OTN Manual

OTN-N215 Node
(S30826-B16-X)
Doc. No.: AB-M115-E-7
COPYRIGHT AND TRADE SECRETS/LIABILITY
The present document and its contents remain the property of OTN Systems NV and shall not, without prior
written consent, be copied or transmitted or communicated to third parties, nor be used for any other
purpose than such as underlies their delivery to the addressee.

The present document and its contents may change in the course of time or may not be suitable in a
specific situation. Consequently, they are recommended as suggested guideline only.
OTN Systems NV hereby disclaims any liability for any damages that may result from the use of the present
document unless it is used with respect to the operation and maintenance of equipment originally
manufactured by OTN Systems NV and covered by its standard warranty.
Open Transport Network OTN-N215 Node

Contents

1. INTRODUCTION ...................................................... 4

1.1 General ......................................................... 4


1.2 References ................................................... 4
2. NODE DESCRIPTION .............................................. 4

2.1 General ......................................................... 4


2.2 Power Supply Unit ....................................... 4
2.3 Network Card ............................................... 5
2.4 Interface Cards ............................................ 6
2.5 Fan Module................................................... 6
2.6 Backplane..................................................... 6
3. FUNCTIONAL OPERATION .................................... 7

3.1 Network Card ............................................... 7


3.2 Temperature Measurement and Airflow .... 7
3.3 Pre-supply Provider Strip ........................... 7
3.4 Node Status Register Circuit ...................... 7
4. POWER SUPPLY SPECIFICATIONS ...................... 7

4.1 Main characteristics .................................... 7


4.2 Power Supply Specifications ...................... 8
5. NODE SPECIFICATIONS ........................................ 8

6. INSTALLATION INSTRUCTIONS ............................ 9

7. LIST OF ABBREVIATIONS ................................... 10

List of Figures

Figure 1 N215 Node: Front View ....................................... 4


Figure 2 Airflow in N215 node (top view) ......................... 5
Figure 3 Power Supplies Front Panel View ...................... 5
Figure 4 Fan Front Panel View .......................................... 6
Figure 5 Cable support bracket is needed ....................... 9
Figure 6 N215 Node: Operation with BORA ................... 11
Figure 7 N215 Node: Operation with
BORA150/BORA600 .............................................. 12
Figure 8 N215 Node: Operation with BORA2500 ........... 13

List of Tables

Table 1 References ............................................................ 4


Table 2 Card Positions ...................................................... 4
Table 3 LEDs Fan Module .................................................. 6
Table 4 Overview Status Register 1.................................. 7
Table 5 Overview Status Register 2.................................. 7
Table 6 Overview Status Register 2 values ..................... 7
Table 7 Weight .................................................................... 8

AB-M115-E-7 Page 3 of 13
Open Transport Network OTN-N215 Node

1. INTRODUCTION
High Speed
1.1 General High Speed
High Speed FAN PSU1 PSU2
BORA150-4-SL
This document describes the N215 node (S30826-B16-X). Low Speed

N215 equipped with BORA150-4-SL


The N215 node can be equipped with a network card, four
interface cards and two redundant PSUs (PSU=power
supply unit). Two types of PSU are available: one for the High Speed
higher voltage range (100 – 240 VAC ± 10% and 125 High Speed
High Speed FAN PSU1 PSU2
VDC) and one for the lower voltage range (18 – 60 VDC). BORA
TRM TRM
One power supply is sufficient to supply the node without
any restrictions as to interface cards configuration. How- N215 equipped with BORA + TRMs

ever to increase reliability a node can be equipped with


two of these (they do not have to be of the same type). If
High Speed
one power supply should fail, the other takes over auto- High Speed

matically. Refer to §2 for an overview of the network and High Speed FAN PSU1 PSU2
BORA600-4-SL
interface card types that can be installed in the N215 Low Speed

node. N215 equipped with BORA600-4-SL

1.2 References Figure 1 N215 Node: Front View

Table 1 is an overview of the documents being referred to A backplane interconnects these cards, fan module and
in this document, ‘&’ refers to the language code and ‘*’ PSUs. Positions not containing an interface card are cov-
refers to the document issue. ered with cover plates. There are two types of cover
plates: one for the interface card positions (EC-72687-A)
Table 1 References and one for the PSU positions (V30812-A3010-A125).

