DESIGN OF MOMENT CONNECTIONS (APEX)

CONNECTION BETWEEN UB UB 254X146X37 ( RIGID CONNECTION)


200
FORCES 656 + +
Moment Mz = 2.2 T-m 236 + +
Shear Fy = 1.5 T
Axial Fx = 1.4 T

BOLT DISTANCES
Number of blots (N) = 8 256

Section height = 256

D1 = 2(a1.a1+a2.a2+a3.a3………..) 90 + +
= 0.99
N1 = Mz . a3 + + 40
= 0.52
D2 = 8

N2 = 1.4
(Allowable
Tension per bolt(T) = (N1/D1)+(N2/D2) (T) 8 M 16 bolts
= 0.70 T 7 Grade 8.8
(Safe)
shear per bolt(S) = Fy/ N
= 0.19 T 5.8
(Safe)
END PLATE
Grade of steel = 50

Design strength(Fy) = 275 N / mm^2

Edge distance from the bolt (e) = 24 mm

Moment in the plate (Mp) = ( 2 x T x e) = 336175.53 N-mm

width of plate (b) = 210 mm


12
thickness of plate (t) = 16 mm

Bending stress (Fb) = (Mp x 6)/(b x t x t)


= 37.52 N / mm^2 < Fb(allowable)= 0.75*Fy
= 206.25 N / mm^2

provide endplate of dimension


b 200 mm
h 376 mm
t 16 mm