BUILDING SPACE PROGRAMMING

AREA NO. OF FACTOR PER TOTAL AREA REMARKS REFERENCES


PERSONS PERSON

Administrative
Service
-Lobby 25 0.96 48 sq.m The main lobby and waiting room https://core.ac.u
should be located with convenient k/download/pdf/
access to the stairs, corridors and 10129009.pdf
elevators leading to the https://www.db
administrative and patient areas, but m.gov.ph/wp-
access to these areas should be content/uploads
controlled by the information desk. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Waiting Area 25 0.96 48 sq.m -Waiting area should be located with https://core.ac.u
convenient access to the stairs, k/download/pdf/
corridors and elevators leading to 10129009.pdf
the administrative and patient areas, https://www.db
but access to these areas should be m.gov.ph/wp-
controlled by the information desk. content/uploads
-Adequate waiting space should be /Issuances/201
provided for the family and friends 3/Joint%20Circ
of the patients. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Information and 5 0.96 4.80 sq.m -Information desk should be located https://core.ac.u
Reception Area with convenient access to the stairs, k/download/pdf/
corridors and elevators leading to 10129009.pdf
the administrative and patient areas, https://www.db
m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Toilet
Male Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
Female Toilet Room Toilets should be arranged to more https://setupmy.
15 SQ.M. than one com/train-my- -
13 1.15 SQ.M. person to use its facilities at the
staff/front-
same time.
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
s.html
-Business Office 10 0.96 9.60 sq.m The general business office should https://core.ac.u
have several cashiers' windows k/download/pdf/
near the main lobby but there 10129009.pdf
should be no direct entry into the https://www.db
office m.gov.ph/wp-
from that area. This office provides content/uploads
space for the clerical staff and /Issuances/201
equipment and should have a safe 3/Joint%20Circ
or vault fro records and patients' ular%202013/D
valuables. OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Admitting Office 5 1.5 5.50 sq.m
-Accounting Room 10 0.96 9.60 sq.m
-Medical Records 3 0.96 2.88 sq.m The medical record room and library https://core.ac.u
are directly related regarding study k/download/pdf/
and research, and can be better 10129009.pdf
managed by a single librarian. It https://www.db
should be remembered that the m.gov.ph/wp-
library will be used not only by the content/uploads
staff and interns but also by a /Issuances/201
certain number of people from 3/Joint%20Circ
outside the hospital. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Office of the 4 0.96 4.80 sq.m The Office of the Chief of Hospital https://core.ac.u
Chief of Hospital should be located at the entrance k/download/pdf/
for control. This office would handle 10129009.pdf
receiving and administrative work. https://www.db
Shall be responsible for the overall m.gov.ph/wp-
management and administration of content/uploads
the hospital /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Laundry and 5 1.5 5.50 sq.m The laundry would wash and https://core.ac.u
Linen Area decontaminate the dirty linen and k/download/pdf/
then dry and prepare it for re-use. 10129009.pdf
The linen room would be used to https://www.db
store and issue linen for the m.gov.ph/wp-
hospital. The should be a mending content/uploads
room and a new stock room within /Issuances/201
the central linen room. 3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Maintenance and 5 1.5 5.50 sq.m To facilitate quick and economical https://core.ac.u
Housekeeping Area repairs and replacements the k/download/pdf/
hospital should have good 10129009.pdf
maintenance shops. A carpenter https://www.db
shop for general repairs and m.gov.ph/wp-
refinishing work, an electrical shop content/uploads
for repairing small motors, lamps /Issuances/201
and other fixtures, and a mechanical 3/Joint%20Circ
shop with equipment for heating and ular%202013/D
plumbing repairs would be provided. OH/Manual%20
-A hospital and other health facilities RSSGH_%203
shall provide and maintain a healthy %20levels.pdf
and aesthetic environment for https://www.fgig
patients, personnel and public. uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Parking Area for 9.29 Should be located near the https://core.ac.u
Transport Vehicle entrances. k/download/pdf/
A hospital and other health facilities 10129009.pdf
shall provide a minimum of one (1) https://www.db
