Professional Documents
Culture Documents
00
3.00
APPROVED EDITION OF THE PHILLIPINE ELECTRICAL CODE (PEC), RULES AND REGULATIONS
3.00
3.35
3.35
6.70
6.70
C2
6.70
6.70
ELECTRICAL ENGINEER SHALL EXECUTE ALL ELECTRICAL WORKS HEREIN INCLUDE. WORKS HERIN INCLUDE. WOKS SHALL
BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHD.
S1 ALL MATERIALS USED SHALL BE NEW AND APPROVED FOR BOTH PURPOSE AND LOACTION INTENDED.
3.70
3.70
3.35
3.35
15-Watts LB ALL WIRES TYPE TW / THW SHAL BE INSULATED FOR 600 VOLTS AND SHALL BE INSIDE RIGID
15-Watts LB uPVC PIPES. ELECTRICAL TRADE SIZES WERE USED (A MINIMUM OF 15mm DIAMETER FOR
CONDUITS AND 3.5mm sq FOR CIRCUITS RUNS). ALL CIRCUIT BREAKERS SHALL BE BOLT-ON
S2
C1 NO BRANCH CIRCUIT SHALL BE HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
ELECTRICAL SERVICE REQUIREMENTS SHALL BE 220 VOLTS, 1-PHASE, 60 HERTZ.
YPE AND INSIDE FACTORY STANDARD ENCLOSURES.
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
TO POWER SOURCE
220V, 2P, 60 HERTZ PB1 SCHEDULE OF LOADS
M QUANTITY POWER SWITCH CIRCUIT
CKT. NO. (WATTS) CURRENT VOLTS PHASE CONDUIT SIZE WIRE SIZE
BREAKER
1 - # 8.0mm² TW DESCRIPTION LIGHT CO OTHERS S1 S2 S3 3WAY
1 - # 2.0 mm² THHN PB 1 11-Watts PINLIGHT 4 44 0.2 2 1 220 10 20mm Ø PVC PIPE 2 - 3.5mm² THHN WIRE
30AT, 2P
220 V 2 CO 5 1000 4.55 220 10 25mm Ø PVC PIPE 2 - 5.5mm² THHN WIRE
10AT, 2P 10AT, 2P 3 REF. CO 1 300 1.36 220 10 25mm Ø PVC PIPE 2 - 5.5mm² THHN WIRE
1 2
10AT, 2P SPARE
4 SPARE - - - - - - - - - - - - - -
3 4
TOTAL 1,344 6.11 220 30 AT 2P 32mm Ø PVC PIPE