (Yellow), and
OUTPUT (Red).
This unit is not intrinsically safe. KFDX-HZ

(+) 1 8 (+)
Frequency Analog
Input (– ) 2 7 (– ) Output

11 (+)
DC Power
12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


158 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Rotational Speed


Power Supply Terminals 23, 24 Limit Alarm
Nominal voltage 120 VAC
Power consumption 2 VA

Input Terminals 1+, 3-


Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Quiescent voltage/short circuit current: 18 V / 5 mA Model Number
Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA KFA5-DWB-1.D
Outputs
■ Operating range 0.06-720,000
Relay output 1 (SPDT) Terminals 10, 11, 12
RPM (0.001-12,000 Hz)
Relay output 2 (SPDT) Terminals 16, 17, 18
Contact load 250 VAC / 2 A / cos ø > 0.7; 40 VDC / 2 A ■ Relay outputs
Mechanical life ≥ 5 x 107 operations ■ Push-button programmable
Energizing / de-energizing ≈ 20 ms / ≈ 20 ms
■ Start-up override
Transfer Characteristics ■ LCD display
Frequency range 0.001-12,000 Hz
■ Lead breakage (LB) and short
Mechanical circuit (SC) monitoring
Housing The KFA5-DWB-1.D monitors for an
Material Makrolon overspeed or underspeed condition by
Style KF housing (see page 387) comparing the input frequency to the user
Dimensions (mm) 118 x 40 x 115 programmed reference frequency. The
Weight 300 g (10.6 oz.) reference frequency is easily programmed
Protection (IEC) IP20 by the use of a keypad located on the front

Signal Conditioners
of the unit. An overspeed or underspeed
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF) condition is signaled via the relay outputs.
Lead breakage and short circuits in the
sensor are indicated by a red LED. The
start-up override feature sets relay outputs
to default conditions programmed by the
Note: For information about programming, user, for up to 1,000 seconds.
refer to our website at www.am.pepperl-fuchs.com
This unit is not intrinsically safe.
Connection Diagram

KFA5-DWB-1.D
Input II Input I 11
10 Output 1
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1
12

17
R2
2 2 16 Output 2
R1
18
R1
13 (+) Start Up
14 (– ) Override
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3
23 Supply
LB/SC LB/SC LB 24 120 VAC

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 159
2002 IS Catalog

Rotational Speed Technical Data


Limit Alarm Power Supply Terminals 23, 24
Nominal voltage 240 VAC
Power consumption 2 VA

Input Terminals 1+, 3-


Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Model Number Quiescent voltage/short circuit current: 18 V / 5 mA
KFA6-DWB-1.D Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

Outputs
■ Operating range 0.06-720,000 Relay output 1 (SPDT) Terminals 10, 11, 12
RPM (0.001-12,000 kHz) Relay output 2 (SPDT) Terminals 16, 17, 18
■ Relay outputs Contact load 250 VAC / 2 A / cos ø > 0.7; 40 VDC / 2 A

■ Push-button programmable Mechanical life ≥ 5 x 107 operations


Energizing / de-energizing ≈ 20 ms / ≈ 20 ms
■ Start-up override
Transfer Characteristics
■ LCD display
Frequency range 0.001-12,000 Hz
■ Lead breakage (LB) and short
circuit (SC) monitoring Mechanical
Housing
The KFA6-DWB-1.D monitors for an Material Makrolon
overspeed or underspeed condition by
Style KF housing (see page 387)
comparing the input frequency to the user
Dimensions (mm) 118 x 40 x 115
programmed reference frequency. The
reference frequency is easily programmed Weight 300 g (10.6 oz.)
by the use of a keypad located on the front Protection (IEC) IP20
Signal Conditioners

of the unit. An overspeed or underspeed Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
condition is signaled via the relay outputs.
Lead breakage and short circuits in the
sensor are indicated by a red LED. The
start-up override feature sets relay outputs
to default conditions programmed by the
Note: For information about programming,
user, for up to 1,000 seconds. refer to our website at www.am.pepperl-fuchs.com
This unit is not intrinsically safe.
Connection Diagram

KFA6-DWB-1.D
Input II Input I 11
10 Output 1
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1 12
Signal Processor

17
R2 16
2 2 Output 2
R1 18
R1
13 (+) Start Up
14 (– ) Override
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 23 Supply
LB/SC LB/SC LB 24 240 VAC

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


160 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Rotational Speed


Power Supply Terminals 23, 24 Limit Alarm
Nominal voltage 20-30 VDC
Power consumption 2W