parking space for every twenty-five m.gov.ph/wp-
(25) beds. content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Supply Room 3 0.96 2.88 sq.m All supplies. except pharmaceuticals
would be distributed through central
supply. For this reason, it should be
located centrally with
easy access to the different storage
rooms.
-Waste Holding 3 0.96 2.88 sq.m The waste holding room shall be
Room immediately accessible to an
exterior door.
-Dietary 10 0.96 9.60 sq.m The kitchen should be located at https://core.ac.u
grade level to insure adequate light k/download/pdf/
and ventilation and ease cf daily 10129009.pdf
delivery of meat, vegetables, and https://www.db
dairy products. m.gov.ph/wp-
If located adjacent to the service content/uploads
court deliveries can be made /Issuances/201
directly into the refrigerator section 3/Joint%20Circ
preventing carting of supplies ular%202013/D
through corridors and food OH/Manual%20
preparation areas. There should be RSSGH_%203
no circulation through the kitchen to %20levels.pdf
other areas. https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Dietitian Area 5 0.96 4.80 sq.m The dietitian's office should be https://core.ac.u
located to provide good control and k/download/pdf/
supervision of the entire kitchen. 10129009.pdf
https://www.db
m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Supply Receiving 5 0.96 4.80 sq.m There should be a receiving room https://core.ac.u
Area where goods could be unpacked k/download/pdf/
and checked before they are taken 10129009.pdf
into the storage rooms. A small https://www.db
room for overnight storage of goods m.gov.ph/wp-
received,but not checked is content/uploads
necessary. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Cold and Dry 5 0.96 4.80 sq.m As mentioned previously direct https://core.ac.u
Storage Area delivery of perishables to k/download/pdf/
refrigerators without going through 10129009.pdf
the food. Preparation areas is highly https://www.db
desirable. The refrigerator section m.gov.ph/wp-
should contain three units, one for content/uploads
meat, one for fruit and vegetables, /Issuances/201
and one for dairy products. Because 3/Joint%20Circ
of the rising popularity of ular%202013/D
frozen foods, a large freezer should OH/Manual%20
also be included for frozen meat, RSSGH_%203
vegetables %20levels.pdf
and ice cream, etc. https://www.fgig
The room should be convenient to uidelines.org/w
the receiving area and adjacent to p-
the meat, vegetable and salad content/uploads
preparation areas. /2016/11/1992-
93guidelines.pd
f
-Food Preparation 5 0.96 4.80 sq.m food preparation area shall be https://core.ac.u
Area located adjacent to delivery, interior k/download/pdf/
transportation, and storage facilities. 10129009.pdf
https://www.db
m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Cooking and 5 0.96 4.80 sq.m The main cooking section should be https://core.ac.u
Baking Area placed in a central location k/download/pdf/
convenient to the serving area and 10129009.pdf
away from the side walls. https://www.db
m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Serving and Food 5 0.96 4.80 sq.m In a facility using centralized meal
Assembly Area assembly, food trays are assembled
for service at a central location
close to the main production area
-Washing Area 7 0.96 6.72 sq.m The dish washing room should be -
located near the entrance to the
kitchen from the nursing units. The
food carts should be washed in a
separate room. The cart room
should be near the entrance and
convenient to the dish washing
area.
-Garbage Disposal 3 0.96 2.88 sq.m All garbage and in particular wet
Area waste, shall be stored in sealed
bins. Inside the room space shall
also be provided to wash the bins
before next use.
This area shall be located near and
adjoining the kitchen.
-Dining Area 65 0.96 62.40 sq.m Dining space(s) shall be provided
for ambulatory patients and staff.
These spaces shall be separate
from the food preparation and
distribution areas.
The dining room should be large
enough to accommodate the staff
and visitors using it in a two-hour
period. Cafeteria service is the
fastest and most economical for this
type of institution. A small private
dining space should be provided for
special luncheons, business
meetings, etc. A dining room should
also be provided for the kitchen
employees.
Male Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
Female Toilet Room Toilets should be arranged to more
https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the
com/train-my- -
same time. staff/front-
