You are on page 1of 1

NOTE :

A B C ►THE STRUCTURE WAS DESIGNED BASED ON THE NSCP 2015 WIND LOAD PARAMETERS OF
WIND SPEED, V = 270 kph AND EXPOSURE "B" (URBAN OR SUBURBAN AREAS WITH NUMEROUS
CLOSELY SPACED OBSTRUCTION ).

7000 2500
1

±350 S-6
±350
±500
±500 4
APEX LINE OF TRUSS ±500
±500 S-6
±500
±500
±500
±500
A A
±500
±500
±500
±500
A ±500
±500 A 1
1800

±500 S-7
±500 C C
D D ±350
±350 D C
A A
D D
C C
A A
D D
C C
D D
TOP LINE OF ROOF BEAM
B B B B B B B B
3 2 2
400

S-6 S-6 S-7

±1187 ±1187 ±1887 ±1187 ±1125 ±1125 ±1250 ±1250

NOTES ON ROOF CONSTRUCTION :

1. IN ACTUAL FABRICATION OF STEEL TRUSSES, MEMBERS MEETING AT POINT SHALL HAVE


THEIR GRAVITY AXIS INTERSECT AS NEARLY AS PRACTICABLE AT A COMMON POINT.
2. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACINGS AND SHORING, AND L1 SCHEDULE OF MEMBERS AND WELDS
MAKE ACTUAL MEASUREMENTS IN THE FIELD PRIOR TO FABRICATION/INSTALLATION OF 2 DETAIL ELEVATION OF TRUSS STITCH WELD
6mm GUSSET ⅊, Typical
ALL TRUSSES. SIZE OF WELDS
3. THE FABRICATOR/CONTRACTOR SHALL SUBMIT SHOP DETAILED DRAWINGS PRIOR TO S-5 SCALE 1:20 M
TRUSS MEMBERS

L3
FABRICATION OF TRUSSES FOR APPROVAL OF THE DIRECTOR, BUREAUS OF DESIGN. MARK LENGTH, mm REMARKS
SIZES THICKNESS
TRUSS MEMBER L1 L2 L3
L2
A 2∠s - 65 x 65 x 6 6mm FULL WELD

B 2∠s - 65 x 65 x 6 6mm 125 100 50

3 REFERENCE WELD DETAIL C 2∠s - 50 x 50 x 6 6mm 125 100 50

SCALE 1:10 M
S-5 D 2∠s - 50 x 50 x 6 6mm 100 75 50

1 2 3 4 5 6 7 8 9 10 11
45000
9000 9000 9000 9000 9000
4500 4500 4500 4500 4500 4500 4500 4500 4500 4500
1200

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1
GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1

A RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1
3500

RB-2

RB-2

RB-2

RB-2

RB-2

RB-2

RB-2

RB-2

RB-2

RB-2

RB-2
7000

RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1
LRB-1 ( ABOVE )

LRB-1 ( ABOVE )
TRUSS - 1

TRUSS - 1

TRUSS - 1

TRUSS - 1

TRUSS - 1

TRUSS - 1

TRUSS - 1

TRUSS - 1

TRUSS - 1
3500

B RB-1 RB-1 RB-1 RB-1 C1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1
RB-3

RB-3

RB-3

RB-3

RB-3

RB-3

RB-3

RB-3

RB-3

RB-3

RB-3
2500

C
CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1

CB-1
RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1
1200

GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1 GB-1

120 x 60 x 20 x 6mm
1 ROOF FRAMING PLAN
12mmØ CROSS BRACINGS 10mmØ SAGRODS @
LC-PURLINS @ 500mm O.C. S-5 SCALE 1:100 M WITH STD. TURN BUCKLE MIDDLE THIRDS (STAGGERED)

REPUBLIC OF THE PHILIPPINES DESIGNED: SIGNED RECOMMENDING APPROVAL: APPROVED: CONCURRED:


PROJECT AND LOCATION: SHEET CONTENTS: SUBMITTED: SET NO. SHEET NO.
DANIEL C. MATANGUIHAN
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS ROOF FRAMING PLAN
ENGINEER II

DETAIL ELEVATION OF TRUSS DRAWN/AUTOCAD: SIGNED


BUREAU OF DESIGN MODFIEIDSTANDARDDPWHD
ONE(1)STOREY,FIVE(5)CLASSROOM
-EPE
-D
SCHEDULE OF TRUSS MEMBERS AND WELDS
REFERENCE WELD DETAIL
K.A.C.M , D.C.M , M.A.H.A
STRUCTURAL
JOSEPHINE P. ISTURIS
SIGNED SEE COVER SHEET FOR SIGNATURE
LEA N. DELFINADO, CESO IV
SEE COVER SHEET FOR SIGNATURE

EMIL K. SADAIN
SEE COVER SHEET FOR SIGNATURE
LEONOR M. BRIONES
BOD
S-5
BUILDINGS DIVISION SCHOOLBUILDING CHECKED: SIGNED 7 8
N
(OTOLIETATTACHED) B
KATHRINE ANNE C. MACOY CHIEF, BUILDINGS DIVISION OFFICER IN-CHARGE, BOD
UNDERSECRETARY FOR UPMO OPERATIONS SECRETARY, DEPED
BONIFACIO DRIVE PORT AREA, MANILA O
(PTO
IN2) ENGINEER IV AND TECHNICAL SERVICES