NA2111A Brochure Opticlean TM 39uv Carrier
NA2111A Brochure Opticlean TM 39uv Carrier
Hospitality
Ensuring a clean, healthy and
odourless environment is key
to success in Hospitality.
Hotel Reception & Lobby
Canteens
Function rooms
Bars and Nightclubs
Health
IAQ must be managed in
line with critical healthcare
regulations, and it not
only affects patients,
Studies indicate that we The health and safety of but healthcare staff and
spend around 90% of our time indoor environmentss can visitors too.
indoors. In addition to the be significantly improved
Outpatient consulting
current circumstances, this with consistent service and rooms
has highlighted the importance maintenance of not only buildings Waiting rooms
of ensuring optimal air quality themselves, but also most Areas requiring negative
to improve occupant health. importantly HVAC systems, which pressure
Improved air quality also reliably reduce the concentration Outdoor field hospitals
has a positive impact on the of indoor contaminants by
performance and productivity of introducing filtered outdoor air
people, and their physical and into the building, and other items
mental development. such as air scrubber units.
In support of its ongoing
commitment to development Industry
and continuous improvement for
Contaminated air in
the air conditioning, ventilation production areas means
and air quality industry, Carrier extra care is needed to
launches the OptiClean™ 39UV air ensure both the health of
scrubber series. employees and equipment
The OptiClean™ 39UV air is protected.
scrubber enables Carrier to Production rooms
expand solutions to meet the Waiting rooms
Warehouses
needs of any type of building. Offices
OptiClean™ 39UV
air scrubber series
At Carrier, we continue to Our experts will advise you on
innovate, seeking new solutions your path towards buildings with
that will improve the quality healthier, safer and more productive
of HVAC and air conditioning environments, through increasingly
installations. efficient and environmentally
responsible solutions.
Technical Specifications
• Standard Plug & Play unit with • Smooth, screwless interior
EC fans and 10%-100% speed and exterior finishes for easy
control, including light for unit cleaning and maintenance.
status, ultraviolet lamp and • Maintenance access in all
filter indication. sections of the equipment.
• Silent unit for full load • Rock wool sandwich insulation
operations in spaces with in 30mm thick panels.
permanent human occupation.
Coding
The components of the OptiCleanTM 39UV air scrubber units are selected according to the following coding:
OPTIONAL
39UV - X - X - x - x - x
RANGE SIZE HEPA ADDITIONAL ACCESSORIES ELECTRIC
1= 1000 m3/h FILTER OPTIONS C= none PLUG TYPE
2= 1800 m3/h A= Hepa H13 4= none D= c ircular connexion F= T
ype F (all EU but UK & Ireland)
3= 2500 m3/h B = Hepa H14 5= UVC for duct SIZE 1 G= T ype G (UK & Ireland)
6= carbon filter H= circular connexion J= Type J (Switzerland only)
for duct SIZE 2 and 3
E= horizontal diffusion
grille SIZE 1
I= horizontal diffusion
grille SIZE 2 and 3
Range
Designed for direct use in the
room to be treated, there is
also an option for added wheels
so that the unit can be moved
where it is needed most quickly
and easily.
Model
Nominal
Motor
Flow rate available Supply Voltage Noise level
Model capacity
pressure
[m3/h] [Pa] [W] [V] dB [A]
OptiCleanTM 39 UV 10 1000 135 170 240 v 50 Hz 51
OptiCleanTM 39 UV 18 1800 465 500 240 v 50 Hz 56
Configuration M5 Prefilter
Choose the one that best meets The M5 prefilter is installed as
your installation requirements. machine protection, extending
the working life of the other
C1: H13
systems and improving the
C2: H14
efficiency of the UV lamps.
C3: H13 + UV lights
C4: H13 + carbon filters
C5: H14 + UV lights
C6: H14 + carbon filters
HEPA filters
Filters that have high filtration and 0.15 microns). They are strategy, mitigating the droplet
efficiency and are tested under normally transmitted through transmission mechanism. Large
Standard EN-1822 with MPPS integration into two types of filtrating area cell filters (depth
(particle size more difficult to droplets or bioaerosols of human 296 mm) have a much higher
filter or particle size with the origin (sneezing, coughing, particle retention capacity than
least total filtration efficiency, speech, breathing, etc.): “droplet” low-depth filters, significantly
considering the phenomena of (droplets>5microns) and reducing their maintenance
inertial impaction, interception “droplet nuclei” (<5microns). requirements and improving their
and diffusion) of 0.15 0.25 The smaller the size, the longer amortisation. H13 Hepa filters
microns. Viruses are classified as they stay in the atmosphere. efficiency 99,95%.H14 Hepa
PM1 particles (size <1 microns, HEPA filters actively participate filters efficiency 99,995%.
typically between 0.07 microns in the bioaerosol retention
Ultraviolet lamps
UV-C lamps help clean the air, micro-organisms (viruses, at a molecular level (Ashrae
reducing the concentration bacteria, etc.). Absorption of very Fundamentals, Ch. 62, Ultraviolet
pathogenic polluants. UV-C high energy over a wavelength and surface treatment).
light inactivates and inhibits of 253 nm results in irreversible
the replication of the nucleic damage to the structure of
acids (DNA and RNA) in nucleic acids and proteins
Accessories
- Absolute filter H14 - Additionnal plenum with -O
ption 2: Additionnal carbon
- Circular connexion for air duct horizontal diffusion grille filter
(dimensions depending on size) - Option 1: Additionnal UV lamps
device
Dimensions
A B
mm A B C WEIGHT (kg)
C
Operating Modes
expelled outside the building.This satisfactory ventilation or to
1.- Negative pressure mode requires ducting between support existing ventilation,
Keeps the room where the the unit and outdoors, and placing the OptiClean unit in the
equipment is located at negative supports the “air flow control” area to be treated mitigates the
pressure, creating a “vacuum strategy. contaminant load.
effect” that limits the spread of They must maintain a significant
potentially contaminated air to 2.- Recirculation hourly air movement rate to
neighbouring areas. The air in the In the event of rooms with support the retention and
room is sucked in, filtered, and difficulties in obtaining inactivation strategy.
Our control
solutions
optimise air
quality at all
times, improving
comfort and
A wide range of AHU’s can efficiency.
be customised to each of
the solutions, thanks to the
wide variety of configurations Carrier offers
available to meet the technical a wide range
requirements of your project. of services to
monitor your
buildings to
make them
safer and more
efficient.
www.carrier.com
NA21.11A Connected services leaflet - English. April 2021. ©2021 Carrier. All Rights Reserved.