It provides relationship of density with pressure, × temperature and molecular weight. Gas density = It helps to estimate impact of operating parameter × on power. Power ∝ Gas density Equipment is categorized as compressor, blower or Fan based on its pressure ration. As per ASME… Pressure ratio = Pressure ration > 1.2 → Compressor, 1.11 < Pressure ration < 1.2 → Blower 1.11 > Pressure ration → Fan Energy required to move unit mass of gas from one Adiabatic (Isentropic) Head point to another, it is work of compressor = −1 −1 performed on unit mass of gas. It is applicable when there is no heat transfer Estimate temperature increase of gas due to Discharge Temperature ≅ compression process
−1 1 −1 Polytrophic exponents is required to estimate
Polytropic exponent ≅ Head for polytrophic compression. Energy required to move unit mass of gas from one point to another, it is work of compressor Polytropic Head = −1 performed on unit mass of gas. −1 It is applicable when heat transfer takes place during the compression process. Estimate temperature increase of gas due to Discharge Temperature ≅ compression process Mass flow rate = × × It is required to select suitable driver and evaluate Power Gas required = 3.6 × 10 × system efficiency.
Symbols, descriptions and units
Symbol What it stands for Unit
Gas density at given temperature and pressure ⁄ Absolutes Suction pressure KPa Molecular weight Gas constant Its value is 8.3145 Kg-m/Kg-mole-K Absolute Suction temperature Kelvin, K = °C + 273.15 Absolutes Discharge pressure KPa , Head / k Specific heat ratio ⁄ z Compressibility factor Absolute discharge temperature Kelvin, K = °C + 273.15 Volumetric flow rate A /Hour Mass flow rate ⁄ Power Gas required KW Adiabatic or Polytropic efficiency