Ref. Number Title Figure 1 shows the positions of the network and interface
[1] AA-M205-&-* OTN Installation and Operation cards in the node. The card positions are also indicated on
Manual the backplane.
[2] AE-M226-&-* -48 V Power Supply Modules (PSU
Table 2 Card Positions
48 V) with or without 25 Hz Ringing
Current Generator (RG-25) Card Position Card Name
[3] AD-M131-&-* BORA Network Card L1 LS interface cards
[4] AD-M132-&-* BORA150 and BORA600 Network Network Card BORA + 2 TRMs or BORA150
Cards or BORA600 or BORA2500
[5] AD-M133-&-* BORA2500 Network Card H5 ... H7 HS or LS interface cards
PSU1 Power Supply Unit 1
2. NODE DESCRIPTION
PSU2 Power Supply Unit 2
2.1 General
2.2 Power Supply Unit
The N215 node has a modular structure. The node front
(see Figure 1) houses the following: Power Supply Units PSU1 and PSU2 convert the mains or
battery input voltages to appropriate voltages for the node
a. 1 slot (=L1) for Low Speed (=LS) interface cards (Low
(+5 VDC / 12 VDC). The modules are 3 HE high (1 HE =
Speed = maximum 36 Mbps).
44.45 mm), 10 TE wide (1 TE = 5.08 mm) and 220 mm
b. a network card slot for a BORA with 2 TRMs (Trans-
deep. The PSUs are redundant, hot swappable and have
ceiver Modules) or a BORA150, BORA600 or BO-
current sharing. There are 2 different types of power sup-
RA2500. With a BORA card, the low speed slot too is
plies:
occupied.
c. 3 slots (=H5, H6, H7) for High Speed (=HS) and Low - 100-240 VAC ± 10% / 125VDC (V30812-A5020-A59).
Speed (=LS) interface cards. In these positions, inter- - 18-60 VDC (V30812-A5020-A60).
face cards with both High Speed and Low Speed ad-
dressing can be installed. Figure 3 shows the Power Supply Units’ front panels,
which are equipped with LEDs indicating the input and
d. a fan module with dual fans to ventilate the N215
output voltages. A lit green LED indicates that the voltage
node.
is present. The N215 node can operate with one or two
e. Power Supply Unit 1; power supplies in any of the provided positions.
f. Power Supply Unit 2;

AB-M115-E-7 Page 4 of 13
Open Transport Network OTN-N215 Node

Figure 2 Airflow in N215 node (top view)

V30812-A5020-A59 V30812-A5020-A60

+5V +5V
+12V +12V
-12V -12V
OFF
Vin

Vin OFF 18 - 60 VDC


100-240 VAC 10 - 3 A
125VDC

50/60 Hz ON
ON

+
-
PE
1.5A / 0.75A

PSU120-AC/DC PSU120-DC/DC

Figure 3 Power Supplies Front Panel View

If no redundant power supply is provided, the empty posi- 2.3 Network Card
tion should be covered with cover plate V30812-A3010-
A125. The BORA network card (FB-52432-1A) with separate
TRMs, or the BORA150/BORA600 (S30824-Q80-
The input power plug is located on the front of the power X/S30824-Q87-X) or BORA2500 (S30824-Q92-X) with
supplies (see Figure 3). The high-voltage power supply has integrated TRMs, interfaces between the data on the dual
a standard mains input power plug, whereas the low volt- ring and the interface cards in the node itself, and takes
age power supply has a Phoenix Contact care of start-up, synchronisation and redundancy.
(www.phoenixcontact.com) input power socket, type PC4/3-
STF-7,62; the mating connector to be used on the cable is A BORA network card with separate TRMs must still be
housing KGG-PC4/3-F with plug PC4/3-ST-7,62. used when you need SDH transceivers (e.g. STR150L).
These SDH transceivers are only available for a BORA
network card, not for a BORA150/BORA600 network card.