A room equipped with 1 or more office-
toilets and training/96-
sinks for public use room-type-
definitions-in-
.html
-Cadaver Holding 7.43/bed The morgue should be located to https://core.ac.u
Room provide optimum circulation k/download/pdf/
between the refrigerated boxes, the 10129009.pdf
entrance, the autopsy rooms and https://www.db
the exit. There should be between m.gov.ph/wp-
10-15 boxes depending upon the content/uploads
practices of the local morticians. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Clinical Service
-Emergency Room As mentioned previously most https://core.ac.u
emergency cases are cases best k/download/pdf/
admitted away from the public view. 10129009.pdf
The department should also be https://www.db
readily accessible for both m.gov.ph/wp-
ambulances and private content/uploads
automobiles which require parking /Issuances/201
space. A large number of 3/Joint%20Circ
emergency cases are accident ular%202013/D
cases in which the patient is OH/Manual%20
pronounced dead RSSGH_%203
on arrival or shortly after arrival at %20levels.pdf
the hospital. Location near the https://www.fgig
morgue would provide holding uidelines.org/w
space until the family could be p-
notified and the body picked up by a content/uploads
mortician. It would also facilitate the /2016/11/1992-
procedure on cases requiring 93guidelines.pd
autopsy and laboratory work. f
-Waiting Area 25 0.96 48 sq.m -Waiting area should be located with https://core.ac.u
convenient access to the stairs, k/download/pdf/
corridors and elevators leading to 10129009.pdf
the administrative and patient areas, https://www.db
but access to these areas should be m.gov.ph/wp-
controlled by the information desk. content/uploads
-Adequate waiting space should be /Issuances/201
provided for the family and friends 3/Joint%20Circ
of the patients. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
Male Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
Female Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time. staff/front-
A room equipped with 1 or more
office-
toilets and
sinks for public use training/96-
room-type-
definitions-in-
.html
-Examination and 6 0.96 5.76 sq.m These multi-purpose rooms should https://core.ac.u
Treatment Area with have adjoining dressing rooms to k/download/pdf/
Lavatory/Sink insure continuous use and should 10129009.pdf
be adjacent to a utility room which https://www.db
could be used jointly by several m.gov.ph/wp-
rooms. content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Observation Area 6 0.96 5.70 sq.m A room with one way glass windows https://core.ac.u
for observing pediatric patients in k/download/pdf/
adjoining rooms. The room may be 10129009.pdf
located adjacent to play areas and https://www.db
Speech Pathology. Audiovisual m.gov.ph/wp-
recording may also be required in content/uploads
this room. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Equipment and 4 0.96 3.84 sq.m There are a multitude of storage https://core.ac.u
Supply Storage areas required. Space must be k/download/pdf/
Area provided for clean instruments, 10129009.pdf
medical gases, janitors' supplies, https://www.db
sterile supplies, 1 spare operating m.gov.ph/wp-
tables and lights, anesthesia content/uploads
machines and other miscellaneous /Issuances/201
equipment and supplies. 3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Wheeled Stretcher 3 (2.70) 8.10 sq.m Storage space for stretchers and https://core.ac.u
Area wheelchairs shall be provided in a k/download/pdf/
strategic location, without restricting 10129009.pdf
normal traffic. https://www.db
m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Outpatient 6 0.96 5.76 sq.m The functions of the outpatient https://core.ac.u
Department department are education, k/download/pdf/
prevention, diagnosis, and 10129009.pdf
treatment of illness, and follow-up of https://www.db
hospital cases. It is very difficult to m.gov.ph/wp-
plan just how large or small an content/uploads
outpatient department should be for /Issuances/201
an estimated number of visits per 3/Joint%20Circ
year. The number of divisions, the ular%202013/D
number of stations, the number of OH/Manual%20
sessions, and their length, etc. all RSSGH_%203
must be considered. %20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Waiting Area 25 0.96 48 sq.m -Waiting area should be located with
convenient access to the stairs,
corridors and elevators leading to
the administrative and patient areas,
but access to these areas should be
controlled by the information desk.
