Maintenance specification

Model
Item Unit
85AEHD 85AED 85AET
PTT system
Trim sensor resistance
at 20°C (68°F) (P–B)
Trim sensor setting resistance
at 20°C (68°F) (P–B)



168.3–288.3

9–11 1
Fluid type — ATF

Motor type
Output
Brushes
kW


Dexron 2
6H102
0.3
2
Standard length mm (in) — 9.75

Wear limit
Commutator
Standard diameter
mm (in)

mm (in)


(0.384)
5.5 (0.22)

22.0 (0.87)
3
Wear limit mm (in) — 21.0 (0.83)
Standard undercut

Wear limit
mm (in)

mm (in)


1.8
(0.07)
1.3
4
(0.05)

5
Hydraulic pressure (down) MPa (kgf/cm2) — 2.2–3.8
(22-38)
Hydraulic pressure (up) MPa (kgf/cm2) — 9–11
(90–110)

6
7
8
9
6885J11 2-14