AB-M115-E-7 Page 5 of 13
Open Transport Network OTN-N215 Node

As the BORA card with separate TRMs is a double width If the internal temperature rises above 65 °C (149 °F), or if
card (10 TE), when it is used the LS interface slot (L1) is a fan fails, an alarm LED at the front is lighted.
occupied, and the maximum number of interface cards in a
N215 node is 3. The front of the fan module provides following indication
LEDs:
2.4 Interface Cards
Table 3 LEDs Fan Module
The node has room for maximum four interface cards (1 LS
+ 3 HS/LS). All interface cards that can be installed in an LED Color Lights if
LS card position, can also be mounted in an HS/LS card 20- Green Inside temperature below 20 °C (68 °F)
position.
20/50 Green Inside temperature between 20 °C (68 °F)
The BORA or BORA150/BORA600 card can drop up to and 50 °C (122 °F)
184 Mbps to the backplane. Bandwidth is distributed as 50+ Green Inside temperature above 50 °C (122 °F)
follows: 65+ Red Inside temperature above 65 °C (149 °F)

a. 36 Mbps to the LS part (slot L1), can, if needed, be FAN1 Red Fan 1 fails
diverted to the HS part. FAN2 Red Fan 2 fails

b. 147 Mbps to the HS/LS part. If the HS/LS part requires This information is also available via status registers.
even more bandwidth, the network card can divert the
LS part’s 36 Mbps bandwidth (or part of this) to the 2.6 Backplane
backplane’s HS/LS part. In this way, a maximum of
2.6.1 Function
184 Mbps is available in the HS/LS part (slots H5..H7).
The backplane connects the network card, interface cards
The BORA2500 card can drop up to 220 Mbps to the back-
and the Power Supply Unit(s).
plane. Bandwidth is distributed as follows:
2.6.2 Node Status
a. 36 Mbps to the LS part (slot L1).
The backplane status circuit provides two 8-bit status regis-
b. 184 Mbps to the HS/LS part (slots H5..H7). ters that can be read out by the OMS.

All periphery is connected to the Open Transport Network


through the interface cards. OTN has interface cards for
data transmission, local area networks, telephony purposes
and high quality audio/video transmission.

Each interface card is described in a separate document,


the title and number of which are indicated in the documen-
tation support plan (ref. [1]).

All interface cards can be placed and programmed in the


HS/LS slot as well as in the LS slot. For the correct pro-
gramming, see the card documentations.
ESD
2.5 Fan Module Bound Point

In order to ventilate across the full depth of the node, the


20/50

fan module is equipped with two fans, whose dimensions


20 -
50+

are 80 x 80 x 15 mm and which have rotation detection.


Blocking will be indicated by an alarm via both a red LED
on the front as well as via the status register. If only one fan
should work, the maximum ambient temperature allowed
65+
FAN1
FAN2

decreases to 50 °C (122 °F). Refer to Figure 4 for the front


panel view of the fan module.

The fans are temperature controlled: if the temperature


inside the node is lower than 20 °C (68 °F) then the fans
are switched off, if the temperature is between 20 °C
(68 °F) and 50 °C (122 °F) the fans run at reduced speed, Figure 4 Fan Front Panel View
and above 50 °C (122 °F) the fans run at full speed.

The air inlet at the front and at the back of the N215, and
the air outlet at the back should not be blocked!

AB-M115-E-7 Page 6 of 13
Open Transport Network OTN-N215 Node

Table 4 Overview Status Register 1 now have an additional 36 Mbps bandwidth, not shared
with the LS slot (L1).
Bit Description “0” “1”
The functional description of the BORA with TRMs, the
0 PSU1 operation OK Not OK
BORA150/BORA600 and the BORA2500 is described in
1 PSU2 operation OK Not Ok separate documents. See Ref.[3], Ref.[4] and Ref.[5].
2 Node type N215 -
3 Fan module detection Present Absent OMS automatically identifies the type of card that is insert-
ed.
4 PSU1 detection Present Absent
5 PSU2 detection Present Absent 3.2 Temperature Measurement and Airflow
6 Fan 1 rotation OK Not OK
The node temperature is measured and controlled by
7 Fan 2 rotation OK Not OK means of 2 sensors T1 and T2 (see Figure 2) that are ca-
pable of switching the fans. One sensor is mounted on the
pre-supply provider strip whereas the other one is mounted
Table 5 Overview Status Register 2
on the fan module. The fans do not operate below a node
Bit Description temperature of 20 °C (68 °F). The fans operate at reduced
0 Node Temperature (see Table 6) speed between 20 °C (68 °F) and 50 °C (122 °F). The fans
operate at full speed above 50 °C (122 °F) node tempera-
1 Node Temperature (see Table 6)
ture.
2 Node Firmware Edition
3 Node Firmware Edition A backplane mounted third sensor measures whether the
maximal internal node temperature (+65 °C, +149°F) is
4 Node Firmware Edition
exceeded.
5 Node Hardware Edition
6 Node Hardware Edition 3.3 Pre-supply Provider Strip
7 Node Hardware Edition
The N215 has a pre-supply power provider strip, just as the
N22. This pre-supply provider strip serves three purposes:
Table 6 Overview Status Register 2 values
- give the interface cards supply voltage just before they
make contact with the backplane connector.
Bit0 Bit1 Temperature - measure the outgoing airflow temperature.
“0” “0”
0
< 20 C - keep incoming air and outgoing air separated.