-Adequate waiting space should be
provided for the family and friends
of the patients.
Male Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use training/96-
room-type-
definitions-in-
.html
Female Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
-Examination and 7.43/bed These multi-purpose rooms should https://core.ac.u
Treatment Area with have adjoining dressing rooms to k/download/pdf/
Lavatory/Sink insure continuous use and should 10129009.pdf
be adjacent to a utility room which https://www.db
could be used jointly by several m.gov.ph/wp-
rooms. content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Consultation Area 4 0.96 3.84 sq.m Special-purpose examination https://core.ac.u
rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Ob-Gyne 6 0.96 5.75 sq.m Special-purpose examination https://core.ac.u
rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Urology 6 0.96 5.75 sq.m Special-purpose examination https://core.ac.u
rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
- Cardiology 6 0.96 5.75 sq.m Special-purpose examination https://core.ac.u
rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
- Pulmonology 6 0.96 5.75 sq.m Special-purpose examination https://core.ac.u
rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
- Gastroenterol 6 0.96 5.75 sq.m Special-purpose examination https://core.ac.u
ogy rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Nephrology 6 0.96 5.75 sq.m Special-purpose examination https://core.ac.u
rooms. Rooms for special clinics k/download/pdf/
such as eye, ear, nose, and throat 10129009.pdf
examinations, if provided, shall be https://www.db
designed and outfitted to m.gov.ph/wp-
accommodate procedures and content/uploads
equipment used. A hand washing /Issuances/201
fixture and a counter or shelf space 3/Joint%20Circ
for writing shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Surgical and 6 (2.70) 16.20 sq.m -The traditional location for the https://core.ac.u
Obstetrical Service surgical suite has been on the top k/download/pdf/
floor on the north side. Efficient 10129009.pdf
lighting and mechanical ventilation https://www.db
were not possible as the suite was m.gov.ph/wp-
located where they could have content/uploads
natural light and be more or less /Issuances/201
dust-free. This was also the terminal 3/Joint%20Circ
point of the hospital and therefore ular%202013/D
avoided unnecessary circulation. OH/Manual%20
-The obstetrical unit shall be located RSSGH_%203
and designed to prohibit non related %20levels.pdf
traffic through the unit. When https://www.fgig
delivery and operating rooms are in uidelines.org/w
the same suite, access and service p-
arrangements shall be such that content/uploads
neither staff nor patients need to /2016/11/1992-
travel through one area to reach the 93guidelines.pd
other. Except as permitted f
otherwise herein, existing facilities
being renovated shall, as far as
practicable, provide all the required
support services.
-Major Operating 33.45 A main operating room or operating https://core.ac.u
Room theatre in a hospital can be used for k/download/pdf/
both inpatients and outpatients. 10129009.pdf
They are usually located away from https://www.db
the outpatient department. m.gov.ph/wp-
A set-up of operating rooms in a content/uploads
hospital may be a centralized or /Issuances/201
decentralized one. 3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Delivery Room 33.45 The Delivery Room is a special unit https://core.ac.u
in the hospital where pregnant k/download/pdf/
women give birth to babies. Prior to 10129009.pdf
transfer of the patient to the DR, the https://www.db
patient may need to stay inside the m.gov.ph/wp-
Labor Room where the mother is content/uploads
being assessed and monitored. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Sub-sterilizing 4.65 The central clean-up room provides https://core.ac.u
Area facilities for cleaning up after the k/download/pdf/
operation. The extent of the facilities 10129009.pdf
required is based upon the system https://www.db
used. m.gov.ph/wp-
-Sterilization facilities should be content/uploads
separate from the delivery area and /Issuances/201
adjacent to clean assembly. 3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Sterile Instrument, 4.65 -All supplies requiring sterilization https://core.ac.u
Supply and Storage would be sterilized and k/download/pdf/
-Area prepackaged in the central 10129009.pdf
sterilizing room and distributed https://www.db
through central supply. m.gov.ph/wp-
-All supplies except content/uploads
