POWR Power unit

12. Install the new gasket r and cylinder 13. Install the thermoswitch u, new gasket
head t, and then tighten the cylinder i, cylinder head cover o, and then tight-
head bolts y to the specified torques in 2 en the cylinder head cover bolts p.
stages and in the sequence as shown.
u

r
t

y i
p
68850700
68850690

68850710

68850760
NOTE:
NOTE: Remove any oil or grease from the cylinder
Remove any oil or grease from the cylinder head and cylinder head cover mating sur-
head mating surfaces. faces.

Cylinder head bolt y:


1st: 15 N·m (1.5 kgf·m, 11.1 ft·lb)
2nd: 30 N·m (3.0 kgf·m, 22.1 ft·lb)

5-35 6885J11