Input Terminals 1+, 3-


Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Quiescent voltage/short circuit current: 18 V / 5 mA Model Number
Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA KFD2-DWB-1.D
Outputs
Relay output 1 (SPDT) Terminals 10, 11, 12
■ Operating range 0.06-720,000
Relay output 2 (SPDT) Terminals 16, 17, 18
RPM (0.001-12,000 Hz)
Contact load 250 VAC / 2 A / cos ø > 0.7; 40 VDC / 2 A ■ Relay outputs
Mechanical life ≥ 5 x 107 operations ■ Push-button programmable
Energizing / de-energizing ≈ 20 ms / ≈ 20 ms
■ Collective error messaging
Transfer Characteristics ■ LCD display
Frequency range 0.001-12,000 Hz
■ Lead breakage (LB) and short
circuit (SC) monitoring
Mechanical
Housing The KFD2-DWB-1.D monitors for
Material Makrolon overspeed or underspeed conditions by
Style KF housing (see page 387) comparing the input frequency to the user-
Dimensions (mm) 118 x 40 x 115 programmed reference frequency. The
Weight 300 g (10.6 oz.) reference frequency is easily programmed
Protection (IEC) IP20 by push buttons mounted on the front

Signal Conditioners
panel. An overspeed or underspeed
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF) condition is signaled via the relay outputs.
Lead breakage and short circuits in the
sensor are indicated by a red LED and
through the collective error output via
Power Rail. The start-up override feature
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com sets relay outputs to default conditions
programmed by the user, for up to 1,000
Connection Diagram seconds.
This unit is not intrinsically safe.

KFD2-DWB-1.D
Input II Input I 11
10 Output 1
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1 12
Signal Processor

17
R2 16
2 2 Output 2
R1 18
R1
13 (+) Start Up
14 (– ) Override
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 23 (+) Supply
LB/SC LB/SC LB 24 (– ) 24 VDC

Collective Error Messaging

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 161
2002 IS Catalog

Universal Frequency Technical Data


Converter Power Supply Terminals 23, 24
Nominal voltage 20-90 VDC; 40-250 VAC
Power consumption 2.2 W; 3 VA
Input
Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current (Im) max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Quiescent voltage/short circuit current: 18 V / 5 mA
Model Number Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA
KFU8-UFC-1 Outputs
Relay output 1 (SPDT) Terminals 10, 11 and 12
■ 24 VDC / 120 VAC / 240 VAC supply Relay output 2 (SPDT) Terminals 16, 17 and 18
■ Operating range 0.06-720,000 RPM Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2A
(0.001-12,000 kHz) Mechanical life ≥ 5 x 107 operations
Energizing / de-energizing delay ≈ 20 ms / ≈ 20 ms
■ Analog and digital outputs
Output 3 (passive transistor) Terminals 19+ and 20-
■ PC programmable Nominal current 50 mA, short circuit-protected
Logic 1 voltage drop < 2.5 V
This universal frequency converter converts Logic 0 output switched off (leakage < 10 µA)
a digital input signal into an analog output Output 4 (current) Terminals 8+ and 7-
signal for connection to standard current
Open circuit voltage ≤ 24 VDC
input devices. A passive transistor output
Output current 0-20 mA or 4-20 mA
isolates and transfers the digital signal.
Error signal Downscale < 3.6 mA, upscale ≥ 22 mA
Two relay outputs can be programmed to
Load ≤ 650 Ω
actuate at desired frequencies. The unit is
programmable with a PC and the Mechanical
PACTware configuration software. Housing Makrolon KF housing (see page
A debounce filter eliminates extraneous 387)
Signal Conditioners

signals from relay bounce. Dimensions (mm) 118 x 40 x 115


Lead breakage and short circuits in the Weight 300 g (10.6 oz.)
sensor are indicated by a red LED. Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

This unit is not intrinsically safe.


Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com

Connection Diagram

KFU8-UFC-1
Input II Input I 11
RxD 10 Output 1
TxD Programming
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1 12
GND Jack
17
16 Output 2
18
R2
2 2 19 (+) Output 3
R1 20 (– )
R1 8 (+) Output 4
7 (– ) 0/4-20 mA
13 Start Up
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 14 Override
LB/SC LB/SC LB 23 Supply
24 24 VDC
120 VAC
240 VAC

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


162 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Universal Frequency


Power Supply
Nominal voltage
Terminals 23, 24
20-30 VDC
Converter with Display
Power consumption 2.2 W
Input
Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current (Im) max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Quiescent voltage/short circuit current: 18 V / 5 mA
Model Number
Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA
KFD2-UFC-1.D
Outputs
Relay output 1 (SPDT) Terminals 10, 11 and 12 ■ 24 VDC supply
Relay output 2 (SPDT) Terminals 16, 17 and 18
■ Operating range 0.06-720,000
Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2A
RPM (0.001-12,000 kHz)
Mechanical life ≥ 5 x 107 operations
Energizing / de-energizing delay ≈ 20 ms / ≈ 20 ms ■ Analog and digital outputs
Output 3 (passive transistor) Terminals 19+ and 20- ■ PC and push-button
Nominal current 50 mA, short circuit-protected programmable
Logic 1 voltage drop < 2.5 V ■ LCD display
Logic 0 output switched off (leakage < 10 µA)
Output 4 (current) Terminals 8+ and 7- This universal frequency converter converts
Open circuit voltage ≤ 24 VDC a digital input signal into an analog output
Output current 0-20 mA or 4-20 mA signal for connection to standard current
Error signal Downscale < 3.6 mA, upscale ≥ 22 mA input devices. A passive transistor output
Load ≤ 650 Ω isolates and transfers the digital signal. Two
relay outputs can be programmed to
Mechanical actuate at desired frequencies. The units is

Signal Conditioners
Housing Makrolon KF housing (see page 387) programmable with a PC and the
Dimensions (mm) 118 x 40 x 115 PACTware configuration software. A
Weight 300 g (10.6 oz.) debounce circuit eliminates extraneous
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF) signals from relay bounce.
Lead breakage and short circuits in the
Note: For information about programming, sensor are indicated by a red LED and
refer to our website at www.am.pepperl-fuchs.com through the collective error output via
Power Rail.
Connection Diagram
This unit is not intrinsically safe.