“0” “1” 20 50 C


0 3.4 Node Status Register Circuit
0
“1” “0” > 50 C The node status register circuit logs the functioning of the
0 fans, the output of the temperature sensors, and the pres-
“1” “1” > 65 C
ence and functioning of the power supplies. The circuit also
controls the front LEDs.

If the status circuit fails, the operation of the node is not


3. FUNCTIONAL OPERATION inhibited, but node status information will not be available.

3.1 Network Card 4. POWER SUPPLY SPECIFICATIONS

The BORA, BORA150, BORA600 or the BORA2500 is the 4.1 Main characteristics
node’s central control block and provides communication
with the previous and the next node (via its TRMs), the in- Applicable for power supplies
terface cards and the OMS. V30812-A5020-A59 (100-240 VAC ± 10%, 125 VDC) and
V30812-A5020-A60 (18-60 VDC)
Figure 6 shows the functional operation of the N215 node
with a BORA network card. Slot L1 is not available. The 36 Input voltage 100 – 240 VAC ± 10%
Mbps bandwidth of the L1 slot can be deviated to the HS (incl 125 VDC )
slots (H5..H7). or 18-60 VDC

Figure 7 shows the functional operation of the N215 node Input frequency 47-63 Hz (AC version)
with a BORA150/BORA600 network card. The 36 Mbps
bandwidth of the L1 slot can be deviated to the HS slots Harmonic distorsion Acc. to EN61000-3-2 (= PFC)
(H5..H7).
Outputs +5V /18 A, +12V /3 A, -12V /3 A
Figure 8 shows the functional operation of the N215 node
with a BORA2500 network card. The HS slots (H5..H7) Max. output power 120 Watt

AB-M115-E-7 Page 7 of 13
Open Transport Network OTN-N215 Node

5. NODE SPECIFICATIONS
Output ripple & noise <100 mVpp on +5 V;
<300 mVpp on ± 12 V; a. Temperature (node surrounding)

Inrush current <10 A (AC); <25 A (DC) - Operation:


- -20 °C to +55 °C
Current sharing Yes - -4 °F to +131 °F

Hot plugin Yes - Startup:


- -10 °C to +55 °C
Overvoltage protection On + 5 V output, active at + 6 V - +14 °F to +131 °F

- Storage and Shipment:


Output characteristic Rectangular - -20 °C to +70 °C
- -4 °F to +158 °F
Signalisation LED indication of input and output
voltages b. Relative Humidity (non-condensing)

Warnings DC OK output ( open collector pin - Operation: 20 % to 80 % at 25 °C (+77 °F) (node


26 ) surrounding)
- Storage and shipping: 20 % to 95 %
Operating temp. range -40 °C to +65 °C
c. Weight
(-40 °F to +149 °F)

Relative humidity 20 % .. 95 % non-condensing Table 7 Weight

MTBF >100000 hours at 50 °C Node/Module Number Weight


N215 S30826-B22-X 5.6 kg
Safety Acc. to EN60950 (+ 2 PSUs, common
logic card and fan unit)
Environment test Acc. to IEC60068
condition PSU-AC V30812-A5020-A59 1.360 kg