pharmaceuticals would be /Issuances/201
distributed through central supply. 3/Joint%20Circ
For this reason it should be located ular%202013/D
centrally with OH/Manual%20
easy access to the different storage RSSGH_%203
rooms. %20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Scrub-up Area 4.65 The scrub-up area is used for https://core.ac.u
scrubbing by the surgical team k/download/pdf/
before each operation. This room 10129009.pdf
should be located adjacent to the https://www.db
operating room to reduce walking m.gov.ph/wp-
distance after scrubbing and to content/uploads
allow the surgeons to see into the /Issuances/201
operating room while scrubbing. 3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Clean-up Area 4.65 The central clean-up room provides https://core.ac.u
facilities for cleaning up after the k/download/pdf/
operation. The extent of the facilities 10129009.pdf
required is based upon the system https://www.db
used. m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Dressing Room 2.32 All personnel who work in the https://core.ac.u
surgical suite change their clothing k/download/pdf/
before they enter the suite. Change 10129009.pdf
rooms should be provided for https://www.db
professional males, all females, and m.gov.ph/wp-
non-professional males. Each content/uploads
change room would contain locker, /Issuances/201
toilet and shower facilities. The 3/Joint%20Circ
personnel would enter the change ular%202013/D
rooms from outside the suite, OH/Manual%20
change shoes and clothes, and RSSGH_%203
enter the suite directly from the %20levels.pdf
change room. The reverse https://www.fgig
procedure would be used in leaving uidelines.org/w
the suite. p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
Male Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
Female Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
-Wheeled Stretcher 3 (2.70) 8.10 sq.m Storage space for stretchers and https://core.ac.u
Area wheelchairs shall be provided in a k/download/pdf/
strategic location, without restricting 10129009.pdf
normal traffic. https://www.db
m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Janitor’s Closet 4 0.96 3.84 sq.m The janitor's closet should be https://core.ac.u
adjacent to the central linen room k/download/pdf/
and in a position to maintain control 10129009.pdf
over the linen both clean https://www.db
and dirty. m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Nursing Unit 5 0.96 4.80 sq.m Special-care area units such as https://core.ac.u
recovery rooms, critical care units, k/download/pdf/
pediatric units, rehabilitation units, 10129009.pdf
and skilled nursing care or other https://www.db
specialty units. m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Semi-Private Room 7.43/bed Each unit is divided into two https://core.ac.u
with Toilet sections accommodating a standard k/download/pdf/
hospital bed, a day bed for a 10129009.pdf
companion/watcher, common cable https://www.db
TV, and bedside table and chair. m.gov.ph/wp-
Patients share a toilet and bath. The content/uploads
rooms are air-conditioned /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Patient Room 7.43/bed Hospital room design has a https://core.ac.u
significant impact on patient care k/download/pdf/
and recovery outcomes. Hospital 10129009.pdf
rooms should be safe spaces in https://www.db
which patients feel well cared for m.gov.ph/wp-
and staff can easily provide content/uploads
treatment. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Toilet 1.67 A separate toilet shall be provided https://core.ac.u
that is directly accessible to each k/download/pdf/
multi fixture central bathing area 10129009.pdf
without requiring entry into the https://www.db
general corridor. This may also m.gov.ph/wp-
serve as the required toilet training content/uploads
facility. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Isolation Room 9.29 One isolation room shall be https://core.ac.u
with Toilet provided for each 30 beds or major k/download/pdf/
faction thereof. Each isolation room 10129009.pdf
shall contain a clear floor area of https://www.db
120 square feet (11.15 square m.gov.ph/wp-
meters) and a single bed. A content/uploads
minimum of one isolation room shall /Issuances/201
be provided regardless of the size of 3/Joint%20Circ
the unit. There shall be an anteroom ular%202013/D
of a minimum of 20 square feet OH/Manual%20
(1.86 square meters), with facilities RSSGH_%203
for hand washing, gowning, and %20levels.pdf
storage of clean and soiled https://www.fgig