KFD2-UFC-1.D
Input II Input I 11
RxD 10 Output 1
TxD Programming
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1 12
GND Jack
17
16 Output 2
R2 18
2 2 19 (+) Output 3
R1 20 (– )
R1 Output 4
8 (+)
7 (– ) 0/4-20 mA
13 (+) Start Up
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 14 (– ) Override
LB/SC LB/SC LB 23 (+)
Supply
24 (– ) 24 VDC

Collective Error Messaging

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 163
2002 IS Catalog

Universal Frequency Technical Data

Converter Isolator Power Supply


Nominal voltage
Terminals 23, 24 or Power Rail
20-30 VDC
Power consumption 2.2 W
Input
Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current (Im) max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Quiescent voltage/short circuit current: 18 V / 5 mA
Model Number
Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA
KFD2-UFC-1
Outputs
■ 24 VDC supply Relay output 1 (SPDT) Terminals 10, 11 and 12
Relay output 2 (SPDT) Terminals 16, 17 and 18
■ Operating range 0.06-720,000 Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2A
RPM (0.001-12,000 kHz) Mechanical life ≥ 5 x 107 operations
■ Analog and digital outputs Energizing / de-energizing delay ≈ 20 ms / ≈ 20 ms
■ PC programmable Output 3 (passive transistor) Terminals 19+ and 20-
Nominal current 50 mA, short circuit-protected
This universal frequency converter converts Logic 1 voltage drop < 2.5 V
a digital input signal into an analog output Logic 0 output switched off (leakage < 10 µA)
signal for connection to standard current
Output 4 (current) Terminals 8+ and 7-
input devices. A passive transistor output
Open circuit voltage ≤ 24 VDC
isolates and transfers the digital signal.
Two relay outputs can be programmed to Output current 0-20 mA or 4-20 mA
actuate at desired frequencies. The unit is Error signal Downscale < 3.6 mA, upscale ≥ 22 mA
programmable with a PC and the Load ≤ 650 Ω
PACTware configuration software. Mechanical
A debounce filter eliminates extraneous
Housing Makrolon KF housing (see page 387)
Signal Conditioners

signals from relay bounce.


Dimensions (mm) 118 x 40 x 115
Lead breakage and short circuits in the Weight 300 g (10.6 oz.)
sensor are indicated by a red LED and
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
through the collective error output via
Power Rail.
Note: For information about programming,
This unit is not intrinsically safe. refer to our website at www.am.pepperl-fuchs.com
Connection Diagram

KFD2-UFC-1
Input II Input I 11
RxD 10 Output 1
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1 TxD Programming
12
GND Jack
17
16 Output 2
R2 18
2 2 19
R1 Output 3
20
R1
8 Output 4
7 0/4-20 mA
13 Start Up
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 14 Override
LB/SC LB/SC LB 23
Supply
24 24 VDC

Collective Error Messaging

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


164 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Universal Frequency


Power Supply Terminals 23, 24 Converter Isolator
Nominal voltage 20-90 VDC; 40-250 VAC
Power consumption 2.2 W; 3 VA with Display
Input
Connection type 2-wire sensor: terminals 1+, 3-
3-wire sensor: terminals 1+, 2- and 3
start-up override terminals: 13+, 14-
Input I Sensor
Input resistance 4.7 kΩ
Input pulse length/interval ≥ 50 µs / ≥ 50 µs
Voltage 22 V
Current (Im) max. 30 mA; limitation 40 mA
Lead monitoring breakage I ≤ 0.15 mA
short circuit I > 6.5 mA
Input II start-up override: 1-1000 s, in 1s steps
Quiescent voltage/short circuit current: 18 V / 5 mA
Model Number
Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA
KFU8-UFC-1.D
Outputs
Relay output 1 (SPDT) Terminals 10, 11 and 12 ■ 24 VDC / 120 VAC / 240 VAC supply
Relay output 2 (SPDT) Terminals 16, 17 and 18
■ Operating range 0.06-720,000 RPM
Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2A
(0.001-12,000 kHz)
Mechanical life ≥ 5 x 107 operations
Energizing / de-energizing delay ≈ 20 ms / ≈ 20 ms ■ Analog and digital outputs
Output 3 (passive transistor) Terminals 19+ and 20- ■ PC and push-button
Nominal current 50 mA, short circuit-protected programmable
Logic 1 voltage drop < 2.5 V ■ LCD display
Logic 0 output switched off (leakage < 10 µA)
This universal frequency converter converts
Output 4 (current) Terminals 8+ and 7-
a digital input signal into an analog output
Open circuit voltage ≤ 24 VDC signal for connection to standard current
Output current 0-20 mA or 4-20 mA input devices. A passive transistor output
Error signal Downscale < 3.6 mA, upscale ≥ 22 mA isolates and transfers the digital signal. Two
Load ≤ 650 Ω relay outputs can be programmed to
actuate at desired frequencies. The units is
Mechanical
programmable with a PC and the

