Technical specification 

Charger for LiFePO4 cells 

3.6 V/20 A 
 
 

 
 
 

 
 
 

Charger 3.6 V/20 A for LiFePO4 cells 

1. INPUT CHARACTERISTICS 
No. Item  Technical specification  Unit  Remark 

1‐1  Rated input voltage  120 V / 230 V Vac  


1‐2  Input voltage range  AC 100 – 240 V Vac  
1‐3  AC input voltage frequency  47 – 63 Hz  
1‐4  Max input current  2 A  A  

2. OUTPUT CHARACTERISTICS 
No. Item  Technical specification  Unit  Remark 

2‐1  Nominal charge voltage  3 V  Vdc 1 cells @ 3 V 


1 cells @ 3.65 V 
2‐2  Fast charge voltage  3,65 V  Vdc 
+/‐ 0.05 VDC 
2‐3  Maintain voltage  3.65 V  Vac (Float voltage)
2‐4  Constant current  20 A  A  
2‐5  Power efficiency  > 80 % @ 230 Vac 

3. PROTECTION CHARACTERISTICS 
No. Item  Technical specification  Unit  Remark 

3‐1  Output over voltage protection  3.7 V  Vdc  


The charger software limits the maximum 
3‐2  Software over voltage protection  output voltage to a level suitable for the     
connected battery cell.
The internal temperature monitor reduces the 
3‐3  Thermal cutback  charger output power in extreme operational     
temperature to prevent damage. 
3‐4  Output current limiting protection  21 A  A @ CC Mode 
Short circuit protection at the output 
3‐5  Output short circuit protection  terminals. Automatic recovery after restoring     
to normal conditions.
The charger is electronically protected against 
3‐6  Electronic reverse battery protection     
permanent reversed battery connection.
 
 
4. CHARGE INDICATOR (LED) 
No. Item  Technical specification  Unit  Remark 

4‐1  Charging  Red LED on  


4‐2  Complete charge  Green LED on  

5. SAFETY & EMC (CE CONFORMITY REQUIREMENTS) 
No. Item  Technical specification  Unit  Remark 

5‐1  Electric strength test input ‐ output  1500 V / 10 mA /1 minute Vac No breakdown


5‐2  Isolation resistance  > 10 MOhm @ 500 Vdc MOhm  Input ‐ ground (GND)
5‐3  Isolation resistance  > 10 MOhm @ 500 Vdc MOhm  Output ‐ ground (GND)
5‐4  Leakage current  < 3.5 mA A Vin = 264 Vac, 50 – 60 Hz
5‐5  Safety  EU standards for small electrical appliances    CE MARK 
5‐6  EMC ‐ RE  Class B EN55014 
5‐7  EMC ‐ CE  Class B EN55014 
5‐8  EMC ‐ air discharge   Level 3 EN61000‐4‐2 (dis. B)
5‐9  EMC ‐ contact discharge  Level 3 EN61000‐4‐2 (dis. B)
5‐10  EMC ‐ RS  Level 3 EN61000‐4‐6 (dis. A)
5‐11  EMC ‐ CS  Level 3 EN61000‐4‐3 (dis. A)
5‐10  EMC ‐ EFT  Level 3 EN61000‐4‐4 (dis. B)
EN61000‐4‐5 (dis. A) 
5‐10  EMC ‐ Surge  Level 3   
1 kV, 2 kV (dis. B) 

6. ENVIRONMENTAL TEST REQUIREMENTS 
No. Item  Technical specification  Unit  Remark 

6‐1  High ambient operating temperature  +40 °C  deg C Continuous operation


6‐2  Low ambient operating temperature  ‐10 °C  deg C Continuous operation
Allow 2 hours to recover  
6‐3  Highest storage temperature  +70 °C  deg C 
to normal temperature
Allow 2 hours to recover  
6‐4  Lowest  storage temperature  ‐40 °C  deg C 
to normal temperature
6‐5  Drop shock  40 g peak EN60068‐2‐32:1993
 
 
7.  CHARGING CURVE 

 
 
 
 
 

EVPower a.s. 
Průmyslová 11, 102 19 Prague 10   
Czech Republic, European Union

You might also like