materials. One anteroom may serve uidelines.org/w
not more than two isolation rooms. p-
Each isolation room shall have an content/uploads
adjoining bathroom (with tub or /2016/11/1992-
shower). 93guidelines.pd
f
-Nurse Station 5 0.96 4.80 sq.m The nurses' station should be https://core.ac.u
located as centrally as possible in k/download/pdf/
the nursing unit and should 10129009.pdf
command full view of the nursing https://www.db
corridors. The nursing station will be m.gov.ph/wp-
used for the administrative work of content/uploads
the nurses inherent /Issuances/201
in-patient care, preparing 3/Joint%20Circ
medicines, and for doctor-nurse ular%202013/D
conferences. OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Treatment and 7.43/bed These multi-purpose rooms should https://core.ac.u
Medication Area have adjoining dressing rooms to k/download/pdf/
with Lavatory/Sink insure continuous use and should 10129009.pdf
be adjacent to a utility room which https://www.db
could be used jointly by several m.gov.ph/wp-
rooms. content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Central Sterilizing All supplies requiring sterilization https://core.ac.u
and Supply Room would be sterilized and k/download/pdf/
prepackaged in the central 10129009.pdf
sterilizing room and distributed https://www.db
through central supply. m.gov.ph/wp-
All supplies. except pharmaceuticals content/uploads
would be distributed through central /Issuances/201
supply. For this reason, it should be 3/Joint%20Circ
located centrally with easy access ular%202013/D
to the different storage rooms. OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Receiving and 5.02/staff There should be a receiving room https://core.ac.u
Releasing Area where goods could be unpacked k/download/pdf/
and checked before they are taken 10129009.pdf
into the storage rooms. A https://www.db
small.room for overnight storage of m.gov.ph/wp-
goods received,but not checked is content/uploads
necessary. /Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Work Area 5 0.96 4.80 sq.m The workroom shall contain https://core.ac.u
scrubbing and k/download/pdf/
gowning facilities at the entrance for 10129009.pdf
staff and housekeeping personnel, https://www.db
work counter, refrigerator, storage m.gov.ph/wp-
for supplies, and hand washing content/uploads
fixture. One workroom may serve /Issuances/201
more than one nursery room 3/Joint%20Circ
provided that required services are ular%202013/D
convenient to each. OH/Manual%20
Parts and components of the RSSGH_%203
division Work space. Located Very %20levels.pdf
close to the operation theatre and https://www.fgig
maternity section. uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Sterilizing Room 5 0.96 4.80 sq.m Near and equidistant from https://core.ac.u
professional areas, in order to k/download/pdf/
shorten the journeys made by 10129009.pdf
personnel to bring instruments to https://www.db
sterilize as much as possible. m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Sterile Supply 5 0.96 4.80 sq.m All supplies requiring sterilization https://core.ac.u
Storage Area would be sterilized and k/download/pdf/
prepackaged in the central 10129009.pdf
sterilizing room and distributed https://www.db
through central supply. m.gov.ph/wp-
All supplies. except pharmaceuticals content/uploads
would be distributed through central /Issuances/201
supply. For this reason it should be 3/Joint%20Circ
located centrally with easy access ular%202013/D
to the different storage rooms. OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Nursing Service
-Office of the Chief 5 0.96 4.80 sq.m Administrative center or nurse https://core.ac.u
Nurse station. This area shall have space k/download/pdf/
for counters and storage and shall 10129009.pdf
have convenient access to hand https://www.db
washing facilities. It may be m.gov.ph/wp-
combined with or include centers for content/uploads
reception and communication. /Issuances/201
Preferably, the station 3/Joint%20Circ
should permit visual observation of ular%202013/D
all traffic into the unit. OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Ancillary Service
-Primary Clinical
Laboratory
-Clinical Work Area 10.00 These multi-purpose rooms should https://core.ac.u
with Lavatory/Sink have adjoining dressing rooms to k/download/pdf/
insure continuous use and should 10129009.pdf
be adjacent to a utility room which https://www.db
could be used jointly by several m.gov.ph/wp-