Emissions Acc. to EN50081-1 PSU-DC V30812-A5020-A60 1.380 kg

Immunity Acc. to EN50082-2


d. MTBF
Size Euro Cassette 3HE/10TE/220
- MTBF Power Supply: >100000 h at 50 °C (122 °F)
Connector back DIN41612-H15 - MTBF backplane N215 : 571 years at 25 °C (77 °F)
- Life Expectancy Fans : 70000 h at 40 °C (104 °F)
and full speed continuous use.

e. Electromagnetic Compatibility
4.2 Power Supply Specifications
- Emission: EN 61000-6-4, EN 55022, Class A
- The 18..60 V DC power supply is a DC-DC converter - Immunity: EN 61000-6-2
with electrical insulation between input and output
f. Power Consumption of an empty node
voltages. Reverse polarity will not damage the PSU,
but will prevent it from working.
- +5 V output : 575 mA (with fans running)
- The on/off switch on both versions is of an electronic 390 mA (with fans off)
type and does not interrupt the input voltage, but uses
the internal inhibit function of the PSU’s control circuit. - +12 V output : 270 mA

- The maximum input current is 2 A for the 100-240 VAC - -12 V output : 270 mA
± 10% version and 10 A for the 18-60 VDC version. - DC empty node (only backplane) = 22 W
- The outputs are short-circuit proof and have a - AC empty node (only backplane) = 20 W
“rectangular” output characteristic. If too much current
is drawn from the PSU, the current will stay at it’s - DC Power supply efficiency = 72.5 %
maximum value, but the output voltage will drop.
- AC Power supply efficiency = 76.7 %
- The internally dissipated power of the PSU varies
between 16 W and 40 W, depending on the load. - P = power consumption

- = power supply efficiency

AB-M115-E-7 Page 8 of 13
Open Transport Network OTN-N215 Node

- Ptot-DC = (Pcard / DC) + Pempty-DC CAUTION – ATTENTION!


- Ptot-AC = (Pcard / AC) + Pempty-AC Double pole/neutral fusing.
- E.g. some cards with a total power consumption of For DC input power supply modules: never apply
100 W are inserted into the node. What is the total a too high input voltage and respect the correct
power consumption? polarity. If the node is connected to an incorrect
voltage source, the power supply unit will be
- Ptot-DC = (Pcard / DC) + Pempty-DC damaged.
= (100 W / 0.725) + 22 W = 160 W
Plugging the network card into a slot other than
- Ptot-AC = (Pcard / AC) + Pempty-AC the network card slot will damage the network
= (100 W / 0.767) + 20 W = 150 W card.

g. Dimensions: There exist old and new PSU versions:


old:V30812-A5020-A29/A30
new:V30812-A5020-A59/A60
- width: 484 mm;
- height (3 HU): 133 mm; When using two PSUs in one node, never mix old
- depth: 290 mm; (excluding the cables and new versions. It could cause load sharing
at the front) problems and service disturbances at PSU switch
on/off.
h. Dust
The front must be easily accessible to carry out the follow-
An excessive deposit (especially of conductive dust), in
ing actions:
combination with a high degree of humidity could cause
system operation interruptions, and must therefore be - connect optical cables;
avoided. - plug in interface cards;
- system supervision (LED indications and
i. Cooling alphanumerical display), test and diagnostics;
- add or replace cards;
The node is equipped with a temperature controlling - connect power cables.
fan module with dual fans.
It is advised to install the supplied cable support bracket. It
j. Certification must be screw-tightened to the front of the fan module (see
Figure 5). Purpose of this cable support bracket is to keep
- FCC Part 15 CIA Pending the cabling in its proper place and therefore diminish a pos-
- CE Marking sible strain on the connectors.
- EMC directive 89/336/EEC
- LVD directive 73/23/EEC Cable support bracket = C30165-A9550-D22, standard
included with the N215 node.
k. Input Voltage range
Instructions for node installation can be found in document
- V30812-A5020-A59: 100-240 VAC ± 10% /
ref. [1].
125 VDC
- V30812-A5020-A60: 18-60 VDC.

l. Maximum Absorbed Power: < 380 W

m. Fuses:

- Fuse T6.3 A/250 V for the AC power supply;


- The fuses for the DC power supplies are non-
replaceable.

n. Secondary voltages:

- +5 VDC / 18 A
- +12 VDC / 3 A
- -12 VDC / 3 A

6. INSTALLATION INSTRUCTIONS

Cable number S30827-C96-Axx is available for connecting


Figure 5 Cable support bracket is needed
the DC power supply units with an <xx> unit representing
10 cm or 3.93 inch, e.g. S30827-C96-A50 represents a
5.00 m cable.