Signal Conditioners
Housing Makrolon KF housing (see page 387)
PACTware configuration software. A
Dimensions (mm) 118 x 40 x 115
debounce circuit eliminates extraneous
Weight 300 g (10.6 oz.) signals from relay bounce.
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
Lead breakage and short circuits in the
sensor are indicated by a red LED.
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com This unit is not intrinsically safe.

Connection Diagram

KFU8-UFC-1.D
Input II Input I 11
RxD 10 Output 1
TxD Programming
(+) 1 (+) 1 (+) 1 (+) 1 (+) 1 (+) 1 12
GND Jack
17
16 Output 2
18
R2 19 (+)
2 2 Output 3
R1 20 (–)
R1 8 (+) Output 4
7 (–) 0/4-20 mA
13 (+) Start Up
(– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 (– ) 3 14 (– ) Override
23
LB/SC LB/SC LB Supply
24 24 VDC
120 VAC
240 VAC

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 165
2002 IS Catalog

DC Current Input Technical Data


2 Form C Contact Power Supply Terminals 11+, 12- or Power Rail
Nominal voltage 9-30 VDC
Outputs Isolator Power consumption ≤ 2.5 W, 1.8 W typical
Input Terminals 1+, 2-
Input current 1-100 mA
Excitation (terminal 3+) 24 VDC @ 20 mA
Maximum overload 170 mA max., 60 VDC on input
Impedance 20 Ω typical
Output Terminals 4, 5, and 6; 7, 8, and 9
Type 2 SPDT (Form C) relays
Current ratings (resistive loads) 120 VAC @ 5A
240 VAC @ 2A
28 VDC @ 5A
Mechanical life ≥ 107 operations
Repeatability (constant temp.)
Model Number > 5 mA 0.1% of full scale
KFDA-DCI < 5 mA 0.2% of full scale
Limit Differentials (deadbands)
■ Wide range of DC current inputs > 5 mA ±0.25-5% of span
■ Field configurable input/output < 5 mA 1-5% of span
Stability
■ 3-way isolation Temperature drift ±0.05% of full scale / ºC (max.)
■ Accepts bipolar inputs Power ±0.01% of full scale / % of power change
Common Mode Rejection DC to 60 Hz: 120 dB
The KFDA-DCI accepts a DC current input Isolation 3-way 1,800 VDC
and provides two adjustable contact
Response time
outputs. This limit alarm also effectively
Dynamic Deadband relay condition changes when proper
eliminates ground loops with 1,800 VDC
isolation separating input, output and condition exists for 100 ms
power supply. Normal mode (analog filter) ≤ 400 ms, 200 ms typical
Mechanical
The KFDA-DCI is outfitted with three
LEDs. The first is a green INPUT LED Housing Makrolon KF style housing (see page 387)

which indicates DC power and input signal Dimensions (mm) 115 x 20 x 118
status. If this LED is not illuminated upon Weight 100 g (3.5 oz.)
Signal Conditioners

power-up, check wiring connections. Protection (IEC) IP20


When the signal is over 110% of the full Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
scale range, the INPUT LED flashes at 8
Hz; below 0% it flashes at 4 Hz. Each
setpoint has its own red LED that indicates
the relay state. An illuminated LED
indicates a tripped condition. Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com
This unit is not intrinsically safe.
Connection Diagram

KFDA-DCI

(+24 VDC) 3
(+) 1
DC Input
(– ) 2
4 7
Output A 5 8 Output B
6 9
11 (+) DC Power
12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