rooms. content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Pathologist Area 5.02/staff The pathologist office should be https://core.ac.u
located so that he has access to the k/download/pdf/
laboratory, the histology section in 10129009.pdf
particular. A work space should be https://www.db
provided for examinations in the m.gov.ph/wp-
privacy of his office. content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
Male Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
A room equipped with 1 or more staff/front-
toilets and
office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
Female Toilet Room Toilets should be arranged to more https://setupmy
15 SQ.M. than one hotel.
13 1.15 SQ.M. person to use its facilities at the com/train-my- -
same time.
staff/front-
A room equipped with 1 or more
toilets and office-
sinks for public use
training/96-
room-type-
definitions-in-
.html
-X – Ray Room with 14.00 Radiography rooms shall be of a https://core.ac.u
Control Booth, size to accommodate the functional k/download/pdf/
Dressing Area and program. 10129009.pdf
Toilet Each X-ray room shall include a https://www.db
shielded control alcove. This area m.gov.ph/wp-
shall be provided with a view content/uploads
window designed to provide full /Issuances/201
view of the examination table and 3/Joint%20Circ
the patient at all times, including full ular%202013/D
view of the patient when the table is OH/Manual%20
in the tilt position or the chest X-ray RSSGH_%203
is being utilized. For mammography %20levels.pdf
machines with built-in shielding for https://www.fgig
the operator, the alcove may be uidelines.org/w
omitted when approved by the p-
certified physicist or state radiation content/uploads
protection agency. /2016/11/1992-
-A patient toilet shall be provided. It 93guidelines.pd
shall be f
convenient to the procedure room,
and if directly accessible to the scan
room, arranged so that a patient
may leave the toilet without having
to re enter the scan room.
-Dark Room 5 0.96 4.80 sq.m A darkroom may be required for https://core.ac.u
loading cassettes and shall be k/download/pdf/
located near the control room. This 10129009.pdf
darkroom shall be outside the 10- https://www.db
gauss field. m.gov.ph/wp-
content/uploads
/Issuances/201
3/Joint%20Circ
ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Film File and 5 0.96 4.80 sq.m All exposed film would be taken to https://core.ac.u
Storage Area the darkroom for k/download/pdf/
processing.Automatic film 10129009.pdf
processing machines have done https://www.db
away with most hand-processing m.gov.ph/wp-
and reduced the space required. content/uploads
The entrance into the darkroom /Issuances/201
should either be through a light lock 3/Joint%20Circ
or light maze. ular%202013/D
The viewing room should be located OH/Manual%20
adjacent to the darkroom to facilitate RSSGH_%203
the viewing of film as soon as %20levels.pdf
possible after processing. The room https://www.fgig
should be large enough to uidelines.org/w
accommodate several groups while p-
viewing the film. Since the film file content/uploads
has a direct relationship to both the /2016/11/1992-
darkroom and the viewing room it 93guidelines.pd
should be located so that it is f
convenient to both.
-Film storage with cabinets or
shelves for filing patient film for
immediate retrieval shall be
provided.
-Radiologist Area 5 0.96 4.80 sq.m -Offices shall include provisions for https://core.ac.u
viewing, individual consultation, and k/download/pdf/
charting of film 10129009.pdf
-Office space shall be provided as https://www.db
necessary for the functional m.gov.ph/wp-
program. content/uploads
-An appropriate area for individual /Issuances/201
consultation with referring clinicians 3/Joint%20Circ
shall be provided. ular%202013/D
OH/Manual%20
RSSGH_%203
%20levels.pdf
https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
-Pharmacy 15.00 The size and type of services to be https://core.ac.u
provided in the pharmacy will k/download/pdf/
depend upon the type of drug 10129009.pdf
distribution system used, number of https://www.db
patients to be served, and extent of m.gov.ph/wp-
shared or purchased services. This content/uploads
shall be described in the functional /Issuances/201
program. The pharmacy room or 3/Joint%20Circ
suite shall be located for convenient ular%202013/D
access, staff control, and security. OH/Manual%20
Facilities and equipment shall be as RSSGH_%203
necessary to accommodate the %20levels.pdf
functions of the program. https://www.fgig
uidelines.org/w
p-
content/uploads
/2016/11/1992-
93guidelines.pd
f
SITE SPACE PROGRAMMING