AB-M115-E-7 Page 9 of 13
Open Transport Network OTN-N215 Node

7. LIST OF ABBREVIATIONS

BORA Broadband Optical Ring Adapter


EMC ElectroMagnetic Compatibility
HS High Speed
IFC Interface Card
LED Light Emitting Diode
LS Low Speed
MTBF Mean Time Between Failure
OMS OTN Management System
OTN Open Transport Network
OTR Optical Transmitter and Receiver
PSU Power Supply Unit
TRM Transceiver Module

AB-M115-E-7 Page 10 of 13
+12V LED 50+ LED FAN2

AB-M115-E-7
-12V LED 20/50 LED FAN1 Temp Sensor 3
+5V LED 20- LED 65+ 65°C (149°F)
Power Supply 2 GND FAN 1 FAN 2
PWS2_present
Open Transport Network

PWS2_ok Fan1 ok
Fan2 ok

+12V
Temp Sensor 1 Temp Sensor 2
-12V
+5V 20°C (68°F) 20°C (68°F)
Power Supply 1 GND Node Status 50°C (122°F) 50°C (122°F)
PWS1_present Circuit
PWS1_ok

BORA
TRM 2 STATUS AND CONTROL BUS

TRM 1 LS Databus 1 (3 x 12 Mbps, left)


36 Mbps
Additional HS Databus 1 (3 x 12 Mbps, right)

36 Mbps LS Databus 2 (3 x 12 Mbps, right)

Figure 6 N215 Node: Operation with BORA


147 Mbps HS Databus (9 x 12 Mbps, right)

IFC IFC IFC


H5 H6 H7
OTN-N215 Node

Page 11 of 13
+12V LED 50+ LED FAN2

AB-M115-E-7
-12V LED 20/50 LED FAN1 Temp Sensor 3
+5V LED 20- LED 65+ 65°C (149°F)
Power Supply 2 GND FAN 1 FAN 2
PWS2_present
Open Transport Network

PWS2_ok Fan1 ok
Fan2 ok

+12V
Temp Sensor 1 Temp Sensor 2
-12V
+5V 20°C (68°F) 20°C (68°F)
Power Supply 1 GND Node Status 50°C (122°F) 50°C (122°F)
PWS1_present Circuit
PWS1_ok

BORA150/600
STATUS AND CONTROL BUS
TRM 2

TRM 1

LS Databus 1 (3 x 12 Mbps, left)


36 Mbps
Additional HS Databus 1 (3 x 12 Mbps, right)

36 Mbps LS Databus 2 (3 x 12 Mbps, right)

147 Mbps HS Databus (9 x 12 Mbps, right)

Figure 7 N215 Node: Operation with BORA150/BORA600


IFC IFC IFC IFC
L1 H5 H6 H7
OTN-N215 Node

Page 12 of 13
+12V LED 50+ LED FAN2

AB-M115-E-7
-12V LED 20/50 LED FAN1 Temp Sensor 3
+5V LED 20- LED 65+ 65°C (149°F)
Power Supply 2 GND FAN 1 FAN 2
PWS2_present
Open Transport Network

PWS2_ok Fan1 ok
Fan2 ok

+12V
Temp Sensor 1 Temp Sensor 2
-12V
+5V 20°C (68°F) 20°C (68°F)
Power Supply 1 GND Node Status 50°C (122°F) 50°C (122°F)
PWS1_present Circuit
PWS1_ok

BORA2500
STATUS AND CONTROL BUS
TRM 2

TRM 1

36 Mbps LS Databus 1 (3 x 12 Mbps, left)

36 Mbps Additional HS Databus 1 (3 x 12 Mbps, right)

36 Mbps LS Databus 2 (3 x 12 Mbps, right)

Figure 8 N215 Node: Operation with BORA2500


147 Mbps HS Databus (9 x 12 Mbps, right)

IFC IFC IFC IFC


L1 H5 H6 H7
OTN-N215 Node

Page 13 of 13