166 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data DC Voltage Input


Power Supply Terminals 11+, 12- or Power Rail 2 Form C Contact
Nominal voltage 9-30 VDC
Power consumption ≤ 2.5 W, 1.8 W typical Outputs Isolator
Inrush current ≤ 300 mA max.
Input Terminals 1+, 2-
Input voltage 10 mV to 200 V
Excitation (terminal 3+) 24 VDC @ 20 mA
Impedance > 100 kΩ typical
Output Terminals 4, 5, and 6; 7, 8 and 9
Current rating (resistive loads) 120 VAC @ 5 A
240 VAC @ 2 A
28 VDC @ 5 A
Mechanical life ≥ 107 operations
Repeatability (constant temperature):
> 50 mV 0.1% of full scale
< 50 mV 0.2% of full scale Model Number
Limit differentials (deadbands): KFDA-DCV
> 50 mV 0.25-5% of span
< 50 mV 1-5% of span ■ Wide range of DC voltage inputs
Temperature drift ± 0.05% of full scale / ºC (max.)
Power ±0.01% of full scale/% of power change
■ Field configurable inputs/outputs
Common mode rejection DC to 60 Hz: 120 dB ■ 3-way isolation
Isolation 3-way 1,800 VDC ■ 2 adjustable, independent relay
Response time: contact outputs
Dynamic deadband relay condition changes when proper
The KFDA-DCV accepts a DC voltage input
condition exists for 100 ms and provides two adjustable relay outputs.
Normal mode (analog filtering) < 200 ms typical, 400 ms max. This limit alarm also effectively eliminates
Mechanical ground loops with 1,800 VDC isolation
Housing Makrolon KF style housing (see page 387) separating input, output and power supply.
Dimensions (mm) 115 x 20 x 118 Setpoints can be configured as HI or LO in
Weight 100 g (3.5 oz.) selectable controlsafe or non-controlsafe
Protection (IEC) IP20 operating modes. The KFDA-DCV relies on
deadband (hysteresis) and constant sampling
Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
of the input to prevent false switching when

Signal Conditioners
the input varies slightly on either side of the
setoint. The input must remain beyond the
setpoint for 100ms, uninterrupted, to qualify
as a valid trip condition. To return the alarm
to an untripped condition, the input signal
Note: For information about programming, must be outside the deadband and remain
refer to our website at www.am.pepperl-fuchs.com there for 100 ms. This time-based dynamic
deadband, in addition to the evaluation of
Connection Diagram hysteresis, improves setpoint stability. Select
unipolar operation for inputs that do not
change in polarity.
KFDA-DCV The KFDA-DCV is equipped with three LEDs.
The first is a green INPUT LED which indicates
DC power and input signal status. If this LED
does not illuminate on power-up, check wiring
(+24 VDC) 3
connections. When the signal input is over
(+) 1
DC Input 110% of the full scale range, the INPUT LED
(– ) 2
4 7 will flash at 8 Hz; below 0% it will flash at 4
Output A 5 8 Output B Hz. Each setpoint has its own LED which
6 9
indicates the relay state; an illuminated LED
11 (+) DC Power
12 (– ) Supply indicates a tripped condition.
This unit is not intrinsically safe.

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 167
2002 IS Catalog

DC Current/Voltage Technical Data


Input 2 Form C Contact Power Supply Terminals 14+, 15- or Power Rail
Nominal voltage 20-30 VDC
Outputs Isolator Nominal current ≤ 75 mA
Power consumption ≤ 2.25 W, 1.68 W typical

Input
Measuring range voltage (terminals 1+, 3-) 0/1-5 V
Input load 50 kΩ
Measuring range voltage (terminals 1+, 3-) 0/2-10 V
Input load 100 kΩ
Measuring range voltage (terminals 2+, 3) 0/4-20 mA
Input load 50 Ω

Output
Output I (terminals 7, 8, 9) trip value 1
Output II (terminals 10, 11, 12) trip value 2
Model Number Contact load AC: 250V / 5A / 1250VA
DC: 125V / 5A / 150 W
KFD2-GS-1.2W
Function
■ Single-channel, 24 VDC supply Response time 100 ms
■ Current and voltage analog inputs Accuracy/repeatability < 0.5%
Temperature drift 0.01% / ºC in reference to set limits
■ 2 programmable trip points
Isolation 1000 V
The KFD2-GS-1.2W is a trip amplifier for two Mechanical
independently field-configurable limit alarms.
Housing
Three-way galvanic isolated units convert 0/4-20
mA, 0/1-5 V and 0/2-10 V signals into trip point Material Makrolon
outputs. Style KF housing (see page 387)
Dimensions (mm) 115 x 20 x 118
For high alarm indication, the status of the contact
Weight 120 g (4.2 oz.)
output changes when the setpoint is exceeded
and will not reset until a lower value is met. The Protection (IEC) IP20
difference between these states is the adjustable
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
hysteresis.
The trip alarm is adjustable by a selector switch
High-/Low alarm
and potentiometer. Dip switch Mode of
ON: Limit 1
Signal Conditioners

Input responds to
operation
functions range both outputs
A monitoring voltage output of 0-10 V can be used on side 1
to adjust limit values and hysteresis without of unit
interrupting the input signal.
This unit is not intrinsically safe. 0 1 2 3 4 5 6

Note: For information about programming,


Switch Position Function refer to our website at www.am.pepperl-fuchs.com

S1.1 0 0/2V...10V input range Connection Diagram


1 0/1V...5V input range

S1.2 0 Low alarm output 1


1 High alarm output 1
KFD2-GS-1.2W
S1.3 0 Low alarm output 11 1
1 High alarm output 11 0V...10V 8
2V...10V 2 7 Output 1
0mA...20mA 9
S1.4 0 Relays open in alarm state output 1 4mA...20mA
1 Relays closed in alarm state output 1 3
11
Feed Back 4
10 Output 2
S1.5 0 Relays open in alarm state output 11 Trip Value 1 5 12
1 Relays closed in alarm state output 11
Trip Value 2 6
14
S1.6 0 Output 1 independent of output 11 Supply
15 24 VDC
1 Limit 1 responds to both outputs