Utilities

20 An electrical room is a room or space in a building https://en


Power Room Sq.m. dedicated to electrical equipment. Its size is usually .wikipedia.
proportional to the size of the building; large org/wiki/
buildings may have a main electrical room and Electrical_
subsidiary electrical rooms. room
Includes:
• - hotel systems and locks,
• -lights
• -plug sockets,
• -switches.
A well-designed generator room will ensure that: ... https://www.
Clean and relatively cool air can circulate around cat.com/en_
the generator set. Ventilation airflow (room inlet US/by-industry/
airflow) is adequate to reject the heat produced electric-power/Articl
during operation and support the engine combustion es/ep-news
process. /ep-news-
design-generator-ro
Generator Room 20 -Generators should be elevated, especially in oms-for-optimum-
Sq.m. coastal areas. performance.html
-technicians must be able to access and service
generators, requiring proper clearances around the
units.
-Generators are loud, so designing sound barriers is
advised.
-Generators are large, bulky pieces of equipment
that require strategic placement to remain out of
sight.

-a building dedicated to the mechanical equipment


and its associated electrical equipment, as opposed
to rooms intended for human occupancy or storage. https://en.
wikipedia.org
Engineering And 100 -the most isolated space in the facility /wiki/Mechanica
Mechanical Sq.m. -acoustically insulated l_room
-driveway accessible
-away from public

Heating, ventilation, and air conditioning (HVAC)


system is designed to achieve the environmental https://www
requirements of the comfort of occupants and a .intechopen.
process. com/
H.V.A.C 50 chapters/
Sq.m. -the most isolated space in the facility 62059
-acoustically insulated
-driveway accessible
-away from public

A regular boiler sends hot water to your


radiators and a hot water cylinder, also known as a https://www
hot water tank. Water is fed by gravity into the .gregorheating.
Water Tanks Boiler 100 cylinder from a cold-water storage tank, known as a co.uk/boilers/
and Filter Sq.m. feed tank, which has to be located above it, and is
usually found either in a cupboard or in the attic or
loft space.

-the most isolated space in the facility


-acoustically insulated
-driveway accessible
-away from public

materials recovery facility (MRF), also known as


materials reclamation facility or materials recycling
facility, solid-waste management plant that
processes recyclable materials to sell to
manufacturers as raw materials for new products. Britannicahttps
MRF 6 ://www.britannica
Sq.m. -Garbage Chutes .com
-Materials Recovery Facility
-Garbage Truck Parking & Loading Station

Septic tanks are often used in rural areas, https://www.


campgrounds, and picnic areas in place of sewer sciencedirect.
systems to treat human waste and separate solids com
and liquids in wastewater. The liquid portion of the
waste is disposed of through a drain field where
natural filtering takes place in the soil.
Septic Tanks 20
Sq.m. -the most isolated space in the facility
-driveway accessible
-away from public

Drainage Channel means a drainage pathway with https://www


well-defined bed and banks indicating frequent .lawinsider.com
conveyance of surface and storm water runoff.

Drainage Channels 20 -the most isolated space in the facility


Sq.m. -driveway accessible
-away from public

Mock Examination
Loading/Unloading 100 sq.m -parking space for service vehicle Package IV
dock
-3-foot high platform
-hidden from public area

-independent driveway from street


Ambulance 18 sq.m. A provision of ambulances to take people to and hhttps://www.
from hospital as required, especially in an lexico.com
emergency.

Driveways & Parking 8,422.5 sq.m.


Area

Driveways 5,460 sq.m. a private road giving building an access. https://www.


merriam-webster.com

Public Parking 2,250 sq.m. a parking of vehicles by the general public https://www
.lawinsider.com/

Staff & Management


Parking

Management 225 sq.m. efficient parking facilities for management hhttps://www.


lexico.com

Staff 375 sq.m. efficient parking facilities for sfaffs https://en.


wikipedia.org
Public Vehicle Curb 75 sq.m. an edge where a raised sidewalk meets the https://cayug
(Jeepney Taxi) roadway ahospitality.com

Motorcycle Parking 35 sq.m. a parking space designed for any motor vehicle. https://www.
merriam-webster.com

Restroom 2.5 sq.m. a public space providing toilets and lavatories https://www
.ihmnotes.in

Landscaping 2,000 sq.m.

Front Lawn/ Fountains 500 sq.m. the enclosed land around a building Savvyhttps://
www.tripsavvy.
com

Outdoor Garden, 1500 sq.m. a public area for the showing of plants https://www.
Miscellaneous merriam-webster.com
Landscaping

10,876.5 sq.m

You might also like