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


168 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Transmitter


Power Supply Terminals 23+, 24- or Power Rail Power Supply
Nominal voltage 20-30 VDC
Max. voltage Um 40 VDC Isolator
Power consumption ≈ 2.2 W

Input Terminals 1, 2 and 3


Input signal 0/4-20 mA
Available voltage ≥ 15 V at 20 mA

Output
Output I Terminals 10, 11, 12
Output II Terminals 16, 17, 18
Output I & II type Form C, SPDT contact
Contact loading 250 VAC / 2A / cos ϕ ≥ 0.7; 40 VDC/2A
Maximum voltage (Um) 40 VDC
Pull-in/drop-out delay ≈ 20 ms / ≈ 20 ms
Mechanical life 5 x 107 operations
Output III Terminals 7, 8: analog signal
Model Number
Current range 0/4-20 mA KFD2-CRG-1.D
Quiescent voltage ≤ 24 VDC
Load ≤ 650Ω ■ Current source or transmitter
inputs
Transfer Characteristics
■ Analog output 0/4-20 mA
Accuracy 0.1% of full scale value (output < 10µA)
Temperature current measurement: 0.003% / ºC ■ 2 relay outputs
current output: 0.005% / ºC ■ Lead breakage and
current measurement & output: 0.006% / ºC short-circuit monitoring
Linearization current measurement and ■ Galvanic isolation
current output 0.025%
Input delay ≤ 200 ms
Isolation Galvanic isolation The KFD2-CRG-1.D transmitter power
supply is suited for a variet of measuring
Mechanical tasks. 2- and 3-wire transmitters as well
Housing Makrolon KF style housing (see page 387) as active power supplies with 0/4-20 MA
Dimensions (mm) 115 x 40 x 118 signals can be connected. Two relays and
Weight 300 g (10.5 oz.) an active 0/4-20 mA current output are

Signal Conditioners
Protection (IEC) IP20 available.
Operating Temperature -20ºC to +60ºC (-4ºF to +149ºF) The input has lead breakage and short-
circuit monitoring.
Programming is via a PC (using
PACTware) or by using the control panel
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com on the front of the device.
This unit is not intrinsically safe.
Connection Diagram

KFD2-CRG-1.D

(+) 1 (+) 1 7 (– ) 0/4...20mA


8 (+) Output
(– ) 2 Relay 1 10
(+) 1 11 Output 1
Relay 2
12
16 Output 2
(– ) 2 17
18
(– ) 2 3
3 23 (+) DCV
24 (– ) PC
Power
3 3 Supply
Collective Error Messaging
Input

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 169
2002 IS Catalog

Transmitter Power Technical Data

Supply Isolator Power Supply


Nominal voltage
Terminals 23, 24
20-90 VDC or 48-253 VAC
Max. voltage Um 253 VDC
Power consumption ≈ 2.2 W / 2.5 VA
Input Terminals 1, 2 and 3
Input signal 0/4-20 mA
Available voltage ≥ 15 V at 20 mA
Output
Output I Terminals 10, 11, 12
Output II Terminals 16, 17, 18
Output I & II type Form C, SPDT contact
Contact loading 250 VAC / 2A / cos ϕ ≥ 0.7; 40 VDC/2A
Maximum voltage (Um) 40 VDC
Pull-in/drop-out delay ≈ 20 ms / ≈ 20 ms
Mechanical life 5 x 107 operations
Model Number Output III Terminals 7, 8: analog signal
KFU8-CRG-1.D Current range 0/4-20 mA
Quiescent voltage ≤ 24 VDC
■ Current source or transmitter inputs Load ≤ 650Ω

■ Analog output 0/4-20 mA Transfer Characteristics


Accuracy 0.1% of full scale value (output < 10µA)
■ 2 relay outputs
Temperature current measurement: 0.003% / ºC
■ Lead breakage and current output: 0.005% / ºC
short-circuit monitoring current measurement & output: 0.006% / ºC
■ Galvanic isolation Linearization current measurement and
current output 0.025%
The KFU8-CRG-1.D transmitter power Input delay ≤ 200 ms
supply is suited for a variety of measuring
Isolation Galvanic isolation
tasks. 2- and 3-wire transmitters as well
as active power supplies with 0/4-20 MA Mechanical
signals can be connected. Two relays and Housing Makrolon KF style housing (see page 387)
an active 0/4-20 mA current output are Dimensions (mm) 115 x 40 x 118
available. Weight 300 g (10.5 oz.)
The input has lead breakage and short Protection (IEC) IP20
Signal Conditioners

circuit monitoring. Operating Temperature -20ºC to +60ºC (-4ºF to +149ºF)


The universal power requirement allows
AC or DC power of unit.
Programming is via a PC (using PACTware)
or by using the control panel on the front Note: For information about programming,
of the device. refer to our website at www.am.pepperl-fuchs.com

This unit is not intrinsically safe. Connection Diagram

KFU8-CRG-1.D

(+) 1 (+) 1 7 (– ) 0/4...20mA


8 (+) Output
(– ) 2 Relay 1 10
(+) 1 11 Output 1
Relay 2
12
16 Output 2
(– ) 2 17
18
(– ) 2 3
3 23 (+)
24 (– ) PC

3 3 Universal
Power
Input

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


170 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Thermocouple Input


Power Supply Terminals 11+, 12- or Power Rail 2 Form C Contact
Nominal voltage 9-30 VDC
Power consumption ≤ 2.5 W, 1.8 W typical Outputs Isolator
Inrush current ≤ 300 mA
Input (not intrinsically safe) Terminals 1+, 2-
Thermocouples B,E,J,K,R,S or T
Overload ≤ ±10 VDC on input
Impedance > 1 MΩ
Burnout detection < 1.5 µA
Output (not intrinsically safe) Terminals 4, 5, and 6; 7, 8, and 9
Type 2 SPDT (Form C) relays
Current rating 120 VAC @ 5 A
240 VAC @ 2 A
28 VDC @ 5 A
Mechanical life ≥ 107 operations
Repeatability (constant temp.) 0.2% for temp. > 0ºC Model Number
0.3% for temp. < 0ºC KFDA-TC
Limit differentials (deadbands) 0.25-5% of span
Temperature drift ±0.05% of full scale / ºC (max.) ■ Wide input range of thermocouples
Power ±0.01% of full scale / % power change
■ Field configurable input/output
Common mode rejection DC to 60 Hz: 120 dB
Isolation 3-way 1,800 VDC ■ 3-way isolation
Response time ■ 2 adjustable independent relay
Dynamic deadband relay condition changes when proper
contact outputs
condition exists for 100 ms The KFDA-TC accepts a B, E, J, K, S, R or T
Normal mode (analog filter) < 250 ms type thermocouple input and provides two
Mechanical adjustable contact outputs. This limit alarm also
Housing effectively eliminates ground loops with 1,800
VDC isolation separating input, output and power
Material Makrolon
supply. The KFDA-TC is configurable for multiple
Style KF housing (see page 387)
temperature ranges per thermocouple type. It
Dimensions (mm) 115 x 20 x 118
also accepts bipolar inputs and offers selectable
Weight 100 g (3.5 oz.) upscale and downscale burnout detection.
Protection (IEC) IP20

Signal Conditioners
Setpoints can be configured as HI or LO in
Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
selectable controlsafe or non-controlsafe
operating modes. The KFDA-TC relies on
deadband (hysteresis) and constant sampling of
the input to prevent false switching when the input
varies slightly on either side of the setpoint. The
Note: For information about programming, input must remain uninterrupted beyond the
refer to our website at www.am.pepperl-fuchs.com
setpoint for 100 ms to qualify as a valid trip
Connection Diagram condition. To return the alarm to an untripped
condition, the input signal must fall outside the
deadband and remain there for 100 ms. This
time-based dynamic deadband improves
KFDA-TC
setpoint stability.

The KFDA-TC is equipped with three LEDs. The


Thermocouple first is a green INPUT LED which indicates DC
Input (+) 1 power and input signal status. If this LED does
(– ) 2
not illuminate during power-up, check wiring
connections. When the input signal is over 110%
4 7
Output A 5 Output B
of the full scale range, the INPUT LED flashes at
8
6 9 8 Hz; below 0% it flashes at 4 Hz. Each setpoint
11 (+) DC Power has its own red LED that indicates the relay state.
12 (– ) Supply An illuminated LED indicates a tripped condition.

This unit is not intrinsically safe.

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 171
2002 IS Catalog

RTD Input Technical Data


2 Form C Contact Power Supply Terminals 11+, 12- or Power Rail
Nominal voltage 9-30 VDC (unregulated acceptable)
Outputs Isolator Power consumption ≤ 2.5 W, 1.8 W typical
Inrush current ≤ 300 mA
Input Terminals 1, 2 and 3
Type 3-wire RTDs
Input protection withstand ±5 VDC
Excitation current:
Pt100, Pt500, Pt1000 < 2 mA
Ni120, Cu100, NiFe604 < 2 mA
Cu10 < 10 mA
Lead resistance 40% of base sensor resistance or
100 Ω (whichever is less) max. per lead
Output Terminals 4, 5 and 6; 7, 8 and 9
Type 2 SPDT (Form C) relays
Model Number Current rating (resistive loads) 120 VAC @ 5 A
KFDA-RTD 240 VAC @ 2 A
28 VDC @ 5 A
■ Wide input range of RTD Mechanical life ≥ 107 operations
Repeatability (constant temp.) 0.2% of full scale
■ Field configurable input/output
Limit differentials (deadbands) 1-5% of span
■ 3-way isolation Temperature drift ±0.05% of full scale / ºC (max.)
■ 2 adjustable independent relay Common mode rejection DC to 60 Hz: 120 dB
contact outputs Isolation 3-way 1,800 VDC

The KFDA-RTD limit alarm accepts a 3-wire RTD Response time


input (Pt100, Pt500, Pt1000, Cu10, Cu100, Ni120, Dynamic deadband relay condition changes when proper
NiFe604) and provides two adjustable relay condition exists for 100 ms
outputs. This limit alarm also effectively eliminates Normal mode (analog filter) ≤ 400 ms, 200 ms typical
ground loops with 1,800 VDC isolation separating
Mechanical
input, output and power supply. The KFDA-RTD
Housing Makrolon KF style housing (see page 387)
is configurable for up to eight temperature ranges
for each RTD type. Dimensions (mm) 115 x 20 x 118
Weight 100 g (3.5 oz.)
Setpoints can be configured as HI or LO in Protection (IEC) IP20
Signal Conditioners

selectable controlsafe or non-controlsafe operating


modes. The KFDA-RTD relies on deadband Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)
(hysteresis) and constant sampling of the input to
prevent false switching when the input varies
slightly on either side of the setpoint. The input
must remain uninterrupted beyond the setpoint
for 100 ms to qualify as a valid trip condition. To Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com
return the alarm to an untripped condition, the
input signal must fall outside the deadband and Connection Diagram
remain there for 100 ms. This time-based dynamic
deadband improves setpoint stability.

The KFDA-RTD is outiftted with three LEDs. The KFDA-RTD


first is a green INPUT LED which indicates DC
power and input signal status. If this LED is not
illuminated at power-up, check wiring connections.
RTD Input
When the input signal is over 110% of the full scale (+) 1
range, the INPUT LED flashes at 8 Hz; below 0% (– ) 2
it flashes at 4 Hz. Each setpoint has its own red (R) 3
4 7
LED that indicates the relay state. An illuminated Output A 5 8 Output B
LED indicates a tripped condition. 6 9
11 (+) DC Power
This unit is not intrinsically safe. 12 (– ) Supply

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


172 E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com
2002 IS Catalog

Technical Data Universal Input 2 Form C


Power Supply Terminals 14+, 15- or Power Rail Contact Output / PC
Nominal voltage 20-35 VDC
Maximum voltage Um 40 VDC Interface Isolator
Power consumption 1.5 W

Input Terminals 1, 2, 3, 4, 5, 6
Type Pt100, Ni100
Thermocouple B,E,J,K,L,N,R,S or T
0-10 V, 0-20 mA, configuration with
programming jack
Max. lead resistance ≤ 50 Ω per lead
Test current 400 µA with RTDs
NOTE: Switch off current for lead breakage monitoring during measurement

Output
Output I (Limit 1) Terminals 7, 8 and 9
Output II (Limit 2) Terminals 10, 11 and 12
Contact load 253 VAC / 2 A / cos ø ≥ 0.6 Model Number
Mechanical life 2 x 107 operations KFD2-GU-1
Response time ≤ 370 ms
Temperature drift ±0.007% of switchpoint per ºC∆T ■ Universal temperature input
Power ≤ 0.0035% of span ■ Programming & calibration via PC
Isolation Galvanic isolation
■ 3-way isolation
Mechanical
■ CJC for thermocouples and lead
Housing Makrolon KF style housing (see page 387)
resistance compensation for RTDs
Dimensions (mm) 115 x 20 x 118
Weight 100 g (3.5 oz.) The KFD2-GU-1 universal input limit alarm is
Protection (IEC) IP20 field-configurable for 0-10 V, 0-20 mA, Pt100/
Ni100 and all thermocouple inputs with three-
Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)
way galvanic isolation. This unit also features
internal/external cold junction compensation
(CJC) and burnout detection for thermocouples
and lead short circuit monitoring for RTDs and
current/voltage inputs. Calibration, adjustments
and monitoring are achieved through a serial
interface to a PC.

Signal Conditioners
All parameters are programmable through a K-
ADP1 cable (sold separately) that provides the
connection between the programming
receptacle of the KFD2-GU and the RS232 PC
interface.
Note: For information about programming,
refer to our website at www.am.pepperl-fuchs.com Accessories include removable terminals with
internal cold junction compensation (K-CJC)
Connection Diagram and a K-SK programming software kit. The K-
ADP1 cable and K-SK software kit are required
(+) 6 unless the KFD2-GU is configured by P+F.
KFD2-GU-1 This unit is not intrinsically safe.
(+) 5
(+) 4
CJC
Type K-CJC-GN
(+) 3 (+) 3 (+) 3

7
Signal Processor

(+) 6 8 Output 1
(+) 5 9
(+) 1 (+) 4 10
11 Output 2
(– ) 1 (– ) 1 (+) 3
12
(– ) 1
(– ) 2 11 (+) DC
12 (– ) Power
PC
(– ) 2 (– ) 2 (– ) 2 (– ) 2 (– ) 2 (– ) 2
Supply

K-ADPI

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607


E-mail: greenteam@us.pepperl-fuchs.com • www.am.pepperl-fuchs.com 173